• 제목/요약/키워드: Nose

검색결과 1,633건 처리시간 0.025초

鼻病의 外治法에 關한 文獻的 考察 (A Literature study on the external treatment of nose diseases)

  • 박상균;노석선
    • 한방안이비인후피부과학회지
    • /
    • 제10권1호
    • /
    • pp.139-158
    • /
    • 1997
  • A Literature study on the external treatment of nose diseases, the results are as follows; 1. Nose was called "Cheun-bin(天牝)", was outer orifice of the lung, was the gate of vital energe(氣), The main function of nose is divided three pacts. One is the respiration, another is the sense of smell, the other is the sounding consonance. 2. Nose is concerned with The Lung(肺), The Spleen(脾), The Heart(心), The Stomach(胃), The Large intestine(大腸), The Bladder(膀胱) in the organs, is concerned with Lung Meridean, Large intestine Meridean, Stomach Meridean, Heart Meridean, Spleen Meridean, Governor Vessel Meridean etc. 3. The method on the external treatment of nose diseases is classified with obstructive method, pouring method, blowing method, attaching method, plaster method, rubbing method, cleansing method, poulticing method. In frequency of practical use, Obstructive method is used 276 cases, Blowing method is used 123 cases, Attaching method is used 103 cases, Plaster method is used 76 cases. 4. In frequency of the medicinal works on the external treatment of nose diseases, Herba Asari(細辛) is used 134 cases, Pedicellus Melo(瓜 ) is used 85 cases, Radix Aconiti Praeparata(附子) is used 52 cases, Herba Agastachis(麝香) is used 51 cases, Semen Armeniacae Amarurn(杏仁) is used 44 cases etc. In frequency of a prescription on the external treatment of nose diseases, Tongcho-san(通草散) is used 9 cases, $Sesin-go{\cdot}Sinyi-go{\cdot}Changpo-san$ are used 8 cases, $Kwache-san{\cdot}Wungwhang-san$ are used 7 cases etc.

  • PDF

일측 구순열비변형에서 음향비계측법(acoustic rhinometry)의 이용: 개열측과 비개열측의 비교 (Acoustic Rhinometric Comparison of Cleft Side with Non-cleft Side after Repair of Unilateral Cleft Lip Nose Deformity)

  • 한기환;권혁준;김현지;김준형;손대구
    • Archives of Plastic Surgery
    • /
    • 제33권1호
    • /
    • pp.75-79
    • /
    • 2006
  • The upper and lower lateral cartilages provide the key to the lower cartilaginous portion of the nose. Lifting the cartilages is essential procedure for correction of unilateral cleft lip nose deformity. After correction of cleft lip nose deformity, authors used acoustic rhinometry (AR) to compare the lower nasal cavity of cleft side with non-cleft side. AR is a well known new, non-invasive diagnostic technique in which nasal geometry is assessed by means of acoustic reflection. From June 1996 to January 2004, we performed acoustic rhinometric analysis after correction of unilateral cleft lip nose deformity. This study involved 40 children of age ranged from 3 months to 8 years. Subjects were divided into the group of incomplete unilateral cleft lip nose deformity(20 subjects), and the group of complete unilateral cleft lip nose deformity(20 subjects). Results show that lower nasal cavity volume between non-cleft side and cleft side has no difference, and better results were obtained when nasal molding prong was applied at cleft side nostril. The results between incomplete type and complete type have no significant difference. In conclusion, AR is an effective method to calibrate cross sectional area and nasal cavity volume of unilateral cleft lip nose deformity, and furthermore effective in comparing the volume of cleft side with non-cleft side after unilateral cleft lip nose deformity correction with lifting the lower lateral cartilages to the upper lateral cartilages.

Nasal airway function after Le Fort I osteotomy with maxillary impaction: A prospective study using the Nasal Obstruction Symptom Evaluation scale

  • Kim, Hyo Seong;Son, Ji Hwan;Chung, Jee Hyeok;Kim, Kyung Sik;Choi, Joon;Yang, Jeong Yeol
    • Archives of Plastic Surgery
    • /
    • 제48권1호
    • /
    • pp.61-68
    • /
    • 2021
  • Background This study evaluated changes in nasal airway function following Le Fort I osteotomy with maxillary impaction according to the Nasal Obstruction Symptom Evaluation (NOSE) scale. Methods This cohort study included 13 patients who underwent Le Fort I osteotomy with maxillary impaction. Nasal airway function was evaluated based on the NOSE scale preoperatively and at 3 months postoperatively. The change in the NOSE score was calculated as the preoperative score minus the postoperative score. If the normality assumptions for changes in the NOSE score were not met, a nonparametric test (the Wilcoxon signed-rank test) was used. Differences in NOSE score changes according to patient characteristics and surgical factors were evaluated using the Kruskal-Wallis test and the Mann-Whitney test. Results Patients ranged in age from 18 to 29 years (mean ±standard deviation [SD], 23.00±3.87 years). Three were men and 10 were women. Eleven patients (84%) had an acquired dentofacial deformity with skeletal class III malocclusion. The preoperative NOSE scores ranged from 40 to 90 (mean±SD, 68.92±16.68), and the postoperative NOSE scores ranged from 25 to 80 (53.84±18.83). The cohort as a whole showed significant improvement in nasal airway function following maxillary impaction (P=0.028). Eleven patients (84%) had either improved (n=8) or unchanged (n=3) postoperative NOSE scores. However, nasal airway function deteriorated in two patients. Patient characteristics and surgical factors were not correlated with preoperative or postoperative NOSE scores. Conclusions Nasal airway function as evaluated using the NOSE scale improved after maxillary impaction.

Miniaturized Electronic Nose System Based on a Personal Digital Assistant

  • Kim, Yong-Shin;Yang, Yoon-Seok;Ha, Seung-Chul;Pyo, Hyeon-Bong;Choi, Auck-Choi
    • ETRI Journal
    • /
    • 제27권5호
    • /
    • pp.585-594
    • /
    • 2005
  • A small electronic nose (E-Nose) system has been developed using an 8-channel vapor detection array and personal digital assistant (PDA). The sensor array chip, integrated on a single microheater-embedded polyimide substrate, was made of carbon black-polymer composites with different kinds of polymers and plasticizers. We have successfully classified various volatile organic compounds such as methanol, ethanol, i-propanol, benzene, toluene, n-hexane, n-heptane, and c-hexane with the aid of the sensor array chip, and have evaluated the resolution factors among them, quantitatively. To achieve a PDA-based E-Nose system, we have also elaborated small sensor-interrogating circuits, simple vapor delivery components, and data acquisition and processing programs. As preliminary results show, the miniaturized E-Nose system has demonstrated the identification of essential oils extracted from mint, lavender, and eucalyptus plants.

  • PDF

변단면 압출 추진코와 ILM교량 상부구조와의 상호작용 (Nose-Deck Interaction in ILM Bridge Proceeding with Tapered Sectional Launching Nose)

  • 안태욱;김광양;이환우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.455-462
    • /
    • 2004
  • The ILM(incremental launching method) bridge, which is one of PS(prestressed) concrete bridge construction methods is widely adopted in Korea owing to its effectiveness for the quality control in construction. The purpose of this study is to analyze the structural behavior of ILM bridge proceeding with tapered sectional launching nose. This study presents basic technical materials to achieve the optimum design for superstructure and launching nose of ILM bridge. First this study introduces an equation to analyze the interaction between launching nose and superstructure. In this process, relative length, weight, and flexural stiffness between launching nose and superstructure are considered as investigating parameters. Second, the effects of superstructure resulting from these parameters is estimated analyzed by using the induced equations.

  • PDF

전자코 시스템을 이용한 우유의 품질에 따른 휘발성 향기성분 분석 (Analysis of Volatile Flavor Compounds in Milk Using Electronic Nose System)

  • 강내경;전태선;양윤석;김용신
    • 센서학회지
    • /
    • 제23권5호
    • /
    • pp.320-325
    • /
    • 2014
  • Volatile flavor compounds from milk were analyzed and identified by using the analysis methods of headspace solid phase microextraction gas chromatography/mass spectrometry (HSPME-GC/MS) and electronic nose (E-Nose) system. About 30 volatile compounds were identified by HSPME-GC/MS for the fresh and off-flavor milk samples. Also, the correlation between rancidity and ageing days of milk was obtained by the aid of principal component analysis algorithm. It shows that the E-Nose system can identify the various types of milk flavor. These results imply that the analysis method based on the E-nose system can apply to the quality control of milk flavor and the rancidity.

통계적 기법을 이용한 선삭 가공 절삭조건에 따른 공구온도 예측 (Study on the tool temperature estimation for different cutting conditions in turning using a statistical method)

  • 김성청;이응석;문홍현;송길용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.851-856
    • /
    • 1997
  • This study is on the estimation of the tool temperature for different tool nose radius and cutting conditions in turning. The experiment has been performed in different cutting conditions such as cutting speed, feed rate, and depth of cut for the tool nose radius, 0.4R, 0.8R using SMC workpiece materials. Tool temperature is measured using thermo-couple which is embedded in the insert tip. Using a multiple linear regression method, the tool temperature can be determined as an exponential equation with cutting variables and tool nose diameters for different tool materials. The equations determined in this study show a good correlation for the cutting conditions and can be used for the tool temperature estimation. The result indicates that the tool temperature decreases for ~ncreasing the tool nose radius in general. Also, nose radius hardly influences on the tool temperature compared with cutting speed, feed rate and depth of cut.

  • PDF

PDA를 이용한 휴대용 Electronic Nose 시스템 개발 (Design of a Potable Electronic Nose System using PDA)

  • 김정도;변형기;함유경
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.454-461
    • /
    • 2004
  • We have designed a portable electronic nose (e-nose) system using an array of commercial gas sensors and personal digital assistants (PDA) for the recognition and analysis of volatile organic compounds (VOC) in the field. Field screening of pollutants has been a target of instrumental development during the past years. A portable e-nose system was advantageous to localize the special extent of a pollution or to find pollutants source. The employment of PDA improved the user-interface and data transfer by Internet from on-site to remote computer. We adapted the Lavenberg-Marquardt algorithm based on the back-propagation and proposed the method that could predict the concentration levels of VOC gases after classification by separating neural network into two parts.

형상함수를 이용한 열차 전두부 설계기법 연구 (Study on the Design Method for the Train Nose Shape Using the Configuration Function)

  • 구요천;노주현;윤수환;곽민호;이동호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2218-2223
    • /
    • 2008
  • A nose shape is strongly related with the aerodynamic performances of train. Therefore shape definition and aerodynamic performance analysis are important for train nose shape design. In this study, a new design method was suggested for train nose shape design by configuration function. To this end, the nose shape was classified by box type and each box shape is defined. After that the 3-D shape of train was defined as several mathematical functions by combination of each box shape. Also it was shown that the wind shield of driver's seat and complex curves of surface can be expressed using superposition of functions. This methodology can be used for grid generation of numerical analysis, and applied to aerodynamic optimization design of nose shape.

  • PDF

전자코를 이용한 휘발성분의 분석과 식품에의 이용 (Analysis of Volatile Compounds using Electronic Nose and its Application in Food Industry)

  • 노봉수
    • 한국식품과학회지
    • /
    • 제37권6호
    • /
    • pp.1048-1064
    • /
    • 2005
  • Detection of specific compounds influencing food flavor quality is not easy. Electronic nose, comprised of electronic chemical sensors with partial specificity and appropriate pattern recognition system, is capable of recognizing simple and complex volatiles. It provides fast analysis with simple and straightforward results and is best suited for quality control and process monitoring of flavor in food industry. This review examines application of electronic nose in food analysis with brief explanation of its principle. Characteristics of different sensors and sensor drift. and solutions to related problems are reviewed. Applications of electronic nose in food industry include monitoring of fermentation process and lipid oxidation, prediction of shelf life, identification of irradiated volatile compounds, discrimination of food material origin, and quality control of food and processing by principal component analysis and neural network analysis. Electronic nose could be useful for quality control in food industry when correlating analytical instrumental data with sensory evaluation results.