• Title/Summary/Keyword: Nonlinear Load Current

Search Result 287, Processing Time 0.676 seconds

선형 및 비선형 부하 사용시 전류 및 부하불평형률에 대한 연구 (A Study on the Current & Load Unbalance Factor in using Linear & Nonlinear Load)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1291-1296
    • /
    • 2017
  • Single-phase and three-phase load can be used together in 3-phase 4-wire system. Single-phase and three-phase loads can be classified as linear loads without harmonics and nonlinear with harmonics. Single-phase linear loads are linear loads such as lamps and heat, and single-phase nonlinear loads are power converters such as rectifiers. It is recommended that the distribution of loads in the 3-phase, 4-wire distribution lines be evenly distributed within a certain range. However, harmonic currents generated in a nonlinear load flow on the neutral line and affect the phase current magnitude. The difference in the magnitude of the individual phase current due to the influence of the harmonic current present in the neutral line can produce a difference in current and load unbalance. In this study, current unbalance ratio and load unbalance ratio which can occur when a combination of linear and nonlinear loads are applied to 3-phase 4-wire distribution line are calculated.

PZT계 압전변압기의 공진특성과 전기적 성질 (Resonance characteristics and electrical properties of PZT-piezoelectric transformer)

  • 박순태;정수태;이종헌
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권1호
    • /
    • pp.27-34
    • /
    • 1995
  • The analysis of nonlinear equivalent circuit and the resonance characteristics of input current and output voltage were simulated, and their electrical properties are discussed in the transverse-type piezoelectric ceramic transformer. The nonlinear resonance characteristics of input current and output voltage showed by the thermal effect due to a higher driving current, the nonlinearity increased greatly as driving current increased. When load resistor was 100[M.ohm.], the nonlinear coefficient was -1.3. The nonlinear resonance curve of input current and output voltage for a variation of input voltage and load resistor agreed with the discussed theory. The output voltage increased nearly proportioned to input voltage when load resistors were below 50[M.ohm.], the voltage step-up ratio decreased when a load resistor was 100[M.ohm.] and their maximum value was 950.

  • PDF

3상 4선식 전력 시스템의 중성선 전류 분석 (Neutral Line Current Analysis of Three-phase Four-wire Power System)

  • 민준기;김형철;김수철;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.492-494
    • /
    • 2006
  • Neutral line current is analyzed by the neutral line CF in nonlinear load balanced and unbalanced conditions. The worst nonlinear load condition is nonlinear balanced load condition, and It is below CFNL=1.194 that a neutral line current could not excess the rated value

  • PDF

비선형 부하에서 커패시터 전류 궤환을 통한 고성능 UPS 설계 (A Design of a High Performance UPS with Capacitor Current Feedback for Nonlinear Loads)

  • 이우철;이택기
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.71-78
    • /
    • 2012
  • This paper presents a digital control solution to process capacitor current feedback of high performance single-phase UPS for non-linear loads. In all UPS the goal is to maintain the desired output voltage waveform and RMS value over all unknown load conditions and transient response. The proposed UPS uses instantaneous load voltage and filter capacitor current feedback, which is based on the double regulation loop such as the outer voltage control loop and inner current control loop. The proposed DSP-based digital-controlled PWM inverter system has fast dynamic response and low total harmonic distortion (THD) for nonlinear load. The control system was implemented on a 32bit Floating-point DSP controller TMS320C32 and tested on a 5[KVA] IGBT based inverter switching at 11[Khz]. The validity of the proposed scheme is investigated through simulation and experimental results.

3상 비선형 부하시 중성선 전류 해석 (Neutral Line Current Analysis in Three-phase Nonlinear Load Condition)

  • 민완기;김남오;김병철;전형석;신석두;김형곤;민준기;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 정기총회 및 학술대회 전문대학교육위원
    • /
    • pp.109-109
    • /
    • 2008
  • Neutral line current is analyzed by the neutral line CF in nonlinear load balanced and unbalanced conditions. The worst nonlinear load condition is nonlinear balanced load condition. and It is below CFNL=1.194 that a neutral line current could not excess the rated value.

  • PDF

전압 및 전류 고조파에 의한 커패시터 동작 특성 (A Study on the Characteristic of Capacitor by Voltage and Current Harmonics)

  • 김종겸;박영진;이동주;이은웅
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.257-262
    • /
    • 2009
  • Capacitor is basically used for the power-factor compensation and sometimes as the passive filter to reduce harmonics of nonlinear load. Since the impedance of capacitor is inversely proportional to the frequency. The harmonic current may result in the problems of voltage distortion and resonance. Capacitor has easily fall under by two harmonic components, a nonlinear load and a distorted utility voltage. The amplified harmonic current and voltage may damage power capacitor. Hence the pre-investigation of harmonic is needed before designing and application the power factor for reducing fault rate. In this paper, we analyzed that voltage and current with harmonics components act on the capacitor under the resonance condition. we concluded that both voltage and current harmonics have an bad effect on the capacitor and current harmonics is a bitter rather than effect by voltage harmonics.

전류 고조파에 기인하는 변압기 손실 해석 (Power Loss Analysis of Transformer Caused By Current Harmonics)

  • 장승용;한상훈;최재호
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.34-41
    • /
    • 2016
  • This study investigates transformer losses caused by current harmonics. Electrical transformers are designed to work under sinusoidal voltage and current waves at a rated frequency. Recently, various nonlinear loads, such as power electronic converters, are connected to a power system; these converters generate current harmonics. Current harmonics increase power loss in transformers, which results in several problems, including temperature increase of the transformer and insulation damage. These problems will eventually shorten the operational life of the transformer. In this study, different types of losses caused by current harmonics in three-phase transformers are studied under linear and nonlinear load conditions. Linear loads are simulated and experimented on using pure resistance load, whereas nonlinear loads are simulated and experimented on using a three-phase twelve-pulse thyristor full-bridge rectifier. The different types of losses in three-phase transformers are evaluated analytically through the experimental result and simulation in PSiM.

비선형부하에 의한 역률보상용 전력 커패시터의 고조파 문제 (Harmonic Problem in Power Capacitor for Power Factor Compensation due to the Nonlinear Loads)

  • 이동주;김종겸;이은웅;조연찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.840-841
    • /
    • 2008
  • Power capacitors are widely used to compensate the low power factor of the linear load and/or nonlinear load. Especially, nonlinear loads generates the harmonic current and it gives an undesirable effect on the power capacitors. In this paper, harmonic current from nonlinear load to the power capacitors is calculated by the computer simulation and it is compared with the experimental results.

  • PDF

저압 시스템에서 비선형 부하의 사용에 따른 고조파 전류 해석 (Analysis of harmonics current using non-linear load at low voltage system)

  • 김종겸;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.13-16
    • /
    • 2001
  • This paper describes the problems associated with the use of PWM ASDs to drive induction motors. A major effect of harmonic voltages and currents in induction motors is increased heating due to iron and copper losses at harmonic frequencies. The harmonic components thus affect the motor efficiency, and can also affect the torque developed. In order to investigate the effect of harmonics which is caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current. Measurement. results show that additional operation of linear load at the parallel bus in using nonlinear load such as ASD is helpful to the reduction of harmonic current.

  • PDF

Voltage Distortion Suppression for Off-grid Inverters with an Improved Load Current Feedforward Control

  • Geng, Yiwen;Zhang, Xue;Li, Xiaoqiang;Wang, Kai;Yuan, Xibo
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.716-724
    • /
    • 2017
  • The output voltage of an off-grid inverter is influenced by load current, and the voltage harmonics especially the 5th and 7th are increased with nonlinear loads. In this paper, to attenuate the output voltage harmonics of off-grid inverters with nonlinear loads nearby, a load current feedforward is proposed. It is introduced to a voltage control loop based on the Positive and Negative Sequence Harmonic Regulator (PNSHR) compensation to modify the output impedance at selective frequencies. The parameters of the PNSHR are revised with the output impedance of the off-grid inverter, which minimizes the output impedance of the off-grid inverter. Experimental results verify the proposed method, showing that the output voltage harmonics caused by nonlinear loads can be effectively suppressed.