• Title/Summary/Keyword: Normal map

Search Result 384, Processing Time 0.028 seconds

A Study on Variation Types in Celiac Axis and Superior Mesenteric Artery using 3D Volume Rendering of MDCT (MDCT의 3차원 볼륨렌더링을 이용한 복강축과 위창자간막동맥의 변위 형태에 관한연구)

  • Lee, Jeong-Keun;Jang, Young-Ill;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.131-139
    • /
    • 2013
  • The aim of this study was to evaluate the variation which based on Celiac axis and SMA using by CT volume rendering images. 613 patients underwent abdominal CTA, there were 552 patients (99.05%, TypeI, II) with normal anatomical form and 61 (9.95%, Type III~XII) with variation. TypeI was 339(55.31%), Type II was 213 (34.74%), Type III was 18 (2.93%), Type IV was 12 patients (1.95%), Type V was 11 patient (1.79%), Type VI was 9 patients (1.46%), Type VII was 6 patients (0.97%), Type VIII was 1 patient (0.16%), Type IX was 1 patient (0.16%), Type X was 1 patient (0.16%), Type XI was 1 patient (0.16%), and Type XII was 1 patient (0.16%) into totally new types of variation. In conclusion, we could found 9 new types of variation by classifying based on celiac axis and superior mesenteric artery. These results were considered to be an important opportunity for a new vessel map.

A Study on Development of Technology Protection Rating Methodology using Statistics (통계기법을 적용한 기술보호 등급분류 방법론 개발 연구)

  • Yang, Jeong-Eun;Yang, Younggyu;Cho, YunGyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.671-678
    • /
    • 2021
  • In a previous study, technology protection levels were set on a qualitative basis. That study lacked quantitative standards, so here, we conduct a study to complement the previous study and to present an objective standard. This paper provides a method of setting a technical protection level that applies statistical analysis. To set the technology protection level, statistical analysis of six technical survey items is performed first. Second, the technical survey items are analyzed by AHP to quantify the opinions of experts in order to derive weights for each technical survey item. Finally, by using the normal distribution scatter map and median calculation method, the technology protection level is selected in three stages using the final detailed factor technology score reflecting the weight. The technology protection level methodology developed through this study is the first methodology with objectivity that can evaluate defense technology by level. If this methodology is applied in practice, it is believed that it will provide a scientific and quantitative technology value judgment criterion when setting the technology protection level in the future.

A Study on the Hyun-Mu Sutra(玄武經) of Jeungsan (증산계 『현무경』 연구)

  • Koo, Jung-hoe
    • Journal of the Daesoon Academy of Sciences
    • /
    • v.25_1
    • /
    • pp.25-85
    • /
    • 2015
  • In this study, source criticism (an establishment of authentic text) of the Hyun-Mu Sutra(玄武經) among different editions is studied and an attempt of a new interpretation appropriate to that is attempted. The Hyun-Mu Sutra, a scripture written in 1909, began to communicate with the world through the religions of Jeungsanism. In particular, it was remarkable that The Hyun-Mu Sutra was absorbed as canon textbooks Jeonkyung(典經), the Scriptures of Daesoonjinrihoe, The Fellowship of Daesoon Truth(大巡眞理) from a loner and secret pull-out of heritage traditions. However, this scripture though written in 1909 and more than 100 years has passed, remained in a state unestablished authentic text. The Hyun-Mu Sutra is the scripture consisted of 25 pages by the religions of Jeungsanism[Gang Il-sun 姜一淳(1871~1909)]. 33 page type of Hyun-Mu Sutra has been distributed in the world until now the authentic text of The Hyun-Mu Sutra. However, as a result of the examination, diagnostic scripture(病勢文) was found to have been added by descendants. After a review of authentic text of The Hyun-Mu Sutra, it concluded that there is no diagnostic scripture in primary The Hyun-Mu Sutra. Though The Hyun-Mu Sutra is a booklet of a small amount, the notation and expression is so unique, it has been in secrecy to read its contents. Interpretation way of The Hyun-Mu Sutra up to now can be summarized in two as follows. 1) approaches by I-ching 2) approaches by ten celestrial stemps and twelve earthly branches(10干12支). Approaches by I-ching among this sometimes was supplemented with Buddhist classification methods. Nevertheless, these studies can be evaluated limited because it fails to secure authentic text of The Hyun-Mu Sutra. In this study, the contents of The Hyun-Mu Sutra was examined itemized by focusing on the following four points. 1) The icon of The Hyun-Mu Sutra(玄武經符) is similar as normal talisman(符籍) but it has other features. 2) 'Reverse Fonts'(反書體)[the opposite view of the standard fonts(正書體), reflected in the mirror fonts] and size or location used in text is not in uniform. 3) letters in scripture were pointed and points were stamped in the left and upper and lower characters. 4) "Spiritual poem" (詠歌, the Korean traditional music with a view of elegance as an origin of eco), and the music with the Five-Sounds[宮Gung, 商Sang, 角Gak, 徵Chi, 羽Wu) were related. As a result, content analysis of The Hyun-Mu Sutra is carried out in the next four points. 1) The icon of The Hyun-Mu Sutra (玄武經符) has been primarily developed by Jeungsan. 2) 'Reverse Fonts'(反書體)[the opposite view of the standard fonts(正書體), reflected in the mirror fonts] and reverse location such as '宙宇' [the reverse of '宇宙'] represents based on a new world based on a forward and reverse I-ching(正易). 3) Dot and neighbor points is a symbolic map that guides the position of lateral new world(後天) and era(人尊) 4) Spiritual poem is the entrance to achieve the Realization of Do(道通). The above can be considered as the results of this study.

A Method for Estimating the Lung Clinical Target Volume DVH from IMRT with and without Respiratory Gating

  • J. H. Kung;P. Zygmanski;Park, N.;G. T. Y. Chen
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.53-60
    • /
    • 2002
  • Motion of lung tumors from respiration has been reported in the literature to be as large as of 1-2 cm. This motion requires an additional margin between the Clinical Target Volume (CTV) and the Planning Target Volume (PTV). While such a margin is necessary, it may not be sufficient to ensure proper delivery of Intensity Modulated Radiotherapy (IMRT) to the CTV during the simultaneous movement of the DMLC. Gated treatment has been proposed to improve normal tissues sparing as well as to ensure accurate dose coverage of the tumor volume. The following questions have not been addressed in the literature: a) what is the dose error to a target volume without gated IMRT treatment\ulcorner b) what is an acceptable gating window for such treatment. In this study, we address these questions by proposing a novel technique for calculating the 3D dose error that would result if a lung IMRT plan were delivered without gating. The method is also generalized for gated treatment with an arbitrary triggering window. IMRT plans for three patients with lung tumor were studied. The treatment plans were generated with HELIOS for delivery with 6 MV on a CL2100 Varian linear accelerator with a 26 pair MLC. A CTV to PTV margin of 1 cm was used. An IMRT planning system searches for an optimized fluence map ${\Phi}$ (x,y) for each port, which is then converted into a dynamic MLC file (DMLC). The DMLC file contains information about MLC subfield shapes and the fractional Monitor Units (MUs) to be delivered for each subfield. With a lung tumor, a CTV that executes a quasi periodic motion z(t) does not receive ${\Phi}$ (x,y), but rather an Effective Incident Fluence EIF(x,y). We numerically evaluate the EIF(x,y) from a given DMLC file by a coordinate transformation to the Target's Eye View (TEV). In the TEV coordinate system, the CTV itself is stationary, and the MLC is seen to execute a motion -z(t) that is superimposed on the DMLC motion. The resulting EIF(x,y)is inputted back into the dose calculation engine to estimate the 3D dose to a moving CTV. In this study, we model respiratory motion as a sinusoidal function with an amplitude of 10 mm in the superior-inferior direction, a period of 5 seconds, and an initial phase of zero.

  • PDF

Mapping Mammalian Species Richness Using a Machine Learning Algorithm (머신러닝 알고리즘을 이용한 포유류 종 풍부도 매핑 구축 연구)

  • Zhiying Jin;Dongkun Lee;Eunsub Kim;Jiyoung Choi;Yoonho Jeon
    • Journal of Environmental Impact Assessment
    • /
    • v.33 no.2
    • /
    • pp.53-63
    • /
    • 2024
  • Biodiversity holds significant importance within the framework of environmental impact assessment, being utilized in site selection for development, understanding the surrounding environment, and assessing the impact on species due to disturbances. The field of environmental impact assessment has seen substantial research exploring new technologies and models to evaluate and predict biodiversity more accurately. While current assessments rely on data from fieldwork and literature surveys to gauge species richness indices, limitations in spatial and temporal coverage underscore the need for high-resolution biodiversity assessments through species richness mapping. In this study, leveraging data from the 4th National Ecosystem Survey and environmental variables, we developed a species distribution model using Random Forest. This model yielded mapping results of 24 mammalian species' distribution, utilizing the species richness index to generate a 100-meter resolution map of species richness. The research findings exhibited a notably high predictive accuracy, with the species distribution model demonstrating an average AUC value of 0.82. In addition, the comparison with National Ecosystem Survey data reveals that the species richness distribution in the high-resolution species richness mapping results conforms to a normal distribution. Hence, it stands as highly reliable foundational data for environmental impact assessment. Such research and analytical outcomes could serve as pivotal new reference materials for future urban development projects, offering insights for biodiversity assessment and habitat preservation endeavors.

Effects of Contrast Phases on Automated Measurements of Muscle Quantity and Quality Using CT

  • Dong Wook Kim;Kyung Won Kim;Yousun Ko;Taeyong Park;Jeongjin Lee;Jung Bok Lee;Jiyeon Ha;Hyemin Ahn;Yu Sub Sung;Hong-Kyu Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1909-1917
    • /
    • 2021
  • Objective: Muscle quantity and quality can be measured with an automated system on CT. However, the effects of contrast phases on the muscle measurements have not been established, which we aimed to investigate in this study. Materials and Methods: Muscle quantity was measured according to the skeletal muscle area (SMA) measured by a convolutional neural network-based automated system at the L3 level in 89 subjects undergoing multiphasic abdominal CT comprising unenhanced phase, arterial phase, portal venous phase (PVP), or delayed phase imaging. Muscle quality was analyzed using the mean muscle density and the muscle quality map, which comprises normal and low-attenuation muscle areas (NAMA and LAMA, respectively) based on the muscle attenuation threshold. The SMA, mean muscle density, NAMA, and LAMA were compared between PVP and other phases using paired t tests. Bland-Altman analysis was used to evaluate the inter-phase variability between PVP and other phases. Based on the cutoffs for low muscle quantity and quality, the counts of individuals who scored lower than the cutoff values were compared between PVP and other phases. Results: All indices showed significant differences between PVP and other phases (p < 0.001 for all). The SMA, mean muscle density, and NAMA increased during the later phases, whereas LAMA decreased during the later phases. Bland-Altman analysis showed that the mean differences between PVP and other phases ranged -2.1 to 0.3 cm2 for SMA, -12.0 to 2.6 cm2 for NAMA, and -2.2 to 9.9 cm2 for LAMA.The number of patients who were categorized as low muscle quantity did not significant differ between PVP and other phases (p ≥ 0.5), whereas the number of patients with low muscle quality significantly differed (p ≤ 0.002). Conclusion: SMA was less affected by the contrast phases. However, the muscle quality measurements changed with the contrast phases to greater extents and would require a standardization of the contrast phase for reliable measurement.

Prevalence and Risk Factors of Gallstones in Adult Health Screening Population (건강한 성인의 담석 유병률과 위험인자)

  • Lee, Mi-Hwa;Kwon, Duck-Moon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.287-294
    • /
    • 2014
  • Gallstone is the most common disease of the biliary system. Korean has experienced an increase in the percentage of cholesterol gallstones. The major risk factors associated with cholesterol gallstones are age, gender as well as obesity. This study was designed to determine the prevalence of gallstones in the last three years and evaluate the associated risk factors in the population who underwent health screening. The study population consisted of 2,484 males and 2,212 females who visited the health promotion center in Dalseogu, Daegu in Korea from January 2011 to December 2013. Each participant in the study had their biliary system gallbladder examined using ultrasonography. Classified as underweight, normal weight or overweight using the population of obese according to the body mass index, and classified according to mood diagnosis of diabetes presented by the American Diabetes Association. Fasting blood glucose and number of liver function, the divided the control group by referring to the normal liver function values used herein. The geological map, I was classified as NCEP APT III. A showed of total 148 people were found to have gallstones. The prevalence of sex among 148 patients (3.15%) 84 men (1.79%) and 64 women 1.36%) which shows significantly there is little difference. 1.84% 40 years and below, 3.38% 40's showed age prevalence was 4.66% in 50's and above. In addition, Total-cholesterol was at the most in 52 people, LDL-cholesterol in 398 people, Triglyceride in 36 people, HDL-cholesterol in 19 people. The abnormal group, was created from the total-cholesterol categories from a physical examination of a subject that has been found to be gallstones in the gallbladder. A result of conducting the univariate analysis shows the prevalence of gallstones, a correlation that is meaningful. The logistic regression analysis of multiple ages was chosen to show risk factors age independent cholelithiasis. In spite of the conclusion, gallstones are not displayed in relation to the metabolic syndrome but in order to clarify this, not only the subject of a health examination is needed but, a further study of the general public when possible.

Study of Prediction Model Improvement for Apple Soluble Solids Content Using a Ground-based Hyperspectral Scanner (지상용 초분광 스캐너를 활용한 사과의 당도예측 모델의 성능향상을 위한 연구)

  • Song, Ahram;Jeon, Woohyun;Kim, Yongil
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_1
    • /
    • pp.559-570
    • /
    • 2017
  • A partial least squares regression (PLSR) model was developed to map the internal soluble solids content (SSC) of apples using a ground-based hyperspectral scanner that could simultaneously acquire outdoor data and capture images of large quantities of apples. We evaluated the applicability of various preprocessing techniques to construct an optimal prediction model and calculated the optimal band through a variable importance in projection (VIP)score. From the 515 bands of hyperspectral images extracted at wavelengths of 360-1019 nm, 70 reflectance spectra of apples were extracted, and the SSC ($^{\circ}Brix$) was measured using a digital photometer. The optimal prediction model wasselected considering the root-mean-square error of cross-validation (RMSECV), root-mean-square error of prediction (RMSEP) and coefficient of determination of prediction $r_p^2$. As a result, multiplicative scatter correction (MSC)-based preprocessing methods were better than others. For example, when a combination of MSC and standard normal variate (SNV) was used, RMSECV and RMSEP were the lowest at 0.8551 and 0.8561 and $r_c^2$ and $r_p^2$ were the highest at 0.8533 and 0.6546; wavelength ranges of 360-380, 546-690, 760, 915, 931-939, 942, 953, 971, 978, 981, 988, and 992-1019 nm were most influential for SSC determination. The PLSR model with the spectral value of the corresponding region confirmed that the RMSEP decreased to 0.6841 and $r_p^2$ increased to 0.7795 as compared to the values of the entire wavelength band. In this study, we confirmed the feasibility of using a hyperspectral scanner image obtained from outdoors for the SSC measurement of apples. These results indicate that the application of field data and sensors could possibly expand in the future.

Geomagnetic Field Distribution in the Korean Peninsula by Spherical Harmonic Analysis (구면조화해석(球面調和解析)에 의(依)한 한반도내(韓半島內)의 지구자기장(地球磁氣場)의 분포(分布)에 관(關)한 연구(硏究))

  • Min, Kyung Duck;Lee, Sunhee
    • Economic and Environmental Geology
    • /
    • v.12 no.2
    • /
    • pp.95-104
    • /
    • 1979
  • The position of any point on the earth's surface can be. represented in the spherical coordinates by surface spherical harmonics. Since geomagnetic field is a function of position on the earth, it can be also expressed by spherical harmonic analysis as spherical harmonics of trigonometric series of $a_m({\theta})$ cos $m{\phi}$ and $b_m({\theta})$ sin $m{\phi}$. Coefficients of surface spherical harmonics, $a_m({\theta})$ and $b_m({\theta})$, can be drawn from the components of the geomagnetic field, declination and inclination, and vice versa. In this paper, components of geomagnetic field, declination and inclination in the Korean peninsula are obtained by spherical harmonic analysis using the Gauss coefficients calculated from the world-wide magnetic charts of 1960. These components correspond to the values of normal geomagnetic field having no disturbances of subsurface mass, structure, and so on. The vertical and total components offer the zero level for the interpretation of geomagnetic data obtained by magnetic measurement in the Korean peninsula. Using this zero level, magnetic anomaly map is obtained from the data of airborne magnetic. prospecting carried out during 1958 to 1960. The conclusions of this study are as follows; (1) The intensity of horizontal component of normal geomagnetic field in Korean peninsula ranges from $2{\times}10^4$ gammas to $2.45{\times}10^4$ gammas. It decreases about 500 with the increment of $1^{\circ}$ in latitude. Along the same. latitude, it increases 250 gammas with the increment of $1^{\circ}$ in longitude. (2) Intensity of vertical component ranges from $3.85{\times}10^4$ gammas to $5.15{\times}10^4$ gammas. It increases. about 1000 gammas with the increment of $1^{\circ}$ in latitude. Along the same latitude, it decreases. 150~240 gammas with the increment of $1^{\circ}$ in longitude. Decreasing rate is considerably larger in higher latitude than in lower latitude. (3) Total intensity ranges from $4.55{\times}10^4$ gammas to $5.15{\times}10^4$ gammas. It increases 600~700 gammas with the increament of $1^{\circ}$ in latitude. Along the same latitude, it decreases 10~90 gammas. with the increment of $1^{\circ}$ in longitude. Decreasing rate is considerably larger in higher latitude as the case of vertical component. (4) The declination ranges from $-3.8^{\circ}$ to $-11.5^{\circ}$. It increases $0.6^{\circ}$ with the increment of $1^{\circ}$ in latitude. Along the same latutude, it increases $0.6^{\circ}$ with the increment of l O in longitude. Unlike the cases of vertical and total component, the rate of change is considerably larger in lower latitude than in higher latitude. (5) The inclination ranges from $57.8^{\circ}$ to $66.8^{\circ}$. It increases about $1^{\circ}$ with 'the increment of $1^{\circ}$ in latitude Along the same latitude, it dereases $0.4^{\circ}$ with the increment of $1^{\circ}$ in longitude. (6) The Boundaries of 5 anomaly zones classified on the basis of the trend and shape of anomaly curves correspond to the geologic boundaries. (7) The trend of anomaly curves in each anomaly zone is closely related to the geologic structure developed in the corresponding zone. That is, it relates to the fault in the 3rd zone, the intrusion. of granite in the 1st and 5th zones, and mountains in the 2nd and 4th zones.

  • PDF

Clinical Usefulness of Arterial Spin Labeling Perfusion MR Imaging in Acute Ischemic Stroke (급성 허혈성 뇌경색 환자에서 동맥스핀표지 관류자기공명영상의 유용성)

  • Oh, Keun-Taek;Jung, Hong-Ryang;Lim, Cheong-Hwan;Cho, Young-Ki;Ha, Bon-Chul;Hong, Doung-Hee
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.323-331
    • /
    • 2011
  • We evaluated clinical usefulness of Arterial spin labeling perfusion MR imaging on the acute ischemic cerebral infarction patients through this study. We compared 22 patients who were done with DSC imaging and ASL imaging in admitted emergency room with acute ischemic cerebral infarction, with 36 normal comparison persons (DSC image on 21persons, ASL images on 15persons). Siemens Magnetom Verio 3.0T with 12 channel head coil was used for this study. DSC image obtained 4 maps(rCBV, rCBF, rMTT, TTP) through post-processing. For qualitative analysis we compared the area of lesion macro-diagonal with the size of diffusion weighted MR image for rMTT, TTP, rCBF, rCBV, ASL maps. For Quantitative analysis we analyzed significant correlations between less than 3 cm infarction group and normal comparison group using mean relative value of flowing image with Mann-Whitney U test. TTP(95.5%) and rCBF(95.5%) maps showed high recognition rate in qualitative analysis for >3cm infarction group. The rCBF and rCBV map tests were highly related with final stage stroke areas. Mean relative value of infarction group showed a significant correlations in quantitative analysis(p<0.05). As a conclusion, arterial spin labeling image showed high lesion recognition rate in the >3cm infarction group. Mean relative values in quantitative evaluation were used for reference data. If we do more sustainable researches, ASL image will be useful for an early diagnosis of cerebral infarction, determination of the range of ischemic pneumbra and effective treatments.