• Title/Summary/Keyword: Nozzle scanning

Search Result 60, Processing Time 0.037 seconds

Effect of Nozzle Scanning in Micro Grooving of Glass by Powder Blasting (Powder Blasting 에 의한 유리의 미세 홈 가공시 노즐 주사횟수의 영향)

  • Kim, Kwang-Hyun;Choi, Jong-Sun;Park, Dong-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1280-1287
    • /
    • 2002
  • The old technique of sandblasting which has been used for decoration of glass surface has recently been developed into a powder blasting technique for brittle materials such as glass, silicon and ceramics, capable of producing micro structures larger than $100{\mu}$ m. This paper describes the performance of powder blasting technique in micro-line grooving of glass and the effect of the number of nozzle scanning on the depth and width of line groove. Experimental results showed that increasing the no. of nozzle scanning resulted in the increase of depth and width in grooves. Increase of width which may cause several problems in the precision machining results from wear of mask film. Therefore, well-controlled masking process is the most important factor for micro machining of glass with accuracy.

Effect of the Number of Nozzle Scanning in Micro-Line Grooving of Glass by Powder Blasting (Powder Blasting을 이용한 유리의 미세 선형 홈 가공시 노즐 주사 횟수의 영향)

  • 박경호;김광현;최종순;박동삼
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.294-299
    • /
    • 2001
  • The old technique of sandblasting which has been used for decoration of glass surface has recently been developed into a powder blasting technique for various materials, capable of producing micro structures larger than 100 m. This paper describes the performance of powder blasting technique in micro-line grooving of glass and the effect of the number of nozzle scanning on the depth and width of line groove. Experimental results showed that increasing the no. of nozzle scanning resulted in the increase of depth and width in grooves. Increase of width which may cause several problems in the precision machining results from wear of mask film.

  • PDF

Commissioning and Validation of a Dedicated Scanning Nozzle at Samsung Proton Therapy Center

  • Chung, Kwangzoo;Han, Younyih;Ahn, Sung Hwan;Kim, Jin Sung;Nonaka, Hideki
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.267-271
    • /
    • 2016
  • In this study, we present the commissioning and validation results of a dedicated scanning nozzle. The dedicated scanning nozzle is installed in one of the two gantry treatment rooms at Samsung Proton Therapy Center. Following a successful completion of the acceptance test, the commissioning process including the beam data measurement for treatment planning system has been conducted. Extended measurements have been conducted as a validation of the clinical performance of the nozzle and various quality assurance protocols have been prepared.

Micromachining of Pocket by Powder Blasting (Powder Blasting을 이용한 미세 포켓가공)

  • 박경호;최종순;김광현;박동삼
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.1060-1063
    • /
    • 2001
  • The mechanical etching technique has recently been developed to a powder blasting technique for various materials, capable of producing micro structures larger than 100$\mu$m. This paper describes the performance of powder blasting technique in micro-pocketing of stainless steel and the effect of the number of nozzle scanning and the nozzle height on the depth and width of pockets. Experimental results showed that increasing the no. of nozzle scanning and decreasing the nozzle height resulted in the increase of depth and width in pockets. Increase of width results from wear of mask film.

  • PDF

Mechanical Etching of Micro Pocket by Powder Blasting (Powder Blasting에 의한 미세 포켓의 기계적 에칭)

  • Park, Kyoung-Ho;Oh, Young-Tak;Park, Dong-Sam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.219-226
    • /
    • 2002
  • The mechanical etching technique has recently been developed to a powder blasting technique for various materials, capable of producing micro structures larger than 100$\mu$ m. This paper describes the performance of powder blasting technique in micro-pocketing of stainless steel and the effect of the number of nozzle scanning and the nozzle height on the depth and width of pockets. Experimental results showed that increasing the no. of nozzle scanning and decreasing the nozzle height resulted in the increase of depth and width in pockets. Increase of width results from wear of mask film.

Development of gamma ray scanning coupled with computed tomographic technique to inspect a broken pipe structure inside laboratory scale vessel

  • Saengchantr, Dhanaj;Srisatit, Somyot;Chankow, Nares
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.800-806
    • /
    • 2019
  • This paper presents a laboratory experiment on data acquisition technique that applied to the gamma radiation scanning coupled with computed tomography (CT) technique for inspection of broken nozzle inside the vertical vessel. The acquisition technique was developed to inspect a large diameter vessel when suspicious problem location is not easily accessed. This technique allows the installation of gamma radiation source (Cesium 137, Cs-137), and detectors (Sodium Iodine. NaI(Tl)) from the accessible location to the required location and performs the scanning by designed pattern. To demonstrate the designed technique, top opened tank which installed with six cut steel pipes diameter of 76.2 mm (3") at a certain position was selected. They were assumed to be a gas riser pipes inside the vessel. Three studied cases were performed, (a) projection of well installed six pipes, (b) projection of one out of six broken pipe and (c) one of nozzle was assumed to be failure and fell down until one out of six pipes was broken and obstructed by nozzle. Results clearly indicated the capability of developed technique to distinguish between normal situation case and abnormal situation cases.

Development of Electrospray Micro Thruster with Super-Hydrophobic PTFE Surface Nozzle Treated by Ar and Oxygen Ion Beam

  • Lee, Y.J.;Byun, D.Y.;Si, Bui Quang Tran;Kim, S.H.;Park, B.H.;Yu, M.J.;Kim, M.Y.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.877-880
    • /
    • 2008
  • In this article, in order to fabricate polymer based electrospray device with super hydrophobic nozzle we use PTFE(polyfluorotetraethylene) plate and PMMA(polymethylmethacrylate). To obtain the super hydrophobic surface nozzle, PTFE surface is treated by argon and oxygen plasma treatment process. And evaluate the treated surface, perform measuring contact angle, SEM(Scanning Electron Microscope) and AFM(Atomic Force Microscope). We compare the performance of the super hydrophobic PTFE surface nozzle with raw PTFE and PMMA surface nozzle. For the ion beam treated PTFE nozzle, the liquid doesn't overflow and it keeps initial position and meniscus shape. From these results, we expect in cease of superhydrophobic surface nozzle jetting becomes more stable and repeatable.

  • PDF

Study on super-hydrophobic electro-spray micro thruster and measurement of micro scale thrust (초소수성 전기 분무 마이크로 추진 장치 및 마이크로 추력 측정)

  • Lee, Young-Jong;Yoo, Yong-Hoon;Tran, Si Bui Quang;Kim, Sang-Hoon;Park, Bae-Ho;Buyn, Do-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.2
    • /
    • pp.175-180
    • /
    • 2009
  • In this article, we fabricated polytetrafluoroethylene(PTFE) nozzle treated by ion beam, in order to fabricate polymer based electrospray micro thruster with super hydrophobic nozzle. To obtain the super hydrophobic surface, PTFE surface is treated by argon and oxygen plasma treatment process. The optimal condition is investigated argon and oxygen flow rate as well as the paalied energy level for the treatment process. Fabricated nozzle was evaluated by measuring contact angle, and the surface morphology was examined by using scanning electron microscope(SEM) and atomic force microscope(AFM). We observe that jetting becomes more stable and repeatable on the treated nozzle. And to evaluate performance of fabricated nozzle, we measure micro scale thrust using a cantilever and a nozzle treated by ion beam laser displacement sensor.

A Pilot Study of the Scanning Beam Quality Assurance Using Machine Log Files in Proton Beam Therapy

  • Chung, Kwangzoo
    • Progress in Medical Physics
    • /
    • v.28 no.3
    • /
    • pp.129-133
    • /
    • 2017
  • The machine log files recorded by a scanning control unit in proton beam therapy system have been studied to be used as a quality assurance method of scanning beam deliveries. The accuracy of the data in the log files have been evaluated with a standard calibration beam scan pattern. The proton beam scan pattern has been delivered on a gafchromic film located at the isocenter plane of the proton beam treatment nozzle and found to agree within ${\pm}1.0mm$. The machine data accumulated for the scanning beam proton therapy of five different cases have been analyzed using a statistical method to estimate any systematic error in the data. The high-precision scanning beam log files in line scanning proton therapy system have been validated to be used for off-line scanning beam monitoring and thus as a patient-specific quality assurance method. The use of the machine log files for patient-specific quality assurance would simplify the quality assurance procedure with accurate scanning beam data.

Fabrication of lab-on-a-chip on quartz glass using powder blasting (파우더 블라스팅을 이용한 Quartz Glass의 Lab-on-a-chip 성형)

  • Jang, Ho-su;Park, Dong-sam
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.4
    • /
    • pp.14-19
    • /
    • 2009
  • Micro fluid channels are machined on quartz glass using powder blasting, and the machining characteristics of the channels are experimentally evaluated. The powder blasting process parameters such as injection pressure, abrasive particle size and density, stand-off distance, number of nozzle scanning, and shape/size of the required patterns affect machining results. In this study, the influence of the number of nozzle scanning, abrasive particle size, and blasting pressure on the formation of micro channels is investigated. Machined shapes and surface roughness are measured, and the results are discussed. Through the experiments and analysis, LOC are ettectinely machined on quartz glass using powder blasting.

  • PDF