• 제목/요약/키워드: Noncontact sensor

검색결과 51건 처리시간 0.025초

자기스케일을 이용한 비접촉식 변위센서 (Noncontact displacement sensors using magnetic scale)

  • 이성필;서영진
    • 센서학회지
    • /
    • 제18권3호
    • /
    • pp.197-201
    • /
    • 2009
  • This paper studies on the noncontact displacement sensor system to detect the displacement of the cylinder rod. For an inexpensive and a simple process, magnetic scales are printed on the cylinder rod, and magnetized by the specially designed magnetizer that has an yoke through the alternation of N and S pole. Noncontact displacement sensor system consists of cylinder with magnetic scales, Hall sensor, linear guide, controller and display. The system can detect the displacement of moving cylinder with 5 cm/sec in the case of 1 mm magnetic scale. It shows a possibility of position detection of hydraulic cylinder and air cylinder.

투명판의 두께 측정용 비접촉식 광센서 개발 (A Noncontact Optical Sensor Development for Measuring the Thickness of Transparent Plates)

  • 유영기;오춘석;이서영
    • 전자공학회논문지SC
    • /
    • 제43권1호
    • /
    • pp.1-6
    • /
    • 2006
  • 경면물체의 형상과 두께를 측정하는데 있어 접촉식 센서가 가지고 있는 문제점을 해결하기 위해 홀로그램 레이저 다이오드와 자동 전력 제어를 이용하여 성능이 좋은 비접촉식 광센서를 개발하였다. 접촉식 센서에서는 센서 프로브가 측정 대상체와 계속해 접촉하므로 프로브의 마모로 인한 측정왜곡이 발생하게 된다. 이를 극복하기 위해 플라스틱렌즈와 CD 플레이어의 광학 픽업장치를 홀로그램 레이저로 구성하는 저가의 비접촉 센서를 제안한다. 비접촉식 광센서는 대상물체 쪽으로 움직이면서 포커스 에러 신호를 얻어 투명판의 형상과 두께를 측정할 수 있다. 센서 내부 온도를 ${\pm}0.1^{\circ}$ 제어한 상태에서 다수의 실험 측정을 수행하여 ${\pm}2{mu}m$의 측정 오차를 가지는 우수한 결과를 보이고 있다.

The applicability of noncontact sensors in the field of rehabilitation medicine

  • Yoo Jin Choo;Jun Sung Moon;Gun Woo Lee;Wook-Tae Park;Min Cheol Chang
    • Journal of Yeungnam Medical Science
    • /
    • 제41권1호
    • /
    • pp.53-55
    • /
    • 2024
  • A noncontact sensor field is an innovative device that can detect, measure, or monitor physical properties or conditions without direct physical contact with the subject or object under examination. These sensors use a variety of methods, including electromagnetic, optical, and acoustic technique, to collect information about the target without physical interaction. Noncontact sensors find wide-ranging applications in various fields such as manufacturing, robotics, automobiles, security, environmental monitoring, space industry, agriculture, and entertainment. In particular, they are used in the medical field, where they provide continuous monitoring of patient conditions and offer opportunities in rehabilitation medicine. This article introduces the potential of noncontact sensors in the field of rehabilitation medicine.

냉각된 원전 2차계통수의 온도측정을 위한 비접촉식 광섬유 온도센서의 개발 (Development of a Fiber-optic Noncontact Temperature Sensor for Measuring the Temperature of Cooled Secondary Water in a Nuclear Power Plant)

  • 유욱재;이봉수;박병기;조영호
    • 한국산학기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.1730-1734
    • /
    • 2010
  • 원전 2차계통수의 pH를 예측을 위해서는 샘플을 채취, 냉각시킨 후 pH를 측정하게 되는데 이 때 샘플의 온도는 pH를 변화시키는 중요한 요인이 된다. 본 연구에서는 할로겐화 은 광섬유를 이용하여 비접촉식 온도센서를 개발하였고, 열전쌍열을 이용하여 열원으로부터 방출되는 적외선을 측정하였다. 열원과 광섬유 끝단 사이의 거리 및 각도 변화에 따른 광섬유 온도센서의 출력신호를 분석하였으며, 광섬유 온도센서로 측정한 온도범위는 $25{\sim}60^{\circ}C$이다. 본 연구결과를 기초로 원전 2차계통수 pH 샘플의 온도를 측정하기 위해 할로겐화 은 광섬유를 이용한 비접촉식 온도센서의 개발이 가능할 것으로 기대된다.

Silver Halide 광섬유를 이용한 의료용 비접촉식 온도 센서 개발 (Development of Noncontact Temperature Sensor Using Silver Halide Optical Fiber for Medical Usages)

  • 유욱재;조동현;장경원;정순철;탁계래;이봉수
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.337-342
    • /
    • 2006
  • We have developed a noncontact temperature sensor using a silver halide optical fiber. The infrared collimator and focus head are connected both ends of a silver halide optical fiber with SMA connectors and used to collimate radiations of a heat source and to focus them to infrared sensors such as a pyroelectric sensor and a thermopile sensor, respectively. The relation ships between the temperatures of a heat source and the output signals of the infrared sensors are determined to measure the surface temperature of a heat source. The measurable temperature range is from 25 to $60^{\circ}C$. It is expected that a noncontact temperature sensor using a silver halide optical fiber can be developed for medical usages such as temperature monitoring during hyperthermia, cryosurgery, laser surgery and diagnostic procedure based on the results of this study.

평판 투명 물체의 형상측정을 위한 비접촉식 광센서 개발 (Development of a noncontact optical sensor for measuring the shape of transparent plates)

  • 윤상필;유영기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.214-214
    • /
    • 2000
  • This paper deals with the non contact optical sensor to measure the shape of transparent plates such as glass panel of LCD(Liquid Crystal Display). The conventional methods to obtain the shape or thickness of a transparent plates are contact type sensor such as LVOT(Linear Variable Differential Transformer). Due to the contact between the tip of the sensor and the surface of objects, the tip is abraded. In addition, the high temperature glass casting makes the size of sensor body changed. These reasons makes the sensor degraded. In this paper, to overcome these problem, we proposed a low cost noncontact optical sensor this is composed of the Hologram laser unit of a CD-Pickup and a plastic lens. To evaluate the performance of the proposed optical sensor, a series of experiments were performed for various measurement condition. Based upon observation of the experimental result, the developed sensor shows good result for measuring the shape of transparent plates.

  • PDF

Study of Capacitive Tilt Sensor with Metallic Ball

  • Lee, Chang Hwa;Lee, Seung Seob
    • ETRI Journal
    • /
    • 제36권3호
    • /
    • pp.361-366
    • /
    • 2014
  • In this paper, a new, simple capacitive tilt sensor with a metallic ball is proposed. The proposed tilt sensor has only two electrodes and a metallic ball, and this design assists in managing the inherent contact problem in measuring tilt angles. Capacitive sensing, compared with other types of tilt sensor, has many advantages such as simplicity, noncontact measurement, long-throw linear displacement, and sub-micron plate spacing. Its design and fabrication process are significantly simpler than previous types of tilt sensors. The dimensions of the prototype tilt sensor are $20mm{\times}20mm$, and the diameter of the polystyrene tube is 5 mm with a tube thickness of 0.15 mm. An analytical study of the prototype capacitive tilt sensor was undertaken, and the experimental results demonstrate the relationship between the tilt angles and measured capacitances compared with the analytical study.

적외선 투과 광섬유를 이용한 비접촉식 온도 센서 개발을 위한 기초 연구 (Feasibility study on the development of noncontact temperature sensor using infrared optical fiber)

  • 유욱재;조동현;정순철;탁계래;전재훈;이봉수;손상희;조승현
    • 센서학회지
    • /
    • 제15권3호
    • /
    • pp.179-185
    • /
    • 2006
  • We have developed a noncontact temperature sensor using a silver halides infrared optical fiber. An infrared radiation from a heat source is transferred by a silver halides infrared optical fiber and measured by infrared sensors such as a thermopile and a thermal optical power-meter. The relationships between the temperature of a heat source and the output voltage of the thermopile and the optical power of a thermal optical power-meter are determined. The measurable temperature range using a thermopile and a thermal optical power-meter are from 100 to $750^{\circ}C$ and from 30 to $750^{\circ}C$ respectively. It is expected that a noncontact temperature sensor using infrared optical fiber can be developed for medical and industrial usages based on the results of this study.

MR 센서와 PIC를 이용한 비접촉식 정밀 유량계 개발에 관한 연구 (A Study on Development of a Noncontact Precision Flow-meter Using MR Sensor and PIC)

  • 이승희;이민철;고석조;장용석;최문호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1063-1066
    • /
    • 2003
  • A flow-meter and its measurement controller was developed for a hydraulic system. This study, for development of positive displacement flow-meter, consist of PIC(Peripheral Interface Controller) controller with MR(Magneto-resistive) sensors. This flow-meter is used valve position indicator for valve control system by hydraulic. The MR sensors are used for the rotation of OVAL gear that detecting device. In the ship environments, consideration that necessary explosive proof. Thus electro device or electro flow-meter needs explosion design for electric circuit. We designed noncontact type flow-meter and evaluated the safety and measuring abilities.

  • PDF

회전속도와 탄성파를 동시에 측정하는 비접촉 자왜형 센서의 자기적 특성 분석 (Analysis of Magnetic Characteristics for a Noncontact Magnetostrictive Sensor Simultaneously Measuring Rotational Speed and Force)

  • 이호철
    • 한국소음진동공학회논문집
    • /
    • 제19권4호
    • /
    • pp.418-424
    • /
    • 2009
  • This work is the attempt to give qualitative explanations to complex magnetic phenomena which are observed in the previously proposed magnetostrictive sensor capable of ultrasonic waves and rotational speed measurement. The law of approach is adopted as analysis tool in order to account for some extraordinary output patterns and proved to be effective. The distance between the anhysteretic curve current magnetic state and the variation of anhysteretic curve by stress mainly determine the sensor output shapes and their uniqueness. It is also experimentally verified that the precisely determined bias magnetic field strength can not only remove the unusual output parts but also maximize its sensitivity.