• 제목/요약/키워드: Non-precious metal

검색결과 77건 처리시간 0.031초

국내에서 제작된 고정성 보철물의 수명과 실패 요인 및 양상 (LONGEVITY AND FAILURE ANALYSIS OF FIXED RESTORATIONS SERVICED IN KOREA)

  • 신우진;전영식;이근우;이호용;한동후
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.158-175
    • /
    • 2005
  • Statement of problem. Every effort has been continually made to obtain objectivity in measuring the longevity of fixed restorations, such as by establishing unified judgement standard for deciding success and adopting statistical method that analyzes the data of successful and failed cases at the same time. In Korea, however desired level of development has not to be made in this field yet. Purpose. This study, adopting California Dental Association (CDA) quality evaluation system, established objective standard for deciding success, and inferred the longevity of fixed restorations and their failure analysis through adopting Kaplan-Meier survival analysis. Material and method. In order to assess the longevity of flxed restorations serviced in Korea and causes of failure, a total of 1109 individuals (aged 15-74, 716 women and 393 men loaded with 2551 unit fixed restorations, and 1934 abutments) who lived in Kyung-In Province were examined and the findings were as follows : Results. 1. Length of service of fixed restorations serviced in Korea was 6.86$\pm$0.15 yr (mean), 5.5 yr (median), and the rate of success was 65.82% in 5 year survival, and 21.15% in 10 year survival. 2. When there was patient's need for replacing old prosthetics, longevity of fixed restorations was 7.51$\pm$0.27 yr (mean), 7 yr (median), and the rate of success was 61.08% in 5 year survival, and 17.57% in 10 year survival. 3. Longevity of fixed restorations was longest in the over-sixty age group(9.21$\pm$0.66) and that of the teen age group(3.39$\pm$0.28) was shortest (p<0.05). 4. Longevity of fixed restorations of women (7.38$\pm$0.18 years) was longer than that of men (6.00$\pm$0.26) (p<0.05). 5. As for the provider factor (such as unlicensed performers, university hospitals, and private clinic), there was no statistically significant difference in longevity of fixed restorations. 6. Defective margin (34.78%). periodontal disease (12.15%), periapical involvement (11.73%), was the most frequent causes of failure and poor esthetics group showed the longest life above all (p<0.05). Actual frequent causes of failure after removing old prosthetics were defective margin, periapical involvement, periodontal disease and uncemented restoration. In 75.67% of the cases, abutment state after removing old prosthetics was good enough for loading another prosthetics. 7. There was found to have statistically significant influence between longevity of single crown (6.35$\pm$0.20 yr) and that of 3 unit fixed restorations (7.60$\pm$0.30 y) (p<0.05). In each case the most frequent cause of failure was defective margin. 8. The number of cantilever pontic, pontic/abutment ratio, oral hygiene status were found to have no statistically significant influence on longevity of fixed restorations in all groups (p>0.05). 9. Longevity of fixed restorations made of non precious metal was longest (9.60$\pm$0.40 yr) semi precious and precious trailing behind(p<0.05). 10. Group function group (37.04%) and partial group function group (44.62%) were predominant in frequency but showed no correlation between them and among different types of occlusal plane and different types of occlusal surface (p>0.05). 11. Longevity of fixed restorations was longest in the centric interference group(9.35$\pm$0.62) (p<0.05) among different types of occlusal interference. Conclusion. We found that longevity of fixed restorations serviced in Korea is affected by age, gender and type of material, and that most frequent cause of failure is defective margin. In order to assess the accurate longevity of axed restorations, unified research design. overcoming inter-observer difference and establishing the objective research items are needed. Furthermore, it is thought that prospective approach through thorough study and regular follow-ups is needed just from the start of research. Nationwide detailed studies on length of service of fixed restorations manufactured in Korea are hoped to be conducted hereafter.

주조연결된 니켈-크롬-베릴리움 주조체의 굽힘강도에 관한 비교연구 (FLEXURE STRENGTH OF CAST-JOINED CONNECTOR WITH Ni-Cr-Be ALLOY)

  • 정창모;전영찬;임장섭
    • 대한치과보철학회지
    • /
    • 제36권6호
    • /
    • pp.858-866
    • /
    • 1998
  • Soldering is the usual method used to correct an unstable fixed partial denture framework at patient's try-in; However, presoldering base metal alloys is technique-sensitve and results are unstable because it is difficult to maintain uniform heat distribution and to prevent oxidation of an alloy. A cast-joining technique has been developed by Weiss and Munyon for repair, correction and addition to base metal framework. This joining technique eliminates the problem with presoldering of non-precious frameworks. The object of this study was to 1) compare the relative flexure strength and the joining effectiveness of Ni-Cr-Be cast in two pieces and 'pre-soldered' versus in two pieces and 'cast-joined'. 2) determine the effect of increasing the number of retentive grooves on the face of the cast and 3) determine the effect of the relative matched position of groove patterns on flexure strength. The joining effectiveness can be expressed by the ratio of the mean flexure stress of soldered or cast-joined specimens to that of one-piece cast. Resin rods 3mm in diameter were used as pattern of specimens for one-piece casted, presoldered, and cast-joined groups. Cast-joined specimens had two different patterns of retentive grooves on the joined faces. Type A had cross-shaped grooves 1mm in depth. 0.6mm in width. Type B was the same except for the addition of one more retentive groove. In the experiment connecting cast-joined specimens, half of specimens with type A pattern had their patterns on the faces of paired casts matched with each other as mirror image. With the rest pairs, it was proceeded that one of paired casts turned 45 degrees so that the patterns crossed. Half of specimens with type B pattern also had the patterns matched as mirror image; However, here, one of paired casts turned 90 degrees with the other pairs. Retentive groove in this study lacked the intentional undercuts, in contrast with the suggestion of Weiss and Munyon. The specimens were subjected to four-point flexural loading in an Instron testing machine. The midspan flexural stress was calculated at the point of initial plastic strain as determined from a strip-chart recorder or at the point of failure if this occured at a lower stress level. Within the scope of this study, the following results were obtained. 1. The presoldered group showed flexural strength at least 2 times higher than the cast-joined groups. Its joining effectiveness was 82%. 2. In cast-joined groups, the flexural strength of joints with type B patterns exhibited 1.5 times that of joints with type A patterns. Joining effectivenesses were 38% for type B patterns, 25-26% for type A patterns. 3. The relative matched position of groove patterns did not have any significant effect on flexural strength of the cast-joined specimens with either type A patterns or type B patterns(p>.05).

  • PDF

치과용 주조 합금의 방전가공에 따른 표면 성분 변화 (Elemental alteration of the surface of dental casting alloys induced by electro discharge machining)

  • 장용철;이명곤
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.55-61
    • /
    • 2009
  • Passive fitting of meso-structure and super-structures is a predominant requirement for the longevity and clinical success of osseointegrated dental implants. However, precision and passive fitting has been unpredictable with conventional methods of casting as well as for corrective techniques. Alternative to conventional techniques, electro discharge machining(EDM) is an advanced method introduced to dental technology to improve the passive fitting of implant prosthesis. In this technique material is removed by melting and vaporization in electric sparks. Regarding the efficacy of EDM, the application of this technique induces severe surface morphological and elemental alterations due to the high temperatures developed during machining, which vary between $10,000{\sim}20,000^{\circ}C$. The aim of this study was to investigate the morphological and elemental alterations induced by EDM process of casting dental gold alloy and non-precious alloy used for the production of implant-supported prosthesis. A conventional clinical dental casting alloys were used for experimental specimens patterns, which were divided in three groups, high fineness gold alloy(Au 75%, HG group), low fineness gold alloy(Au 55%, LG group) and nonprecious metal alloy(Ni-Cr, NP group). The UCLA type plastic abutment patterns were invested with conventional investment material and were cast in a centrifugal casting machine. Castings were sandblasted with $50{\mu}m\;Al_2O_3$. One casting specimen of each group was polished by conventional finishing(HGCON, LGCON, NPCON) and one specimen of each group was subjected to EDM in a system using Cu electrodes, kerosene as dielectric fluid in 10 min for gold alloy and 20 min for Ni-Cr alloy(HGEDM. LGEDM, NOEDM). The surface morphology of all specimens was studied under an energy dispersive X-ray spectrometer (EDS). The quantitative results from EDS analysis are presented on the HGEDM and LGEDM specimens a significant increase in C and Cu concentrations was found after EDM finishing. The different result was documented for C on the NPEDM with a significant uptake of O after EDM finishing, whereas Al, Si showed a significant decrease in their concentrations. EDS analysis showed a serious uptake of C and Cu after the EDM procedure in the alloys studied. The C uptake after the EDM process is a common finding and it is attributed to the decomposition of the dielectric fluid in the plasma column, probably due to the development of extremely high temperatures. The Cu uptake is readily explained from the decomposition of Cu electrodes, something which is also a common finding after the EDM procedure. However, all the aforementioned mechanisms require further research. The clinical implication of these findings is related with the biological and corrosion resistance of surfaces prepared by the EDM process.

  • PDF

베릴륨이 포함되지 않은 도재용착용 비귀금속 합금과 세라믹간의 전단결합강도와 계면특성 (Shear Bond Strength and Interfacial Characterization of Ceramic to Beryllium Free Nonprecious Alloys for Porcelain Fused to Metal Crown)

  • 정인성;김치영
    • 한국콘텐츠학회논문지
    • /
    • 제10권11호
    • /
    • pp.228-234
    • /
    • 2010
  • 치과도재용 합금으로 사용되는 합금 중 베릴륨이 함유된 비귀금속 Ni-Cr합금과 베릴륨이 함유되지 않은 비귀금속 Ni-Cr합금 그리고 베릴륨이 함유되지 않은 비귀금속 Co-Cr 합금과 세라믹간의 결합강도와 파절양상 그리고 계면특성을 분석하고자 하였다. 결합강도는 만능시험기를 이용하여 전단력시험을 통하여 전단결합력을 측정하였으며, 전단시험에 의한 파단면을 이용하여 파절양상을 관찰하였다. 그리고 합금-도재간의 계면을 관찰하였다. 전단결합강도 측정 결과, 베릴륨이 포함된 T-3가 41.13(${\pm}5.11$)MPa로 가장 높게 나타났으며, 베릴륨이 포함된 VeraBond(40.72(${\pm}5.98$)MPa), Co-Cr 합금인 Wirobond(38.40(${\pm}9.66$)MPa), 베릴륨이 포함되지 않은 Verabond 2V(32.77(${\pm}4.31$)MPa), Bellabond N(28.63(${\pm}6.39$)MPa), Bellabond plus(24.97(${\pm}6.13$)MPa), Argeloy N.P. Star(22.69(${\pm}3.41$)MPa) 순으로 나타났다. 비귀금속 합금들과 세라믹간의 파절양상은 모든 시편에서 금속표면에 세라믹이 일부 부착된 복합파절(mixed failure) 양상을 보였다.

고정성 보철물의 임상적 상태에 대한 평가 (Evaluation of clinical status of fixed prosthesis)

  • 윤미정;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.99-107
    • /
    • 2009
  • 연구목적: 악구강계의 건강을 심미적, 기능적으로 유지 및 증진시키는 것을 목적으로 치아의 형태 이상이나 결손 등을 갖고 있는 환자들에게 고정성 보철 술식이 보편적으로 시술되어 오고 있다. 환자 스스로의 관리 부족과 더불어 부적절한 기공 과정으로 인해 보철물과 연관된 합병증이 발생할 수 있다. 이를 해결하고자 고정성 보철물의 장기간의 임상 상태 조사에 많은 노력을 기울여 왔으나 자료 수집에 어려움이 많았다. 이에 본 연구에서는 고정성 보철물의 임상적 상태를 조사하여 보철물의 치료 계획과 생존율을 높이는 guideline에 기여하고자 하였다. 연구 재료 및 방법: 2007년 4월에서 9월까지 6개월간 부산대학교병원 치과 보철과에 내원한 초진 환자 중 고정성 보철물을 장착하여 사용 중인 환자를 대상으로 보철물과 관련한 종합적인 상태를 조사하였다. 결과 및 결론: 1. 전체 고정성 보철물의 추정 수명은 10.0년이었고, 평균 장착 기간은 $8.6{\pm}0.6$년이었다. 2. 부위별 추정 수명은 차이가 없었으나(P>.05), 성공률은 하악과 구치부 보철물에서 높았고(P<.05), 전치-구치 혼합형 보철물에서는 실패율이 높았다(P<.05). 3. 재료별 추정 수명은 금속관이 14.0년으로 가장 길었고, 금합금관(10.0년), 귀금속 도재관(10.0년), 비귀금속 도재관(8.0년) 순이었다(P<.05). 그러나 금속관은 실패율이 높았고, 성공률은 금합금관과 귀금속 도재관에서 높았다. 4. 크기별 추정 수명은 차이를 보이지 않았으나(P>.05), 성공률은 단일관에서 높았고(P<.05), 실패율은 3-유닛 이상에서 높았다(P<.05). 5. 대합치 조건별 추정 수명은 차이가 없었으나(P>.05), 고정성 및 가철성 국소 의치가 대합치인 경우 실패율이 높았고, 자연치일 경우 성공률이 높았다(P<.05). 6. 고정성 보철물의 합병증은 치아 우식증(23.0%), 치주 질환(19.3%), 치수 질환(16.9%) 순이었고, 기계적 문제점은 변연 결함(28.2%), 보철물 파절(6.7%), 유지력 상실(4.8%) 순이었다. 보철물을 제거한 후 잔존 치질은 고정성 보철물의 합병증으로 인하여 30.1%가 수복 불가능한 상태였다.

비철금속(非鐵金屬)의 생산(生産), 소비(消費), 시세(時勢)의 추이(推移) (The Transition of Production, Consumption and Price of Non-ferrous Metals)

  • 문원주
    • 자원환경지질
    • /
    • 제2권3호
    • /
    • pp.1-25
    • /
    • 1969
  • In considering the mining industry, it is necessary to study the production, consumption and price of ore and metals in every country of the world in order to determine the trend of the industry in the present and for the future. This study is necessary especially for exporting domestically produced are which is in excess of domestic consumption and for importing are, or metal where local production does not meet domestic demand. It will be treated of Au, Ag, Cu, Pb, Zn, W, Mo, which are the most important non-ferrous metals, and which greatly affect the mining industry of Korea. The presentation will concern itself only with the free world. About 1, 200 ton of gold are produced annually with little fluctiation in recent years. Most of the gold produced is consumed by advanced countries for industrial uses as well as for producing precious objects. The U.S.A. expends yearly about four times its domestic production and Japan about three times its domestic production for industry and arts. Because of the instability of the currency of the U.S.A., England and France, recently, the price of gold has been $ 41-42 per ounce, whereas the official price is $35.00 per ounce. It will be expected that the official price will be raised in the near future. As for silver, about 6,500 tons are produced annually with no special fluctuation change in recent years. However, the annual consumption is about 14,000 ton, so the supply and demand is extremely unbalanced. The shortage is made up by the sale of the U.S. treasury's reserve stock and the reclaiminig of silver from coins and other scrap. As the Treasury'S reserves will be exhausted in a year or two, the price of silver which is $1. 64 per ounce, will go up drastically in about a year. As for copper, 5,257,000 ton's were mined in 1966. It's production is being increased about 5% annually. However, consumption exceeds production by about 100,000 ton a year. The recent Foreign refinery copper price in the U.S.A is $ 60 per pound. The supply of copper being insufficient to meet international demands, the price will go up and with no prospect of being lowered in the near future even with the slight annual increase in production. About 2,100,000 to 2,200,000 tons of lead are produced annually. Consumption exceeds production by about 50,000-60,000 tons annually. The current price of lead in New York is $ 155 per pound. As the supply of lead is internationally stable, It will be believed that there will be no significant change in its price in the near future. In 1967, 3,926,000 tons of Zinc were produced. There is annual increase of 4-7% in production. The annual consumption exceeds production by 100,000 to 200,000 tons. The current zinc price in the St. Louis market inthe U.S.A. is $ 145 per pound. Even though its supply is stable and sufficient world wide, the consumption rate will increase at a faster pace than before; hence, the price will slowly go up. Tungsten mines yield about 11,000 tons a year. Its production has been relatively constant in the past few years. The amount of its consumption increases slowly world wide, but in the free world· there has been a slight annual decrease. However, since Red China has not been exporting their tungsten to other countries for several months, the price on the London market of S.T.U. of $Wo_3$ has increased to $ 44~46. Should Red China begin to export actively again the price will drop to $ 40~42. In 1967, 56,000 tons of Molybdenum were produced. Production exceeds consumption by 200,000 -30,000 tons annually. The current price in the U.S.A. is $ 1.72 per Mo pound. Since the rate of production in the U.S.A. is on the increase with large amounts of ore reserve, the price of molubdenum should not go up.

  • PDF

치과 보철 재료 표면에서 MnO2-diatom microbubbler의 세균막 제거 효과 연구: In vitro study (The biofilm removal effect of MnO2-diatom microbubbler from the dental prosthetic surfaces: In vitro study)

  • 이은혁;서용범;권호범;임영준;공현준;김명주
    • 대한치과보철학회지
    • /
    • 제58권1호
    • /
    • pp.14-22
    • /
    • 2020
  • 목적: 본 연구의 목적은 보철 재료 표면에서 MnO2-diatom microbubbler (DM)의 세균막 제거 효과를 기존에 치과 임상에 구강세정제로 사용되고 있는 성분들과 비교하여 이 재료가 구강세정제로 사용될 수 있는 가능성을 평가하는 것이다. 재료 및 방법: 이산화망간 나노 시트가 도핑된 DM을 만들었고, 주사전자현미경(SEM)을 이용하여 형태에 대한 관찰 및 도핑된 MnO2의 성분 분석을 시행하였다. 3% 과산화수소수에서 DM의 반응을 시간에 따라 관찰하기 위해 실체 현미경을 이용하였다. 보철 재료 표면의 세균막 제거 효과를 평가하기 위해 비귀금속 합금, 지르코니아, 레진 시편을 제작하였고 치아우식의 원인균이며 호기성 세균인 Streptococcus mutans와 치주질환의 원인균이며 혐기성 세균인 Porphyromonas gingivalis 세균막을 각각 형성하였다. 형성된 세균막에 3% 과산화수소수와 DM을 처리하였을 때 세균막 제거 효과를 클로르헥시딘 글루코네이트와 3% 과산화수소수의 경우와 crystal violet 염색 실험을 통해 비교 평가하였다. 결과: 속이 빈 원통 형태의 규조류에 이산화망간 성분이 발견되었고, 3% 과산화수소수에서 기체를 만들어내는 것을 확인할 수 있었다. 실험에 이용된 모든 재료에서 DM을 처리한 군이 클로르헥시딘 글루코네이트나 3% 과산화수소수 단독으로 사용한 군에 비해 통계적으로 유의하게 세균막을 효과적으로 제거하였다. 결론: MnO2-diatom microbubbler는 보철 재료 표면의 세균막을 기존의 구강세정제 성분에 비해 더 효과적으로 제거할 수 있다.