• Title/Summary/Keyword: Non-uniform luminance

Search Result 17, Processing Time 0.036 seconds

Perception of Glare Source According to the Luminance Difference on a Window Plane (창면의 상하부 휘도차에 따른 글레어 광원의 인식변화)

  • Kim, Wonwoo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.17-22
    • /
    • 2007
  • The existing discomfort glare models are based on research that was conducted exclusively with uniform luminance sources. It is impossible to apply the models to windows of non-uniform luminance. For evaluating discomfort glare from windows, the method selecting glare source on a window plane is necessary. This study was carried outto propose a practical method to choose glare source from anon-uniform window plane. In the experiment, the perception of glare source according to the luminance difference is examined using a simulated windowof non-uniform luminance. The surface of the window is divided into two or three parts, and different luminance is setting on each surface. The observers were asked to decide whether the lower part of the window can be perceived as a glare source or not. The result shows that the lower part is perceived as a glare source when the lower part has over 37% of the luminance of the upper part of the window divided into two parts, and when it has over 51% of the luminance of the upper part of the window divided into three parts. the results may be applicable to select the glare source in awindow.

Effect of Luminance Difference on Discomfort Glare from a Large Glare Source with Non-uniform Luminance (대광원의 상하부 휘도차가 불쾌글레어 평가에 미치는 영향)

  • Kim, Wonwoo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.29-34
    • /
    • 2007
  • Discomfort glare from windows is an important issue in window and daylighting design. This study aims to investigate the effect of luminance difference between the lower and the upper part of a large glare source. Experiments were conducted using a luminous body divided into two parts, the upper part and the lower part. The degree of discomfort glare from the luminous body was examined. The result shows that the part with lower luminance is perceived as a glare source when the part has higher luminance then the background luminance. The degree of discomfort glare was estimated for the experimental conditions, and compared to the observations. The estimation was made using two methods: one summed the glare sensation for each section, and the other used the average luminance of the whole luminous body. The result of the comparison shows that the method using the average luminance has approximate values to the observations. Consequently, the use of the average luminance was proposed for evaluation of discomfort glare from non-uniform large glare sources.

An Experiment of Discomfort Glare from Non-uniform Glare Source (불균일한 휘도를 갖는 창면의 불쾌글레어 평가실험)

  • Shin, Ju-Young;Kim, Jeong-Tai;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • Impact of daylighting on the visual environment can improve occupant's well-being by providing visual comfort. Also, daylighting can save energy. However, glare from window can be a direct hazard to vision and can cause serious discomfort. Selecting glare source on a window plane is very important for evaluating discomfort glare from windows. But former glare indices can not identify the range of the glare source properly. In this study, difference in glare sensation with uniform and non-uniform glare sources are evaluated to identify the range of the glare source. The glare source was assumed as $120{\times}120[cm]$ window model. The window was divided into three parts with different luminance values. The experiment was conducted under 1[m], 1.5[m], 3[m] distance from the glare source. Two results were obtained from the experiments. First, the degree of discomfort glare increased as average window luminance increased. Second, the middle and lower part of the window plane can affect evaluation of discomfort glare as well as the upper part of the window plan. These results can be used for selecting the glare source in a window with non-uniform luminance.

Development of LED TV Panel Brightness Uniformity Correction System (LED TV 패널 밝기 균일화 보정 시스템 개발)

  • Park, Je Sung;Lee, Won Woo;Jian, Zhangye;Joo, Hyonam;Kim, Joon Seek
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.5
    • /
    • pp.382-388
    • /
    • 2016
  • When Flat Panel Display (FPD) is made with backlight module, such as LED TV, it inherently suffers from the non-uniform backlight luminance problem that results in un-even brightness distribution throughout the TV screen. If the luminance of each pixel location of a TV screen as a function of the driving voltage can be measured, it can be used to compensate the non-uniformity of the backlight module. We use a carefully calibrated imaging system to take pictures of a TV screen at different levels of brightness and generate the compensation functions for the driving circuitry to correct the luminance level at each pixel location. Making use of the fact that the luminance of the screen is normally brightest at around the center of the screen and gradually decreases toward the border of the screen, the luminance of the whole TV screen is approximated by a mathematical function of the pixel locations. The parameters of the function are computed in the least square sense by the values of both the pixel luminance sent from the driving circuit and the grayscale value measured from the image taken by the imaging system. To justify the correction system, a simple second order polynomial function is used to approximate the luminance across the screen. When the driving circuit voltage is corrected according to the measured function, the variance of the screen luminance is reduced to one tenth of the one measured from the un-corrected TV screen.

Simulation Study of Injection-Molded Light Guide Plates for Improving Luminance Uniformity Based on the Measured Replication Quality of Micro-Patterns for LED TV Backlight

  • Joo, Byung-Yun;Ko, Jae-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.159-164
    • /
    • 2015
  • In the injection-molded light guide plate the replication quality, i.e. the reproduction accuracy, of micro-patterns should be high and uniform over the entire surface area. However technical difficulty in meeting the necessary replication quality arises as the plate size becomes large for TV applications. We propose a simulation technique to optimize the distribution of micro-patterns on a 55-inch injection molded light guide plate considering non-ideal replication quality of micro-patterns. The luminance uniformity could be improved by more than 16% by optimizing the pattern distribution in spite of the same replication quality.

The study of a revision UGR for non-uniform luminance source (불균일 휘도 장원의 UGR 보정에 관한 연구)

  • Jung, Seung-Gyun;Cho, Yong-Ik;Oh, Suk-Sik;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.137-140
    • /
    • 2008
  • 실내조명으로서의 LED는 휘도의 분포특성이 기존의 조명기구와는 판이하게 다르며, 이에 따라 불쾌감을 느끼는 정도에서도 변화가 일어날 수 있다. 본 연구에서는 현재 가장 일반적으로 사용되어지는 글레어 평가지수인 UGR을 간단히 보정하여 LED 조명기구에 대한 값으로 사용할 수 있도록 주관평가 실험을 통해 보정식을 산출해내고 LED 조명기구별 증가계수 k를 구하였다.

  • PDF

Study of the Optical System Design of a Reflective LED Stand to Reduce Glare (눈부심 감소를 위한 반사형 LED 스탠드 광학계 설계에 관한 연구)

  • Kong, Mi-Seon;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.334-343
    • /
    • 2020
  • In this paper, a study of the design of a lighting optical system to form indirect light was conducted, to reduce the glare caused by the hot spot of the LED. In the case of using an LED for indoor lighting, glare is caused because of the high luminance and non-uniform luminance distribution. In particular, LED stands are located close to the user's eyes and are used for a long time, so research to reduce glare is essential. Therefore, in this paper an optical system structural study and the design of an LED stand for glare reduction were conducted. Afterward, the luminance analysis and comparison to an existing LED stand product confirmed that the reflective LED stand proposed in this paper had better performance in terms of glare.

Studies on Printing Inks Containing Poly[2-methoxy-5-(2-ethylhexyl-oxyl)-1,4-phenylenevinylene] as an Emissive Material for the Fabrication of Polymer Light-Emitting Diodes by Inkjet Printing

  • Kwon, Jae-Taek;Eom, Seung-Hun;Moon, Byung-Seuk;Shin, Jin-Koog;Kim, Kyu-Sik;Lee, Soo-Hyoung;Lee, Youn-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.464-468
    • /
    • 2012
  • Three solvent systems, chlorobenzene (ink 1), chlorobenzene/o-dichlorobenzene (ink 2) and chlorobenzene/tetrahydronaphthalene (ink 3), were compared as printable inks for the fabrication of polymer light-emitting diodes (PLEDs) using poly[2-methoxy-5-(2-ethylhexyl-oxyl)-1,4-phenylenevinylene (MEH-PPV) as an emissive material and an inkjet printer (Fujifilm Dimatix DMP-2831). Ink 1 clogged the printer's nozzle and gave non-uniform film. Inks 2 and 3 were used to fabricate PLEDs with ITO/PEDOT:PSS/MEH-PPV/LiF/Al configurations. The best performance (turn-on voltage, 3.5 V; luminance efficiency, 0.17 cd/A; luminance, 1,800 cd/m) was obtained when ink 3 was used to form the emissive layer (thickness, 49 nm), attributable to the better morphology and suitable thickness of the MEH-PPV layer.

Discharge Characteristics of Surface Discharge Type FFL for LCD Backlighting (LCD 백라이트용 면방전형 FFL의 방전 특성)

  • Lim, M.S.;Yun, S.H.;Shin, Y.S.;Jung, D.Y.;Kwon, S.S.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1786-1788
    • /
    • 1999
  • In this paper, we studied Surface Discharge Type Flat Fluorescent Lamp with High Luminance for LCD Backlighting, Liquid Crystal display(LCDs) demand the use of fluorescent lamp as the backlighting source. This lamp is Surface Discharge Type structure with a pair of Sodalime glass, insulator layer, phosphor layer, and Xe gas gap. In spite of its simple structure, the lamp has uniform and stable discharge over entire volume. Till now, we measured the current-voltage(V-I), Firing Voltage, Sustain Voltage for 0.5mm, 1mm electrode gap. In experiment result, long gap cell structure cause high firing voltage. The rising in firing voltage in long gap structure could not be explained by paschen's law because of non-uniform electric field.

  • PDF

High Efficiency LED Driving System using Y type Current Balancing Transformer (Y형 전류평형 트랜스포머를 이용한 고효율 LED 구동시스템)

  • Kim, Jin-Gu;Yoo, Jin-Wan;Park, Chong-Yeon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.223-231
    • /
    • 2015
  • LEDs have been widely used in lighting displays, automobiles, and airplanes owing to their excellent light output characteristics and long lifespan. Though LEDs are manufactured under the same process, variations in impurity concentrations cause electrical deviation among LEDs. The resulting electrical deviation can not only reduce the life time of the LED but also cause non-uniform luminance of LEDs connected in parallel. LED driving circuit is required to solve these problems. In this paper, we propose a LED driving system using Y-type current balancing transformer to maximize the efficiency of the system by removing output stage Schottky diodes. Experimental results are presented to verify the performance of proposed LED driving system that is applied to 80 W LED modules.