• Title/Summary/Keyword: Nondestructive examination

Search Result 100, Processing Time 0.019 seconds

Study on Comparison of Korean Industrial Standard and ASME BPV Code for Radiographic Examination (방사선투과시험(放射線透過試驗)에 있어서 KS와 ASME Code의 비교(比較)에 관(關)한 연구(硏究))

  • Kim, Jin-Koo;Park, Byung-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.2
    • /
    • pp.20-29
    • /
    • 1985
  • There are two basic concepts in industrial radiographic examination; one is a radio-graphic sensitivity, and the other is a acceptance criteria. The comparison of these main points are studied for KS Standard and ASME Boiler and Pressure Vessel Code. From the results of the experiment, higher radiographic sensitivity is required in KS Standard when the thickness of material to be examined is less than 20mm in single wall technique. The acceptance criteria for linear type indications are described on same concept in two standards, whereas the acceptance criteria for rounded indications of KS Standard which mainly depends upon the object thickness are more severe than those of ASME BPV Code.

  • PDF

Development of Inspection Technology for the Depth Sizing on Surface Flaw of Pump Diffuser Vane (펌프 Diffuser Vane 표면결함 깊이측정 기법 개발)

  • Park, Cher-Young;Kim, Jin-Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.4 no.2
    • /
    • pp.46-49
    • /
    • 2008
  • NDE(Nondestructive examination) detects a flaw or discontinuity in materials. Flaws detected by the pre-service or in-service examinations shall be sized for the purpose of analysis and repair. A flaw that is initiated from the surface is difficult to determine its depth by NDE. The depth of the surface flaw can be measured using an ultrasonic diffracted wave. To find the optimum standard for ultrasonic parameter(For example, frequency & size of transducer), a mock-up test and simulation were established and studied. This inspection technology may show the depth sizing possibility of the flaw down to nearly two(2) mm.

  • PDF

TECHNIQUES FOR INTERGRANULAR CRACK FORMATION AND ASSESSMENT IN ALLOY 600 BASE AND ALLOY 182 WELD METALS

  • LEE, TAE HYUN;HWANG, IL SOON;KIM, HONG DEOK;KIM, JI HYUN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.102-114
    • /
    • 2015
  • Background: A technique developed to produce artificial intergranular stress corrosion cracks in structural components was applied to thick, forged alloy 600 base and alloy 182 weld metals for use in the qualification of nondestructive examination techniques for welded components in nuclear power plants. Methods: An externally controlled procedure was demonstrated to produce intergranular stress corrosion cracks that are comparable to service-induced cracks in both the base and weld metals. During the process of crack generation, an online direct current potential drop method using array probes was used to measure and monitor the sizes and shapes of the cracks. Results: A microstructural characterization of the produced cracks revealed realistic conformation of the crack faces unlike those in machined notches produced by an electrodischarge machine or simple fatigue loading using a universal testing machine. Conclusion: A comparison with a destructive metallographic examination showed that the characteristics, orientations, and sizes of the intergranular cracks produced in this study are highly reproducible.

A study on the Relationship between the Size of Defect and the Intensity of Eddy Current Signal in Heat Exchanging Tube made of STS 304. (Stainless강(鋼) 전열관(傳熱管)에 있어서 과전류(過電流) 신호강도(信號强度)와 결함(缺陷)크기와의 관계에 관한 연구(硏究))

  • Han, E.K.;Eom, H.S.;Park, I.G.;Choi, M.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.6 no.2
    • /
    • pp.7-16
    • /
    • 1987
  • Eddy Current Examination is expected as the effective technique for nondestructive inspection of steam generator and various kinds of heat exchanging tubes made of STS - 304. In Case of E. C. T, a study on the various factors which have an effect on coil impedance is very important to the sensitivity of defect detection and the ratio of signal to noise. Therefore, this study analyzed coil impedance by means of the variational principle, the minimized theory of energy functional and the application of Finite Element Method. Really by using E. C. T, the relationship between the size of defects and the intensity of Eddy Current Signals can be obtained. Signal intensity becomes maximum at certain frequency. This frequency is affected by the characteristics and the position of signal sources.

  • PDF

PSI/ISI Data Management System by using Personal Computer in Nuclear Power Plant (퍼스널 컴퓨터를 이용한 원자력발전소의 가동전.중 검사자료 관리 체제 전산화)

  • Song, S.J.;Sim, C.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.2
    • /
    • pp.67-72
    • /
    • 1989
  • In nuclear power plants, nondestructive examinations(NDE) plays an important role in ensuring the integrity and reliability operation. As the number of plants and operational time increased, manual handling of voluminous data associated with PSI/ISI(preservice/inservice inspection) could result in many errors or mistakes in writing the examination plan or other reports. Several new approaches to process the data have been attempted and DBMS(Data Base Management System) has been well known concept with a faster and more accurate data processing. This paper proposes an application program, called NDTSYS designed with DBMS in micro computer. The program could be used for a tool to add new records to a data base, change existing records, delete records and request reports with the data base. It would be helpful to the user who manage the PSI/ISI data with minimal time and effort.

  • PDF

플라즈마 절단 후 제작된 용접부의 기계적 특성

  • 신규인;김형곤;박재학;김성청
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1999.06a
    • /
    • pp.201-206
    • /
    • 1999
  • The influence of surface preparation methods after plasma cutting on the quality of welding zone is investigated. For comparison. three types of welded specimens are prepared by machining(YM), plasma cutting with light regrinding(WPG) and without regrinding(WP), by using three kinds of materials, carbon steel(S45C), stainless steel(Type304) and aluminum alloy (6061-T6). Nondestructive examination, hardness test, microstructure examination, and fracture toughness test are performed. The results show that there is no appreciable reduction in hardness or fracture toughness in WP specimens. But a little difference in heat affected gone size is observed.

  • PDF

Eddy Current Bobbin Probe Design for Steam Generator Tubes in NPPs (원전 증기발생기 전열관 와전류검사 보빈탐촉자 설계)

  • Nam, Min-Woo;Lee, Hee-Jong;Jee, Dong-Hyun;Jung, Jee-Hong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • The bobbin probe examination is basic and the important method among other ECT techniques for the steam generator tube integrity assesment that is practiced during each plant outage. The bobbin probe is one of the essential components which consist of the whole ECT examination system, and provides us a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of examination probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has enormous effects on examination results. In this study, An optimal differential bobbin probe is designed for the steam generator tube inspection in nuclear power plants(NPPs). Based on the test results for electrical and ECT signal characteristics, the prototype bobbin probe satisfies all the criteria.

Development of MFL Testing System for the Inspection of Storage Tank Floor (저장탱크 바닥면 검사를 위한 누설자속 탐상 시스템 개발)

  • Won, Soon-Ho;Cho, Kyung-Shik;Lee, Jong-O;Chang, Hong-Keun;Joo, Gwang-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.38-44
    • /
    • 2002
  • MFL method is a qualitative inspection tool and is a reliable, fast and economical NDT method. The application of MFL method to the inspection of storage tank floor plates has been shown to be a viable means. Examination of tank floors previously depended primarily upon ultrasonic test methods that required slow and painstaking application. Therefor most ultrasonic inspection of storage tank has been limited to spot testing only. Our NDE group have developed magnetic flux leakage system to overcome limitation of ultrasonic test. The developed system consists of magnetic yoke, array sensor, crawler and software. It is proved that the system is able to detect artificial flaw like 3.2mm diameter, 1.2mm depth in 6mm thick steel plate.

Preliminary Round Robin Test(RRT) for Program for the Inspection of Nickel Alloy Components(PINC) - Reactor Vessel Head Penetration (RVHP) -

  • Kim, Kyung-Cho;Kang, Sung-Sik;Shin, Ho-Sang;Song, Myung-Ho;Chung, Hae-Dong;Kim, Yong-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.256-263
    • /
    • 2009
  • After several PWSCCs were found in Bugey(France), Ringhals(Sweden), Tihange(Belgium), Oconee, Arkansas, Crystal Fever, Davis-Basse, VC Summer(U.S.A.), Thuruga(Japan), USNRC and PNNL started the research on PWSCC, that is, the PINC project. USNRC required KINS to participate in the PINC project in May 2005. KINS organized the Korean consortium at March 2006 and Pre-RRT for RVHP were performed for the preparation of PINC RRT. Through these preliminary RRT, Korea NDE teams can learn and develop the detection and sizing technique for RVHP dissimilar metal weld. These techniques are now being prepared in Korea and need to be utilized for the In-service inspection of the RVHP and BMI of Korea Nuclear Power Plants. PINC RRT mock-ups will be helpful to training.

A Study on the Flaw Evaluation in the Straddle Mount Type Low Pressure Turbine Disc Using Phased Array Ultrasonic Technique (위상 배열 초음파 기법을 이용한 Straddle Mount형 저압 터빈 디스크 결함 평가에 관한 연구)

  • Yang, Seung-Han;Yoon, Byung-Sik;Kim, Yong-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.231-238
    • /
    • 2006
  • Nondestructive examination for low pressure turbine disc in standard nuclear power plant using phased array technique was studied. For this purpose, disc mockups were made and notches were machined in the mockups. Detection and length sizing by different methods are compared. Depth of deep notches could be measured by using AATT(absolute arrival time technique) or RATT(relative arrival time technique) but shallow notches that must be detected in early stage couldn't be measured by these two methods. For this case, notch depth was estimated by using signal response angle range and preyed usefulness.