Estimation of current and future loading from watershed is necessary for the sound management of water quality of an estuary lake. Pollution sources of point and non-point source pollution were surveyed and Identified for the Koheung watershed. Unit factor method was used to estimate potential pollutant load from the watershed of current conditions. Flow rate and water qualify of base flow and storm-runoff were monitored in the main streams of the watershed. Estimation of runoff pollutant loading from the watershed into the lake in current conditions was conducted by GWLF model after calibration using observed data. Prospective pollutant loading from the reclaimed paddy fields under cultivation conditions was estimated using the modified CREAMS model. As a result, changes of pollutant loading into estuary lake according to non-cultivation and cultivation conditions of reclaimed tidal land were estimated.
Urban stormwater runoff is the one of the most extensive causes of deterioration of water quality in streams in urban areas. Especially, in the Suyeong River watershed, non-point sources from urban-residential areas are the most common cause of water pollution. Also, it has been ascertained that BOD and COD as indexes of organic matter, have limitation on management of Suyeong River's water quality. In this study, changes of organic matter properties of Suyeong River from inflow of non-point source during rainfall were investigated. Fractions of organic matters were analyzed using water samples collected at two sites (Suyeong River and Oncheon Stream) during a rain event. Variations of dissolved organic carbon (DOC) concentration by rainfall were similar to flow rate change in the river. Distribution of organic matter fraction according to change of rain duration revealed that while hydrophilic component increased at initial rainfall, the hydrophobic component was similar to change in dissolved organic carbon (DOC) concentration. Also, the relative proportion of hydrophilic components in organic matter in river water increased, due to rainfall. Results of biodegradation of organic matters revealed that decomposition rate of organic matters during rainfall was higher than that of during a non-rainfall event.
본 연구에서는 비점오염원의 효율적인 관리방안을 확립하기 위하여 단위재배지로부터의 오염물질 배출특성을 조사하였다. 무강우일수가 상대적으로 길었던 약 20%의 강우사상을 제외한 나머지 강우사상에 대해서는 강우량과 강우에 의한 유출수량의 상관성은 상관계수 0.92로 매우 높았으며, 유출수량이 유출계수에 미치는 영향인자로는 유출직전의 강우강도가 주요인자임을 알 수 있었다. 한편, 유출수로부터 발생하는 오염물질의 EMCs(유량가중평균농도)가 높은 강우사상의 결과로 무강우일수가 길었던 강우사상에서 무강우에 의해 건조된 토양의 영향에 기인한 것임을 알 수 있다. 유출수로부터 발생되는 TSS, BOD, COD, TN 및 TP 등의 부하량은 동일한 강우사상에서 유사한 경향을 나타내므로 부유물질을 제어함으로써 다른 오염물질의 제거도 가능할 것으로 추정된다. 따라서 강우량계급별 유출계수 만을 이용한 오염물질부하량은 많은 오차를 나타낼 것이며, 오염부하 예측시스템을 개발할 때에는 강우량, 무강우일수, 선행강우량 등을 인자로 고려한 재배지토양조건을 충분히 고려하여야 할 것이다.
우리나라는 기상학적으로 연중 총강수량의 약 2/3가 6~9월에 편중해서 내리고 있고, 지형적으로 국토의 70% 이상이 산지로 구성되어 경사가급해 수해를 입을 가능성이매우 크다. 또한 산업화 및 도시화로인해 불투수층의 증가로 강수량의 대부분이 직접유출로 기여해 강우초기에 노면상의 오염물질을 급속히 하천으로 이동시켜 오염을 가중시키고 있다. 특히 위락시설지역은 도시화에 따른 인구집중으로 지역민들에게 휴식공간 및 공원기능의 제공으로 비점오염원의 이동능력도 증가하여 수질관리가 절실히 필요하다. 따라서 본 연구는 위락시설지역의 비점오염원 유출특성분석을 위해 SOM(Self-Organizing Map) 이론을 도입하여 시험유역에서 측정된 유출 및 BOD, TOC자료에 대해 패턴분류를 수행하여 분할구역별 자료의 특성을 분석하였다. 그 결과 BOD 농도는 4개 TOC 농도는 각각 4개, 6개 분할구역으로 구분되었으며 BOD 농도의 경우 Cluster1과 Cluster2가 TOC 농도의 경우 Cluster4와 Cluster5가 비점오염원 유출 연구에 있어서 매우 중요한 요소인 초기강우 양상을 나타내었다. 또한 유출량 자료 수집과정에서 불가피하게 발생하는 이상치 자료를 정상적으로 측정된 수위와 유출량관계를 통해 추정된 회귀식을 이용하여 보완하여 이상치 자료를 활용하였다.
본 논문에서는 하천구역 내에서의 경작활동으로 인한 비점오염원 유출특성을 파악하기 위하여 팔당상수원보호구역의 경기도 광주시에 위치한 G지역(논, 비닐하우스)과 남양주시의 S지역(노지 밭)을 선정하여 강우 시 현장조사를 수행하였다. 담수기능을 갖는 논은 강우강도에 따라 유출유량이 완만한 증감을 나타내어 제내지에 위치한 논의 유출특성과 유사한 현상을 보여주었다. 그러나 비닐하우스와 노지 밭 모두 강우강도에 비례하여 유출유량이 급격히 증가하는 현상을 보여주었다. 논, 비닐하우스 및 노지 밭의 BOD 평균 유출농도는 각각 2.0 mg/L, 2.8 mg/L, 7.9 mg/L로서 노지 밭의 유출농도가 높게 나타났으며, 강우사상에 따른 토양의 유출에 기인하여 SS, T-N 및 T-P 유출농도도 노지 밭이 가장 높은 것으로 조사되었다. 경작지별 배출부하량을 산정한 결과, 논의 T-N 배출부하량이 1,793.9 kg/year으로 밭에 비해 높게 나타났으며, 노지 밭의 SS 배출부하량은 69,704 kg/year로 전체 배출부하량의 70% 이상을 차지하는 것으로 산정되었다.
강우 시, 건설 현장 내에서 발생하는 비점오염원의 경우 타 오염 물질 대비 부유 물질 부하량이 매우 높게 나타나며 강우 강도에 대한 민감도가 공사 초반의 경우 매우 높게 나타난다. 이러한 비점오염원을 저감할 수 있는 시설로 가설형 비점오염원 처리 시설과 여과형 처리 시설이 있다. 가설형 시설의 경우 전반적으로 비점오염원에 대한 저감 효율이 제한적이며, 여과형 처리 시설의 경우 동력의 소모가 높고, 공간적 효율성이 다소 떨어진다는 단점이 있다. 따라서, 본 연구에서는 기존의 비점오염원 처리 시설의 단점을 해소하고 보다 높은 비점오염원 처리 효율을 확보하기 위해 조립식 응집 침전 시스템을 개발하여 현장에 적용하여 비점오염원 처리 특성을 평가하고자 하였다. 조립식 응집 침전 시스템의 경우 가설 형식이나 여과형 처리 시설 대비 매우 높은 처리 효율을 나타내며, 공간적 효율성이 매우 높은 것으로 나타나 비점오염원 발생 인근 지역의 수계 오염 방지 및 민원 발생 방지 효과가 있을 것으로 기대할 수 있었다. 이러한 조립식 응집 침전 시설의 현장 적용 시, 최적의 비점오염원 저감 효과를 확보하기 위해서는 발생 비점오염원의 농도에 따라 적정 응집제 주입량 산정 및 슬러지 순환 시설의 적용 및 지속적인 유지 관리를 통한 침전 슬러지의 계면 높이 조절이 반드시 필요하다.
Activities on golf courses are believed to contribute to the degradation of water quality in receiving waters due to the excessive use of farm chemicals including fertilizers and pesticides. The objective of this study was to collect basic data that could explain the characteristics of non-point source (NPS) pollution discharged from a golf course. Twenty seven water quality monitoring was conducted at a golf course during the rainy season of 2008 and 2009. The results indicated that the ranges of the Event Mean Concentration (EMC) at the golf course were $BOD_5$ 1.8~11.3 (ave. 5.6) mg/L, $COD_{Mn}$ 19.2~51.4 (ave. 39.6) mg/L, TOC 11.0~31.0 (ave. 16.8) mg/L, TN 1.545~16.098 (ave. 5.623) mg/L, TP 0.230~4.528 (ave. 1.525) mg/L, and SS 2.2~57.3 (ave. 10.1) mg/L. The unit loads of the golf course estimated were $BOD_5$$3.35kg/km^2/day$, SS $6.43kg/km^2/day$, $COD_{Mn}$$30.00kg/km^2/day$, TN $4.04kg/km^2/day$, TP $1.14kg/km^2/day$, and TOC $12.16kg/km^2/day$. Golf courses are currently classified as a grass field in which the unit loads are different from golf courses. Therefore, it was recommended that golf courses need to be separated from the grass field when the surveys and modelings for Total Maximum Daily Load (TMDL) development and the evaluation of TMDL implementation were performed.
The Ministry of Environment (MOE) has made more effort in managing point source pollution rather than in nonpoint source pollution in order to improve water quality of the four major rivers. However, it would be difficult to meet water quality targets solely by managing the point source pollution. As a result of the comprehensive measures established in 2004 under the leadership of the Prime Minister's Office, a variety of policies such as the designation of control areas to manage nonpoint source pollution are now in place. Various action plans to manage nonpoint source pollution have been implemented in the Soyang-dam watershed as one of the control areas designed in 2007. However, there are no tools to comprehensively assess the effectiveness of the action plans. Therefore, this study would assess the action plans (especially, BMPs) designed to manage Soyang-dam watershed with the WinHSPF and the CE-QUAL-W2. To this end, we simulated the rainfall-runoff and the water quality (SS) of the watershed and the reservoir after conducting model calibration and the model validation. As the results of the calibration for the WinHSPF, the determination coefficient ($R^2$) for the flow (Q, $m^3/s$) was 0.87 and the $R^2$ for the SS was 0.78. As the results of the validation, the former was 0.78 and the latter was 0.67. The results seem to be acceptable. Similarly, the calibration results of the CE-QUAL-W2 showed that the RMSE for the water level was 1.08 and the RMSE for the SS was 1.11. The validation results(RMSE) of the water level was 1.86 and the SS was 1.86. Based on the daily simulation results, the water quality target (turbidity 50 NTU) was not exceeded for 2009~2011, as results of maximum turbidity in '09, '10, and '11 were 3.1, 2.5, 5.6 NTU, respectively. The maximum turbidity in the years with the maximum, the minimum, and the average of yearly precipitation (1982~2011) were 15.5, 7.8, and 9.0, respectively, and therefore the water quality target was satisfied. It was discharged high turbidity at Inbuk, Gaa, Naerin, Gwidun, Woogak, Jeongja watershed resulting of the maximum turbidity by sub-basins in 3years(2009~2011). The results indicated that the water quality target for the nonpoint source pollution management should be changed and management area should be adjusted and reduced.
In this study, the characteristics of nonpoint source pollutant loads from separate sewer overflow (SSO) and combined sewer overflow (CSO) were evaluated during 2016 in Namyangju city, Korea. Five rainfall events were monitored during 2016 with ranging from 14.5 mm to 121.5 mm. The runoff ratio of CSO was higher than that of SSO because only design volume of maximum sanitary sewer ($1Q_h$) was transported and treated and $2Q_h$ was overflowed to waterbody during rainy day although combined sewer system was designed to transport $3Q_h$ to treatment system. The event mean concentrations (EMCs) and pollutant loads from CSO were higher than those from SSO. BOD and COD of CSO, and TOC and TN of SSO represented distinct first flush phenomena. The inadequate management in combined sewer system from which the untreated $2Q_h$ from CSO was overflowed to waterbody during rainy day could influence on high pollutant loads and first flushing. Treating $2Q_h$ from CSO, source control such as low impact development, and treating outflow from SSO were strongly recommended to control non-point source pollution in urban area.
본 연구에서는 대청호 상류에 위치한 소옥천을 대상으로 유역 및 오염원 특성을 조사하여 각 특성별 지수를 분석하고 취약지역을 분석하였다. 다양한 유역 및 오염원 자료를 지수화하기 위하여 표준화법인 Dimension Index법을 적용하였으며 선정된 지수와 수질모니터링 자료와의 상관성 분석을 통해 각 오염원별 영향인자를 도출하였다. 오염원별 영향인자에 미치는 특성들은 각각의 유의성에 차이가 있었으며 BOD와 COD는 인구밀도와 대지면적 비율, T-N은 CN과 논면적 비율, T-P는 인구밀도와 대지면적 비율에서 유의한 영향이 있는 것으로 검토되었다. 오염원별 영향인자로 판단된 지수를 이용하여 취약지역 우선순위를 산정하였고 배출부하량을 고려하여 산정된 취약지역과 순위를 비교 검토하였다. 배출부하량은 비점오염 대책 수립시 많이 사용되고 있으나 호소나 하천에 유입되는 유달부하량과 차이가 있어 수질 모니터링 자료와의 상관성 분석시 수질과 유의미한 값이 낮게 나타났다. 따라서 효율적인 비점오염 관리를 위해서는 취약지역 선정과 함께 수질과 상관성 높은 영향인자를 분석하고 해당 인자에 대한 관리가 우선으로 필요할 것으로 판단된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.