• 제목/요약/키워드: Nozzle scanning

검색결과 60건 처리시간 0.022초

Powder Blasting 에 의한 유리의 미세 홈 가공시 노즐 주사횟수의 영향 (Effect of Nozzle Scanning in Micro Grooving of Glass by Powder Blasting)

  • 김광현;최종순;박동삼
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1280-1287
    • /
    • 2002
  • The old technique of sandblasting which has been used for decoration of glass surface has recently been developed into a powder blasting technique for brittle materials such as glass, silicon and ceramics, capable of producing micro structures larger than $100{\mu}$ m. This paper describes the performance of powder blasting technique in micro-line grooving of glass and the effect of the number of nozzle scanning on the depth and width of line groove. Experimental results showed that increasing the no. of nozzle scanning resulted in the increase of depth and width in grooves. Increase of width which may cause several problems in the precision machining results from wear of mask film. Therefore, well-controlled masking process is the most important factor for micro machining of glass with accuracy.

Powder Blasting을 이용한 유리의 미세 선형 홈 가공시 노즐 주사 횟수의 영향 (Effect of the Number of Nozzle Scanning in Micro-Line Grooving of Glass by Powder Blasting)

  • 박경호;김광현;최종순;박동삼
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.294-299
    • /
    • 2001
  • The old technique of sandblasting which has been used for decoration of glass surface has recently been developed into a powder blasting technique for various materials, capable of producing micro structures larger than 100 m. This paper describes the performance of powder blasting technique in micro-line grooving of glass and the effect of the number of nozzle scanning on the depth and width of line groove. Experimental results showed that increasing the no. of nozzle scanning resulted in the increase of depth and width in grooves. Increase of width which may cause several problems in the precision machining results from wear of mask film.

  • PDF

Commissioning and Validation of a Dedicated Scanning Nozzle at Samsung Proton Therapy Center

  • Chung, Kwangzoo;Han, Younyih;Ahn, Sung Hwan;Kim, Jin Sung;Nonaka, Hideki
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.267-271
    • /
    • 2016
  • In this study, we present the commissioning and validation results of a dedicated scanning nozzle. The dedicated scanning nozzle is installed in one of the two gantry treatment rooms at Samsung Proton Therapy Center. Following a successful completion of the acceptance test, the commissioning process including the beam data measurement for treatment planning system has been conducted. Extended measurements have been conducted as a validation of the clinical performance of the nozzle and various quality assurance protocols have been prepared.

Powder Blasting을 이용한 미세 포켓가공 (Micromachining of Pocket by Powder Blasting)

  • 박경호;최종순;김광현;박동삼
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.1060-1063
    • /
    • 2001
  • The mechanical etching technique has recently been developed to a powder blasting technique for various materials, capable of producing micro structures larger than 100$\mu$m. This paper describes the performance of powder blasting technique in micro-pocketing of stainless steel and the effect of the number of nozzle scanning and the nozzle height on the depth and width of pockets. Experimental results showed that increasing the no. of nozzle scanning and decreasing the nozzle height resulted in the increase of depth and width in pockets. Increase of width results from wear of mask film.

  • PDF

Powder Blasting에 의한 미세 포켓의 기계적 에칭 (Mechanical Etching of Micro Pocket by Powder Blasting)

  • 박경호;오영탁;박동삼
    • 한국정밀공학회지
    • /
    • 제19권1호
    • /
    • pp.219-226
    • /
    • 2002
  • The mechanical etching technique has recently been developed to a powder blasting technique for various materials, capable of producing micro structures larger than 100$\mu$ m. This paper describes the performance of powder blasting technique in micro-pocketing of stainless steel and the effect of the number of nozzle scanning and the nozzle height on the depth and width of pockets. Experimental results showed that increasing the no. of nozzle scanning and decreasing the nozzle height resulted in the increase of depth and width in pockets. Increase of width results from wear of mask film.

Development of gamma ray scanning coupled with computed tomographic technique to inspect a broken pipe structure inside laboratory scale vessel

  • Saengchantr, Dhanaj;Srisatit, Somyot;Chankow, Nares
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.800-806
    • /
    • 2019
  • This paper presents a laboratory experiment on data acquisition technique that applied to the gamma radiation scanning coupled with computed tomography (CT) technique for inspection of broken nozzle inside the vertical vessel. The acquisition technique was developed to inspect a large diameter vessel when suspicious problem location is not easily accessed. This technique allows the installation of gamma radiation source (Cesium 137, Cs-137), and detectors (Sodium Iodine. NaI(Tl)) from the accessible location to the required location and performs the scanning by designed pattern. To demonstrate the designed technique, top opened tank which installed with six cut steel pipes diameter of 76.2 mm (3") at a certain position was selected. They were assumed to be a gas riser pipes inside the vessel. Three studied cases were performed, (a) projection of well installed six pipes, (b) projection of one out of six broken pipe and (c) one of nozzle was assumed to be failure and fell down until one out of six pipes was broken and obstructed by nozzle. Results clearly indicated the capability of developed technique to distinguish between normal situation case and abnormal situation cases.

Development of Electrospray Micro Thruster with Super-Hydrophobic PTFE Surface Nozzle Treated by Ar and Oxygen Ion Beam

  • Lee, Y.J.;Byun, D.Y.;Si, Bui Quang Tran;Kim, S.H.;Park, B.H.;Yu, M.J.;Kim, M.Y.
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.877-880
    • /
    • 2008
  • In this article, in order to fabricate polymer based electrospray device with super hydrophobic nozzle we use PTFE(polyfluorotetraethylene) plate and PMMA(polymethylmethacrylate). To obtain the super hydrophobic surface nozzle, PTFE surface is treated by argon and oxygen plasma treatment process. And evaluate the treated surface, perform measuring contact angle, SEM(Scanning Electron Microscope) and AFM(Atomic Force Microscope). We compare the performance of the super hydrophobic PTFE surface nozzle with raw PTFE and PMMA surface nozzle. For the ion beam treated PTFE nozzle, the liquid doesn't overflow and it keeps initial position and meniscus shape. From these results, we expect in cease of superhydrophobic surface nozzle jetting becomes more stable and repeatable.

  • PDF

초소수성 전기 분무 마이크로 추진 장치 및 마이크로 추력 측정 (Study on super-hydrophobic electro-spray micro thruster and measurement of micro scale thrust)

  • 이영종;유용훈;;김상훈;박배호;변도영
    • 한국항공우주학회지
    • /
    • 제37권2호
    • /
    • pp.175-180
    • /
    • 2009
  • 이 논문은 폴리머 기반의 전기 분무 장치를 만들기 위하여 이온빔 장치를 통하여 초소수성으로 가공 된 polytetrafluoroethylene(PTFE) 노즐을 사용하였다. 초소수성 표면을 만들기 위하여, PTFE 표면은 Ar과 $O_2$를 이용한 이온빔 공정 장치를 사용하였다. 최적의 표면 공정 조건은 Ar과 $O_2$ 유량 및 에너지 단위를 변화 시켜 얻을 수 있었다. 공정된 노즐의 표면 특성을 분석하기 위하여 접촉각 측정을 수행하였고, 표면의 형태적 분석을 위해 scanning electron microscope(SEM) 그리고 atomic force microscope(AFM) 측정을 하였다. 초소수성으로 공정된 노즐을 사용함으로써 보다 안정적이고 반복적인 전기 분무가 가능함을 확인 하였으며, 공정 된 노즐의 성능을 평가하기 위하여 외팔보와 이온빔으로 표면 처리 된 노즐 그리고 레이져 변위센서를 이용하여 마이크로 스케일의 추력을 측정하였다.

A Pilot Study of the Scanning Beam Quality Assurance Using Machine Log Files in Proton Beam Therapy

  • Chung, Kwangzoo
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.129-133
    • /
    • 2017
  • The machine log files recorded by a scanning control unit in proton beam therapy system have been studied to be used as a quality assurance method of scanning beam deliveries. The accuracy of the data in the log files have been evaluated with a standard calibration beam scan pattern. The proton beam scan pattern has been delivered on a gafchromic film located at the isocenter plane of the proton beam treatment nozzle and found to agree within ${\pm}1.0mm$. The machine data accumulated for the scanning beam proton therapy of five different cases have been analyzed using a statistical method to estimate any systematic error in the data. The high-precision scanning beam log files in line scanning proton therapy system have been validated to be used for off-line scanning beam monitoring and thus as a patient-specific quality assurance method. The use of the machine log files for patient-specific quality assurance would simplify the quality assurance procedure with accurate scanning beam data.

파우더 블라스팅을 이용한 Quartz Glass의 Lab-on-a-chip 성형 (Fabrication of lab-on-a-chip on quartz glass using powder blasting)

  • 장호수;박동삼
    • 한국기계가공학회지
    • /
    • 제8권4호
    • /
    • pp.14-19
    • /
    • 2009
  • Micro fluid channels are machined on quartz glass using powder blasting, and the machining characteristics of the channels are experimentally evaluated. The powder blasting process parameters such as injection pressure, abrasive particle size and density, stand-off distance, number of nozzle scanning, and shape/size of the required patterns affect machining results. In this study, the influence of the number of nozzle scanning, abrasive particle size, and blasting pressure on the formation of micro channels is investigated. Machined shapes and surface roughness are measured, and the results are discussed. Through the experiments and analysis, LOC are ettectinely machined on quartz glass using powder blasting.

  • PDF