• 제목/요약/키워드: Nonparametric testing

검색결과 83건 처리시간 0.017초

Relationship between sonorheometry parameters and laboratory values in a critical care setting in Italy: a retrospective cohort study

  • Antonio Romanelli;Renato Gammaldi;Alessandro Calicchio;Salvatore Palmese;Antonio Siglioccolo
    • Journal of Trauma and Injury
    • /
    • 제36권3호
    • /
    • pp.210-216
    • /
    • 2023
  • Purpose: This preliminary retrospective cohort study analyzed the relationship between the parameters provided by sonorheometry device Quantra and the coagulation values obtained from standard venous blood samples in patients admitted in intensive care unit (ICU). Methods: We reviewed medical charts of 13 ICU adult patients in whom at least one coagulation study with Quantra was performed. The relationship between Quantra and laboratory data was analyzed with the Spearman rank correlation coefficient (rho). The 95% confidence interval (CI) was computed. A P-value <0.05 was considered statistically significant. Results: We collected 28 data pairs. Statistically significant moderate correlations were found for the following parameters: clot time (CT) and activated partial thromboplastin time (rho=0.516; 95% CI, 0.123-0.904; P=0.009; clot stiffness (CS) and the international normalized ratio (INR; rho=0.418; 95% CI, 0.042-0.787; P=0.039); INR and platelet contribution to CS (rho=0.459; 95% CI, 0.077-0.836; P=0.022); platelet count and platelet contribution to CS (PCS; rho=0.498; 95% CI, 0.166-0.825; P=0.008); and fibrinogen and fibrinogen contribution to CS (FCS; rho=0.620; 95% CI, 0.081-0.881; P=0.001). Conclusions: Quantra can provide useful information regarding coagulation status, showing modest correlations with the parameters obtained from laboratory tests. During diffuse bleeding, CT and FCS values can guide the proper administration of clotting factors and fibrinogens. However, the correlation of INR with CS and PCS can cause misinterpretation. Further studies are needed to clarify the relationship between Quantra parameters and laboratory tests in the critical care setting and the role of sonorheometry in guiding targeted therapies and improving outcomes.

A COMPARATIVE STUDY OF THE 1-PIECE AND 2-PIECE CONICAL ABUTMENT JOINT: THE STRENGTH AND THE FATIGUE RESISTANCE

  • Kwon, Taek-Ka;Yang, Jae-Ho;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.780-786
    • /
    • 2007
  • Statement of problem. The performance and maintenance of implant-supported prostheses are primarily dependent upon load transmission both at the bone-to-implant interface and within the implant-abutment-prosthesis complex. The design of the interface between components has been shown to have a profound influence on the stability of screw joints. Purpose. The Purpose of this study was to compare the strength and the fatigue resistance of 1-piece and 2-piece abutment connected to oral implant, utilizing an internal conical interface. Material and methods. Twenty $Implatium^{(R)}$ tapered implants were embedded to the top of the fixture in acrylic resin blocks. Ten $Combi^{(R)}$(1-piece) and $Dual^{(R)}$(2-piece) abutments of the same dimension were assembled to the implant, respectively. The assembled units were mounted in a testing machine. A load was applied perpendicular to the long axis of the assemblies and the loading points was at the distance of 7mm from the block surface. Half of 1-piece and 2-piece abutment-implant units were tested for the evaluation of the bending strength, and the others were cyclically loaded for the evaluation of the fatigue resistance until plastic deformation occurred. Nonparametric statistical analysis was performed for the results. Results. Mean plastic and maximum bending moment were $1,900{\pm}18Nmm,\;3,609{\pm}106Nmm$ for the 1-piece abutment, and $1,250{\pm}31Nmm,\;2,688{\pm}166Nmm$ for the 2-piece abutment, respectively. Mean cycles and standard deviation when implant-abutment joint showed a first plastic deformation were $238,610{\pm}44,891$. cycles for the 1-piece abutment and $9,476{\pm}3,541$ cycles for the 2-piece abutment. A 1-piece abutment showed significantly higher value than a 2-piece abutment in the first plastic bending moment (p<.05), maximum bending moment (p<.05) and fatigue strength (p<.05). Conclusion. Both 1-piece and 2-piece conical abutment had high strength and fatigue resistance and this suggests long-term durability without mechanical complication. However, the 1-piece conical abutment was more stable than the 2-piece conical abutment in the strength and the fatigue resistance.

Adriamycin을 사용한 환아에서 심초음파를 이용한 좌심실 기능의 평가 : 심근 수축력의 부하 비의존족 지표 및 휴식시와 운동시의 비교 (Assessment of Left Ventricular Function with Echocardiography in Patients Treated with Adriamycin : A Load-Independent Index of Myocardial Contractility and Comparisons between Rest and Exercise)

  • 박병수;박혜영;이해용
    • Clinical and Experimental Pediatrics
    • /
    • 제45권2호
    • /
    • pp.214-222
    • /
    • 2002
  • 목 적 : Anthracylines계 약물은 매우 효과적이며 널리 사용되고 있는 항암제이다. 그러나 심근손상이라는 중요한 합병증이 있으며 이는 종종 중하거나 심지어는 치명적이다. 본 연구의 목적은 anthracyacline을 사용했던 소아 암환자에서 비침습적이고 비교적 안전한 심장초음파를 이용하여, 기존의 지표에 비해 좀 더 정확하고 주위변수의 영향을 덜 받으면서 심근손상 여부를 판정하기 위해 고안되었다. 방 법 : Adriamycin을 투여 받았던 17명의 환자군과 20명의 대조군을 대상으로 좌심실 내경, 심실벽 긴장도 그리고 수축기능이 평가되었다. 17명의 환자에 대해서는 2번에 걸쳐 검사가 시행되었는데, 휴식상태(group 1)와 운동을 하고 난후(group 2)에 검사를 각각 시행하였다. 결 과 : 이완기 말 좌심실 내경은 두 군에서 모두 정상 대조군에 비해 감소된 소견을 보였고 통계적으로 의미가 있었다. 그러나 두 군간의 통계적인 차이는 없었다. 이완기 말 좌심실 용적과 심실벽 크기는 두군에서 정상 대조군에 비해 감소된 소견을 보였으며, 통계적으로 모두 의미가 있었다. Group 2에서 group 1보다 낮은 값을 보였으나, 두 군간의 통계적인 의미는 없었다. 수축기말 경선 긴장도는 두 군에서 모두 증가하였으며, group 1에서 group 2 보다 낮은 값을 보였으나, 두 군간의 통계적인 의미는 없었다. 분획단축으로 평가된 수축능력은 group 1에서는 17명 중 5명(29%)에서 비정상적인 결과를 나타내었고, group 2에서는 17명 중 6명(35%)에서 수축능력의 이상을 나타내었다. 그러나 nonparametric testing으로 검정한 결과 두 군간의 특이한 차이는 없었다. 한편, 부하 비의존적 지표인 원주상 섬유 단축속도와 수축기말 경선 긴장도와의 관계에 있어서는 두 군간에 차이가 있음이 관찰되었는데, group 1에서 17명 중 7명(41%), group 2에서는 17명 중 12명(71%)에서 현저한 비정상 변화를 보였으며, 이는 통계적으로 의미가 있었다. 결 론 : 분획단축과 같은 부하 의존적 수축기 지표는 전부하 혹은 후부하의 보상적 변화에 의해서 비정상소견을 보이지 않을 수 있으며, 이로 인해 수축력의 장애가 가려질 수 있다. 따라서 부하 비의존적 지표인 수축기 말 압력과 내경과의 기울기 관계 및 운동 후 수축기말 심실벽 긴장에 따른 원주상 섬유 단축속도의 변화를 규명함으로써 심장의 수축능력을 지속적으로 감시하는 것이 심근손상의 조기발견에 도움이 될 것으로 생각된다.