• 제목/요약/키워드: Normalized Sound Pressure Level

검색결과 8건 처리시간 0.021초

임펄스응답적분법을 이용한 잔향시간의 측정방법이 규준화 바닥충격음레벨에 미치는 영향 (Effect of the Measuring Method of Reverberation Time Using Impulse Response Method on the Normalized Impact Sound Pressure Level)

  • 이주원;권영필
    • 한국소음진동공학회논문집
    • /
    • 제16권1호
    • /
    • pp.34-39
    • /
    • 2006
  • For the evaluation of the normalized impact sound pressure level, the reverberation time of the receiving room should be measured. This paper deals with the effect of the time constant of FFT analyzer and the measuring points on reverberation time. It is found that the time constant should be in the range between 10 ms and 35 ms. While the effect of measuring points on the reverberation time is significant when the bandwidth is narrow it is negligible in the evaluation of the normalized impact sound pressure level.

수음실 잔향시간 변화에 따른 중량 충격음 레벨 특성 - 실험실 환경을 중심으로 - (Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in Mock-up Test Rooms)

  • 정정호;이병권;연준오;전진용
    • 한국소음진동공학회논문집
    • /
    • 제24권4호
    • /
    • pp.339-347
    • /
    • 2014
  • Floor impact sound in high-rise apartment building became one of social problems. A lot of civil complaints on floor impact sound occur continuously and the number of disputes between neighbors in small and aged apartment buildings is increasing. Interests on heavy-weight impact sound pressure level measurement and evaluation method is increased. Previous study reported that heavy-weight impact sound level was changed by the sound field condition of receiving reverberation chamber. In this study, heavy-weight impact sound pressure level change by the receiving sound field condition was measured in standard test facility and mock-up test room. These two experimental conditions were designed to simulate averaged living room of common apartment units. By the change of sound absorption power in receiving room, heavy-weight impact sound pressure level in most of frequency bands were changed in standard test facility and mock-up room. Normalized maximum sound pressure level regulated in ISO 16032 showed wider range of heavy/soft impact sound pressure level. Heavy/soft impact sound pressure level change was became smaller by the application of standardized maximum sound pressure level and ISO/CD 10140-3 Amd 2 method. In the case of standardized maximum sound pressure level, absolute sound pressure level changed. From these results, receiving sound field correction method regulated in ISO/CD 10140-3 Amd 2 is needed for the precision measurement and evaluation of heavy-weight impact sound.

경량충격음 평가시 잔향시간 영향에 대한 고려 (Analysis of the Reverberation Time in the Normalized Impact Sound Pressure Level)

  • 박철용;홍구표;김상훈;장동운
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.952-955
    • /
    • 2007
  • 경량충격음레벨을 평가하기 위해서는 수음실의 잔향시간을 측정하여 규준화 바닥충격음레벨을 구하여야 한다. 본 논문에서는 규준화 바닥충격음레벨과 표준화 바닥충격음레벨을 구할 때 고려하는 보정레벨을 중심으로 등가 흡음력을 결정하는 잔향시간과 수음실의 체적을 변수요인으로 분석하였다. 그 결과 측정된 잔향 시간은 공간에 관계없이 기준보다 2배 이상 길게 나타났고, 등가 흡음력은 기준보다 침실의 경우 1/2 정도 작지만 거실의 경우 기준과 거의 유사하게 나타나 침실의 경우 두 보정레벨이 유사하지만 거실의 경우 전자가 후자보다 낮게 보정되는 것으로 나타났다.

  • PDF

Evaluation of Impact Sound Insulation Properties of Light-Framed Floor with Radiant Floor Heating System

  • Nam, Jin-Woo;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권3호
    • /
    • pp.75-84
    • /
    • 2002
  • In order to find out impact insulation properties, various types of current radiant floor heating systems and light-framed floors that are used in light-framed residential buildings were evaluated for two types of impact sources at the same time. Sound Pressure Level (SPL) was different from each impact sources for those spectrum patterns and peaks. In case of light-framed floor framework, the excitation position and the assumed effective vibrating area have effects on sound pressure level but it is not considerable, and Normalized SPL was reduced for each frequency by increasing the bending rigidity of joist. The mortar layer in the radiant heating system had relatively high density and high impedance, therefore, it distributed much of the impact power when it was excited, and reduced the Normalized SPL considerably. Nevertheless, Increasing a thickness of mortar layer had little influence on SPL. Ceiling components reduced the sound pressure level about 5~25 dB for each frequency. Namely, it had excellent sound insulation properties in a range from 200 to 4,000 Hz frequency for both heavy and lightweight impact sources. Also, there was a somewhat regular sound insulation pattern for each center frequency. The resilient channel reduced the SPL about 2~11 dB, irrelevant to impact source. Consequently, current radiant floor heating systems which were established in light-framed residential buildings have quite good impact sound insulation properties for both impact sources.

규준화 바닥충격음레벨 측정시 잔향시간의 편차요인 분석 (Analysis of the Deviation Factor in a Reverberation Time to Measuring the Normalized Impact Sound Pressure Level)

  • 이주원;홍병국;이동훈;권영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.509-512
    • /
    • 2004
  • 규준화 바닥충격음레벨 평가시 잔향시간은 흡음력 보정을 위해서 필수적으로 고려해야 할 사항이다. 그러나, 잔향시간의 측정 편차가 심하기 때문에 이로 인해 규준화 바닥충격음레벨이 5dB 이상씩 변동하는 경우가 생긴다. 잔향시간 측정 편차의 원인은 실의 형상에 따른 고유모드 분포로 설명할 수 있으며, 측정시 계측기에서의 원인, 특히 동특성에 따라 측정 편차가 심하다는 것을 실험을 통해 알 수 있었다. 또한, 잔향곡선은 직선적인 형태일 경우에 정확한 측정이 가능하나, 저주파수 대역에서는 잔향곡선에 요철이 많이 생기므로 측정 데이터들을 이용하여 잔향시간을 산출할 때 세심한 주의가 요구된다.

  • PDF

철도차량 차체용 더블 스킨 알루미늄 압출 패널의 감쇠특성 (Damping Characterization of the Double-skin Aluminum Extruded Panels for Rolling Stock Carbody)

  • 강길현;김철수
    • 한국산학기술학회논문지
    • /
    • 제14권7호
    • /
    • pp.3197-3202
    • /
    • 2013
  • 철도차량 차체 설계시 음압레벨에 따른 소음해석을 통한 차체 패널의 감쇠특성을 최적화하는 것이 필요하다. 본 논문은 철도차량 차체용 알루미늄 더블스킨 압출패널의 진동감쇠특성 해석을 통한 철도차량 차체의 구조소음 해석에 관한 연구이다. 주파수응답 가진시험을 통하여 측정된 기계적 모빌리티 값인 포인트 모빌리티, 트랜스퍼 모빌리티, 모달 모빌리티와 단순음원이론을 사용하여 정규화된 음압을 계산하였다. 도포용 감쇠재의 감쇠값을 라미네이티드 쉘요소에 사용하여 유한요소해석을 수행함으로써, 감쇠처리에 의한 소음감소수준 예측을 하였다. 또한 실제 차량 구조와 유사한 고정경계조건의 감쇠특성해석을 통하여 열차주행시 발생하는 진동의 영향을 크게 받는 언더프레임과 같은 부위에 일정 두께의 감쇠재 코팅이 진동 및 소음억제에 큰 효과가 있을 것으로 사료된다.

음향 부양장(acoustic levitation field)에서 초음파 주파수(ultrasonic frequency)에 따른 단일 액적의 미립화 특성 (Effect of Ultrasonic Frequency on the Atomization Characteristics of Single Water Droplet in an Acoustic Levitation Field)

  • 서현규
    • 한국분무공학회지
    • /
    • 제18권3호
    • /
    • pp.126-131
    • /
    • 2013
  • This paper describes the effect of ultrasonic frequency(f) on the atomization and deformation characteristics of single water droplet in an acoustic levitation field. To achieve this, the ultrasonic levitator that can control sound pressure and velocity amplitude by changing frequency was installed, and visualization of single water droplet was conducted with high resolution ICCD and CCD camera. At the same time, atomization and deformation characteristics of single water droplet was studied in terms of normalized droplet diameter($d/d_0$), droplet diameter(d) variation and droplet volume(V) variation under different ultrasonic frequency(f) conditions. It was revealed that increase of ultrasonic frequency reduces the droplet diameter. Therefore, it is able to levitate with low sound pressure level. It also induces the wide oscillation range, large diameter and volume variation of water droplet. In conclusion, the increase of ultrasonic frequency(f) can enhance the atomization performance of single water droplet.

고속 평면제트에 의한 쐐기음의 특성 연구 (A Study on the Characteristics of Edgetones by High-Speed Plane Jets)

  • 권영필;이근희;장욱;김욱
    • 대한기계학회논문집A
    • /
    • 제25권12호
    • /
    • pp.2100-2108
    • /
    • 2001
  • The impinging tones by high-speed plane jets are experimentally investigated to study the edgetone characteristics. Experiment used a slit nozzle and a wedge system to generate edgetones. The jet in the experiment is varied from low to high subsonic speed to obtain the effect of the speed on the frequency characteristics of impinging tones. The experimental data obtained previously fur edgetones and platetones by various nozzles are compared with the present edgetone data. And the condition of tone generation, the frequency ranges, the effective source point and the sound pressure level are compared and discussed. It is found that the jet speed has no diect influence on the impinging tone characteristics. Regardless of the jet speed, the effective source point is about a quarter wavelength downstream from the edge tip. With increase in jet speed, the influence of the nozzle configuration is decreased and the operating frequencies show good coincidences by normalized parameters based on the slit thickness.