• Title/Summary/Keyword: Nonabsorbable suture

Search Result 17, Processing Time 0.027 seconds

Inframammary Fold Creation in Breast Reconstruction (유방재건시 유방하 주름의 생성)

  • Lee, Hae Min;Ahn, Hee Chang;Choi, Seung Suk;Jo, Dong In;Byun, Tae Ho
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.231-236
    • /
    • 2005
  • Nowadays breast reconstruction with autologous tissues after radical mastectomy is commonly performed, and a natural inframammary fold in the reconstructed breast is considered to be an essential aspect of symmetrical breast shape and location. Total of 104 patients underwent breast reconstruction with free TRAM flap and formation of inframammary fold with free TRAM breast reconstruction was done in 79 patients. No suture fixation for inframammary fold were done in 19 patients. 27 patients(24.0%) were made of inframammary fold with absorbable suture, 52 patients (50.0%) underwent inframammary fold creation with nonabsorbable suture. There were 4 cases(16.0%) of displacement of reconstructed breast and 2 cases(8.0%) of partial disruption of inframammary fold in the group of no suture. There were 2 cases(7.4%) of displacement of reconstructed breast and 3 cases(11.1%) of partial disruption of inframmamary fold in the fixed group with absorbable suture. There was only 1 case(1.9%) of partial disruption of inframammary fold fixed with nonabsorbable suture group. Therefore, we could speculate that the reinforcement of ligamentous structure for making the definite inframammary fold is necessary, and the area of the inframammary fold should not be undermined in immediate breast reconstruction as much as possible in order to preserve the zone of adherence. If the fold is disrupted during the mastectomy, it should be re-created with the non-absorbable sutures. Nonabsorbable suture fixation seemed to be more stable than absorbable suture. Preoperative marking and design are very important to make the symmetrical shape and location of inframammary fold in both of immediate and delayed reconstruction of breasts.

The Fate of Nonabsorbable Sutures in Arthroscopic Inside-Out Meniscus Repair - A Case Report - (관절경적 Inside-Out 반월상 연골 봉합술에서 비흡수성 봉합사의 운명 - 1예 보고 -)

  • Ahn, Jin-Hwan;Lee, Dong-Hoon;Chang, Moon-Jong;Seo, Hee-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.54-58
    • /
    • 2007
  • Either absorbable or nonabsorbable sutures can be used in meniscal repair. Some surgeons prefer nonabsorbable sutures because they believe that nonabsorbable sutures improve meniscal healing as compared with absorbable sutures. But, permanent existence of sutures in the lesion could make problems. We report a case of Inside-Out meniscus repair that nonabsorbable sutures came out of the joint capsule tearing the substance of the meniscus.

  • PDF

Surgical Treatment of Achilles Tendon Rupture with Absorbable Suture Materials Only (흡수성 봉합사만를 이용한 아킬레스건 파열의 수술적 치료)

  • Bae, Su-Young;Park, Jae Gu;Jung, Eui Yub
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.3
    • /
    • pp.196-202
    • /
    • 2013
  • Purpose: To report the clinical results from using absorbable suture materials instead of nonabsorbable materials which have been used more commonly to repair Achilles tendon. Materials and Methods: We retrospectively reviewed 21 cases of acute Achilles tendon rupture, treated surgically from 2004 to 2011. Mean follow-up period is 6 months. We repaired Achilles tendon using size 1 Vicryl (Polyglactin 910, Ethicon) for core suture and size 3-0 Vicryl for epitendinous suture. At three months after surgery, we evaluated clinical results with single heel raise height by centimeters, differences of calf circumference and passive range of motion of ankle joint, compared to contralateral side. Also we recorded clinical results with subjective satisfaction grades. Results: At three months after surgery, 20 of 21 patients were able to perform single heel raise over 5 cm in height. Calf circumference differences were less than 1 cm in 12 cases, between 1 cm to 3 cm in 5 cases, more than 3 cm in 4 cases. There was no difference in range of passive motion in 19 cases. All patients satisfied with daily activity except 2 cases with mild discomfort. There was no complication such as rerupture, elongation or infection. Conclusion: We experienced excellent clinical results from repairing Achilles tendon with using absorbable suture materials in terms of functional outcomes and patient's satisfaction without any complication. So we may consider using absorbable suture materials instead of nonabsorbable materials to repair Achilles tendon.

A Case of Rentention Sutures of Vaginal Prolapse in a Dairy Cow (유우의 질탈교정술의 일예)

  • Cho Myoung-Rae
    • Journal of Veterinary Clinics
    • /
    • v.9 no.1
    • /
    • pp.311-316
    • /
    • 1992
  • Four retention sutures were used to correct the vaginal prolapse in a dairy cow. The methods used were two modified Caslick operation of vulva using absorbable(catgut chromic) and nonabsorbable(supramid) materials, and a modified mattress closure and a modified Buhner method of vulva using trocar and wire insulated by vinyl. The lasting periods for retention of bovine vaginal prolapse by the suture methods described above, were 12 days, 49 days, 39 days and 62 days respectively.

  • PDF

A Case Report of Traumatic Tracheoesophageal Fistula (외상성 기관식도루 -수술체험 1례-)

  • 최승호
    • Journal of Chest Surgery
    • /
    • v.27 no.10
    • /
    • pp.888-892
    • /
    • 1994
  • Acquired, traumatic tracheoesophageal fistula [TEF] is rare and difficult problem to manage. This 55 years old man met with a roller accident of a tractor. During accident, he received a penetrating injury on the left upper sternal border. At local clinic, he received closed thoracotomy drainage [CTD]for relief of pneumothorax[left]. Three days after CTD, he complained abdominal pain and hematemesis. The endoscopy revealed large ulcer at the stomach, so he received subtotal gastrectomy. On 10th day post subtotal gastrectomy, he developed aspiration and coughing from a TEF. The esophagogram showed large TEF at the mid-trachea level. So he transfered to our hospital for operation. This patient was operated on for late TEF three weeks after injury. We have used absorble 4-0 Vicryl sutures to repair trachea. We repair all esophageal injuries with two layers of nonabsorbable silk suture. Where suture line on the esophagus, the strap muscle was interposed for reinforcement. And for feeding, the feeding jejunostomy was performed. Postoperatively the osteomyelitis of the manubrium site was developed, so on the 30th postoperative day, an ostectomy of manubrium, both clavicle and fight 1st, 2nd ribs, and the pectoralis major musculo-cutaneous flap coverage were performed.

  • PDF

Reconstruction of Coracoclavicular Ligament with Semitendinosus Tendon Graft - Technical Note - (반건양근을 이용한 오구쇄골 인대의 재건술(수술 수기))

  • Choi Nam-Hong;Bae Sang-Wook;You Soo-Geun
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.138-142
    • /
    • 1999
  • Coracoclavicular ligament is main restraint to superior instability of the distal clavicle. Coracoacromial ligament, extensor tendon of toe, palmaris longus tendon, and Dacron tape have been used to reconstruct coracoclavicular ligament. We used semitedinosus tendon to reconstruct coracoclavicular ligament. The semitendinosus tendon was harvested as a usual fashion. After the distal clavicle and coracoid process were exposed, a hole of six millimeter diameter was made on the center of whole thickness of the distal clavicle. A malleolar screw was fixed from distal clavicle to coracoid process to maintain the reduced position of the acromioclavicular joint. The leading suture of tendon graft was passed through the hole of the distal clavicle and looped under the coracoid process. After leading portion of ten­don graft was looped over the clavicle, sutures were made between each end of the tendon graft with nonabsorbable suture materials.

  • PDF

Results of Arthroscopic inside to Out Repair of Meniscus Tear (반월상연골 파열에 대한 관절경적 inside to out 봉합술의 결과)

  • Kim, Bo-Hyun;Hwang, In-Sung;Yun, Tae-Bong;Byun, Jae-Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Purpose: This study examined clinical cure and patients' satisfaction degrees by factors influencing surgical operation results, after arthroscopic inside to out repair as a nonabsorbable suture material, in case of meniscal rupture. Materials and Methods: Materials were 110 cases of 95 patients who could make paces for over 12 months from August 1999 to June 2002. Results were evaluated by clinical cure and subjective satisfaction degrees. This study, concerning those results, analyzed age, term from taking pictures to taking surgical operation, rupture section, rupture length, rupture types, lesion of articular-cartilage, and effects of anterior cruciate ligament operation accompanied. Results: 84 cases(76%) were clinically cured, 98 cases(89%) were subjectively satisfied. In case of accompanying anterior cruciate ligament rupture, and in case that rupture length was below 2 cm, rates of clinical cure and patients subjective satisfaction were significantly high. In case of complex or degenerative rupture, patients satisfaction rates were higher when comparing with clinical cure rates. Conclusion: Various sutures are possible as well as available in case of arthroscopic meniscal inside to out repair using nonabsorbable suture material. It can be concluded that patients age is not absolte consideration in determining the suture of meniscus. In cases of complex rupture, degenerative rupture, ruptures companied by joint-cartilage injuries, considerate consideratin need be paid to choose patients and operations.

  • PDF

Tension Band Sutures Using a Washer for a Proximal Humerus Fracture

  • Kim, Kyung-Cheon;Rhee, Kwang-Jin;Shin, Hyun-Dae;Byun, Ki-Yong;Yang, Jae-Hoon;Kim, Dong-Kyu;Kim, Joung-Hun
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2009.03a
    • /
    • pp.161-161
    • /
    • 2009
  • To prevent distraction and varus deformity between the humeral head and shaft, tension band sutures placed between the head of the interlocking screw and the rotator cuff, and we recommend using nonabsorbable sutures. We describe our simple procedure to overcome these difficulties in tension band suturing after reducing a proximal humerus fracture to maintain the reduction.

  • PDF

The Usefulness of Allogenous Costal Cartilage Graft for Correction of Short Nose and Tip Plasty (짧은 코 교정술과 비첨성형술에 있어서 동종늑연골 (Tutoplast®) 이식의 유용성)

  • Choi, Sung Won;Won, Dong Chul;Lim, Young Kook;Hong, Yong Taek;Kim, Hoon Nam
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.120-126
    • /
    • 2009
  • Purpose: Autogenous cartilage is generally first choice in rhinoplasty because of its biocompatibility and resistance to infection. On the other hand, allogeneous cartilage graft might preferred over an autogenous graft to avoid additional donor site scars, morbidity and lengthened operating time. Allogenous costal cartilage ($Tutoplast^{(R)}$) not only have the advantage of averting donor site morbidity but also are resistant to infection, resembling autogenous cartilage graft. We report here a technique for rhinoplasty by using allogenous costal cartilage graft. Methods: Through open rhinoplastic approach, alar cartilage is released from upper lateral cartilage and relocated caudally. After relocation of alar cartilage, allogenous costal cartilage is immobilized by nonabsorbable suture material at caudal aspect of septal cartilage. Caudal end of allogenous costal cartilage is sutured between medial crura of alar cartilage. Tip projection is improved by using interdormal suture, transdormal suture and shield-shape cartilage graft which is harvested from concha Results: No significant resorption and infection was detected in any of patients. Aesthetic and functional results were satisfactory. Conclusion: The low incidence of major complication and versatility of allogeneous costal cartilage graft make safe and reliable source of cartilage graft in rhinoplasty.

Flexor Tenorrhaphy Using Absorbable Suture Materials

  • Kang, Hyung Joo;Lee, Dong Chul;Kim, Jin Soo;Ki, Sae Hwi;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.397-403
    • /
    • 2012
  • Background Nonabsorbable sutures are favorable for repairing flexor tendons. However, absorbable sutures have performed favorably in an animal model. Methods Two-strand sutures using the interlocking modified Kessler method with polydioxanone absorbable sutures 4-0 were used to repair completely ruptured flexor tendons in 55 fingers from 41 consecutive patients. The medical records of average 42 follow up weeks were analyzed retrospectively. The data analyzed using the chi-squared test, and Fisher's exact test was used for postoperative complications. The results were compared with those of other studies. Results Among the index, middle, ring, and little fingers were injured in 9, 17, 16, and 13 fingers, respectively. The injury levels varied from zone 1 to 5. Of the 55 digits in our study, there were 26 (47%) isolated flexor digitorum profundus (FDP) injuries and 29 (53%) combined FDP and with flexor digitorum superficialis injuries. Pulley repair was also conducted. Concomitant injuries of blood vessels and nerves were found in 17 patients (23 fingers); nerve injuries occurred in 5 patients (10 fingers). Two patients had ruptures (3.6%), and one patient had two adhesions (3.6%). Using the original Strickland criteria, all the patients were assessed to be excellent or good. Also, fibrosis and long-term foreign body tissue reactions such as stitch granuloma were less likely occurred in our study. Compared to the Cullen's report that used nonabsorbable sutures, there was no significant difference in the rupture or adhesion rates. Conclusions Therefore, this study suggests that appropriate absorbable core sutures can be used safely for flexor tendon repairs.