• Title/Summary/Keyword: Noncontact sensor

Search Result 51, Processing Time 0.024 seconds

Noncontact displacement sensors using magnetic scale (자기스케일을 이용한 비접촉식 변위센서)

  • Lee, Sung-Pil;Seo, Young-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.197-201
    • /
    • 2009
  • This paper studies on the noncontact displacement sensor system to detect the displacement of the cylinder rod. For an inexpensive and a simple process, magnetic scales are printed on the cylinder rod, and magnetized by the specially designed magnetizer that has an yoke through the alternation of N and S pole. Noncontact displacement sensor system consists of cylinder with magnetic scales, Hall sensor, linear guide, controller and display. The system can detect the displacement of moving cylinder with 5 cm/sec in the case of 1 mm magnetic scale. It shows a possibility of position detection of hydraulic cylinder and air cylinder.

A Noncontact Optical Sensor Development for Measuring the Thickness of Transparent Plates (투명판의 두께 측정용 비접촉식 광센서 개발)

  • Ryu, Young-Kee;Oh, Choonsuk;Lee, Seoyoung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.1 s.307
    • /
    • pp.1-6
    • /
    • 2006
  • The noncontact optical sensor using the hologram laser and automatic power controller is developed to measure a thickness of transparent objects and achieve excellent performance. Due to the contact between the tip of the sensor and the surface of objects, the tip is abraded. In addition the casting glass under high temperature results in extending the size of sensor body. The accuracy of the sensor is degraded due to these reasons. In this paper, to overcome these problems, we proposed a low cost non-contact optical sensor that is composed of a hologram laser unit used for optical pickup of CD player and a plastic lens. Therefore the problems caused by the contact sensor are solved by using the noncontact sensor. The noncontact sensor has to move toward the objects and obtain the focus error signal to measure a position of transparent objects. While the internal temperature of the sensor is controlled under ${\pm}0.1^{\circ}$, many trials shows ${\pm}2{\mu}m$ measurement error as excellent performance.

The applicability of noncontact sensors in the field of rehabilitation medicine

  • Yoo Jin Choo;Jun Sung Moon;Gun Woo Lee;Wook-Tae Park;Min Cheol Chang
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.1
    • /
    • pp.53-55
    • /
    • 2024
  • A noncontact sensor field is an innovative device that can detect, measure, or monitor physical properties or conditions without direct physical contact with the subject or object under examination. These sensors use a variety of methods, including electromagnetic, optical, and acoustic technique, to collect information about the target without physical interaction. Noncontact sensors find wide-ranging applications in various fields such as manufacturing, robotics, automobiles, security, environmental monitoring, space industry, agriculture, and entertainment. In particular, they are used in the medical field, where they provide continuous monitoring of patient conditions and offer opportunities in rehabilitation medicine. This article introduces the potential of noncontact sensors in the field of rehabilitation medicine.

Development of a Fiber-optic Noncontact Temperature Sensor for Measuring the Temperature of Cooled Secondary Water in a Nuclear Power Plant (냉각된 원전 2차계통수의 온도측정을 위한 비접촉식 광섬유 온도센서의 개발)

  • Yoo, Wook-Jae;Lee, Bong-Soo;Park, Byung-Gi;Cho, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1730-1734
    • /
    • 2010
  • Generally, a pH value of secondary water in a nuclear power plant should be estimated after sampling and cooling down. In this process, the measurement of temperature is very important because a pH value is varied according to the temperature of secondary water. In this study, a noncontact fiber-optic temperature sensor using a silver halide optical fiber is fabricated to measure the temperature of cooled secondary water. And we have measured an infrared radiation, which is transferred by a silver halide optical fiber from a heat source, using a thermopile sensor. The relationships between the temperature of a heat source and the output voltage of the fiber-optic temperature sensor according to the change of distance and angle are determined. The measurable temperature range of the fiber-optic temperature sensor is from 25 to $60^{\circ}C$. Based on the results of this study, a noncontact temperature sensor using a silver halide optical fiber can be developed for the temperature measurement of the pH sample in the secondary water system.

Development of Noncontact Temperature Sensor Using Silver Halide Optical Fiber for Medical Usages (Silver Halide 광섬유를 이용한 의료용 비접촉식 온도 센서 개발)

  • Yoo, Wook-Jae;Cho, Dong-Hyun;Jang, Kyoung-Won;Chung, Soon-Cheol;Tack, Gye-Rae;Lee, Bong-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.337-342
    • /
    • 2006
  • We have developed a noncontact temperature sensor using a silver halide optical fiber. The infrared collimator and focus head are connected both ends of a silver halide optical fiber with SMA connectors and used to collimate radiations of a heat source and to focus them to infrared sensors such as a pyroelectric sensor and a thermopile sensor, respectively. The relation ships between the temperatures of a heat source and the output signals of the infrared sensors are determined to measure the surface temperature of a heat source. The measurable temperature range is from 25 to $60^{\circ}C$. It is expected that a noncontact temperature sensor using a silver halide optical fiber can be developed for medical usages such as temperature monitoring during hyperthermia, cryosurgery, laser surgery and diagnostic procedure based on the results of this study.

Development of a noncontact optical sensor for measuring the shape of transparent plates (평판 투명 물체의 형상측정을 위한 비접촉식 광센서 개발)

  • 윤상필;유영기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.214-214
    • /
    • 2000
  • This paper deals with the non contact optical sensor to measure the shape of transparent plates such as glass panel of LCD(Liquid Crystal Display). The conventional methods to obtain the shape or thickness of a transparent plates are contact type sensor such as LVOT(Linear Variable Differential Transformer). Due to the contact between the tip of the sensor and the surface of objects, the tip is abraded. In addition, the high temperature glass casting makes the size of sensor body changed. These reasons makes the sensor degraded. In this paper, to overcome these problem, we proposed a low cost noncontact optical sensor this is composed of the Hologram laser unit of a CD-Pickup and a plastic lens. To evaluate the performance of the proposed optical sensor, a series of experiments were performed for various measurement condition. Based upon observation of the experimental result, the developed sensor shows good result for measuring the shape of transparent plates.

  • PDF

Study of Capacitive Tilt Sensor with Metallic Ball

  • Lee, Chang Hwa;Lee, Seung Seob
    • ETRI Journal
    • /
    • v.36 no.3
    • /
    • pp.361-366
    • /
    • 2014
  • In this paper, a new, simple capacitive tilt sensor with a metallic ball is proposed. The proposed tilt sensor has only two electrodes and a metallic ball, and this design assists in managing the inherent contact problem in measuring tilt angles. Capacitive sensing, compared with other types of tilt sensor, has many advantages such as simplicity, noncontact measurement, long-throw linear displacement, and sub-micron plate spacing. Its design and fabrication process are significantly simpler than previous types of tilt sensors. The dimensions of the prototype tilt sensor are $20mm{\times}20mm$, and the diameter of the polystyrene tube is 5 mm with a tube thickness of 0.15 mm. An analytical study of the prototype capacitive tilt sensor was undertaken, and the experimental results demonstrate the relationship between the tilt angles and measured capacitances compared with the analytical study.

Feasibility study on the development of noncontact temperature sensor using infrared optical fiber (적외선 투과 광섬유를 이용한 비접촉식 온도 센서 개발을 위한 기초 연구)

  • Yoo, Wook-Jae;Cho, Dong-Hyun;Chung, Soon-Cheol;Tack, Gye-Rae;Jun, Jae-Hoon;Lee, Bong-Soo;Son, Sang-Hee;Cho, Seung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.179-185
    • /
    • 2006
  • We have developed a noncontact temperature sensor using a silver halides infrared optical fiber. An infrared radiation from a heat source is transferred by a silver halides infrared optical fiber and measured by infrared sensors such as a thermopile and a thermal optical power-meter. The relationships between the temperature of a heat source and the output voltage of the thermopile and the optical power of a thermal optical power-meter are determined. The measurable temperature range using a thermopile and a thermal optical power-meter are from 100 to $750^{\circ}C$ and from 30 to $750^{\circ}C$ respectively. It is expected that a noncontact temperature sensor using infrared optical fiber can be developed for medical and industrial usages based on the results of this study.

A Study on Development of a Noncontact Precision Flow-meter Using MR Sensor and PIC (MR 센서와 PIC를 이용한 비접촉식 정밀 유량계 개발에 관한 연구)

  • 이승희;이민철;고석조;장용석;최문호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1063-1066
    • /
    • 2003
  • A flow-meter and its measurement controller was developed for a hydraulic system. This study, for development of positive displacement flow-meter, consist of PIC(Peripheral Interface Controller) controller with MR(Magneto-resistive) sensors. This flow-meter is used valve position indicator for valve control system by hydraulic. The MR sensors are used for the rotation of OVAL gear that detecting device. In the ship environments, consideration that necessary explosive proof. Thus electro device or electro flow-meter needs explosion design for electric circuit. We designed noncontact type flow-meter and evaluated the safety and measuring abilities.

  • PDF

Analysis of Magnetic Characteristics for a Noncontact Magnetostrictive Sensor Simultaneously Measuring Rotational Speed and Force (회전속도와 탄성파를 동시에 측정하는 비접촉 자왜형 센서의 자기적 특성 분석)

  • Lee, Ho-Cheol
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.4
    • /
    • pp.418-424
    • /
    • 2009
  • This work is the attempt to give qualitative explanations to complex magnetic phenomena which are observed in the previously proposed magnetostrictive sensor capable of ultrasonic waves and rotational speed measurement. The law of approach is adopted as analysis tool in order to account for some extraordinary output patterns and proved to be effective. The distance between the anhysteretic curve current magnetic state and the variation of anhysteretic curve by stress mainly determine the sensor output shapes and their uniqueness. It is also experimentally verified that the precisely determined bias magnetic field strength can not only remove the unusual output parts but also maximize its sensitivity.