• 제목/요약/키워드: Nonlinearity Vibration Test

검색결과 12건 처리시간 0.025초

수치적 시뮬레이션과 충격 시험을 통한 수직방향 진동절연 완충기 설계 및 성능 평가 (Design and Performance Evaluation of the Vibration Absorber of Vertical Direction Using Numerical Simulation and Shock Test)

  • 박상길;방승우;권오철;이정윤;오재응
    • 한국소음진동공학회논문집
    • /
    • 제18권5호
    • /
    • pp.558-563
    • /
    • 2008
  • Vibration/shock affects biggest taking a train subtraction of vehicle and durability decline. Therefore, absorber is used for vibration/shock isolation and various qualities of the material and design are applied to isolation. This paper proposes vibration/shock absorber that applies 'Disc' spring. Through comparison with 'Disc' spring that has nonlinearity and coil spring that is having linearity, see effect that nonlinearity of isolation gets in vibration/shock Isolation. Coil spring and 'Disc' spring are non-linear numerical analysis and simulation through theory for this, get and investigate comparison result through an experiment finally. Expressed and formulated shock through 'Runge-Kutta' method/impact response to nonlinear-vibration-equation of 1 degree of freedom for numerical analysis. Double half sine pulse of excitation used and analyzed result through spectrum response analysis here. Response of disc spring is compared to response of coil spring by changing $h_o/t$ ratio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and to design the optimal absorber under the limited condition. And then, the isolation effect was analyzed through the shock test.

수치 모델링과 충격 시험을 통한 수직방향 진동절연 완충기의 성능 평가 (Performance Evaluation of the Vibration Absorber of Vertical Direction using Numerical Modeling and Shock Test)

  • 박상길;방승우;권오철;이정윤;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.990-993
    • /
    • 2008
  • Vibration/shock affects biggest taking a train subtraction of vehicle and durability decline. Therefore, absorber is used for vibration/shock isolation and various qualities of the material and design are applied to isolation. This paper proposes vibration/shock absorber that applies 'Disc'spring. Through comparison with 'Disc' spring that has nonlinearity and coil spring that is having linearity, see effect that nonlinearity of isolation gets in vibration/shock isolation. Coil spring and 'Disc' spring are non-linear numerical analysis and simulation through theory for this, get and investigate comparison result through an experiment finally. Expressed and formulated shock through 'Runge-Kutta' method/impact response to nonlinear-vibration-equation of 1 degree of freedom for numerical analysis. Double half sine pulse of excitation used and analyzed result through spectrum response analysis here. Response of disc spring is compared to response of coil spring by changing ho/t ratio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and to design the optimal absorber under the limited condition. And then, the isolation effect was analyzed through the shock test.

  • PDF

결합부 유연성에 따른 감쇠거동에 관한 고찰 : 히스테레틱 감쇠 (Estimations of the Hysteretic Damping by Controlled Joint Flexibilities)

  • 윤성호
    • 소음진동
    • /
    • 제9권2호
    • /
    • pp.258-264
    • /
    • 1999
  • The purpose of this paper is to investigate the damping behavior of a flexible joint. The slip at a structrual joint is selected at the tips of two identical cantilever beams adjoining each other. Both the direction of normal force and its magnitude varies due to the global deformation of the structure from mode to mode in the friction model. The friction dependent on vibration displacements resultsin the same functional behavior of the hysteretic material damping. Linearized energy loss factors are obtained as functions of both linear and torsional spring stiffness for their groups of symmetric and anti-symmetric modes, respectively. Experimental measurements as made for comparisons with analytical estimations by controlling the magnitude of fastening torque in the fastener, Hi-Lite. Trends on damping levelsmeasured in a very common vibration test method make an excellent agreement on the estimated damping levels.

  • PDF

LAP 구조물 결합부의 설계치 확보를 위한 동역학적 해석 (Dynamic Analysis of Design Data for Structural Lap Joint)

  • 윤성호
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.57-74
    • /
    • 1998
  • 구조체의 연결부위에서 미지의 결합강성으로 인하여, 실험과 유한 요소법으로 구한 모달 매개변수들은 종종 일치하지 않는다. 본 논문은 실험으로 추출된 동특성 데이타에 근거하여, 해석적인 방법을 통해 새로운 모델링 방법을 제시하고 있다. 대표적인 연결방법으로 리벳을 이용한 Lap이음보에서 동강성을 측정하기 위한 비선형 진동실험이 제안 되었으며, 이를 Lap 이음판에 적용하기 위하여 동강성에 해당하는 설계변수로서 빔요소를 도입하였다. 이 유한요소 모델링은 범용 패키지인 PATRAN과 ABAQUS를 사용하였으며, 빔요소의 직경을 실험치의 고유진동수와 일치하도록 조절함으로써 직경의 최적치 경향을 관찰하였다. 제시된 모델링 기법과 기존의 모델링 기법으로 얻은 결과치들을 실험치와 비교하였다.

  • PDF

차량 구조물 안전설계를 위한 진동특성에 관한 연구 (A Study on the Vibration Characteristics for Safety Design of Vehicle Structure)

  • 신귀수;이기형
    • 한국안전학회지
    • /
    • 제13권2호
    • /
    • pp.13-21
    • /
    • 1998
  • This is a study on the natural vibration characteristics of Vehicle frame. Nowadays, many trucks freight the over-load, do the car designers consider the over-load about 200% in the design. It's necessary to make the model of a vehicle and simulate it for the test of driving condition, durability and vibration behavior before the vehicle is manufactured. If it is possible to make a simulation using the static and dynamic analysis, this is very useful in accomplishing an optimal design of the vehicle. In this paper, we studied the vibration characteristics of a truck body frame. The automobile body frame model for experiment is made smaller than real size frame with the ratio of 1/10. The vibration characteristics of a frame is considered as one of main factors in analyzing and improving the problem for ride comfort, noise and vibration reduction. Therefore, we experimented two method to neglect the nonlinearity. First is bolting and second is welding at the joint section. We compared computer simulation results and experimental data.

  • PDF

5$\times$5 봉다발의 감쇄추정을 위한 실험적 연구 (Experimental study on the damping estimation of the 5$\times$5 rod bundle)

  • 이강희;윤경호;송기남
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.503-506
    • /
    • 2005
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle (5$\times$5) is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid like the coolant mixing performance and to obtain the Flow-Induced Vibration (FIV) characteristics of the rod bundle over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the bundle prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the small scaled test bundle. For the damping factor of the rod bundle and the grid case at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the rod bundle is about 0.7% with reasonable error of 2% for the previous results. Nonlinear behavior of the rod bundle might be stem mainly Iron the rod-grid support configuration.

  • PDF

5×5 부분핵연료 집합체의 감쇠추정을 위한 실험적 연구 (Experimental Study on the Damping Estimation of the 5×5 Partial Fuel Assembly)

  • 이강희;윤경호;송기남
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.163-168
    • /
    • 2006
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle $(5\times5)$ which is called partial fuel assembly is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid to obtain the Flow-Induced Vibration (FIV) characteristics of the scaled fuel assembly over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the assembly prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the scaled test assembly. For the damping factor of the partial fuel assembly and the grid cage at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the partial fuel assembly is about $0.7\%$ with reasonable error of $2\%$ for the previous results. Nonlinear behavior of the partial fuel assembly might be stem mainly from the rod-grid support configuration.

New three-layer-type hysteretic damper system and its damping capacity

  • Kim, Hyeong Gook;Yoshitomi, Shinta;Tsuji, Masaaki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제3권6호
    • /
    • pp.821-838
    • /
    • 2012
  • This paper proposes a new three-layer pillar-type hysteretic damper system for residential houses. The proposed vibration control system has braces, upper and lower frames and a damper unit including hysteretic dampers. The proposed vibration control system supplements the weaknesses of the previously proposed post-tensioning vibration control system in the damping efficiency and cumbersomeness of introducing a post-tension. The structural variables employed in the damper design are the stiffness ratio ${\kappa}$, the ductility ratio ${\mu}_a$, and the ratio ${\beta}$ of the damper's shear force to the maximum resistance. The hysteretic dampers are designed so that they exhibit the targeted damping capacity at a specified response amplitude. Element tests of hysteretic dampers are carried out to examine the mechanical property and to compare its restoring-force characteristic with that of the analytical model. Analytical studies using an equivalent linearization method and time-history response analysis are performed to investigate the damping performance of the proposed vibration control system. Free vibration tests using a full-scale model are conducted in order to verify the damping capacity and reliability of the proposed vibration control system. In this paper, the damping capacity of the proposed system is estimated by the logarithmic decrement method for the response amplitudes. The accuracy of the analytical models is evaluated through the comparison of the test results with those of analytical studies.

비선형 공진기법을 이용한 콘크리트의 화재 손상 영향인자 분석 (Analysis of Factors Influencing Fire Damage to Concrete Using Nonlinear Resonance Vibration Method)

  • 박강규;박선종;임홍재;곽효경
    • 비파괴검사학회지
    • /
    • 제35권2호
    • /
    • pp.150-156
    • /
    • 2015
  • 본 연구에서는 비선형 음향효과를 기반으로 한 비선형 공진기법을 도입하여 콘크리트의 배합비 및 화재 손상 조건(노출온도, 손상 후 경과기간)이 화재 손상 콘크리트에 미치는 영향을 파악하였다. 도입된 비선형 공진기법을 통해 기존 선형 탄성파 기반 평가 기법 대비 향상된 민감도를 나타내는 비선형인자를 측정하였으며, 쪼갬 인장강도 측정을 통해 배합비 및 화재 손상 조건에 따른 콘크리트의 잔존재료물성 평가를 수행하였다. 얻어진 결과를 토대로 배합비, 노출온도, 손상 후 경과기간이 화재 손상 콘크리트에 미치는 영향을 분석하였다. 추가적으로 쪼갬 인장강도비와 비선형인자의 직접적인 관계를 제시하였으며, 비선형 공진기법을 이용한 화재 손상 콘크리트의 잔존 강도 추정에 대한 가능성을 확인하였다.

Seismic response analysis of buried oil and gas pipelines-soil coupled system under longitudinal multi-point excitation

  • Jianbo Dai;Zewen Zhao;Jing Ma;Zhaocheng Wang;Xiangxiang Ma
    • Earthquakes and Structures
    • /
    • 제26권3호
    • /
    • pp.239-249
    • /
    • 2024
  • A new layered shear continuum model box was developed to address the dynamic response issues of buried oil and gas pipelines under multi-point excitation. Vibration table tests were conducted to investigate the seismic response of buried pipelines and the surrounding soil under longitudinal multi-point excitation. A nonlinear model of the pipeline-soil interaction was established using ABAQUS finite element software for simulation and analysis. The seismic response characteristics of the pipeline and soil under longitudinal multi-point excitation were clarified through vibration table tests and simulation. The results showed good consistency between the simulation and tests. The acceleration of the soil and pipeline exhibited amplification effects at loading levels of 0.1 g and 0.2 g, which significantly reduced at loading levels of 0.4 g and 0.62 g. The peak acceleration increased with increasing loading levels, and the peak frequency was in the low-frequency range of 0 Hz to 10 Hz. The amplitude in the frequency range of 10 Hz to 50 Hz showed a significant decreasing trend. The displacement peak curve of the soil increased with the loading level, and the nonlinearity of the soil resulted in a slower growth rate of displacement. The strain curve of the pipeline exhibited a parabolic shape, with the strain in the middle of the pipeline about 3 to 3.5 times larger than that on both sides. This study provides an effective theoretical basis and test basis for improving the seismic resistance of buried oil and gas pipelines.