• Title/Summary/Keyword: Number concentration

Search Result 3,997, Processing Time 0.031 seconds

The Concentration of TSP and Heavy Metals in the Indoor Air of Local PC Rooms (지방 일개도시 PC방에서의 실내공기중 TSP농도와 TSP내 중금속 농도)

  • Cha Hyun Su
    • Journal of Korean Public Health Nursing
    • /
    • v.16 no.1
    • /
    • pp.190-200
    • /
    • 2002
  • This study was carried out to investigate and analyze TSP of the PC rooms. The concentration of the total suspended particulate and heavy metals contained in the total suspended particulate of the 15 PC rooms located in one local city were measured. The statistical correlation coefficients between the total suspended particulate and factors of the indoor condition (number of fan or size of pc room, illumination), between the heavy metals and factors of the indoor condition were studied. The results are as follows: 1. The factors of the indoor condition of the 15 PC rooms are as follows. Average illumination was 24 luxes. Average number of computers installed were 37. Average number of the fans was 7. and the size of investigated PC rooms was $139.94m^2$. 2. The mean age of the subjects was 21.8 years old. they $(51.5\%)$ used the 15 pc rooms for fewer than 2 hours per one day. 3. The mean concentration of total suspended particulate (TSP) is lower in the evening ${139.085\;(2.462)\;{\mu}g/m^3}$ than the night ${166.216(2.609){\mu}g/m^3}$. 4. The mean concentration of total suspended particulate was industrial work area) residential area) commercial area. 5. The distribution of heavy metals were indicated as Zn>Cr>Pb>Cd in the indoor air at PC rooms. and the concentration rate of Zn was the highest among heavy metals. but this increase didn't show any relationship with many factors of indoor condition (number of fan or size of pc room, lighting) 6. The concentration of TSP & heavy metals didn't have any relationship between the factors of indoor environment (number of fans, size of pc room, lighting).

  • PDF

A NUMERICAL STUDY ON THE CONTROL OF PARTICLE CONCENTRATION DISTRIBUTION IN A PIPE (관에서의 입자농도분포 제어에 관한 수치적 연구)

  • Yi, Min-Young;Yoo, Joo-Sik
    • Journal of computational fluids engineering
    • /
    • v.14 no.4
    • /
    • pp.62-66
    • /
    • 2009
  • The control of particle concentration distribution in a pipe with an orifice and a sheath air is numerically investigated. When using Eulerian approach, there is no great change in the concentration distribution by the shape of orifice and molecular diffusivity. As the Reynolds number becomes small, the effect of orifice on the concentration distribution is decreased. For small Reynolds number, the concentration distribution can be effectively controlled by using a sheath air. The effect of the sheath air on the concentration distribution is increased, as the Reynolds number becomes small.

Uninary Nicotine and Cotinine Levels in Smokers and Nonsmokers Related to Smoking Habit in Korea

  • Hwang, Keon-Joong;Rhee, Moon-Soo;Ra, Do-Young
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.1
    • /
    • pp.71-76
    • /
    • 2001
  • This study was conducted to determine the urinary nicotine and cotinine concentration in 126 smokers and 143 nonsmokers. While urine samples were being collected, personal characteristics related to smoking habit such as sex, age, number of years since a person has been a smoker, average number of cigarettes consumed per day, and number of smokers in the family were surveyed. Urinary nicotine and cotinine concentration were analyzed by GC/NPD. The smokers smoked an average 17.0 cigarettes per day and the average concentration of nicotine and cotinine was 3.88 $\mu\textrm{g}$/ml and 3.64 $\mu\textrm{g}$/ml, respectively. The average number of smokers in the family was 0.72 persons and the average concentration of nicotine and cotinine were 0.11 $\mu\textrm{g}$/ml and 0.02 $\mu\textrm{g}$/ml in the urine of non-smokers, respectively. The concentration of nicotine and cotnine in smoker\`s urine was dependent on the number of cigarettes smoked per day(p<0.01). The number of years since a person had been a smoker, and the number of smokers in the family were not associated with the concentration of nicotine and cotinine. Also there was no significant effects of passive smoking on the family of smokers by the level of nicotine and cotinine concentration. We describe the relationship between smoking habit as assessed by urinary nicotine and cotinine excretion. This study provides an evidence for the assessment of active and passive exposure to tobacco smoke.

  • PDF

Shooting method applied to porous rotating disk: Darcy-Forchheimer flow of nanofluid

  • Muzamal Hussain;Humaira Sharif;Mohamed A. Khadimallah;Abir Mouldi;Hassen Loukil;Mohamed R. Ali;Abdelouahed Tounsi
    • Advances in nano research
    • /
    • v.14 no.3
    • /
    • pp.295-302
    • /
    • 2023
  • The characteristics of motile microorganism and three dimensional Darcy-Forchheimer nanofluid flow by a porous rotatable disk with heat generation/absorption is reported. Thermophoretic and Brownian motion aspects are included by utilizing Buongiorno model. Moreover, slip conditions are considered on velocity, thermal, concentration and microorganism. Shooting procedure is implemented to find the numerical results of physical quantities are evaluated parametrically. The different physical parameters like heat sink/source parameter, thermal, Brownian number, thermophoresis parameter, concentration, Peclet number, bioconvected Lewis number, microorganism on concentration and density of motile microorganism distributions is considered. Graphs of concentration and microorganism are plotted to examine the influence of distinct prominent flow parameters.

Improvement of Cloud Physics Parameterization in the KMA Earth System Model (기상청 지구시스템모델에서의 구름입자 수농도 모수화 방법 개선)

  • Lee, Hannah;Yum, Seong Soo;Shim, Sungbo;Boo, Kyung-On;Cho, ChunHo
    • Atmosphere
    • /
    • v.24 no.1
    • /
    • pp.111-122
    • /
    • 2014
  • In the Korea Meteorological Administration earth system model (HadGEM2-AO), cloud drop number concentration is determined from aerosol number concentration according to the observed relationship between aerosol and cloud drop number concentrations. However, the observational dataset used for establishing the relationship was obtained from limited regions of the earth and therefore may not be representative of the entire earth. Here we reestablished the relationship between aerosol and cloud drop number concentrations based on a composite of observational dataset obtained from many different regions around the world that includes the original dataset. The new relationship tends to provide lower cloud drop number concentration for aerosol number concentration < 600 $cm^{-3}$ and the opposite for > 600 $cm^{-3}$. This new empirical relationship was applied to the KMA earth system model and the historical run (1861~2005) is made again. Here only the 30 year (1861~1890) averages from the runs with the new and the original relationships between aerosol and cloud drop number concentrations (newHIST and HIST, respectively) were compared. For this early period aerosol number concentrations were generally lower than 600 $cm^{-3}$ and therefore cloud drop number concentrations were generally lower but cloud drop effective radii were larger for newHIST than for HIST. The results from the complete historical run with the new relationship are expected to show more significant differences from the original historical run.

Characteristics of In-cabin PM2.5 Concentration in Seoul Metro Line Number 2 in Autumn (서울시 지하철 2호선의 가을철 객실 PM2.5 농도의 특성)

  • Shin, Hyerin;Jung, Hyunhee;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.2
    • /
    • pp.186-191
    • /
    • 2019
  • Objectives: Subway is one of the most common transportation modes in Seoul, Korea. The objectives of this study were to determine characteristics of in-cabin $PM_{2.5}$ concentration in Seoul Metro Line Number 2 and to identify factors of the $PM_{2.5}$ concentration. Methods: In-cabin $PM_{2.5}$ concentrations in Seoul Metro Line Number 2 were measured using real-time monitors and the factors affecting $PM_{2.5}$ concentration in cabin were observed. Linear regression analysis of in-cabin $PM_{2.5}$ concentration and indoor/outdoor (I/O) ratio were performed. Results: In-cabin $PM_{2.5}$ concentration was associated with the in-cabin $PM_{2.5}$ concentration in previous station. In-cabin $PM_{2.5}$ concentration was correlated with ambient $PM_{2.5}$ concentration and associated with underground station with control of the in-cabin $PM_{2.5}$ concentration in previous station. I/O ratio increased as the number of passengers increased and when passing through the underground station with control of I/O ratio in previous station. Conclusion: In-cabin $PM_{2.5}$ concentration was affected by ambient $PM_{2.5}$ concentration. Therefore, management of in-cabin $PM_{2.5}$ concentrations should be based on outdoor air quality.

The Fluctuations of Aerosol Number Concentration in the leodo Ocean Research Station (이어도 해양종합과학기지에서의 에어로솔 수 농도 변동)

  • Park, Seong-Hwa;Lee, Dong-In;Seo, Kil-Jong;You, Cheol-Hwan;Jang, Min;Kang, Mi-Yeong;Jang, Sang-Min;Kim, Dong-Chul;Choi, Chang-Sup;Lee, Byung-Gul
    • Journal of Environmental Science International
    • /
    • v.18 no.7
    • /
    • pp.721-733
    • /
    • 2009
  • To examine the fluctuations of aerosol number concentration with different size in the boundary layer of marine area during summer season, aerosol particles were assayed in the Ieodo Ocean Research Station, which is located 419 km southwest of Marado, the southernmost island of Korea, from 24 June to 4 July, 2008. The Laser Particle Counter (LPC) was used to measure the size of aerosol particles and NCEP/NCAR reanalysis data and sounding data were used to analyze the synoptic condition. The distribution of aerosol number concentration had a large variation from bigger particles more than 3 ${\mu}m$ in diameter to smaller particles more than 1 ${\mu}m$ in diameter with wind direction during precipitation. The aerosol number concentration decreased with increasing temperature. An increase (decrease) of small size of aerosol (0.3${\sim}$0.5 ${\mu}m$ in diameter) number concentration was induced by convergence (divergence) of the wind fields. The aerosol number concentration of bigger size more than 3 ${\mu}m$ in diameter after precipitation was removed as much as 89${\sim}$94% compared with aerosol number concentration before precipitation. It is considered that the larger aerosol particles would be more efficient for scavenging at marine boundary layer. In addition, the aerosol number concentration with divergence and convergence could be related with the occurrence and mechanism of aerosol in marine boundary layer.

Indication of Photochemical Air Pollution in the Greater Seoul Area, 1990 to 1995 (1990~1995 서울ㆍ수도권 지역의 광화학 오염현상)

  • 김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.1
    • /
    • pp.41-49
    • /
    • 1997
  • Status of photochemical air pollution in the Greater Seoul Area (GSA) between 1990 and 1995 was assessed in terms of frequency distributions, number of days exceeding standards, average concentration and meteorological effects. In Seoul compared with other areas in Korea, daily maximum concentration was higher but average concentration was not so high due to lower daily minimum from April to October. The top 5th percentile was high especially in summer season. Average number of days exceeding 100 ppb at monitoring stations in GSA was highest in 1994, the hottest year, but it was only 4 days a year. Mean meteorological pattern of high ozone days could be summarized as low wind speeds, high temperatures, strong solar radiation, and low precipitation. Westerlies were more frequent on high ozone days and at Pangi station located in the eastside of GSA, both number of high ozone days and average concentration were high. Effect of precursor transport on the rise of ozone concentration was, however, not consistently important on the whole in GSA.

  • PDF

The Fluctuation of Aerosol Number Concentration by Wind Field Variation during Snowfall at the Southwestern Coastal Area (남서해안지역 강설시 바람장 변화에 따른 에어로솔 수 농도 변동)

  • Lee, Dong-In;Kang, Mi-Young;Seo, Kil-Jong;You, Cheol-Hwan;Park, Sung-Hwa;Kim, Poo-Kyoung;Park, Nam-Sik
    • Journal of Environmental Science International
    • /
    • v.17 no.6
    • /
    • pp.699-709
    • /
    • 2008
  • To understand the development mechanism of the aerosols in the surface boundary layer, the variation in the aerosol number concentration due to the divergence and convergence of the wind fields was investigated. The aerosol number concentration was measured in the size ranges of $0.3{\sim}10.0{\mu}m$ using a laser particle counter(LPC) from 0000 LST on 03 Feb. to 0600 LST on 07 Feb. 2004 at Mokpo in Korea during snowfall. The Velocity Azimuth Display(VAD) technique was used to retrieve the radar wind fields such as the horizontal wind field, divergence, and deformations including the vertical air velocity from a single Doppler radar. As a result, the distribution of the aerosol number concentration is apparently different for particles larger than $1{\mu}m$ during snowfall, and it has a tendency to increase at the beginning of the snowfall. The increase and decrease in the aerosol concentration due to the convergence and divergence of the wind fields corresponded to the particles with diameters greater than $1{\mu}m$. It is found that the fluctuations in the aerosol number concentration are well correlated with the development and dissipation of snowfall radar echoes due to the convergence and divergence of horizontal wind fields near the surface boundary layer in the inland during the snowfall.

Effects of Kneading Concentration on Characteristics of HwBKP Fibers (니딩 처리 시 지료농도에 따른 활엽수표백크라프트펄프의 섬유특성 변화)

  • Seo, Ji-Hye;Choi, Kyoung-Hwa;Cho, Byoung-Uk
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.4
    • /
    • pp.54-59
    • /
    • 2015
  • In this study, effects of kneading concentration on characteristics of hardwood bleached kraft pulp (HwBKP) fibers were elucidated. A laboratory two-shaft kneader was utilized for kneading. Kneading concentration was varied in the range of 15-30% (w/w) and the number of kneading treatment was adjusted between 0 and 6 passes. It was found that kneading concentration influenced fiber characteristics. At 15% of pulp concentration, fiber length slightly increased with increasing the number of kneading passes, while other morphological properties such as fiber width and curl decreased: fiber straightening occurred. In addition, the increase in WRV and the decrease in CSF were the largest at 15% kneading concentration, meanings that fibrillation mainly occurred. In contrast, at higher kneading concentration exceeding 20%, fiber deformation like curl was mainly occurred. Also, at kneading concentration of 20% and 30%, fiber length decreased with the number of kneading passes while other morphological properties such as fiber width, and WRV increased. Severe fiber entanglement was found at 30% kneading, which shall be removed during papermaking.