• Title/Summary/Keyword: Normalized energy demand

Search Result 14, Processing Time 0.031 seconds

Evaluation of Liquefiable Soils by Energy Concept (에너지 개념에 기초한 액상화 평가방법에 관한 연구)

  • Kim, Soo-Il;Sun, Yu-Jung;Park, Keun-Bo;Park, Seong-Yong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.590-599
    • /
    • 2006
  • In this study, Liquefaction characteristics of saturated sand under various dynamic loadings such as sinusoidal loading, increasing wedge loading, and real earthquake loading were investigated focusing on the dissipated energy. From the results of cyclic triaxial test, liquefaction resistance strength was calculated by the concept of energy according to the type of input loading. Liquefaction resistance strength was expressed in accumulated dissipated energy calculated from stress-strain curve(hysteresis loop). The dissipated energy according to loading type was compared and the energy-based evaluation was proposed. The procedures are presented in terms of normalized energy demand(NED), normalized energy capacity(NEC), and factor of safely, where NED is the load imparted to the soil by the loading(both amplitude and duration), NEC is the demand required to induce liquefaction, and factor of safely is defined as the ratio of NEC and NED.

  • PDF

A simplified normalized cumulative hysteretic energy spectrum

  • Sun, Guohua;Gu, Qiang;Fang, Youzhen
    • Earthquakes and Structures
    • /
    • v.12 no.2
    • /
    • pp.177-189
    • /
    • 2017
  • For energy-based seismic design, a simplified normalized cumulative hysteretic energy spectrum proposed for obtaining hysteretic energy as energy demand is the main objective in this paper. The dimensionless parameter, ${\beta}_{Eh}$, is presented to express hysteretic energy indirectly. The ${\beta}_{Eh}$ spectrum is constructed directly through subtracting the hysteretic energy of single degree-of-freedom (SDOF) system energy equation. The simplified ${\beta}_{Eh}$ spectral formulation as well as pseudo-acceleration spectrum of modern seismic provisions is developed based on the regression analysis of the large number of seismic responses of SDOF system subjected to earthquake excitations, which considers the influence of earthquake event, soil type, damping ratio, and ductility factor. The relationship between PGV and PGA is established according to the statistical analysis relied on a total of 422 ground motion records. The combination of ${\beta}_{Eh}$ spectrum and PGV/PGA equation allows determining the cumulative hysteretic energy as a main aseismic design indicator.

Energy dissipation demand of compression members in concentrically braced frames

  • Lee, Kangmin;Bruneau, Michel
    • Steel and Composite Structures
    • /
    • v.5 no.5
    • /
    • pp.345-358
    • /
    • 2005
  • The response of single story buildings and other case studies are investigated to observe trends in response and to develop a better understanding of the impact of some design parameters on the seismic response of CBF. While it is recognized that many parameters have an influence on the behavior of braced frames, the focus of this study is mostly on quantifying energy dissipation in compression and its effectiveness on seismic performance. Based on dynamic analyses of single story braced frame and case studies, it is found that a bracing member designed with bigger R and larger KL/r results in lower normalized cumulative energy, i.e., cumulative compressive energy normalized by the corresponding tensile energy (${\sum}E_C/E_T$), in both cases.

Sensitivity Analysis of Temperature on Special Day Electricity Demand in Jeju Island (제주도의 특수일 전력수요에 대한 기온 민감도 분석)

  • Jo, Se-Won;Park, Rae-Jun;Kim, Kyeong-Hwan;Kwon, Bo-Sung;Song, Kyung-Bin;Park, Jeong-Do;Park, Hae-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1019-1023
    • /
    • 2018
  • In this paper sensitivity analysis of temperature on special day electricity demand of land and Jeju Island is performed. The basic electricity demand per 3 hours is defined as electricity demand that reflects the GDP effect without the temperature influence. The temperature sensitivity per 3 hours is calculated through the relationship between special day electricity demand normalized to basic electricity demand and temperature. In the future, forecast error will be improved if the temperature sensitivity per 3 hours is applied to the special day load forecasting.

Seismic Energy Absorption Capacity in R.C. Structures (R.C. 구조물의 지진에너지 흡수능력 연구)

  • 김장훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.217-224
    • /
    • 1997
  • One way in which a comparison can be mode between various reinforced concrete structures is to compare the rate of energy absorption capacity. It is useful to use a well-known standard hysteretic rule as a benchmark for comparisons. The concept of energy absorption efficiency with respect to an elaste-perfectly plastic (EPP) system has been adopted. The normalized cumulative energy, cumulative plastic drift and energy response spectra are used for the method. The previous study using the energy spectra developed by Chang and Mander (1994) indicates the cumulative plastic demand for most earthquakes to be 0.1 rad., but a conservative upper bound of 0.2 rad. could be expected for a maximum credible earthquake. From the present study, the energy absorption efficiency in R.C. structures with respect to the EPP system may range in 30%-45% for most cases.

  • PDF

NEW EVALUATION METHODS FOR RADIAL UNIFORMITY IN NEUTRON TRANSMUTATION DOPING

  • Kim, Hak-Sung;Lim, Jae-Yong;Pyeon, Cheol-Ho;Misawa, Tsuyoshi;Shiroya, Seiji;Park, Sang-Jun;Kim, Myong-Seop;Oh, Soo-Youl;Jun, Byung-Jin
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.442-449
    • /
    • 2010
  • Recently, the neutron irradiation for large diameter silicon (Si)-ingots of more than 8" diameter is requested to satisfy the demand for the neutron transmutation doping silicon (NTD-Si). By increasing the Si-ingot diameter, the radial non-uniformity becomes larger due to the neutron attenuation effect, which results in a limit of the feasible diameter of the Si-ingot. The current evaluation method has a certain limit to precisely evaluate the radial uniformity of Si-ingot because the current evaluation method does not consider the effect of the Si-ingot diameter on the radial uniformity. The objective of this study is to propose a new evaluation method of radial uniformity by improving the conventional evaluation approach. To precisely predict the radial uniformity of a Si-ingot with large diameter, numerical verification is conducted through comparison with the measured data and introducing the new evaluation method. A new concept of a gradient is introduced as an alternative approach of radial uniformity evaluation instead of the radial resistivity gradient (RRG) interpretation. Using the new concept of gradient, the normalized reaction rate gradient (NRG) and the surface normalized reaction rate gradient (SNRG) are described. By introducing NRG, the radial uniformity can be evaluated with one certain standard regardless of the ingot diameter and irradiation condition. Furthermore, by introducing SNRG, the uniformity on the Si-ingot surface, which is ignored by RRG and NRG, can be evaluated successfully. Finally, the radial uniformity flattening methods are installed by the stainless steel thermal neutron filter and additional Si-pipe to reduce SNRG.

Prediction of Power Consumptions Based on Gated Recurrent Unit for Internet of Energy (에너지 인터넷을 위한 GRU기반 전력사용량 예측)

  • Lee, Dong-gu;Sun, Young-Ghyu;Sim, Is-sac;Hwang, Yu-Min;Kim, Sooh-wan;Kim, Jin-Young
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.120-126
    • /
    • 2019
  • Recently, accurate prediction of power consumption based on machine learning techniques in Internet of Energy (IoE) has been actively studied using the large amount of electricity data acquired from advanced metering infrastructure (AMI). In this paper, we propose a deep learning model based on Gated Recurrent Unit (GRU) as an artificial intelligence (AI) network that can effectively perform pattern recognition of time series data such as the power consumption, and analyze performance of the prediction based on real household power usage data. In the performance analysis, performance comparison between the proposed GRU-based learning model and the conventional learning model of Long Short Term Memory (LSTM) is described. In the simulation results, mean squared error (MSE), mean absolute error (MAE), forecast skill score, normalized root mean square error (RMSE), and normalized mean bias error (NMBE) are used as performance evaluation indexes, and we confirm that the performance of the prediction of the proposed GRU-based learning model is greatly improved.

Performance and Internal Flow of a Cross-Flow Type Hydro Turbine for Wave Power Generation (파력발전용 횡류형 수력터빈의 성능 및 내부유동)

  • Choi, Young-Do;Cho, Young-Jin;Kim, You-Taek;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.3
    • /
    • pp.22-29
    • /
    • 2008
  • Clean and renewable energy technologies using ocean energy give us non-polluting alternatives to fossil and nuclear-fueled power plants to meet establishment of countermeasures against the global warming and growing demand for electrical energy. Among the ocean energy resources, wave power takes a growing interest because of its enormous amount of potential energy in the world. Therefore, various types of wave power conversion system to capture the energy of ocean waves have been developed. However, suitable turbine type is not normalized yet because of relatively low efficiency of the turbine systems. The purpose of this study is to investigate the internal flow and performance characteristics of a cross-flow type hydro turbine, which will be built in a caisson for wave power generation. Numerical simulation using a commercial CFD code is conducted to clarify the effects of the turbine rotation speed and flow rate variation on the turbine characteristics. The results show that the output power of the cross-flow type hydro turbine with symmetric nozzle shape is obtained mainly from Stage 2. Turbine inlet configuration should be designed to obtain large amount of flow rate because the static pressure and absolute tangential velocity are influenced considerably by inlet flow rate.

New optimum distribution of lateral strength of shear-type buildings for uniform damage

  • Donaire-Avila, Jesus;Lucchini, Andrea;Benavent-Climent, Amadeo;Mollaioli, Fabrizio
    • Structural Engineering and Mechanics
    • /
    • v.76 no.3
    • /
    • pp.279-291
    • /
    • 2020
  • The seismic design of conventional frame structures is meant to enhance plastic deformations at beam ends and prevent yielding in columns. To this end, columns are made stronger than beams. Yet yielding in columns cannot be avoided with the column-to-beam strength ratios (about 1.3) prescribed by seismic codes. Preventing plastic deformations in columns calls for ratios close to 4, which is not feasible for economic reasons. Furthermore, material properties and the rearrangement of geometric shapes inevitably make the distribution of damage among stories uneven. Damage in the i-th story can be characterized as the accumulated plastic strain energy (Wpi) normalized by the product of the story shear force (Qyi) and drift (δyi) at yielding. Past studies showed that the distribution of the plastic strain energy dissipation demand, Wpi/ΣWpj, can be evaluated from the deviation of Qyi with respect to an "optimum value" that would make the ratio Wpi/(Qyiδyi) -i.e. the damage- equal in all stories. This paper investigates how the soil type and ductility demand affect the optimum lateral strength distribution. New optimum lateral strength distributions are put forth and compared with others proposed in the literature.

Demands and distribution of hysteretic energy in moment resistant self-centering steel frames

  • Lopez-Barraza, Arturo;Ruiz, Sonia E.;Reyes-Salazar, Alfredo;Bojorquez, Eden
    • Steel and Composite Structures
    • /
    • v.20 no.5
    • /
    • pp.1155-1171
    • /
    • 2016
  • Post-tensioned (PT) steel moment resisting frames (MRFs) with semi-rigid connections (SRC) can be used to control the hysteretic energy demands and to reduce the maximum inter-story drift (${\gamma}$). In this study the seismic behavior of steel MRFs with PT connections is estimated by incremental nonlinear dynamic analysis in terms of dissipated hysteretic energy ($E_H$) demands. For this aim, five PT steel MRFs are subjected to 30 long duration earthquake ground motions recorded on soft soil sites. To assess the energy dissipated in the frames with PT connections, a new expression is proposed for the hysteretic behavior of semi-rigid connections validated by experimental tests. The performance was estimated not only for the global $E_H$ demands in the steel frames; but also for, the distribution and demands of hysteretic energy in beams, columns and connections considering several levels of deformation. The results show that $E_H$ varies with ${\gamma}$, and that most of $E_H$ is dissipated by the connections. It is observed in all the cases a log-normal distribution of $E_H$ through the building height. The largest demand of $E_H$ occurs between 0.25 and 0.5 of the height. Finally, an equation is proposed to calculate the distribution of $E_H$ in terms of the normalized height of the stories (h/H) and the inter-story drift.