• Title/Summary/Keyword: Non-occupational exposure

검색결과 194건 처리시간 0.019초

퇴직한 납 취급 근로자들에서 골밀도 저하와 경골납량이 혈중납량에 미치는 영향 (Effect of Bone Demineralization and Tibia Lead on Blood Lead in Retired Lead Workers)

  • 김남수;김진호;김화성;김희선;이성수;;이병국
    • 한국산업보건학회지
    • /
    • 제16권4호
    • /
    • pp.324-333
    • /
    • 2006
  • This study was designed to investigate the effect of bone demineralization and tibia lead on blood lead in retired lead workers. Two hundred thirty five(126 females and 109 males) retired lead workers who worked in 4 different lead factories and 101 non-occupationally lead exposed subjects(51 females and 51 males) were recruited from March 2004 to October 2004. Bone mineral density(BMD) was measured at left calcaneous bone area by broadband ultrasound attenuation(BUA) method with QUS-2(Metra Biosystems Inc, USA). The BUA value transformed into T-score by WHO standard conversion criteria. Tibia bone lead was measured for skeletal bone lead with K-xray fluorescence(K-XRF) and blood lead was analyzed with flameless atomic spectrophotometer. Hemoglobin, hematocrit, serum calcium and iron were also analyzed. In addition, information for smoking and drinking status and basic personal data such as age, gender and lead exposure were also collected using questionnaire inquiry. Blood lead was correlated with tibia lead (r=0.664) and these two variables were negatively correlated with BMD in bivariate analysis. BMD showed significant main effect on the change of blood lead independent to tibia lead without any effect modification of age or gender; the one T-score unit decrease of mineral bone density made $0.43{\mu}g/dl$ increase of blood lead. On the other hand, tibia lead showed effect modification with gender on blood lead; the slope of tibia lead on blood lead in male was steeper than in female and crossed at around zero of tibia lead. In the multiple regression analysis of blood lead and tibia lead on BMD after adjustment of related covariates, only blood lead showed statistically significant effect on BMD. This study confirmed that BMD and blood lead were significantly associated. To verify the causal association of BMD on blood lead and vice versa, further longitudinal studies are needed.

7H-Dibenzo [c,g] carbazole과 Dibenz[a,j] acridine에 의한 DNA adduct의 32P-postlabeling 분석 (32P-postlabeling Analysis of 7H-Dibenzo [c,g] carbazole and Dibenz [a,j] acridine DNA Adduct in Mice)

  • 노재훈;문영한;데이비드 봐르쇼브스키;글렌 탈라스카
    • 한국산업보건학회지
    • /
    • 제3권1호
    • /
    • pp.14-21
    • /
    • 1993
  • 7H-dibenzo[c,g]carbazole(DBC)과 dibenz[a, j]acridine(DBA) 및 이의 대사물 trans-DBA-1,2-dihydrodiol(DBA-1,2-DHD), trans-DBA-3,4-dihydrodiol(DBA-3,4-DHD), trans-DBA-5,6-dihydrodiol(DBA-5,6-DHD)]에 의한 DNA adduct형성을 알기 위해 Hsd:ISR 생쥐 피부에 이를 투여하고 용매 추출법으로 DNA를 분리하고 $^{32}P$-postlabeling법으로 DNA adduct를 분석하였다. DBC를 피부에 투여하여 DNA adduct가 국소작용 부위인 피부와 내장기관인 간, 폐 및 신장에 형성되어 DBC는 국소 및 전신 발암작용이 있음을 알 수 있었다. 또한 DNA adduct활성도가 간에서는 높고 피부, 폐, 신장에서는 상대적으로 낮아 DBC에 의한 발암의 주 표적 장기는 간임을 추측할 수 있었다. DBA, DBA-3,4-DHD 및 DBA-5,6-DHD 투여에 의해 두개의 adduct가 피부에서 관찰되었다. 대사 물질인 DBA-5,6-DHD에 의해 2개의 adduct가 형성되었으나 그 양상이 DBA 및 DBA-3,4-DHD와는 달랐으며 DBA-1,2-DHD에 의해서는 DNA adduct 형성이 관찰되지 않았다. 이상의 결과로 DBA는 국소발암작용이 있으며 활성 대사물인 DBA-3,4-DHD가 최종 발암원(ultimate carcinogen)이고 DBA-1,2-DHD는 무독화 대사물질로 추측된다.

  • PDF

사무 자동화에 따른 사무직 근로자의 건강과 연관된 자각 증상에 대한 조사연구 (An Investigation on the self-consciousness Symptoms of the Clerical Workers attendant upon Office Automation)

  • 정미화
    • 한국직업건강간호학회지
    • /
    • 제3권호
    • /
    • pp.54-70
    • /
    • 1993
  • According as the automation of clerical work(OA ; Office Automation) develops, the use of VDT(Visual or Video Display Terminal) is increasing suddenly. But, in proportion to the spread of office automation(OA tendency), the self-conciousness syptom attendant upon the work is appearing also (Kim, Jung Tae, Lee, Young Ook, 1990). The apparatuses of office enable the clerical workers to be convenient and perform mass businesses. But, they are increasing the opportunity to be exposed to VDT syndrom, techno stress, computer terminal disease, pain by muscle strain(RSI), bradycausia of noise nature, and electromagnetic waves, etc. which are referred to as the new type of occupational diseases to the workers. It is the real situation that the workers to use VDT is complaining of the physical inconvenience sense in the recent newspaper and literature, it is the point of time that the sydrome to come from VDT use and computer terminal disease, etc. must be classified into the occupational disease(Lee, Kwang Young 1990, Lee, Kyoo Hak 1990, Lee, Won Ho 1991, Lee, Si Young 1991, Lee, Joon 1991, Choi, Young Tae 1991, Heo, Seung Ho 1989). In addition, it is the real situation that the scientifitic study result about the scope that electromagnetic waves has influence on the human body has not been suggested yet, and criticism on the stable exposure permission standard about electromagnetic waves to be emitted from VDT and on the problem in the health about electromagnetic waves is continuing. (IEEE Spectrum, 1990). In addition according to the experience of nursery business of industry field, it is the real situation that the patients who consult complaining of physical and mental inconvenience sence, among the users of apparatus of office automation, are reaching 10% of the patients coming to doctor's room. Therefore, it is necessary to confirm the self-consciousness symptom that the clerical workers complain of multilaterally with the actual state examination about the use of the apparatuses of offices automaton. Thus, this study was tried as th basic data for the cosultation and education for the maintenance and furtherance of the health of workers as the nurse of industry field, by confirming the contents of self-consciousness symptom attendant upon the use of the apparatus for office outomation making the financial institution in which the spparatus for office automation in most frequently used as the subject, and by examining whether there is the difference according to the subject of study, the data were collected, by using the questionnaire method, making 200 workers who consented to the study participation as the subject, among the persons who have spent over 3 months since they used the apparatuses for office automation and didn't receive the treatment in hospital due to the clerical disease for recent 3 years. The period of data collection was from Oct. 9, 1991 to Oct. 12. As for the measurement instrument about the complaint if self-consciousness symptom attendant upon the use of apparatuses fo office automation, the question item on the complaint symptom of health problem attendant upon the treatment of VDT that Kim(1991) developed and on CMI health problem and the question items on the fatigue degree due to industry were used by previous examination to 25 persons. Collected data were analyzed with the statistical method such as percentage, arithmetic mean, Person correlation coeffient, Kai square verfication, t-test, ANOVA, etc. by using SPSS/PC+ program, and the result is as follows : 1. The self-consciousness symptom that the clerical workers complained of most frequetly appeared high in 'My eyes are tired'(99.4%), 'I feel fatigue and weariness'(99.4%), 'I feel that my head is heavy5(90.0%), 'eyesight fell'(88.8%), 'I have a stiff neck'(88.8%), 'I fell pain in the shoulder'(85.0%), 'I feel cold and painful in the eyes'(76.9%), 'I feel the dry sense of eyeball'(76.2%), 'My nerves are edgy, and I an fretful, (75.6%), 'I feel pain in the waist'(73.2%) and 'I fell pain in the back'(72.8%). It emerged that the subject use the apparatuses for office automation complained of self-consciousness symptoms related to visual symptoms and musculoskeletal symptoms. 2. As for the general feature of examination subjects, the result to see the distribution by classifying into sex, age, school career, use career of apparatuses for office automation, skillfulness degree of the use of apparatus for office automation, use hours of the apparatuses for office automation per 1 day, type of business of the apparatus for office automation, rest hours during the use of apparatus for office automation, satifaction degree of business of office automation, and work circumstance, etc. emerged as follows : As for the sex of subjects, the distribution showed that men were 58.8% and women were 41.3%, Age was average 26.9. As the distribution of school career, the distribution showed that4below the graduation of high school' was 58.8%, 'graduation from junior college-university' was 35.0%, and 'over graduate school' was 6.3%. In the question to ask the existence or non-existence of experience of health consultation in connection with the work of office automation, the response that I had the consultation exprience and I feel the necessity emergerd as 90.1% And, the case that the subject who didn't wear the glasses or lens before using the OA apparatus wear glasses or lens after using OA apparatus emerged as 28.3% of whole. As for the existence or non-existence of use career of OA apparatus, the case under 3 years was highest as 52. 7%. As for the skillfulnness degree about the use of apparatus for office automation, most of them are skillful with the fact that 'common' was 44.4%, 'skill' was 42.5%, and 'unskillful' was 13.1% As for the use average hours of the apparatus for office automation per 1 day, the distribution showed that the case under 3-6 hours was 33.1%, the case under 6-9 hours was 28.1%, the case under 3 hours was 30.6%, and the case over 9 hours was 8.1% Main OA business and the use hours for 1 day showed in the order of keeping and retrieval, business of information transmission(162min), business of information transmission(79.3 min), business of document framing(55.5 min), and business of duplication and printing(25.4min). as for the rest during the use of apparatus for affice automation, that I take rest occasion demands the major portion, but that I take after completing the work emerged as 33.8%. Though the subiness gets to be convenient by the use of the apparatus for of office automation, respondents who showed the dissatisfaction about the present OA business emergd high as 78.1%. The work circumstances of each office was good with the fact that the temperature of office was 21.8, noise was average 42.7db, and the illumination was average 364.4 lx, in the light of ANSi/HFS 100 Standard. 3. Sight syptom, musculoskeletal symptom, skin and other symptoms showed the significant difference according to the extent of skillfulness of the apparatus for office automation. All the symptoms exept skin symptom showed the difference according to the use hours of the apparatus for office automation. All the question items exept the sytoms of digestive organs and the rest hours during the apparatus for office automation showed the signicant difference. The question item which showed the signicant difference from the satisfaction degree of present OA business showed the significant difference from all the question item classified into 6 groups. But, age and school career didn't significant difference from the complaint of any self-consciousness symptoms.

    . In conclusion, the self-consciousness symptoms of the subjects to use OA apparatus appeared differently, according to sex distiction, skillfull degree of OA apparatus, use hours of OA apparatus, the rest hours during th use of OA apparatus, and the satiafaction degree of persent business. Therefore, it is necessary that the nurse in the inuctry field must recognize to receive the education about the human technological physical condition which is most proper for te use of OA apparatus and about the proper rest method until they get accustomed to the use of OA apparatus. In addition, the simple exercise relax the tention of muscle due to the repetitive simple movement, and the education for the protection of eyesight are necessary.

  • PDF
  • 크롬 취급 사업장의 작업환경 및 근로자 폭로 실태에 관한 연구 (A Study of Working Environments and Workers Exposed to Chromium)

    • 유병철;손병철;전진호;손혜숙;한용수;이채언;정운
      • Journal of Preventive Medicine and Public Health
      • /
      • 제27권3호
      • /
      • pp.517-530
      • /
      • 1994
    • For the purpose of providing the basic data for health management of workers who are exposed to chromium and for improving the quality of working environment, the authors evaluated blood and urinary level of chromium, the occupational history. AST, ALT, Hb, Hct, nasal specular examinaton on 287 workers who have been dealed chromium compounds in 56 manufacturing Industries of five types, that is, 38 metal plating services(plating),4 manufacture of other fabricated metal products (fabricated metal product), 5 manufacturing of dyestuff(dyestuff), 6 dressing and dyeing of leather(leather), 3 others(manufacture of pottery and ceramic househod wares, motor vehicles, electronic valves and tubes and other electronic components) and also measured the level of chromium in air from February to October 1993. The results were as follows ; 1. The utilized type of chromium compounds was the hexavalent state in plating fabricated metal product dyestuff, leather and the trivalent state in .other, and atmosperic chromium concentration as geometric mean was $0.0138mg/m^3(0.001{\sim}0.068mg/m^3)$ in plating, $0.0115mg/m^3(0.006{\sim}0.015mg/m^3)$ in fabricated matal product, $0.068mg/m^3(0.002{\sim}0.019mg/m^3)$ in dyestuff, $0.0083mg/m^3(0.002{\sim}0.028mg/m^3)$ in leather $0.0039mg/m^3(0.003{\sim}0.005mg/m^3)$ in other by the type of industry and it exceeded TLV-TWA ($0.05mg/m^3$) in five (13.6%) of plating services. 2. The geometric mean of chromium in blood was $1.54{\mu}g/dl(0.10{\sim}3.62{\mu}g/dl)$ in Plantng, $0.94{\mu}g/dl(0.27{\sim}2.82{\mu}g/dl)$ in fabricated metal product, $0.51{\mu}g/dl(0.10{\sim}3.25{\mu}g/dl)$ in dyestuff, $0.87{\mu}g/dl(0.15{\sim}8.00{\mu}g/dl)$ in leather, $0.55{\mu}g/dl(0.20{\sim}2.28{\mu}g/dl)$ in other by the type of industry(p<0.001). 3. The geometric mean of chromium in urine was $14.47{\mu}g/l(6.90{\sim}28.00{\mu}g/l)$ in planting, $4.63{\mu}g/l(0.24{\sim}43.00{\mu}g/l)$ in fabricated metal product, $5.93{\mu}g/l(1.00{\sim}33.00{\mu}g/l)$ in dyestuff, $11.09{\mu}g/l(0.80{\sim}48.00{\mu}g/l)$ in leather, $12.41{\mu}g/l(10.10{\sim}41.00{\mu}g/l)$ in other by the type of industry(p<0.001). 4. As the result of nasal specular examination, twenty four cases (8.4%) of nasal septal perforation among 287 total subjects was observed, and there were 17 (9.7%) cases in plating, 4 csaes (14.3%) in dressing and dyeing of leather. In the comparison of chromium concentration in blood and urine between the perforated group and non-perforated group, the perforated group showed a significantly higher value as $1.883{\pm}3.055{\mu}g/dl\;and\;0.793{\pm}0.815{\mu}g/dl$(P<0.001), $21.31{\pm}34.610{\mu}g/L\;and\;9.304{\pm}11.079{\mu}g/L$ (P<0.001). 5. The mean concentration of chromium in blood, urine and the mean level of AST, ALT, Hb and Hct in exposure group were higher than those of control group(p<0.001).

    • PDF