The Effect of the Distance Between $CO_2$ Agent Nozzle and Wall ($CO_2$소화제 노즐과 벽간 거리의 영향)

  • Park Chan-Su
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.27-34
    • /
    • 2004
  • We have conducted a numerical simulation under three-dimensional unsteady conditions in order to analyze the effect of flow and CO₂ mass transfer according to the distance between the CO₂ nozzle of CO₂ fire fighting system and the rear wall in a protection space. Flow fields and CO₂ concentration fields were measured. The different recirculation flow form and wall jet was developed according to increasing the distance between CO₂ nozzles and rear wall. In all the case, CO₂ mass transfer was generated toward the center of a protection space from each walls, but the CO₂ mass fraction of front and rear areas based on CO₂ nozzles showed higher or lower by increasing the distance between CO₂ nozzle and rear wall.

Study on the Structures of the Nozzle for the Spray (분무기용(噴霧機用) Nozzle의 구조(構造)에 관한 연구(硏究))

  • Lee, S.W.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.2
    • /
    • pp.100-109
    • /
    • 1993
  • The aim of this study was to provide the reasonable data for design of the nozzle which produces finer droplets on the same level of the effective travel distance or which transports droplets to the farther target on the reasonable atomization in comparison with the commercial nozzles being used much in Korean rural areas. Newly designed twin-fluid atomizers with some commercial nozzles were tested in this study, and their results were as follows : 1. The characteristics of the spray deposit distribution of No.1 nozzles for farther target were nearly same in the near or nearer travel distance less than 8m. Therefore it was reasonable to combine the characteristics of the spray deposit distributions of No.2 and No.3 nozzles to those of No.1 nozzle. 2. The effective travel distance was increased with increase of the sectional area of the jet ligament, and the maximum effective travel distance was reached to about 17m. 3. The droplet size was increased with increase of the sectional area of the jet ligament, and the maximum droplet size was produced in the front of the point of the maximum spray deposit distribution. 4. The atomization was excellent in the twin-fluid atomizer in comparison with the hydraulic atomizer and also the effective travel distances were nearly same level in both atomizers.

  • PDF

An experimental study on the heat transfer and turbulent flow of round jet impinging the plate with temperature gradient (온도구배를 갖는 평판에 대한 원형 충돌제트의 열전달 및 난류유동에 관한 실험적 연구)

  • 한충호;이계복;이충구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.855-860
    • /
    • 1999
  • An experimental study of jet impingement on the surface with linear temperature gradient is conducted with the presentation of the turbulent characteristics and the heat transfer rates measured when this jet impinges normally to a flat plate. The jet Reynolds number ranges from 30,000 to 90,000, the temperature gradient of the plate is 2~$4.2^{\circ}C$/cm and the dimensionless nozzle to plate distance(H/D) is from 6 to 10. The results show that the peak of heat transfer rate occurs at the stagnation point, and the heat transfer rate decreases as the radial distance from the stagnation point increases. A remarkable feature of the heat transfer rate is the existence of the second peak. This is due to the turbulent development of the wall jet. Maximum heat transfer rate occurs when the axial distance from the nozzle to nozzle diameter(H/D) is 8. The heat transfer rate can be correlated as a power function of Prandtl number, Reynolds number and the dimensionless nozzle to plate distance(H/D). It has been found that the heat transfer rate increases with increasing turbulent intensity.

  • PDF

Effect of Water Impingement Conditions on the Degradation of Epoxy Coatings in Tap Water

  • Kim, D.H.;Yoo, Y.R.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.327-339
    • /
    • 2022
  • The water-jet technique started by Bridgman can cut metal and alloys without harmful gas and fume. However, while this technique is convenient to cut metals and alloys, in the case of coated pipe, water jet induces the degradation of coatings on the pipes, and may facilitate structural failure, leakage, and loss of products. While there are many reports on the effect of water jet on cut metals and the damage of metallic materials, research on the effect of water impingement on the epoxy coatings has been little studied. In this work, we therefore control the velocity of water jet, distance between nozzle and specimen, and water temperature, and discuss the effect of water impingement on the epoxy coatings. Increasing water velocity and water temperature and reducing nozzle distance increased the degradation rates of three epoxy coatings were increased. Among three test parameters - water velocity, nozzle distance and water temperature, water temperature was relatively effective to increase the degradation rate of epoxy coatings.

Enhancement of Impinging Jet Heat Transfer Using Triangular Multi-Tabs (삼각형 멀티 탭을 이용한 충돌제트 열전달 향상 연구)

  • Lee Jeong-Wook;Lee Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1139-1146
    • /
    • 2004
  • The effect of triangular tabs attached at the perimeter of jet nozzle on heat transfer enhancement was investigated experimentally. The modified flow structure was visualized using a smoke-wire method. Four different types of jet nozzle having 0, 4, 6 and 8 tabs were tested at jet Reynolds number Re=15,000 to investigate the effect of tabs on the variation of heat transfer rate. The local and average Nusselt numbers are increased with increasing the number of tabs. At nozzle-to-plate distance of L/D=4, the average Nusselt number was increased about 9.9% at Re=15,000 in the impingement region for the case of 8 tabs attachment. As the nozzle-to-plate distance increases, however, the heat transfer enhancement effect of triangular tabs is reduced. For the case of 4 tabs, the heat transfer enhancement is not so distinctive at L/D=8. As the protrusion depth of tabs into the jet flow increases, the heat transfer rate is also enhanced when the nozzle-to-plate distance is smaller than L/D=6.

A Study on the Wide Reach Nozzle of Sprayer (ll) (휴반용 분무기의 Nozzle에 관한 연구(II))

  • 원장우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.3
    • /
    • pp.3053-3058
    • /
    • 1973
  • 1. This study was conducted to examine the effects of change of the short range nozzle hole on the travelling distance. The results of this study are summarized as follows; a) Effect of change of the cap hole diameter on the travelling distance of sprayed particles was generally a linear, the increasing rate was about 0.27. b) When the difference between the sectional area of cap hole and that of grooves of swirl plate, was small the travelling distance was decreased by the decreasing of spraying speed at cap hole. 2. This study was conducted to examine the effects of change of the short range nozzle hole on the size of spraying particles. The results of this study are summarized as follows; a) The diameter of sprayed particles on travelling distances in the short range nozzle did not coincide with the kinetic energy principle derived from the momentum and the resistance. b) The average diameter of sprayed particle between 1m and 3m in which amount of sprayed particle was particularly a great deal, was big, because that some of sprayed particles were absorbed each other on the way to fall c) Effect of increase of cap hole diameter was generally enlarged the average diameter of sprayed particle with small rate.

  • PDF

A Study on Thermal Performance of an Impinging Cooling Module for High Power LEDs (고출력 LED에 적용한 분사냉각모듈의 열성능에 관한 연구)

  • Lee, Dong Myung;Park, Sang Hee;Kim, Dongjoo;Kim, Kyoungjin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.1
    • /
    • pp.13-19
    • /
    • 2012
  • Thermal performance of an impinging cooling module for 150 W class high power LEDs have been investigated numerically and experimentally. Parametric studies were performed to compare the effect of several design parameters such as nozzle number, nozzle spacing, coolant flow rate, and impinging distance. The experiments were also carried out in order to validate the numerical results and the comparison between the experimental and numerical results showed good agreement. It is found that the overall thermal resistance of impinging cooling module strongly depends on the nozzle number, nozzle spacing, flow rate, and impinging distance. This results showed the optimized operating condition when number of nozzles is 25, nozzles spacing is 4mm, flow rate is 2.70 lpm, distance between nozzles and impinging surface is 2 mm.

SPRAY AND COMBUSTION CHARACTERISTICS OF HYDROCARBON FUEL INJECTED FROM PRESSURE-SWIRL NOZZLES

  • Laryea Gabriel Nii;No Soo-Young
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.31-37
    • /
    • 2004
  • This paper presents spray and combustion characteristics of hydrocarbon fuel injected from pressure-swirl nozzles. Three commercial nozzles with orifice diameters of 0.256, 0.308 and 0.333mm and injection pressures ranging from 0.7 to 1.3 MPa were selected f9r the experiments. Spray characteristics such as breakup length. spray angle and drop size (SMD) were analyzed using photo image analyses and Malvern Panicle Size Analyzer. The drop size was measured with and without a blower at the same measuring locations. The flame length and width were measured using photo image analyses. The temperature distribution along the axial distance and the gas emission such as CO, $CO_2\;and\;NO_x$ were studied. The breakup length decreased with an increase in injection pressure for each nozzle but increased with an increase in nozzle orifice diameter. The spray angle increased and SMD decreased with an increase in injection pressure. The flame with an increased linearly with an increase in injection pressure and in nozzle orifice diameter. The flame temperature increased with an increase in injection pressure but decreased along the axial distance. The maximum temperatures occurred closer to the burner exit and flame at axial distance of 242mm from the diffuser tip. The experimental results showed that the level of CO decreased while that of $CO_2\;and\;NO_x$ increased with an increase in injection pressure and nozzle orifice diameter.

  • PDF

Study on the Improvement of Atomization of Droplet for Gun-type Nozzle (Gun-type Nozzle의 분무입자(噴霧粒子) 미립화(微粒化)에 관(關)한 연구(硏究))

  • Lee, Sang-Woo
    • Korean Journal of Agricultural Science
    • /
    • v.5 no.1
    • /
    • pp.29-34
    • /
    • 1978
  • In order to improve atomization of droplet of sprayers, gun-type nozzle equipped with swirl screw which could increase tangential velocity had been used in this study. The results obtained were as follow: The larger diameter of atomized droplet was, the longer it reached. Tile atomizing phenomenon while using swirl screw in the nozzle was more efficient. There was little difference of travelling distance in the both nozzles when the small diameter of disk hole was used, but thetravlling distance of the nozzle with swirl screw was evidently getting shorter with the increase of the hole diameter compared to that of the nozzle without swirl sorew. The size of sprayed particles was getting smaller owing to the phenomenon of air movement the one to two meters travelling distance of droplet from maximum travelling point.

  • PDF

Effect of Primary Nozzle Configuration on the Flow and Transfer Characteristics in an Ejector System for Pellet Transfer (펠릿 이송용 이젝터의 구동노즐 구성에 따른 유동 및 이송특성에 관한 실험적 연구)

  • Kim, Keum-Kyu;Kim, Eui-Soo;Kang, Shin-Myoung;Lee, Jee-Keun;Rho, Byung-Joon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.49-59
    • /
    • 2008
  • The effects of design parameters on the pellet transport rate in the ejector system which is widely used in the production processes of automotive parts were investigated experimentally. The primary nozzle geometry, the area ratio (R) of nozzle exit cross-sectional area to mixing chamber cross-sectional area and the distance (S) from primary nozzle exit to mixing chamber entrance were considered as the design parameters. The area ratios of the primary nozzle were varied from R=0.10 to R=0.25, 0.30, 0.40 and 0.55. The primary nozzle was positioned at the non-dimensional distance (S/D) of 1.30, 1.87, 2.44, 3.00 and 3.75, normalized using the mixing chamber diameter (D). The design parameters were determined to run with high efficiency by measuring the pellets transport rate. The geometry and the area ratio (R) of the primary nozzle had an effect on the pellet transport rate of the ejector system, and the area ratio of R=0.3 was carefully selected after taking the minimum fluidization velocity and transport rate of applied pellets into account. The higher pellet transport rate with the variation of the distance (S/D) was observed at S/D of 2.44.