• 제목/요약/키워드: Number Of Ventilation

검색결과 339건 처리시간 0.034초

Estimating Door Open Time Distributions for Occupants Escaping from Apartments

  • Hopkin, Charlie;Spearpoint, Michael;Hopkin, Danny;Wang, Yong
    • 국제초고층학회논문집
    • /
    • 제10권1호
    • /
    • pp.73-83
    • /
    • 2021
  • The door open time, resulting from occupants evacuating from apartments, is an important parameter when assessing the performance of smoke ventilation systems in high-rise apartment buildings. However, the values recommended in UK design guidance appear to have limited substantiation. Monte Carlo simulations have been carried out considering variabilities in door swing time, flow rate and number of occupants. It has been found that the door open time can be represented by a lognormal distribution with a mean of 6.6, 8.7 and 11.1 s and a standard deviation of 1.7, 3.2 and 4.7 s for one, two and three-bedroom apartments, respectively. For deterministic analyses, it is proposed that the 95th percentile values may be adopted in line with recommended practice for other fire safety design parameters such as fuel load density and soot yield, giving door open times of 10 s to 19 s, depending on the number of bedrooms.

추적가스를 이용한 실간환기량 산정방법에 따른 불확실성 해석 (Uncertainty Analysis of Interzonal Airflow Rates by Tracer Gas Methods)

  • 한화택;조석효
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.529-534
    • /
    • 2008
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

  • PDF

수평 상향 분사 덕트를 이용한 컨테이너선 화물창 환기 개선에 대한 실험적 연구 (An Experimental Study Improving Ventilation of Container Ship Hold Using Horizontal Upward Jet Duct)

  • 박일석;박상민;하지수
    • 대한조선학회논문집
    • /
    • 제43권2호
    • /
    • pp.236-245
    • /
    • 2006
  • The ventilation performance for the various venting duct arrays has been experimentally compared in the scaled model of the container hold. Most container ships have the ventilation duct system to remove effectively the condensing heat released from container refrigerator. The existing duct system is vertically installed and basically has the number of duct as many as the columns of reefer container stack. In this study, to make up for the weak points having stagnantly hot legions in the centered area of container hold for the present system, the horizontal upward jotting duct system was proposed and proved by temperature rising tests on the scaled model. In this paper, the expected flow regimes and the thermal and hydrodynamic analogies as well as the measured temperature distributions in a hold for various duct types and heat released rates are deeply discussed.

실간환기량 측정을 위한 추적가스 실험방법론에 관한 연구 (A Study on Tracer Gas Methodology to Measure Interzonal Airflow Rates)

  • 한화택;조석효
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.606-612
    • /
    • 2009
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

Association between Medical Costs and the ProVent Model in Patients Requiring Prolonged Mechanical Ventilation

  • Roh, Jiyeon;Shin, Myung-Jun;Jeong, Eun Suk;Lee, Kwangha
    • Tuberculosis and Respiratory Diseases
    • /
    • 제82권2호
    • /
    • pp.166-172
    • /
    • 2019
  • Background: The purpose of this study was to determine whether components of the ProVent model can predict the high medical costs in Korean patients requiring at least 21 days of mechanical ventilation (prolonged mechanical ventilation [PMV]). Methods: Retrospective data from 302 patients (61.6% male; median age, 63.0 years) who had received PMV in the past 5 years were analyzed. To determine the relationship between medical cost per patient and components of the ProVent model, we collected the following data on day 21 of mechanical ventilation (MV): age, blood platelet count, requirement for hemodialysis, and requirement for vasopressors. Results: The mortality rate in the intensive care unit (ICU) was 31.5%. The average medical costs per patient during ICU and total hospital (ICU and general ward) stay were 35,105 and 41,110 US dollars (USD), respectively. The following components of the ProVent model were associated with higher medical costs during ICU stay: age <50 years (average 42,731 USD vs. 33,710 USD, p=0.001), thrombocytopenia on day 21 of MV (36,237 USD vs. 34,783 USD, p=0.009), and requirement for hemodialysis on day 21 of MV (57,864 USD vs. 33,509 USD, p<0.001). As the number of these three components increased, a positive correlation was found betweeen medical costs and ICU stay based on the Pearson's correlation coefficient (${\gamma}$) (${\gamma}=0.367$, p<0.001). Conclusion: The ProVent model can be used to predict high medical costs in PMV patients during ICU stay. The highest medical costs were for patients who required hemodialysis on day 21 of MV.

A Study on the Perception Level and Proper Management of Indoor Air Quality Recognition in Elderly Care Hospital Workers

  • Choi, Mi-Suk
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권11호
    • /
    • pp.171-178
    • /
    • 2019
  • 본 연구에서는 노인요양병원의 실내공기질 관리계획을 제안하고자 노인요양병원의 실내공기질 수준을 측정하고 근무자의 실내공기질에 대한 인식에 대하여 조사하였다. 측정 항목은 온도, 습도, CO2, CO, PM10, VOC이며 2019년 4월 26일에 실시하였다. 설문 조사에 따르면 실내 공기질에 대한 만족도가 낮을수록 실외 공기질이 더 좋다고 응답하였으며 실내환경 요소 중 악취가 가장 낮은 것으로 응답하였으며 실내 공기질의 만족도가 높을 경우 실내환경 요소의 만족도도 높은 것으로 분석되었다. 다중응답 분석결과 "환기 부족"이었고 회귀 분석 결과 "공기질 관련성" 항목이 가장 낮은 것으로 분석되었다. 노인 요양 병원의 실내 공기질 환경을 최고 수준으로 유지하려면 냄새를 제거하기 위한 환기 장지를 추가로 설치하고 자연 환기 횟수를 늘리고 정기적인 환기담당자를 지정해야 할 것으로 판단된다. 이러한 계획을 수립함으로써 노인요양병원 근무자에게 최상의 서비스를 제공하기 위한 실내 공기질 환경을 제공 할 수 있다.

옥내저탄장 기류 흐름 및 환기량 분석을 통한 내부 유동 평가 (Evaluation of Internal through Analysis of Airflow and Ventilation of Coal Storage Shed)

  • 조현정;이진홍
    • 환경영향평가
    • /
    • 제31권5호
    • /
    • pp.334-342
    • /
    • 2022
  • 대기환경보전법이 강화되면서 야외저탄장을 옥내화 함으로써 외부로 날리는 비산먼지는 감소했지만, 저탄장에서 발생하는 석탄 비산먼지와 유해물질들을 단순히 격리함으로서 이러한 물질들이 내부에 축적되어 또 다른 문제를 야기할 수 있다. 본 연구는 이를 해결하기 위해 운영 중인 옥내 저탄장을 선정하여 내부 기류 흐름 양상과 환기량을 분석하였다. 옥내저탄장 내부 기류는 전반적으로 지형적으로 산 쪽에 접한 남서쪽으로 이동하는 경향을 보였다. 그리고 바다와 접한 북쪽 루버에서는 해풍에 의한 기류가 유입되고 있었다. 옥내저탄장 내부로 유입되는 총 유량은 918,691m3/h, 시간당 자연환기 횟수는 0.6회로 나타났다. 연구 결과를 바탕으로 내부 기류가 집중되는 위치에 강제 환기장치를 설치하는 것을 제안한다.

이산화티탄 광촉매 환기장치의 오염물질 저감 실험 (Experiment on Reduction of Pollutants in Titanium Dioxide Photocatalytic Ventilation System)

  • 송용우
    • 토지주택연구
    • /
    • 제13권2호
    • /
    • pp.117-123
    • /
    • 2022
  • 본 연구는 대표적인 미세먼지와 실내유해물질인 질소산화물의 저감을 위해 이산화티탄 광촉매를 환기장치에 적용한 것으로 그 내용은 다음과 같다. 기존 연구는 실내에 자외선 적용의 한계로 인해 주로 건축자재에 광촉매 혼입을 통해 실외 자재를 대상으로 진행되었다. 자외선 실내 적용 한계를 극복하고자 기존 선행연구를 통해 확인된 이산화티탄 광촉매의 오염물질 분해 효과를 실내에 적용이 가능하도록 자외선램프의 설치가 가능한 반응장치를 설계 및 제작하였다. 해당 반응장치를 실내 환기장치에 적용하여 Mock-Up에 적용하였다. Mock-Up 실험은 그 체적을 시간당 1회, 5회 환기하는 풍량을 변화시켜 NOx 저감 성능을 확인하였다. 그 결과, 환기 풍량이 증가함에 따라 NOx 저감시간이 비례하여 감소되어 그 성능이 증가하는 것을 확인하였다. 해당 연구를 통해 오염물질 저감 효과를 가진 이산화티탄 광촉매의 실내 활용 방안과 그 성능을 확인할 수 있는 기초적인 연구 결과를 도출하였다.

네트워크형 복층 터널 환기 시스템 설계 인자 (Design Factors for the Ventilation System of a Networked Double-deck Tunnel)

  • 박상훈;이승준;박요한;김세민;노장훈;유용호;김진
    • 터널과지하공간
    • /
    • 제26권1호
    • /
    • pp.32-45
    • /
    • 2016
  • 전 세계적으로 도심지 공간의 효율적인 활용을 위한 지하 공간 이용방안에 대해 연구가 진행되어 왔고 미국, 유럽, 중국 등이 복층터널을 건설하여 운영 중이다. 대표적으로, 프랑스의 A86 East, 말레이시아 SMART 터널, 스페인 M30 프로젝트, 미국 시애틀 SR99, 중국 상하이 양쯔강 터널 등을 예로 들 수 있다. 이에 따라서 국내에서도 교통집중을 해소하고 지상 공간 확보를 위해 대심도에 위치하는 네트워크형 복층도로터널 운영에 대한 연구가 진행되고 있다. 그러므로 본 연구에서는 기존에 사용하고 있는 일반적인 도로터널의 환기설계 아웃라인의 리뷰를 통해 대심도 복층터널에 추가적으로 필요한 다양한 요소들을 분석해보고, 해외 복층 도로터널설계사례들을 자세히 검토하여 환기방식과 종류에 따른 환기설계인자분석을 통해 네트워크형 복층 도로터널에 적용 가능한 설계인자를 도출해내고 특징적인 환기설계인자를 새롭게 정립해 본다.

미세먼지 저감대책으로서 바람길 적용 방안 : 세종시를 대상으로 (Application of Ventilation Corridor to Mitigate Particulate Matter for the Sejong-Si)

  • 남성우;성선용;박종순
    • 한국콘텐츠학회논문지
    • /
    • 제20권3호
    • /
    • pp.1-9
    • /
    • 2020
  • 본 연구에서는 내륙 분지에 위치하여 대기 정체율이 높은 세종시를 대상으로 미세먼지의 저감을 위한 바람길의 적용방안을 도출하고 정책적 대안을 제시하였다. 도시내 바람길의 도입을 위해서는 첫째, 신도시 건설에 따른 신선한 대기의 변화 흐름을 파악하고 둘째, 도시공간에서 바람길을 확보함으로써 대기순환을 촉진해야 함을 밝혀낼 수 있었다. 본 연구에서는 미세먼지 저감 효과를 검증하기 위하여 전산유체역학모형을 활용하였다. 구체적으로는 도시 건설 전과 후의 탁월풍의 풍속, 풍향 변화와 일몰 후 생성된 시원한 공기가 낮은 지대를 따라 흐르는 특성이 분석되었다. 이와 더불어 블록단위에서 바람길과 순응하는 건축물을 배치 시 미세먼지 저감 효과를 정량적으로 검증하였다. 모의실험을 통해 제시 가능한 정책적 함의는 다음과 같다. 첫째, 산, 숲, 골짜기에서 내려오는 신선한 공기가 도시 안으로 원활히 유입, 분산되어 미세먼지 농도를 낮출 수 있도록 바람 통로를 조성하고, 적절한 건축물 배치계획을 수립한다. 둘째, 미세먼지 농도가 낮은 지역에는 공원, 광장, 놀이터 등 공공시설들을 우선적으로 설치하여 미세먼지로부터 안전한 옥외활동을 유인하도록 한다. 마지막으로, 지구단위계획 등 도시계획 수립 과정에서 바람길 분석을 통해 최적의 대안을 마련할 것을 제안한다.