• Title/Summary/Keyword: Non-seasonal energy

Search Result 22, Processing Time 0.024 seconds

Experimental Study on the Cooling seasonal Performance Factor of Room Air-conditioner (에어컨의 냉방기간 에너지 효율 산출을 위한 실험적 연구)

  • Lee, H.W.;Moon, J.H.;Bae, Y.D.;Park, J.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.204-216
    • /
    • 1992
  • In most cases, EER(Energy Efficiency Ratio) is available to present energy efficiency of air-conditioners. But, EER is not adapt to measure energy efficiency at actual life environment because it is based on fixed temperature and humidity contditions. To overcome this disadvantage, there is need to introduce SEER(Seasonal Energy Efficiency Ratio) established at time varient temperature and humidity conditions. In this paper, SEER measurement method and conditions based on actual life environment of the country is introduced, and discussed SEER value about two air-conditioner type, that is, non inverter air-conditioner and inverter air-conditioner. As a result of, inverter air-conditioner was superior to non inverter air-conditioner at cooling seasonal energy efficiency.

  • PDF

Analysis of Economics through Control Method of Heat Source Equipment in Seasonal Air conditioning Building

  • Park, Yool;Kim, Samuel;Jung, Soon-Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.209-217
    • /
    • 2003
  • The term “energy saving is economical” is appropriate for the national view point and for design and assessment of one system, but not appropriate when choosing the system by comparing alternative systems in the early design step. Sometimes, non-energy saving system is more economical than energy saving system because of the price of electricity, gas or oil, which are used for operating the air conditioning system. Therefore, when designing a system, we should consider the efficient alternatives through economic assessment of energy saving method. However, research on non-operating number control of the system is not sufficient because it is more common to use operating number control of the system for most economic assessment of air conditioning systems. For this reason, this research can provide the economic operating number control method as basic design data. The data obtained through analysis of life cycle cost based on amount of yearly energy use, are produced by system simulation of HASP/ACLD/8501 and HASP/ACSS/8502 for six alternative heating$.$cooling systems based on seasonal air conditioning system, which is widely used for medium and large size office buildings in Busan.

A Study on the Application of the Solar Energy Seasonal Storage System Using Sea water Heat Source in the Buildings (해수냉열원을 이용한 태양열계간축열시스템의 건물냉방 적용에 관한 연구)

  • Kim, Myung-Rae;Yoon, Jae-Ock
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.56-61
    • /
    • 2009
  • Paradigm depending only on fossil fuel for building heat source is rapidly changing. Accelerating the change, as it has been known, is obligation for reducing green house gas coming from use of fossil fuel, i.e. reaction to United Nations Framework Convention on Climate Change. In addition, factors such as high oil price, unstable supply, weapon of petroleum and oil peak, by replacing fossil fuel, contributes to advance of environmental friendly renewable energy which can be continuously reusable. Therefore, current new energy policies, beyond enhancing effectiveness of heat using equipments, are to make best efforts for national competitiveness. Our country supports 11 areas for new renewable energy including sun light, solar heat and wind power. Among those areas, ocean thermal energy specifies tidal power generation using tide of sea, wave and temperature differences, wave power generation and thermal power generation. But heat use of heat source from sea water itself has been excluded as non-utilized energy. In the future, sea water heat source which has not been used so far will be required to be specified as new renewable energy. This research is to survey local heating system in Europe using sea water, central solar heating plants, seasonal thermal energy store and to analyze large scale central solar heating plants in German. Seasonal thermal energy store necessarily need to be equipped with large scale thermal energy store. Currently operating central solar heating system is a effective method which significantly enhances sharing rate of solar heat in a way that stores excessive heat generating in summer and then replenish insufficient heat for winter. Construction cost for this system is primarily dependent on large scale seasonal heat store and this high priced heat store merely plays its role once per year. Since our country is faced with 3 directional sea, active research and development for using sea water heat as cooling and heating heat source is required for seashore villages and building units. This research suggests how to utilize new energy in a way that stores cooling heat of sea water into seasonal thermal energy store when temperature of sea water is its lowest temperature in February based on West Sea and then uses it as cooling heat source when cooling is necessary. Since this method utilizes seasonal thermal energy store from existing central solar heating plant for heating and cooling purpose respectively twice per year maximizing energy efficiency by achieving 2 seasonal thermal energy store, active research and development is necessarily required for the future.

  • PDF

Loading of Organic Matter according to Seasonal Changes into Lake Paldang during Non-storm Period (계절에 따른 비강우시 팔당호의 유기물 유입부하량)

  • Gil, Kyungik;Shin, Jiwoong;Hur, Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.433-437
    • /
    • 2011
  • The study is conducted to evaluate loading of organic matter as seasonal changes during non-storm period into Lake Paldang which is used to a major drinking water source. Samples were taken in Lake Paldang intake during non-storm period and were analyzed loading of organic matter. From the results of the survey, improving of the water quality showed remarkable tendency depending on the changing periods from summer to fall and from fall to winter. Dilution effect from the increase of base run-off caused by the concentrated rainfall in rainy season, the characteristics of Korea's climate seems to have to be the reason. On the other hand, deteriorating of the water quality showed tendency depending on the changing periods from winter to spring and from spring to summer. Increase of Cyanobacteria etc. is explained by seasonal effects which are a small amount of the rainfall in winter and spring and gradational increase of water temperature.

A Study on the Comparison for Energy Consumption Characteristics between G-SEED certified and non-certified Office Buildings in Korea (G-SEED 인증 건축물과 비인증 건축물의 에너지 소비량 특성에 관한 연구 : 업무시설을 대상으로)

  • Kim, Jong-Hyun;Kim, Jin-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.33-43
    • /
    • 2019
  • Considerable efforts have been made to reduce greenhouse gas emission around the world to cope with climate change. The government is implementing G-SEED certification to promote energy efficient building design. This study aims to verify the effectiveness of the G-SEED certification system by analyzing the actual energy use of certified and non-certified office buildings. For this purpose, the energy consumption of 135 certified and 142 non-certified office buildings was analyzed according to the seasonal characteristics, building size and number of floors, approval year, and certification grade. The energy saving effects of certified buildings was about 50% higher than that of non-certified buildings. The seasonal energy consumption of buildings is closely related to the heating degree-days. The energy consumption of certified and non-certified buildings decreases with increasing approval year. On the other hand, the energy consumption according to building size and certification grade is not related. This study provides meaningful basic data of G-SEED certification system for future improvement. As the building energy performance standards are strengthened over the years, it is necessary to make the individual score of G-SEED certified projects open to the public to configure the factors of energy efficiency.

A Case Study on Energy Consumption and Calibration of Green Remodeling Buildings (그린리모델링 건물에 대한 에너지소비량 및 보정 사례연구)

  • Kim, Dongi;Lee, Byeongho
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.5
    • /
    • pp.47-58
    • /
    • 2020
  • Ministry of Land, Infrastructure and Transport(MOLIT) has increased reduction rate from 18.1% to 32.7% in Building sector compared to BAU of the national greenhouse gas emission according to the 2030 Greenhouse Gas Reduction Road map Amendment. For this purpose, MOLIT has been activating the green remodeling projects for existing buildings. Considering that 15 year old buildings after completion are 74% (5.25 million buildings) among about 7 million existing building stocks in Korea, reduction of building energy consumption by green remodeling is urgently needed, However, it is a major difficulty of activation for green remodeling projects because there are few case studies on Before and After building energy consumption of actual green remodeling projects. Considering that building energy performance and value increase after green remodeling through previous researches, additional studies of the energy consumption assessment on actual green remodeling projects are essential. Therefore, this study aims to propose results on Before and After building energy consumption of actual green remodeling projects.

Time-Series Estimation based AI Algorithm for Energy Management in a Virtual Power Plant System

  • Yeonwoo LEE
    • Korean Journal of Artificial Intelligence
    • /
    • v.12 no.1
    • /
    • pp.17-24
    • /
    • 2024
  • This paper introduces a novel approach to time-series estimation for energy load forecasting within Virtual Power Plant (VPP) systems, leveraging advanced artificial intelligence (AI) algorithms, namely Long Short-Term Memory (LSTM) and Seasonal Autoregressive Integrated Moving Average (SARIMA). Virtual power plants, which integrate diverse microgrids managed by Energy Management Systems (EMS), require precise forecasting techniques to balance energy supply and demand efficiently. The paper introduces a hybrid-method forecasting model combining a parametric-based statistical technique and an AI algorithm. The LSTM algorithm is particularly employed to discern pattern correlations over fixed intervals, crucial for predicting accurate future energy loads. SARIMA is applied to generate time-series forecasts, accounting for non-stationary and seasonal variations. The forecasting model incorporates a broad spectrum of distributed energy resources, including renewable energy sources and conventional power plants. Data spanning a decade, sourced from the Korea Power Exchange (KPX) Electrical Power Statistical Information System (EPSIS), were utilized to validate the model. The proposed hybrid LSTM-SARIMA model with parameter sets (1, 1, 1, 12) and (2, 1, 1, 12) demonstrated a high fidelity to the actual observed data. Thus, it is concluded that the optimized system notably surpasses traditional forecasting methods, indicating that this model offers a viable solution for EMS to enhance short-term load forecasting.

Seasonal Changes in Energy-related Blood Metabolites and Mineral Profiles of Nguni and Crossbred Cattle on Communal Rangelands in the Eastern Cape, South Africa

  • Mapiye, C.;Chimonyo, M.;Dzama, K.;Marufu, M.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.6
    • /
    • pp.708-718
    • /
    • 2010
  • The objective of the current study was to determine seasonal changes in glucose, cholesterol, non-esterified fatty acids (NEFA), serum inorganic phosphorous (SIP), calcium, magnesium and iron concentrations in Nguni and crossbred cattle on the sweet and sour rangelands of the Eastern Cape Province of South Africa. Body weights, body condition scores (BCS) and serum concentrations of energy-related metabolites and mineral profiles were determined in late cool-dry, hot-dry, hot-wet, post-rainy and early cool-dry seasons in 100 cattle raised on communal rangelands from August 2007 to May 2008. Nguni cattle had lower (p<0.05) and higher (p<0.05) serum concentrations of glucose in the hot-wet and post-rainy seasons, respectively, compared to crossbreds in the same seasons. Serum cholesterol and NEFA concentrations in Nguni were lower (p<0.05) than in the crossbreds. Nguni and crossbred cattle had higher (p<0.05) serum NEFA concentrations on the sweet rangeland during the late cool-dry season than on sour rangeland. Nguni cattle had higher (p<0.05) SIP concentration in the hot-wet season than the crossbreds. Generally, both breeds had lowest SIP concentration during the hot-wet season on the sour rangeland. The lowest magnesium and highest iron concentrations were observed in the hot-wet and post-rainy seasons, respectively, compared to other seasons. Cattle on the sour rangeland had lower (p<0.05) iron concentrations than those on the sweet rangeland. It was concluded that Nguni cattle had lower cholesterol and NEFA, and higher SIP concentrations in the hot-wet season than crossbreds and energy deficits mostly occurred during the late cool-dry season on the sweet rangeland.

An Improved Photovoltaic System Output Prediction Model under Limited Weather Information

  • Park, Sung-Won;Son, Sung-Yong;Kim, Changseob;LEE, Kwang Y.;Hwang, Hye-Mi
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1874-1885
    • /
    • 2018
  • The customer side operation is getting more complex in a smart grid environment because of the adoption of renewable resources. In performing energy management planning or scheduling, it is essential to forecast non-controllable resources accurately and robustly. The PV system is one of the common renewable energy resources in customer side. Its output depends on weather and physical characteristics of the PV system. Thus, weather information is essential to predict the amount of PV system output. However, weather forecast usually does not include enough solar irradiation information. In this study, a PV system power output prediction model (PPM) under limited weather information is proposed. In the proposed model, meteorological radiation model (MRM) is used to improve cloud cover radiation model (CRM) to consider the seasonal effect of the target region. The results of the proposed model are compared to the result of the conventional CRM prediction method on the PV generation obtained from a field test site. With the PPM, root mean square error (RMSE), and mean absolute error (MAE) are improved by 23.43% and 33.76%, respectively, compared to CRM for all days; while in clear days, they are improved by 53.36% and 62.90%, respectively.

The Distribution Characteristics and Long-term Trend of Carbonaceous Species in Airborne Particulate in Seoul between 1986 and 1996

  • Hwang, Kyung-Chul;Ma, Chang-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E1
    • /
    • pp.11-20
    • /
    • 2003
  • To characterize airborne particulate carbon and its temporal variation in the heavily industrialized metropolitan city, Seoul in South Korea, aerosol sampling was performed from 1986 to 1996. Correlation coefficients of elemental carbon (EC) and organic carbon (OC) with mass concentration of fine particles ($\underline{\leq}$2.1 ${\mu}m$) are 0.73 and 0.51, respectively. EC concentrations of the fine particle mode are 10.1, 5.9, 4.5, and 7.4 ${\mu}g\;m^{-3}$ in winter, spring, summer, and autumn, respectively. On the other hand, OC concentration shows maximum value in winter and followed by autumn, summer, and spring. A seasonal peak in the ratio of OC to EC in fine particles was observed during the summer photochemical season from June to August. Concentrations of EC and OC in Asian dust storm events are generally higher than in non- Asian dust storm events except in 1990. The difference of EC concentrations between Asian dust storm periods and non-Asian dust storm periods are much larger than those of OC concentrations. There are slight increases of EC concentration between 1987 and 1990 and a gradual decrease between 1990 and 1996.