• 제목/요약/키워드: Nuclear medicine image

검색결과 615건 처리시간 0.029초

종양 영상을 위한 PET 방사성의약품 (PET Radiopharmaceuticals for Tumor Imaging)

  • 최연성
    • 대한핵의학회지
    • /
    • 제36권1호
    • /
    • pp.8-18
    • /
    • 2002
  • Early and accurate diagnosis of tumors using positron omission tomography (PET) has been the focus of considerable interest due to its high metastasis and mortality rates at late detection. PET radiopharmaceuticals-which exhibit a high tumor-to-background uptake ratio, and appropriate metabolic characteristics, and pharmacokinetics-are attractive tools for tumor imaging. Tumor imaging by these radiopharmaceuticals are based on metabolic and receptor imaging. The former is based on accelerated metabolism in tumor tissue compared to normal tissue and the rate roughly corresponding to the rate of growth of tumors. Radiopharmaceuticals for this purpose include radiolabeled sugars, amino acids, and nucleosides which detect increased glucose utilization, protein synthesis, and DNA synthesis, respectively. Tumor receptor imaging is based on the proliferation of tumor cells regulated by many hormones and growth factors, which bind to the corresponding receptors and exhibit the biological responses Radiopharmaceuticals used to image the tumor receptor systems may be ligands for the specific receptors and antibodies for the growth factor receptors. Some antitumor agents have been labeled with radionuclides and used to study in vivo biodistribution and pharmacokinetics in humans. This overview describes typical PET radiopharmaceuticals used for tumor imaging based on their uptake mechanisms.

I-123 MIBG Cardiac SPECT의 임상적 적응증 (Clinical Application of I-123 MIBG Cardiac Imaging)

  • 강도영
    • 대한핵의학회지
    • /
    • 제38권5호
    • /
    • pp.331-337
    • /
    • 2004
  • Cardiac neurotransmission imaging allows in vivo assessment of presynaptic reuptake, neurotransmitter storage and postsynaptic receptors. Among the various neurotransmitter, I-123 MIBG is most available and relatively well-established. Metaiodobenzylguanidine (MIBG) is an analogue of the false neurotransmitter guanethidine. It is taken up to adrenergic neurons by uptake-1 mechanism as same as norepinephrine. As tagged with I-123, it can be used to image sympathetic function in various organs including heart with planar or SPECT techniques. I-123 MIBG imaging has a unique advantage to evaluate myocardial neuronal activity in which the heart has no significant structural abnormality or even no functional derangement measured with other conventional examination. In patients with cardiomyopathy and heart failure, this imaging has most sensitive technique to predict prognosis and treatment response of betablocker or ACE inhibitor. In diabetic patients, it allow very early detection of autonomic neuropathy. In patients with dangerous arrhythmia such as ventricular tachycardia or fibrillation, MIBG imaging may be only an abnormal result among various exams. In patients with ischemic heart disease, sympathetic derangement may be used as the method of risk stratification. In heart transplanted patients, sympathetic reinnervation is well evaluated. Adriamycin-induced cardiotoxicity is detected earlier than ventricular dysfunction with sympathetic dysfunction. Neurodegenerative disorder such as Parkinson's disease or dementia with Lewy bodies has also cardiac sympathetic dysfunction. Noninvasive assessment of cardiac sympathetic nerve activity with I-123 MIBG imaging nay be improve understanding of the pathophysiology of cardiac disease and make a contribution to predict survival and therapy efficacy.

류마티스 질환에서 골스캔의 역할 (Role of Bone Scan in Rheumatic Diseases)

  • 최윤영
    • 대한핵의학회지
    • /
    • 제37권3호
    • /
    • pp.137-146
    • /
    • 2003
  • Rheumatic diseases can be categorized by pathology into several specific types of musculoskeletal problems, including synovitis (e.g. rheumatoid arthritis), enthesopathy (e.g. ankylosing spondylitis) and cartilage degeneration (e.g. osteoarthritis). Skeletal radiographs have contributed to the diagnosis of these articular diseases, and some disease entities need typical radiographic changes as a factor of the diagnostic criteria. However, they sometimes show normal radiographic findings in the early stage of disease, when there is demineralization of less than 30-50 %. Bone scans have also been used in arthritis, but not widely because the findings are nonspecific and it is thought that bone scans do not add significant information to routine radiography. Bone scans do however play a different role than simple radiography, and it is a complementary imaging method in the course of management of arthritis. The Image quality of bone scans can be improved by obtaining regional views and images under a pin-hole collimator, and through a variety of scintigraphic techniques including the three phase bone scan and bone SPECT. Therefore, bone scans could improve the diagnostic value, and answer multiple clinical questions, based on the pathophysiology of various forms of arthritis.

자기공명촬영상에서 구한 내부 전류밀도를 이용한 임피던스 단층촬영법 (Impedance Tomography using Internal Current Density Distribution Measured by Nuclear Magnetic Resonance)

  • 이수열;우응제;문치웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권4호
    • /
    • pp.413-418
    • /
    • 1994
  • In electrical impedance tomography (EIT), we use boundary current and voltage measurements to provide the information about the cross-sectional distribution of electrical impedance or resistivity One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.7T NMR machine. We implemented a resistivity image reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the image reconstruction algorithm and furture direction of the research.

  • PDF

환자의 만족도 향상을 위한 PET/CT Volume Rendering Technique 적용 (Application of PET/CT Volume Rendering Technique to Improve Patient Satisfaction)

  • 장동근;이상호
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.877-881
    • /
    • 2021
  • 우리나라 의료 시스템에서 고객만족은 매우 중요한 요소로 자리 잡고 있다. 하지만, 의료영상 분야는 일반인들이 이해하기 매우 어려운 부분이 있다. 이에 본 연구에서는 의료진과 환자의 소통문제를 해결하기 위한 방안으로 기존의 PET/CT 단면 의료영상을 Volume Rendering Technique으로 재구성 하여 환자의 만족도를 증가시키고자 하였다. PET/CT 검사를 진행한 암 환자 360명을 대상으로 VRT을 진행하였으며, 이 중 100명의 환자를 대상으로 만족도 조사를 실시한 결과 100명 모두 VRT 영상이 기존의 영상보다 만족도가 우수한 것으로 나타났다. PET/CT는 CT 나 MRI와 같은 세부적인 해부학적 모양을 관찰하는 장비가 아닌 암의 신호를 강하게 나타내는 영상으로 손쉽게 VRT 영상이 제작 가능하다. 이러한 VRT 영상은 일반인들도 쉽게 이해할 수 있도록 입체적으로 표현 할 수 있어 의료진과 환자의 소통을 보다 효율적으로 높일 수 있으며 환자의 "알 권리" 충족시킬 것으로 나타났다.

Quantitative Evaluation of Setup Error for Whole Body Stereotactic Radiosurgery by Image Registration Technique

  • Kim, Young-Seok;Yi, Byong-Yong;Kim, Jong-Hoon;Ahn, Seung-Do;Lee, Sang-wook;Im, Ki-Chun;Park, Eun-Kyung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.103-105
    • /
    • 2002
  • Whole body stereotactic radiosurgery (WBSRS) technique is believed to be useful for the metastatic lesions as well as relatively small primary tumors in the trunk. Unlike stereotactic radiosurgery to intracranial lesion, inherent limitation on immobilization of whole body makes it difficult to achieve the reliable setup reproducibility. For this reason, it is essential to develop an objective and quantitative method of evaluating setup error for WBSRS. An evaluation technique using image registration has been developed for this purpose. Point pair image registrations with WBSRS frame coordinates were performed between two sets of CT images acquired before each treatment. Positional displacements could be determined by means of volumetric planning target volume (PTV) comparison between the reference and the registered image sets. Twenty eight sets of CT images from 19 WBSRS patients treated in Asan Medical Center have been analyzed by this method for determination of setup random error of each treatment. It is objective and clinically useful to analyze setup error quantitatively by image registration technique with WBSRS frame coordinates.

  • PDF

18F-FDOPA Brain PET/CT 검사의 영상 대조도 분석 및 섭취 시간에 따른 SUV변화 고찰 (A Study on analysis of contrasts and variation in SUV with the passage of uptake time in 18F-FDOPA Brain PET/CT)

  • 서강록;이정은;고현수;류재광;남기표
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.69-74
    • /
    • 2019
  • $^{18}F$-FDOPA는 뇌 종양의 아미노산 대사를 추적하는 방사성 의약품이다. 본 연구의 목적은 뇌 종양의 아미노산 대사를 영상화 하여 악성 종양을 진단하는 $^{18}F$-FDOPA와 포도당 대사를 통한 $^{18}F$-FDG의 Brain PET/CT 검사 영상의 대조도 분석을 통해 병변의 검출 능력을 비교하고, $^{18}F$-FDOPA Brain PET/CT 검사에서 섭취 시간에 따른 SUV의 변화를 분석하여 최적의 영상 획득 시간을 알아보기 위함이다. $^{18}F$-FDOPA 와 $^{18}F$-FDG 두 영상에서 종양(Tumor)과 소뇌(Cerebellum)의 중심에 각각 약 $350mm^2$의 관심 영역을 설정하여 $SUV_{max}$를 측정하였고, 종양과 소뇌의 $SUV_{max}$ 비율(T/C ratio)을 산출하였고, $^{18}F$-FDOPA 투여 직후 30분 동안 획득한 리스트 수집 방식 데이터(List mode data)를 활용해 2분씩 15프레임으로 나눈 뒤 각 프레임 별로 종양과 소뇌 중심에 $SUV_{max}$를 측정하여 위와 동일한 방법으로 T/C ratio를 산출하여 분석하였다. 종양의 평균 $SUV_{max}$를 비교해 본 결과, $^{18}F$-FDOPA Brain PET/CT 검사에서 $4.2{\pm}0.8$, $^{18}F$-FDG Brain PET/CT 검사에서는 $5.6{\pm}0.7$ 이었다. 또한, T/C ratio는 $^{18}F$-FDOPA 검사에서 $2.1{\pm}0.7$, $^{18}F$-FDG 검사에서는 $1.1{\pm}0.4$ 이었으며, $^{18}F$-FDOPA의 $SUV_{max}$$^{18}F$-FDG보다 낮지만 T/C ratio는 높게 나타나 종양 구별 능력이 더욱 뛰어난 것을 알 수 있었다(t=-5.214, p=0.000). $^{18}F$-FDOPA의 섭취 시간에 따른 $SUV_{max}$와 T/C ratio를 분석한 결과, $SUV_{max}$와 T/C ratio의 Peak는 모두 6~8분에서 나타났다. 이를 토대로 본원에서 $^{18}F$-FDOPA Brain PET/CT 검사에서 활용하는 10~30분의 영상과 Peak가 나타나기 시작한 6~26분의 영상을 비교한 결과 SUV와 T/C ratio가 각각 0.2, 0.1 증가하였다. 추후 지속적인 연구를 통해 검사 소요시간의 단축 가능성과 추가적인 스캔 정보 활용을 통한 정확한 진단에도 도움이 될 것으로 사료된다.

감마카메라의 중장기 외인성 균일도 분석 (Long-Term Extrinsic Uniformity Analysis of Gamma Cameras)

  • 김윤재;정우영;이동훈
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.36-41
    • /
    • 2023
  • Purpose The long-term trend of extrinsic uniformity by type of gamma camera was analyzed, and the factors affecting uniformity were investigated. Based on this, the purpose was to predict the life of the gamma camera, pay attention to factors that affect uniformity, and obtain better quality images. Materials and methods Four of the gamma cameras in operation at a senior general hospital in Seoul were selected and the trend of extrinsic uniformity from the first operation date to the present was analyzed. In order to minimize various factors affecting uniformity, a detailed analysis was conducted by calculating the monthly and annual average of the uniformity values. Results Two Symbia E gamma cameras from SIEMENS, one Symbia Evo Excel gamma camera, and one Symbia Intevo16 gamma camera were selected and analyzed. The uniformity of Symbia E1 (2012 warehousing) changed unevenly, and the uniformity of Symbia E2 (2014 warehousing) changed according to the replacement cycle of 57Co sheet sources. The uniformity of Symbia Evo Excel (received in 2017) and Symbia Intevo 16 (received in 2017) was constant compared to Symbia E. Conclusion The extrinsic uniformity of the gamma camera gradually increased over time. However, there was a difference in uniformity for each type of gamma camera, and there was a change in uniformity in which the cause could not be accurately identified. In order to improve the quality of the image, it is necessary to periodically check changes in uniformity and minimize factors that affect uniformity.

  • PDF

Thyroid imaging in 53 cats with hyperthyroidism using technetium-99m as pertechnetate

  • Lee, Young-won
    • 대한수의학회지
    • /
    • 제39권2호
    • /
    • pp.394-397
    • /
    • 1999
  • Thyroid imaging was performed in 53 hyperthyroid cats with technetium-99m as pertechnetate($^{99m}TcO_{4}$). Increased radionuclide accumulation was found in all cats. Thirty-four cats had bilateral enlargements of the thyroid glands and 14 cats had unilateral enlargements. Five cats had multi-focal accumulation of $^{99m}TcO_{4}$ in the ventral neck or mediastinum. Conclusively, nuclear thyroid image is useful method in diagnosis of feline hyperthyroidism.

  • PDF

뇌경색 환자에서 뇌종양과 유사한 Tc-99m tetrofosmin의 섭취 (Cerebral Infarction Mimicking Brain Tumor on Tc-99m Tetrofosmin Brain SPECT imaging)

  • 김순;전석길;원경숙
    • 대한핵의학회지
    • /
    • 제38권3호
    • /
    • pp.268-271
    • /
    • 2004
  • A 43-year-old man was presented with persistent headache for two weeks. 72 weighted MR imaging showed high signal intensity with surrounding edema in the left frontal lobe. These findings were considered with intracranial tumor such as glioma or metastasis. Tc-99m tetrofosmin SPECT showed focal radiotracer accumulation in the left frontal lobe. The operative specimen contained cerebral infarction with organizing leptomeningeal hematoma by pathologist. Another 73-year-old man was hospitalized for chronic headache. Initial CT showed ill-defined hypodensity with mass effect in the right parietal lobe. Tc-99m tetrofosmin SPECT showed focal radiotracer uptake in the right parietal lobe. These findings were considered with low-grade glioma or infarction. Follow-up CT after 5 months showed slightly decreased in size of low density in the right parietal lobe, and cerebral infarction is more likely than others. Tc-99m tetrofosmin has been proposed as a cardiotracer of myocardial perfusion imaging and an oncotropic radiotracer. Tc-99m tetrofosmin SPECT image provides a better attractive alternative agent than T1-201 as a tumor-imaging agent, with characteristics such as high-energy flux, short half-life, favorable biodistribution, dosimetry and lower background radioactivity. We have keep in mind on the analysis of Tc-99m tetrofomin imaging when cerebral infarction is being differentiated from brain tumor.