Assessment of Attenuation Correction Algorithms With a $^{137}$Cs Point Source (Cs-137 점선원을 이용한 감쇠보정기법들에 대한 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Park, Hae-Jung;Kwon, Yun-Youn;Son, Hye-Kyoung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.96-99
    • /
    • 2004
  • The objective of this study is to assess attenuation correction algorithms utilized in a multipurpose whole-body GSO PET scanner. Four different types of phantoms were tested using different types of attenuation correction techniques. FOV (Field of View) of 256mm was used for brain PET imaging. For compensating attenuation, transmission data of a $^{137}$Cs point source were acquired after the F-18 emission source was infused to the phantoms. Scatter correction were peformed. Reconstructed images of the phantoms were assessed. In addition, reconstructed images of a normal subject were compared and assessed by nuclear medicine physicians. As a result, decreased intensity at the central portion of the attenuation map with cylindrical phantom was noticed during use of the measured attenuation correction. On the other hand, segmentation or remapping attenuation correction provided uniform phantom image. the images reconstructed from the clinical brain data explained the attenuation of a skull, at though reconstructed images of the phantoms couldn't explain it. in conclusion, the complicated and improved attenuation correction methods were required to obtain the better accuracy of the quantitative brain PET images. Our study will be useful in improving quantitative brain PET imaging modalities with attenuation correction of $^{137}$Cs transmission source.

  • PDF

Performance Evaluation of Substitution Radiopharmaceutical according to Restriction of the Radiocolloids in Lymphoscintigraphy (Lymphoscintigraphy에 이용되는 방사성의약품의 사용제한으로 인한 대체 방사성의약품의 성능평가)

  • Seo, Young-Deok;Jeong, Jae-Hun;Moon, Jong-Woon;Yun, Sang-Hyeok;Kim, Yeong-Seok;Kang, Se-Hun;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.25-29
    • /
    • 2009
  • Purpose: Several radioactive agents were used for lymphoscintigraphy in breast cancer. But recently, due to the change of local radiopharmaceutical licensing policy and discontinuation of supplies from manufacturer, we could not use many radiocolloids such as $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, $^{99m}Tc$-Human Serum Albumin. So it is necessary to use the substitution radiopharmaceutical. Therefore, this study aims to evaluate the performance of substitution radiopharmaceutical ($^{99m}Tc$-Phytate) including the existing radiocolloids and to set up of the appropriate protocol in lymphoscintigraphy. Materials and Methods: For each radiocolloids ($^{99m}Tc$-Antimony Trisulfide Colloid (ASC), $^{99m}Tc$-Tin Colloid (TC), $^{99m}Tc$-Human Serum Albumin (HSA), $^{99m}Tc$-Phytate) were performed the particle size by Zeta Sizer (Nano-ZS) and we compared the radiolabeling time, procedure and acquisition time for each of the radiocolloids (total 200 patients). For the last time, we made an analysis of image for each of the radiocolloids with our previous report (SJ Jang et al, Korean Nucl Med Mol imaging Vol.41, No.6, Dec 2007). Results: The particle size of each radiocolloids showed A.S.C (50 nm), T.C (310 nm), H.S.A (10.8 nm), $^{99m}Tc$-Phytate (499 nm). The labeling and acquisition time for each of the radiocolloids showed no substantial difference. But there is difference of the labeling time for the A.S.C. because the ASC procedure need to boiling process. There were no significant differences among those radiocolloids (p>0.005) in the identification rate (IR), false negative rate (FNR), and negative predictive value (NPV). Conclusions: $^{99m}Tc$-labeled radiocolloids showed equivalent results in lymphoscintigraphy. Therefore, in this exam of each radiocolloids could be applied appropriate protocol in lymphoscintigraphy.

  • PDF

Production of the Recombinant Single Chain Anti-B Cell Lymphoma Antibody and Evaluation of Immunoreactivity (pET vector를 통한 유전자 재조합 단일사슬 항 B형 림프종 항체의 생산과 면역반응성 평가)

  • Jung, Jae-Ho;Choi, Tae-Hyun;Woo, Kang-Sun;Chung, Wee-Sup;Kim, Soo-Gwan;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.211-217
    • /
    • 2006
  • Purpose: Recombinant ScFv lym-1 was produced, using pET vector system for large scale production. Methods: ScFv lym-1 gene inserted pET-22b (+) vector, was expressed in E.coli BL-21 strain. ScFv lym-1 antibody extracted from periplasm, was purified with His-Taq column. To evaluated immunoreactivity with Raji cell, ScFv lym-1 was labeled with I-125 and I-125 ScFv lym-1 was purified with desalting column. Raji cell was injected into the C57BR/cdJ SCID mice. Gamma camera imaging were taken time point at 1, 8, 24, and 48 hr with 8 mm pinhole collimator. Results: An active scFv lym-1 could be produced in E. coli with soluble iron using PET vector system. Immuuoreaetivity and affinity constant of IgG lym-1 were 54% and $1.83{\times}10^9M^{-1}$, respectively, and those of scFv lym-1 were 53.7% and $1.46{\times}10^9M^{-1}$, respectively. Biodistribution of I-125 scFv lym-1 antibody showed faster clearance in blood, spleen, kidney and than I-125 IgG lym-1 antibody. Gamma camera image of I-125 scFv lym-1 antibody showed faster clearance and tumor targeting liver than I-125 IgG lym-1 antibody. Conclusions: In vitro properties of scFv lym-1 were similar to those of IgG lym-1. ScFv lym-1 showed faster blood clearance than IgG lym-1 There results suggest that scFv lym-1 antibody can be useful for tumor imaging agent.

Evaluation of Result of CABG by Comparison of Pre-and Post-operative Myocardial SPECT (관동맥우회로술 전후의 디피리다몰 부하/휴식 심근 SPECT를 이용한 수술 결과의 평가)

  • Lee, Dong-Soo;Lee, Won-Woo;Kang, Keon-Wook;Hyun, In-Young;Kim, Ki-Bong;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.86-94
    • /
    • 1996
  • Coronary angiography should be performed to verify the patency of bypass graft if coronary artery disease is said to be surgically corrected. Rest/stress myocardial SPECT could be used as a noninvasive alternative to prove patency of bypass graft and functional significance of graft patency by showing improvement of rest perfusion and perfusion reserve after operation. We evaluated the outcome of coronary artery bypass graft surgery by comparing rest/dipyridamole-stress myocardial SPECT before and after operation. Myocardial SPECT were performed $19{\pm}23$ days before and $108{\pm}19$ days after operation in 44 patients(M:F=25:19). Segmental perfusion were scored with 0(normal) to 3(defect) independently for each image set of rest and stress. Perfusion scores were compared between pre and postoperative images. Rest/stress images of pre and post-operative SPECT were compared in paired sets. Postoperative change of perfusion was determined as no change, improvement or aggravation for each artery territory. Postoperative outcome of patients were analyzed. Overall, 74%(158 segments) of 215 segments which had perfusion decrease before operation showed improvement. Among 60 artery territories, 37 territories(62%) improved. Among 42 patients with perfusion decrease in preoperative SPECT, 21 patients(47%) improved after operation. Severe persistent defects improved in 43%(6/14). We concluded that bypass surgery improved myocardial perfusion in dipyridamole stress induced or persistent decrease and that rest/stress myocardial SPECT could be used as a guide for which artery should be operated.

  • PDF

The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT (PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.13-20
    • /
    • 2011
  • Purpose: The limited FOV(Field of View) of CT (Computed Tomography) can cause truncation artifact at external DFOV (Display Field of View) in PET/CT image. In our study, we measured the difference of SUV and compared the influence affecting to the image reconstructed with the extended DFOV. Materials and Methods: NEMA 1994 PET Phantom was filled with $^{18}F$(FDG) of 5.3 kBq/mL and placed at the center of FOV. Phantom images were acquired through emission scan. Shift the phantom's location to the external edge of DFOV and images were acquired with same method. All of acquired data through each experiment were reconstructed with same method, DFOV was applied 50 cm and 70 cm respectively. Then ROI was set up on the emission image, performed the comparative analysis SUV. In the clinical test, patient group shown truncation artifact was selected. ROI was set up at the liver of patient's image and performed the comparative analysis SUV according to the change of DFOV. Results: The pixel size was increase from 3.91 mm to 5.47 mm according to the DFOV increment in the centered location phantom study. When extended DFOV was applied, $_{max}SUV$ of ROI was decreased from 1.49 to 1.35. In case of shifted the center of phantom location study, $_{max}SUV$ was decreased from 1.30 to 1.20. The $_{max}SUV$ was 1.51 at the truncated region in the extended DFOV. The difference of the $_{max}SUV$ was 25.9% higher at the outside of the truncated region than inside. When the extended DFOV was applied, $_{max}SUV$ was decreased from 3.38 to 3.13. Conclusion: When the extended DFOV was applied, $_{max}SUV$ decreasing phenomenon can cause pixel to pixel noise by increasing of pixel size. In this reason, $_{max}SUV$ was underestimated. Therefore, We should consider the underestimation of quantitative result in the whole image plane in case of patient study applied extended DFOV protocol. Consequently, the result of the quantitative analysis may show more higher than inside at the truncated region.

  • PDF

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Effects of Motion Correction for Dynamic $[^{11}C]Raclopride$ Brain PET Data on the Evaluation of Endogenous Dopamine Release in Striatum (동적 $[^{11}C]Raclopride$ 뇌 PET의 움직임 보정이 선조체 내인성 도파민 유리 정량화에 미치는 영향)

  • Lee, Jae-Sung;Kim, Yu-Kyeong;Cho, Sang-Soo;Choe, Yearn-Seong;Kang, Eun-Joo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.413-420
    • /
    • 2005
  • Purpose: Neuroreceptor PET studies require 60-120 minutes to complete and head motion of the subject during the PET scan increases the uncertainty in measured activity. In this study, we investigated the effects of the data-driven head mutton correction on the evaluation of endogenous dopamine release (DAR) in the striatum during the motor task which might have caused significant head motion artifact. Materials and Methods: $[^{11}C]raclopride$ PET scans on 4 normal volunteers acquired with bolus plus constant infusion protocol were retrospectively analyzed. Following the 50 min resting period, the participants played a video game with a monetary reward for 40 min. Dynamic frames acquired during the equilibrium condition (pre-task: 30-50 min, task: 70-90 min, post-task: 110-120 min) were realigned to the first frame in pre-task condition. Intra-condition registrations between the frames were performed, and average image for each condition was created and registered to the pre-task image (inter-condition registration). Pre-task PET image was then co-registered to own MRI of each participant and transformation parameters were reapplied to the others. Volumes of interest (VOI) for dorsal putamen (PU) and caudate (CA), ventral striatum (VS), and cerebellum were defined on the MRI. Binding potential (BP) was measured and DAR was calculated as the percent change of BP during and after the task. SPM analyses on the BP parametric images were also performed to explore the regional difference in the effects of head motion on BP and DAR estimation. Results: Changes in position and orientation of the striatum during the PET scans were observed before the head motion correction. BP values at pre-task condition were not changed significantly after the intra-condition registration. However, the BP values during and after the task and DAR were significantly changed after the correction. SPM analysis also showed that the extent and significance of the BP differences were significantly changed by the head motion correction and such changes were prominent in periphery of the striatum. Conclusion: The results suggest that misalignment of MRI-based VOI and the striatum in PET images and incorrect DAR estimation due to the head motion during the PET activation study were significant, but could be remedied by the data-driven head motion correction.

A Study on the Determination of Scan Speed in Whole Body Bone Scan Applying Oncoflash (Oncoflash를 적용한 전신 뼈 영상 검사의 스캔 속도 결정에 관한 연구)

  • Yang, Gwang-Gil;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.56-60
    • /
    • 2009
  • Purpose: The various studies and efforts to develop program are in progress in the field of nuclear medicine for the purpose of reducing scan time. The Oncoflash is one of the programs used in whole body bone scan which allows to maintain the image quality while to reduce scan time. When Those applications are used in clinical setting, both the image quality and reduction of scan time should be considered, therefore, the purpose of this study was to determine the criteria for proper scan speed. Materials and Methods: The subjects of this study were the patients who underwent whole body bone scan at the departments of nuclear medicine in the Asan Medical Center located in Seoul from 1st to 10th, July, 2008. The whole body bone images obtained in the scan speed of 30cm/min were classified by the total counts into under 800 K, and over 800 K, 900 K, 1,000 K, 1,500 K, and 2,000 K. The image quality were assessed qualitatively and the percentages of those of 1,000K and under of total counts were calculated. The FWHM before and after applying the Oncoflash were analyzed using images obtained in $^{99m}Tc$ Flood and 4-Quadrant bar phantom in order to compare the resolution according to the amount of total counts by the application of the Oncoflash. Considering the counts of the whole body bone scan, the dosed 2~5 mCi were used. 152 patients underwent the measurement in which the counts of Patient Postioning Monitor (PPM) were measured with including head and the parts of chest which the starting point of whole body bone scan from 7th to 26th, August, 2008. The correlations with total counts obtained in the scan speed of 30cm/min among them were analyzed (The exclusion criteria were after over six hours of applying isotopes or low amount of doses). Results: The percentage of the whole body bone image which has the geometric average of total counts of under 1,000K among them obtained in the scan speed of 30cm/min were 17.6%(n=58) of 329 patients. The qualitative analysis of the image groups according to the whole body counts showed that the images of under 1,000K were assessed to have coarse particles and increased noises. The analysis on the FWHM of the images before and after applying the Oncoflash showed that, in the case of PPM counts of under 3.6 K, FWHM values after applying the Oncoflash were higher than that before applying the Oncoflash, whereas, in the case of that of over 3.6 K, the FWHM after applying the Oncoflash were not higher than that before applying the Oncoflash. The average of total counts at 2.5~3.0 K, 3.1~3.5 K, 3.6~4.0 k, 4.1~4.5 K, 4.6~5.0 K, 5.1~6.0 K, 6.1~7.0 K, and 7.1 K over (in PPM) were $965{\pm}173\;K$, $1084{\pm}154\;K$, $1242{\pm}186\;K$, $1359{\pm}170\;K$, $1405{\pm}184\;K$, $1640{\pm}376\;K$, $1,771{\pm}324\;K$, and $1,972{\pm}385\;K$, respectively and the correlations between the counts in PPM and the total counts of image obtained in the scan speed of 30 cm/min demonstrated strong correlation (r=.775, p<.01). Conclusions: In the case of PPM coefficient over 3.6 K, the image quality obtained in the scan speed of 30cm/min and after applying the Oncoflash was similar to that obtained in the scan speed of 15 cm/min. In the case of total counts over 1,000 K, it is expected to reduce scan time without any damage on the image quality. In the case of total counts under 1,000 K, however, the image quality were decreased even though the Oncoflash is applied, so it is recommended to perform the re-image in the scan speed of 15 cm/min.

  • PDF

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam (PET/CT 검사 환자의 피폭선량 경감을 위한 연구)

  • Kim, Bong-Su;Pyo, Sung-Jai;Cho, Yong-Gyi;Shin, Chai-Ho;Cho, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.10-16
    • /
    • 2009
  • Purpose: As the number of patients has increased since the installation of a PET/CT, we are now examining about 2500-3000 annually. We have realized that if we properly adjust a pitch under the same condition of a CT during a PET/CT exam, radiation quantity that reaches the patient can change. In order to reduce the exposure dose of a patient, the research examines a method of reducing the exposure dose of a patient by controlling the pitch during a PET/CT exam, viewing whether the adjustment of the pitch influences CT image and PET SUV. Methods: The equipment used is a Biograph Positron Emission Tomography (PET) Scanner (CT type: TRCT-240-130 (WCT-240-130)) of Siemens company. For the evaluation of exposure dose of a patient, we measured radiation quantities using a PTW-DIADOS 11003/1383, which is a CT radiation measurement instrument used by Siemens. We measured and analyzed the space resolutions of CT images caused by the change of pitches using an AAPM Standard Phantom in order to see how the adjustment of pitches influenced the CT images. In addition, in order to obtain SUVs caused by each change of pitches using a PET source made with a solid radioactive cylinder phantom, we confirmed whether the SUVs changed in the PET/CT images by calculating the SUVs of the fusion images caused by the change of pitches after obtaining CT and PET images and finishing the test. Results: 2slice CT scanner showed that radiation quantities largely dropped when pitches ranged from 0.7 to 1.3 and that the reduction of radiation quantities were smaller when pitches ranged from 1.5 to 1.9. That is, we found that the bigger pitch values are the smaller the radiation quantities of a patient are. Moreover, we realized that there is no change of SUVs caused by the increase of pitches and that pitch values do not influence PET SUVs and the quality of CT images. It is judged that using 1.5 as a pitch value contributes to the reduction of exposure dose of a patient as long as there is no problem in the quality of an image. Conclusions: When seeing the result of the research, hospital using a PET/CT should make an effort to reduce the exposure dose of a patient seeking pitch values appropriate for their hospital within the range in which there is no image distortion and PET SUVs are not influenced from pitches. We think that the research can apply to all multi-detectors having a CT scanner and that such a research will be needed for other equipments in the future.

  • PDF