• Title/Summary/Keyword: Non-standard Condition

Search Result 215, Processing Time 0.025 seconds

Effect of Various Carbon Sources on the Development of Aspergillus nidulans with $velA^+$ or velA1 allele (각종 탄소원이 $velA^+$ 및 velA1 Aspergillus nidulans의 분화에 미치는 영향)

  • Han, Dong-Min;Han, Yoo-Jeong;Chae, Keon-Sang;Jahng, Kwang-Yeop;Lee, Young-Hoon
    • The Korean Journal of Mycology
    • /
    • v.22 no.4
    • /
    • pp.332-337
    • /
    • 1994
  • Under standard condition (Han, et al., 1990: glucose 1%-nitrate 0.1% minimal medium, 30 ml in 9 cm plate, $10^6$ cells of inoculum per plate), wild type of Aspergillus nidulans developed both sexual and asexual organs in ballance, while velA1 mutant developed asexual ones preferentially. Increase of glucose concentration did not significantly affect the asexual sporulation. However, development of sexual organs were largely affected. It was greatly enhanced when favorable nitrogen source, for example, casein hydrolysate was added, which is contrary to the case of Neurospora or Saccharomyces where limitation of N source induces sexual development. On most of moderate C sources asexual development in $velA^+$ strain was largely inhibited except acetate on which only asexual spores were produced, while that in velA1 mutant strain was not affected. Lactose promoted the sexual development even in velA1 mutant indicating that lactose itself or its metabolic intermediate may induce sexual development independent of allelic state of velA gene. On other moderate favorable C sources, glycerol, galactose and ethanol, asexual development was largely inhibited in $velA^+$ strain but not in velA1 mutant strain. Sexual organs were, however, never produced on acetate. These results suggested that asexual development of wild type is largely dependent on C sources and the velA gene is involved in the repression of asexual development in not-enough-grown (non-competent) thalli resulting in preferential progression of sexual development.

  • PDF

Effect of gas hydrate process on energy saving for reverse osmosis process in seawater desalination plant (해수담수화플랜트에서 가스 하이드레이트 공정 도입을 통한 역삼투 공정의 에너지 절감 효과)

  • Kim, Suhan;Lim, Jun-Heok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.771-778
    • /
    • 2013
  • Gas hydrate (GH) process is a new desalination technology, where GH is a non- stoichiometric crystalline inclusion compounds formed by water and a number of gas molecules. Seawater GH is produced in a low temperature and a high pressure condition and they are separated from the concentrated seawater. The drawback of the GH process so far is that salt contents contained in its product does not meet the fresh water quality standard. This means that the GH process is not a standalone process for seawater desalination and it needs the help of other desalting process like reverse osmosis (RO). The objective of this study is to investigate the effect of GH process on energy saving for RO process in seawater desalination. The GH product water quality data, which were obtained from a literature, were used as input data for RO process simulation. The simulation results show that the energy saving effect by the GH process is in a range of 68 % to 81 %, which increases as the salt removal efficiency of the GH process increases. Boron (B) and total dissolved solids (TDS) concentrations of the final product of the hybrid process of GH and RO were also investigated through the RO process simulation to find relavant salt rejection efficiency of the GH process. In conclusion, the salt rejection efficiency of the GH process should exceed at least 78% in order to meet the product water quality standards and to increase the energy saving effect.

Speech Quality Estimation Algorithm using a Harmonic Modeling of Reverberant Signals (반향 음성 신호의 하모닉 모델링을 이용한 음질 예측 알고리즘)

  • Yang, Jae-Mo;Kang, Hong-Goo
    • Journal of Broadcast Engineering
    • /
    • v.18 no.6
    • /
    • pp.919-926
    • /
    • 2013
  • The acoustic signal from a distance sound source in an enclosed space often produces reverberant sound that varies depending on room impulse response. The estimation of the level of reverberation or the quality of the observed signal is important because it provides valuable information on the condition of system operating environment. It is also useful for designing a dereverberation system. This paper proposes a speech quality estimation method based on the harmonicity of received signal, a unique characteristic of voiced speech. At first, we show that the harmonic signal modeling to a reverberant signal is reasonable. Then, the ratio between the harmonically modeled signal and the estimated non-harmonic signal is used as a measure of standard room acoustical parameter, which is related to speech clarity. Experimental results show that the proposed method successfully estimates speech quality when the reverberation time varies from 0.2s to 1.0s. Finally, we confirm the superiority of the proposed method in both background noise and reverberant environments.

The Study on the Evaluation of Environment Function at Small Stream - In the Case of Hongdong Stream in Hongsung-gun - (농촌지역 소하천의 환경성 평가 연구 - 홍성군 홍동천을 사례로 -)

  • Kang, Banghun;Son, Jin-Kwan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.5
    • /
    • pp.81-101
    • /
    • 2011
  • This study was conducted to understand the environmental and ecological function of habitat through evaluation of water environment, soil environment, vegetation characteristics, macro-invertebrate characteristics, and visual habits environment evaluation (SVAP) in Hongdong stream located in Hongseong-Gun, Chungnam Province, and hereafter to utilize the results for the habits reconstruction and improvement project. As the results of water quality analysis, BOD, COD, T-P was almost below the standard quality from upper stream to down stream. The construction of small reservoir, wetland and water purification facility, and the management of non-point pollution are proposed to improve these problems. The soil texture was sandy soil, which is unfitted with vegetation development. The construction of shallows and bogs, and induction of soil sedimentation and biotope formation are proposed to improve these problems. In the plant flora, total 90 kinds were observed with 81 species and nine varieties in total 36 families and 85 genera, and the naturalization rate was higher at down area than upper area. As the results of macro-invertebrate fauna survey, total 26 species and 297 individuals in 20 families and 22 genera were collected. Peltodytes sinensis, Chironomidae sp., and Culicidae sp., which are observed at polluted environment, were collected as dominant species. An appropriate vegetation management party idea is necessary, and it is done an idea in consideration of the soil and a physical characteristic. Visual habits environment evaluation (SVAP) result was mostly determined with below normal (Fair) grade. Pollution source interception, purification pond establishment, and various bog establishment are proposed to improve these problems. With the above results, the ecological environment was determined with bad condition, and the improvement of biotope was urgently needed through sustainable monitoring and management of streams habitat in rural area.

Improved RPV(reactive-power-variation) anti-islanding method for grid-connected three-phase PVPCS (3상 계통연계형 태양광 PCS의 단독운전검출을 위한 개선된 무효전력변동기법)

  • Lee, K.O.;Jung, Y.S.;So, J.H.;Yu, B.G.;Yu, G.J.;Choi, J.Y.;Choy, I.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1159-1160
    • /
    • 2006
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, this has raised potential problems of network protection on electrical power system. One of the numerous problems is an Island phenomenon. There has been an argument that because the probability of islanding is extremely low it may be a non-issue in practice. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an island can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficient to cause a trip, plus the time required to execute the trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. And, third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an island. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. So the verification of anti-islanding performance is strongly needed. In this paper, the authors propose the improved RPV method through considering power quality and anti-islanding capacity of grid-connected three-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation and experimental results are verified.

  • PDF

An Economic Evaluation under Thailand Feed in Tariff of Residential Roof Top Photovoltaic Grid Connected System with Energy Storage for Voltage Stability Improving

  • Treephak, Kasem;Saelao, Jerawan;Patcharaprakiti, Nopporn
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.1
    • /
    • pp.120-128
    • /
    • 2015
  • In this paper, Residential roof top photovoltaic system with 9.9 kW design is proposed. The system composed of 200 Watts solar array 33 panels connecting in series 10 strings and parallels 3 strings which have maximum voltage and current are 350 V and 23.8 A. The 10 kW sinusoidal grid-connected inverter with window voltage about 270-350 is selected to convert and transfer DC Power to AC Power at PCC (Point of Common Coupling) of power system following to utility standard. However the impact of fluctuation and uncertainty of weather condition of PV may decrease the voltage stability and voltage collapse of power system. In order to solve this problem the energy storage such 120 V 1200 Ah battery bank and 30 kVAR capacitor are designed for voltage stability control. The other expensed for installing the system such battery charger, cable, accessories and maintenance cost are concerned. The economic analysis by using investment from money loan with interest about 7% and use own money which loss income of deposit about 3% are calculated as 671,844 and 547,044 for PV system with energy storage and non energy storage respectively. The solar energy from PV is about 101,616 Bath per year which evaluated by using the value of $5kWh/m^2/day$ from average peak sun hour (PSH) of the Thailand and 6.96 Bath/kWh of Feed in Tariff Incentive. The payback periods of four scenarios are proposed follow as i) PV system with energy storage and use loan money is 15 years ii) PV system with no energy storage and use loan money is 10 years iii) PV system with energy storage and use deposit money is 9 years iv) PV system with energy storage and use deposit money is 7 years. In addition, the other scenarios of economic analysis such no FIT support and other type of economic analysis such NPV and IRR are proposed in this paper.

A Study on the Architectural Planning of the Magnet Resonance Imaging Unit in General Hospital (종합병원 자기공명단층촬영유니트에 관한 건축계획적 연구)

  • Yun Woo-Yong;Chai Choul-Gyun
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.89-96
    • /
    • 2006
  • Magnetic Resonance Imaging (MRI) scanner is the device to draw an image of conditions and the spread of various tissue in the body. It is used by making the patient into rounded superconductor and using high frequency which cause resonances. It uses superconduction magnet and high frequency that is non-ionizing radiation so can acquire biochemical, physical, and functional information of tissue. It is also very useful because it can scan tomography from many different angles to diagnose disease of a nervous system, the heart, and a skeletal structure. It also has advantages of that there is no risk of radiation exposure and the ability of observation on organizations such as brains, livers and the spinal cord of people. Since these features, the rate of use has been increased accordingly more considerations of the security are required when it plans. The weight of devices and the cover problem of the strong magnetic field which is occurred by magnetic resonance at the time of diagnosis can cause very important structure problems and architectural condition. That also the recent tendency which needs stronger equipment means that planning of the MRI unit should generally aim at purposing of the proximity for the device maintenance and up-grade and of further expansion. However there are not enough studies and data on the magnet resonance imaging in domestic hospitals. According to these reasons, this study has an object of indicating basic data on MRI unit plan standard and alternative proposals.

A Study on Traffic Accident Characteristics of Freeway Work Zones (고속도로 공사구간에서 발생하는 교통사고 특성에 관한 연구)

  • Park, Tae-Hoon;Park, Je-Jin;Yoon, Pan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.1
    • /
    • pp.127-136
    • /
    • 2008
  • In these days, frequency of constructions on e freeway are increasing according as growing of the importance of e road maintenance and the road management. Work zone on the freeway where vehicles pass with high speed needs control method of lane closure and construction equipment. Because there are seldom researches in domestic study about reflecting characteristics of domestic road, sometimes we have applied for foreign cases to our traffic circumstance but it is not proper to apply for standard of other countries in our cases. foreign nation has different country square, condition of road, and level of people mind. Therefore, this study shows traffic accident characteristics in freeway work zones in Korea. At first, this study collected traffic accident data which include for 3 years $2003{\sim}2005$ in the whole freeway in Korea and then divided the data to five parts - level of the accident, type of the construction work, type of the accident, reason of the accident, according to geometric. According to comparing with non-work zones accident, this study found traffic accident characteristics in freeway work zones in Korea and suggested some alternative ideas for safety of work zones.

  • PDF

Salt and Pepper Noise Removal using Histogram (히스토그램을 이용한 Salt and Pepper 잡음 제거)

  • Kwon, Se-Ik;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.394-400
    • /
    • 2016
  • Currently, with the rapid development of the digital age, multimedia-related image devices become popular. However image deterioration is generated by multiple causes during the transmission process, with typical example of salt and pepper noise. When the noise of high density is added, existing methods are deteriorated in the characteristics of removal noise. After judging the noise condition to remove the salt and pepper noise, if the center pixel is the non-noise pixel, it is replaced with the original pixel. On the other hand, if it is the noise pixel, algorithm is suggested by the study, where the histogram of the corrupted image and the median filters are used. And for objective judgment, the proposed algorithm was compared with existing methods and PSNR(peak signal to noise ratio) was used as judgment standard. As the result of the simulation, The proposed algorithm shows a high PSNR of 32.57[dB] for Lena images that had been damaged of a high density salt and pepper noise(P=60%), Compared to the existing CWMF, A-TMF and AWMF there were improvements by 21.67[dB], 18.07[dB], and 20.13[dB], respectively.

Analysis on Facilities & Basic Equipment of School Foodservice Safety in Pohang area (포항지역 학교급식의 안전성을 위한 학교 급식 조리실의 기본 시설.설비 조사)

  • Yun, Mi-Yeon;Lee, In-Suk
    • Journal of the Korean Dietetic Association
    • /
    • v.12 no.3
    • /
    • pp.264-276
    • /
    • 2006
  • The purpose of this study was to propose HACCP system implementation properly and to secure the food safety of school foodservices in Pohang city since the proper facilities and equipment should be key factors in food safety and production. So this study was designed to evaluate existing equipment in food production area, receiving and dining area, and employee facilities. Questionnaire was mailed to 107 school foodservice dietitians in Pohang area and 97 were responded (90.7% response rate). Approximately sixty percent of foodservices were not available separate receiving or polluted area, fifty one percent were installed screen door for insecticidal and temperature and humidity control, and these environmental conditions were hard to keep kitchen dry and sanitary condition. Usually public schools were better equipped than private schools. Forty three percent of school foodservice had initial use of non-foodservice, opened before 1994, and thirty three percent of elementary school foodservice. Among employee facilities, hand washing sanitation stand was prepared seventy nine percent (78.9%) of school foodservices. Dietitians chose outworn equipment and facilities (30.9%), difficulties of maintaining standard temperature and humidity for foodservice (20.6%), lacking separate receiving or polluted area (13.4%), indirect contamination of water hoss (10.3%), and lacking employee facilities (10.3%) as critical points to correct in school foodservice. Therefore governmental regulating agencies must review and approval of plans prior to new construction or extensive remodeling of school foodservice facilities. In addition to these requirement, plan must be set-up step by step to implement HACCP system properly.

  • PDF