• 제목/요약/키워드: Nonlinear Hysteretic Analysis

검색결과 161건 처리시간 0.022초

Seismic fragility analysis of conventional and viscoelastically damped moment resisting frames

  • Guneyisi, Esra Mete;Sahin, Nazli Deniz
    • Earthquakes and Structures
    • /
    • 제7권3호
    • /
    • pp.295-315
    • /
    • 2014
  • This paper presents the results of an analytical study on seismic reliability of viscoelastically damped frame systems in comparison with that of conventional moment resisting frame systems. In order to exhibit the reliability of the frame systems with viscoelastic dampers, seismic reliability analyses were carried out for steel framed buildings, 5 and 12 storeys in height, designed as: (a) Case 1: Conventional moment resisting frame, (b) Case 2: Frame with viscoelastic dampers providing supplemental effective damping ratio of 10%, and (c) Case 3: Frame with viscoelastic dampers providing supplemental effective damping ratio of 20%. Nonlinear time history analyses were utilized to develop seismic fragility curves whilst monitoring various performance objectives. To obtain robust estimators of the seismic reliability, a database including 15 natural earthquake ground motion records with markedly different characteristics was employed in the fragility analysis. The results indicate that depending upon the supplemental effective damping ratio, frames designed with viscoelastic dampers have considerably lower annual probability of exceedance of performance limit states for structural components, showing up to a five-fold reduction in comparison to conventionally designed moment resisting frame system.

강성저감형 비탄성 단자유도 구조물에 설치된 완전탄소성 감쇠기의 제진성능 (Seismic Control of Stiffness-degrading Inelastic SDOF Structures with Fully Elasto-Plastic Dampers)

  • 박지훈;김훈희;김기면
    • 한국지진공학회논문집
    • /
    • 제14권4호
    • /
    • pp.37-48
    • /
    • 2010
  • 본 논문에서는 철근콘크리트 구조물과 같이 강성저감으로 인해 낮은 에너지 소산능력을 갖는 구조물의 제진성능을 비선형시간이력해석을 통해 조사하였다. 원구조물은 modified Takeda 이력모델을 갖는 단자유도시스템으로 이상화하였고, 완전탄소성 모델로 이력감쇠장치를 모델링하였다. 수치해석결과의 통계를 기초로 등가선형화에 의한 제진응답 평가의 적용성을 검증하였고, 제진보강 구조물의 응답예측을 위한 경험식을 제시하였다. 결과적으로 등가선형화를 통한 변위응답 평가보다는 본 연구에서 제시한 경험식을 이용하여 요구연성도를 추정하는 것이 더 정확하다. 경험식에서 얻어진 적정 감쇠기 항복강도는 완전탄소성시스템에 대한 최적 항복강도와는 상당한 차이를 가진다. 획득 가능한 연성도 저감효과는 원구조물의 고유주기가 짧을수록, 지진의 상대적 강도가 약할수록 우수한 것으로 나타났다.

외부접합형 카고메 감쇠시스템을 사용한 철근콘크리트 라멘조 공동주택 비탄성 지진 응답 제어 (Inelastic Seismic Response Control of the RC Framed Apartment Building Structures Using Exterior-Installed Kagome Damping System)

  • 허무원;천영수;이상현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권3호
    • /
    • pp.58-65
    • /
    • 2016
  • 이 논문은 지진응답을 감소시키기 위해 외부설치형 카고메 감쇠시스템의 유효성을 비선형 동적 해석 결과를 통해 나타내었다. 이전의 연구에 의해 제안된 카고메 감쇠시스템을 활용하여 본 연구에서는 등방성, 이선형 이력특성 및 설치구성이 새롭게 제안하였다. 또한, 외부접합형 카고메 감쇠시스템의 여러 가지 효과를 15층 및 20층 철근콘크리트 라멘조 아파트를 대상으로 검증하였다. 원구조물에 대한 감쇠장치 지지구조물의 강성비, 감쇠장치의 수량 및 설치 층수는 설계변수로 고려하였다. 수치해석결과, EKDS는 기존의 한 방향 층간에 설치되는 감쇠시스템과 비교할 때 더 작은 수를 적용하여도 두 방향의 지진하중을 감소시키는데 매우 효과적임을 입증되었다.

모듈러 구조물의 해석 모델이 지진응답에 미치는 영향 (Influence of Analytical Models on the Seismic Response of Modular Structures)

  • 최경석;이호찬;김형준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권2호
    • /
    • pp.74-85
    • /
    • 2016
  • 모듈러 구조물은 관행적으로 철골 모멘트 저항골조와 유사한 횡력저항성능을 가진다는 가정하에 내진 설계된다. 하지만 모듈러 구조물은 중첩된 구조 부재와 단위 모듈의 체결을 위한 복잡한 접합 상세를 가지기 때문에 철골 모멘트 골조와 다른 하중 전달 메커니즘을 가진다. 본 연구에서는 중첩된 구조 부재 효과와 접합부의 거동 특성을 고려하여 총 4개의 구조해석 모델을 수립하였으며, 수립된 해석 모델을 이용하여 3층과 5층 표본 건물에 대한 비선형 정적 해석을 수행하였다. 표본 건물은 중첩된 구조 부재와 접합부의 이력 거동에 대한 모델링 방법에 따라 강성 및 강도의 차이가 발생하는 것으로 나타났다. 중첩된 구조 부재를 완전 합성, 모듈 간 접합부를 강접합으로 고려하여 설계된 모듈러 구조물은 횡 강성 및 강도가 과대 평가되는 것으로 나타났다. 뿐만 아니라 해석 결과를 통해 3층 이상의 모듈러 구조물은 철골 모멘트 저항골조와 비교하여 상대적으로 적은 초과 강도를 가지는 것을 확인할 수 있다.

Employing a fiber-based finite-length plastic hinge model for representing the cyclic and seismic behaviour of hollow steel columns

  • Farahi, Mojtaba;Erfani, Saeed
    • Steel and Composite Structures
    • /
    • 제23권5호
    • /
    • pp.501-516
    • /
    • 2017
  • Numerical simulations are prevalently used to evaluate the seismic behaviour of structures. The accuracy of the simulation results depends directly on the accuracy of the modelling techniques employed to simulate the behaviour of individual structural members. An empirical modelling technique is employed in this paper to simulate the behaviour of column members under cyclic and seismic loading. Despite the common modelling techniques, this technique is capable of simulating two important aspects of the cyclic and seismic behaviour of columns simultaneously. The proposed fiber-based modelling technique captures explicitly the interaction between the bending moment and the axial force in columns, and the cyclic deterioration of the hysteretic behaviour of these members is implicitly taken into account. The fiber-based model is calibrated based on the cyclic behaviour of square hollow steel sections. The behaviour of several column archetypes is investigated under a dual cyclic loading protocol to develop a benchmark database before the calibration procedure. The dual loading protocol used in this study consists of both axial and lateral loading cycles with varying amplitudes. After the calibration procedure, a regression analysis is conducted to derive an equation for predicting a varying calibrated modelling parameter. Finally, several nonlinear time-history analyses are conducted on a 6-story steel special moment frame in order to investigate how the results of numerical simulations can be affected by employing the intended modelling technique for columns instead of other common modelling techniques.

Reliability-based design of semi-rigidly connected base-isolated buildings subjected to stochastic near-fault excitations

  • Hadidi, Ali;Azar, Bahman Farahmand;Rafiee, Amin
    • Earthquakes and Structures
    • /
    • 제11권4호
    • /
    • pp.701-721
    • /
    • 2016
  • Base isolation is a well-established passive strategy for seismic response control of buildings. In this paper, an efficient framework is proposed for reliability-based design optimization (RBDO) of isolated buildings subjected to uncertain earthquakes. The framework uses reduced function evaluations method, as an efficient tool for structural reliability analysis, and an efficient optimization algorithm for optimal structural design. The probability of failure is calculated considering excessive base displacement, superstructure inter-storey drifts, member stress ratios and absolute accelerations of floors of the isolated building as failure events. The behavior of rubber bearing isolators is modeled using nonlinear hysteretic model and the variability of future earthquakes is modeled by applying a probabilistic approach. The effects of pulse component of stochastic near-fault ground motions, fixity-factor of semi-rigid beam-to-column connections, values of isolator parameters, earthquake magnitude and epicentral distance on the performance and safety of semi-rigidly connected base-isolated steel framed buildings are studied. Suitable RBDO examples are solved to illustrate the results of investigations.

전단이 RC 교각의 지진성능 및 파괴모드에 미치는 영향 (Influence of shear on seismic performance and failure mode of RC piers)

  • 이도형
    • 공학논문집
    • /
    • 제6권1호
    • /
    • pp.53-63
    • /
    • 2004
  • 본 연구에서는 지진하중을 받는 철근콘크리트 교각의 지진성능 및 파괴모드에 전단이 미치는 영향을 조사하였다. 본 연구에서 개발된 전단-축력간의 상호거동 이력응답 모델의 검증을 위하여 철근콘크리트 기둥 실험에 대한 비교해석을 수행하였다. 비교결과, 예측된 해석치는 전단에 관한 하중-변위 이력응답에 있어서 실험결과와 좋은 상관관계를 보여주었다. 아울러, 본 연구에서 개발된 모델을 이용하여 고베 지진에 의해서 손상된 철근콘크리트 교량의 비선형 시간이력 해석을 수행하였다. 교각의 변위응답에 관한 분석결과, 축력의 변화를 고려한 전단의 영향으로 인하여 최대변위가 상당히 증가하였고, 전반적인 교각 강성의 감소와 함께 진동주기의 증가를 유발한다는 것을 알 수 있었다. 따라서 전단과 축력의 영향을 동시에 고려한 응답에 철근콘크리트 교각의 지진손상 평가에 관해서 보다 나은 설명을 제공할 수 있을 것으로 사료된다.

  • PDF

Study on a seismic slit shear wall with cyclic experiment and macro-model analysis

  • Jiang, Huanjun;Lu, Xilin;Kwan, A.K.H.;Cheung, Y.K.
    • Structural Engineering and Mechanics
    • /
    • 제16권4호
    • /
    • pp.371-390
    • /
    • 2003
  • The concept of the seismic slit shear wall was proposed in the early 1990's. A series of experimental and theoretic studies on the wall with reinforced concrete short connecting beams cast in the slit were carried out. In this paper another type of slit shear wall is studied. It is one with vertical slit purposely cast within the wall, and the rubber belt penetrated by a part of web shear reinforcement as seismic energy-dissipation device is filled in the slit. Firstly, an experiment under cyclic loading was carried out on two shear wall models, one slit and the other solid. The failure mechanism and energy-dissipation capacity are compared between the two different models, which testifies the seismic performance of the slit wall improved significantly. Secondly, for engineering practice purpose, a macroscopic analytical model is developed to predict the nonlinear behavior of the slit shear wall under cyclic loading. The mechanical properties of each constituent elements of this model are based on the actual behavior of the materials. Furthermore, the effects of both the axial force and bending moment on the shear behavior are taken into account with the aid of the modified compression-field theory. The numerical results are verified to be in close agreement with the experimental measurements.

Mechanics model of novel compound metal damper based on Bi-objective shape optimization

  • He, Haoxiang;Ding, Jiawei;Huang, Lei
    • Earthquakes and Structures
    • /
    • 제23권4호
    • /
    • pp.363-371
    • /
    • 2022
  • Traditional metal dampers have disadvantages such as a higher yield point and inadequate adjustability. The experimental results show that the low yield point steel has superior energy dissipation hysteretic capacity and can be applied to seismic structures. To overcome these deficiencies, a novel compound metal damper comprising both low yield point steel plates and common steel plates is presented. The optimization objectives, including "maximum rigidity" and "full stress state", are proposed to obtain the optimal edge shape of a compound metal damper. The numerical results show that the optimized composite metal damper has the advantages such as full hysteresis curve, uniform stress distribution, more sufficient energy consumption, and it can adjust the yield strength of the damper according to the engineering requirements. In view of the mechanical characteristics of the compound metal damper, the equivalent model of eccentric cross bracing is established, and the approximate analytical solution of the yield strength and the yield displacement is proposed. A nonlinear simulation analysis is carried out for the overall aseismic capacity of three-layer-frame structures with a compound metal damper. It is verified that a compound metal damper has better energy dissipation capacity and superior seismic performance, especially for a damper with double-objective optimized shape.

Seismic response of complex 3D steel buildings with welded and post-tensioned connections

  • Reyes-Salazar, Alfredo;Ruiz, Sonia E.;Bojorquez, Eden;Bojorquez, Juan;Llanes-Tizoc, Mario D.
    • Earthquakes and Structures
    • /
    • 제11권2호
    • /
    • pp.217-243
    • /
    • 2016
  • The linear and nonlinear seismic responses of steel buildings with perimeter moment resisting frames and welded connections (WC) are estimated and compared with those of buildings with post-tensioned connections (PC). Two-dimensional (2D) and three-dimensional (3D) structural representations of the buildings as well as global and local response parameters are considered. The seismic responses and structural damage of steel buildings with PC may be significantly smaller than those of the buildings with typical WC. The reasons for this are that the PC buildings dissipate more hysteretic energy and attract smaller inertia forces. The response reduction is larger for global than for local response parameters. The reduction may significantly vary from one structural representation to another. One of the main reasons for this is that the energy dissipation characteristics are quite different for the 2D and 3D models. In addition, in the case of the 3D models, the contribution of each horizontal component to the axial load on an specific column may be in phase each other during some intervals of time, but for some others they may be out of phase. It is not possible to observe this effect on the 2D structural formulation. The implication of this is that 3D structural representation should be used while estimating the effect of the PC on the structural response. Thus, steel frames with post-tensioned bolted connections are a viable option in high seismicity areas due to the fact that brittle failure is prevented and also because of their reduced response and self-centering capacity.