Watershed Management Measures for Water Quality Conservation of the Hwaseong Reservoir using BASINS/HSPF Model (BASINS/HSPF 모델을 이용한 화성호 수질보전을 위한 상류 유역 수질개선방안 연구)

  • Kang, Hyeongsik;Jang, Jae Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.36-44
    • /
    • 2013
  • HSPF model based on BASINS was applied to analyze effects of watershed management measures for water quality conservation in the Hwaseong Reservoir watershed. The model was calibrated against the field measurements of meteorological data, streamflow and water qualities ($BOD_5$, T-N, T-P) at each observatory for 4 years (2007-2010). The water quality characteristics of inflow streams were evaluated. The 4 scenarios for the water quality improvement were applied to inflow streams and critical area from water pollution based on previous researches. The reduction efficiency of point and non-point sources in inflow streams was evaluated with each scenario. The results demonstrate that the expansion of advanced treatment system within wastewater treatment plants (WWTPs) and construction of pond-wetlands would be great effective management measures. In order to satisfactory the target water quality of reservoir, the measures which can control both point source and non-point source pollutants should be implemented in the watershed.

Lake Water Quality Modelling Considering Rainfall-Runoff Pollution Loads (강우유출오염부하를 고려한 호수수질모델링)

  • Cho, Jae-Heon;Kang, Sung-Hyo
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.2
    • /
    • pp.59-67
    • /
    • 2009
  • Water quality of the Lake Youngrang in the Sokcho City is eutrophic. Jangcheon is the largest inflow source to the lake. Major pollutant sources are stormwater runoff from resort areas and various land uses in the Jangcheon watershed. A storm sewer on the southern end of the lake is also an important pollution source. In this study, water quality modelling for Lake Youngrang was carried out considering the rainfall-runoff pollution loads from the watershed. The rainfall-runoff curves and the rainfall-runoff pollutant load curves were derived from the rainfall-runoff survey data during the recent 4 years. The rainfall-runoff pollution loads and flow from the Jangcheon watershed and the storm sewer were estimated using the two kinds of curves, and they were used as the flow and the boundary data of the WASP model. With the measured water quality data of the year 2005 and 2006, WASP model was calibrated. Non-point pollution control measures such as wet pond and infiltration trench were considered as the alternative for water quality management of the lake. The predicted water quality were compared with those under the present condition, and the improvement effect of the lake water quality were analyzed.

New Control Strategy for Conventional VSI in Islanded Microgrid to Enhance Voltage Quality under Nonlinear Loads

  • Dam, Duy-Hung;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.351-352
    • /
    • 2015
  • This paper proposed a new control strategy for voltage source inverter (VSI) of effective fifth and seventh harmonic reduction in the point of common coupling (PCC) in islanded microgrid under nonlinear load without any additional hardware devices. The non-linear load regularly causes such harmonic distortion, which harmfully affect the performance of other loads or other distributed generation (DG) sources connect to the PCC. In order to improve the quality of delivered output voltage, these harmonic must be rejected. The proposed control strategy is developed based on the current controller formed by resonant controller parallel with a proportional integral controller, which perform on the fundamental reference frame. The reference current is estimated based on the voltage harmonic and the injecting power. The simulation and experimental results are shown to verify the effectiveness of proposed control method.

  • PDF

Study on the Management of Doam Dam Operation by the Analysis of Suspended Solids Behavior in the lake (호내 부유물질 거동 분석을 통한 도암댐 운영 방안에 관한 연구)

  • Yeom, Bo-Min;Lee, Hye Won;Moon, Hee-Il;Yun, Dong-Gu;Choi, Jung Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.6
    • /
    • pp.470-480
    • /
    • 2019
  • The Doam lake watershed was designated as a non-point pollution management area in 2007 to improve water quality based on watershed management implementation. There have been studies of non-point source reduction with respect to the watershed management impacting the pollutant transport of the reservoir. However, a little attention has been focused on the impact of water quality improvement by the management of the dam operation or the guidelines on the dam operation. In this study, the impact of in-lake management practices combined with watershed management is analyzed, and the appropriate guidelines on the operation of the dam are suggested. The integrated modeling system by coupling with the watershed model (HSPF) and reservoir water quality model (CE-QUAL-W2) was applied for analyzing the impact of water quality management practices. A scenario implemented with sedimentation basin and suspended matter barrier showed decrease in SS concentration up to 4.6%. The SS concentration increased in the scenarios adjusting withdrawal location from EL.673 m to the upper direction(EL.683 m and EL.688 m). The water quality was comparably high when the scenario implemented all in-lake practices with water intake at EL.673 m. However, there was improvement in water quality when the height of the water intake was moved to EL.688 m during the summer by preventing sediments inflow after the rainfall. Therefore, to manage water quality of the Doam lake, it is essential to control the water quality by modulating the height of water intake through consistent turbidity monitoring during rainfall.

Problems and their Counter-measures in Water Quality Preservation (수질보전상의 문제와 대책)

  • Ryu Jae Keun
    • Journal of environmental and Sanitary engineering
    • /
    • v.2 no.2 s.2
    • /
    • pp.69-78
    • /
    • 1987
  • Due to the increase of population and development of industry, the demand of available water resources increased . Many reservoirs have been constructed in large scales to meet this urgent need , resulting in the increased amount of water resources. After the constructions, however, serious pollution-especially eutrophication-in some reservoirs become a socialaffair. Therefore, water quality control in these resources should be considered more intensively than any other environmental preservation policies. It also seems to be imminent to prepare the precautionary steps. Most water pollution in Korea-73 percent - can be traced to domestic sewage. It may rome as a surprise to Some, Industry is responsible for just 27 percent of ]Korea's water pollution. What he calls 'non-point' Sources, which may include agricultural Chemicals, Create only negligible amount of water pollution. Up to $15\%$ of domestic sewage is treated in Korea, which is quite low when compared with the waste processing in developed countries. So it is the most urgent matter to control the pollution sources. One of the precautionary plans, more urban domestic sewage treatment plants must be installed and operated efficiently. It is known that nutrients such as nitrogen and phosphorous are the major factors the process of eutrophication, which can be removed majorly by the tertiary or advanced treatment process.

  • PDF

Solar Inverter with Grid Power Generation

  • Suchitra Khoje;Govind Wanje;Ramesh Mali
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.9
    • /
    • pp.162-165
    • /
    • 2023
  • Power can be generated from either renewable or non-renewable sources. Renewable sources are liked to maintain a strategic distance from contamination emanation and rely on upon fossil energizes which is decreasing day by day. The proposed sun powered vitality transformation unit comprises of a sun oriented exhibit, Bidirectional DC-DC converter, single stage inverter and AC. The inverter changes over DC control from the PV board into AC power and offered it to the heap which is associated with the lattice. The photovoltaic sun powered vitality (PV) is the most direct approach to change over sunlight based radiation into power and depends on the photovoltaic impact. The most extreme power point following of the PV yield for all daylight conditions is a key to keep the yield control per unit cost low for fruitful PV applications. Framework associated PV frameworks dependably have an association with people in general power matrix by means of an appropriate inverter in light of the fact that a PV module conveys just dc power. This project presents the new design, Development and Performance Analysis of a Grid Connected PV Inverter. Demonstrate that the proposed framework can lessen the Energy Consumption radically from the power board and give a solid support to the Grid.

Prioritizing subwatersheds for non-point source pollution management in Saemangeum watershed using AHP technique (AHP 기법을 이용한 새만금유역의 비점오염원 우선관리지구 선정)

  • Woo, Hye-Jin;Jang, Taeil;Choi, Jin-Kyu;Son, Jae-Kwon
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.3
    • /
    • pp.101-112
    • /
    • 2015
  • The objective of this study was to investigate non-point sources (NPS) pollution and prioritize management areas affected by NPS pollution in the Saemangeum Watershed. AHP (Analytical Hierarchy Process) technique was selected to prioritize sub-watersheds for effectively managing NPS pollution in this study areas. Generation properties of NPS pollution, discharge properties of NPS pollution, and runoff properties of NPS pollution were selected and set for AHP. Weighted descriptors including indicators like numbers of livestock, land- and livestock-system loads, rainfall, and impervious area ratio were generalized from 0 to 1 and multiply each index based on screened 17 survey data. The results were visualized as maps which enable resource managers to identify sub-watersheds for effective improving water quality. The sub-watersheds located in Gongdeok-Myeon, Yongji-Myeon, Hwangsan-Myeon of Gimje-Si were selected for managing NPS pollution control areas. This result presented that these sub-watershed are more affected by the pollution from livestock-system than from land-system. The finding from this study can be used to screen sub-watersheds that need further assessment by managers and decision-makers within the study area.

A Study on Applicability of SUSTAIN in a Korean Urban Catchment (우리나라 도시배수분구에서의 SUSTAIN 적용가능성 연구)

  • Lee, Jeonghoon;Park, Yoonkyung;Shin, Hyun-Suk;Kim, Jeongsook;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.730-738
    • /
    • 2013
  • In recent years, low impact development (LID) has emerged as an effective approach to control stormwater in an urban area, and watershed and stormwater managers need modeling tools to evaluate alternative plans for controlling stormwater. This study illustrates how to design and evaluate the effect of non-point pollutant management using SUSTAIN which is developed by USEPA. SUSTAIN can provide evaluating, selecting, and placing LID facilities in an urban catchment based on user-defined cost-effectiveness criteria. Also, this paper suggests a minimal methodology for estimating model parameters for modeling an ungauged urban catchment to reflect the situation of typical Korean urban interested catchments which are usually ungauged. In addition, the optimal length of various LID facilities and the optimal number of units in our test catchment are estimated.

Flexure hinge mechanism having amplified rectilinear motion for confocal scanning microscopy using optical section

  • Kwon, Oh-Kyu;Park, Poo-Gyeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.162.6-162
    • /
    • 2001
  • Confocal scanning microscopy (CSM) is an important instrument in a wide variety of imaging applications because of its ability to provide three-dimensional images of thick, volume specimens. The mechanism for two-dimensional beam scanning and optical sectioning has an important roe in CSM as the three-dimensional profiler. This optical sectioning property arises from the use of a point detector, which serves to attenuate the signals from out-of-focus. The intensity profile for the open loop scanning should be matched with its response for the standard. The non-linearity can be minimized with the optical sectioning or the optical probe of the closed loop control. This paper shows the mathematical expression of the light such as the extinction curve in the optical fields of system using AO deflector, the axial/lateral response experimentally when the error sources change, and the methods of optical sectioning. Thorough design of optical sectioner is crucial to the success of CSM in the field ...

  • PDF

A study on the Management of Non-point Source Using Peak Water Quality Concentration (첨두수질농도를 이용한 비점오염원 관리방안 연구)

  • Kal, Byungseok;Park, Jaebeom;Kwon, Heongak;Im, Taehyo;Lee, Jiho
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.287-295
    • /
    • 2017
  • In this study, rainfall runoff characteristics according to peak concentration were analyzed using the water quality and flow data in the Geumho river, and the direction of nonpoint source management such as monitoring and management period by pollution source was derived. Peak Water Quality Concentration is the concept that utilizes the extreme value as the concentration of non-point pollution control standard with the highest water quality in the rainwater runoff. Using this method, the evaluation factors such as cumulative precipitation(total precipitation), peak water quality concentration, cumulative precipitation up to peak water quality concentration, time to peak water quality concentration, and EMC to peak water quality concentration were examined and long- Rainfall runoff characteristics of nonpoint sources were analyzed. The results of the analysis suggested proper monitoring and management method to manage nonpoint source.