• Title/Summary/Keyword: Non-linear corrosion

Search Result 32, Processing Time 0.035 seconds

Mathematical Modeling on the Corrosion Behavior of the Steel Casing and Pipe in Cathodic Protection System (음극방식 시스템에서의 압입관과 배관의 부식거동에 관한 수학적 모델링)

  • Kim Y.S.;Li S.Y.;Park K.W.;Jeon K.S.;Kho Y.T.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.40-46
    • /
    • 1998
  • Mathematical modeling on the corrosion of the steel casing and main pipe due to the protection current resulting from a cathodic protection system was carried out using boundary element method. The model is consisted of Laplace's equation with non-linear boundary conditions(Tafel equations) and the iterative technique to determine the miexed potential of the steel casing. The model is applied to the normal steel casing section as well as abnormal one with defects such as metal touch and insulation defects. From the modeling procedure, we can calculate the potential distributions and current density distributions of the system. The theoretical results of the qualitatiive corrosion aspect along the steel casing and main pipe agree well with the experimental results within the experimental conditions studied.

  • PDF

The Comparison of the Heat Distribution and Characteristic between the Laser & SMAW Welds of 9Cr-lMo Steel. (9Cr-lMo강에 대한 Laser 및 SMAW 용접부의 열분포 특성 비교)

  • O Jong In;Bang Han Seo;Kim Yeong Pyo;Park Hyeong Geun
    • Proceedings of the KWS Conference
    • /
    • v.43
    • /
    • pp.118-120
    • /
    • 2004
  • Recently 9Cr-1Mo azzoy is used in the Nuclear power plant due to its special properties. This material has the merit of high-strength resistance and corrosion resistance. Therefore the demand for this alloy is dramatically increased in the Nuclear power, petro-chemical complex etc. Re various research has been conducted to improve the material properties of this alloy. In spite of this circumstance, detail research in the area of welding process of this alloy is yet to be expanded In this study the numerical non-linear heat transfer analysis of laser welding which may possibly replace the conventional SMAW fabrication of 9Cr-1Mo steel has been carried out.

  • PDF

Study on the Reinforced Method of Doubler Plate in Ship Hull Structure (선박 이중판의 보강법 연구)

  • 함주혁
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.144-149
    • /
    • 2001
  • A study for the structural strength analysis on the doubler plate subjected to the axial, biaxial in-plane compression and shear load has been performed through the systematic evaluation process. In order to estimate the proper static strength of doubler plate, non-linear elasto-plastic analysis is introduced. Gap element modeling for contact effect between main plate and doubler is prepared and nonlinear analysis procedures are illustrated based on MSC/N4W . In addition, some design guides are suggested through the consideration of several important effects such as corrosion of main plate, doubler width, doubler length and doubler thickness. Finally theses results are compared with developed design formula based on the buckling strength and general trends and design guides according to the variation of design parameters are discussed.

  • PDF

Strength Evaluation of a Doubler Plate of a Ship S011c111re subjected to Biaxial In-plane Compression and Shear Load (양축방향 면내압축과 전단하중을 받는 선박 이중판의 강도 평가)

  • 함주혁
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.1
    • /
    • pp.85-91
    • /
    • 2001
  • A study for the structural strength analysis on the doubler plate subjected biaxial in-plane compression and shear load has been performed through the systematic evaluation process. In order to estimate the proper static strength of the doubler plate, non-linear elasto-plastic analysis is introduced. Gap element modeling for contact effect between the main plate and the doubler is prepared and nonlinear analysis procedures are illustrated based on MSC/N4W. In addition, some design guides are suggested through the consideration of several important effects such as corrosion of main plate, doubler width, doubler length and doubler thickness. Finally, theses result are compared with a developed design formula based on the buckling strength and general trends. The design guides, according to the variation of design parameters are discussed.

  • PDF

Determination of Dynamic Free Span Length for Subsea Pipelines with General Boundary Conditions (일반화된 경계조건을 갖는 해저파이프라인의 동적 자유경간 결정 방법)

  • 박한일
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.4
    • /
    • pp.290-295
    • /
    • 2001
  • Subsets pipelines are exposed to several potential risks of damage due to corrosion, soil instability, anchor impact and other hazards. One of the main risk factors for the safety of a subsea pipeline is its free spanning. This paper examines the safety of subsea pipelines with free span under axial compressive load. The variation of allowable lengths of dynamic free span is examined for generalized boundary conditions. The free span is modelled as a beam with an elastic foundations and the boundary condition is replaced by linear and rotational springs at each end. A dynamic free span curve is obtained with a function of non-dimensional parameters and can be used usefully for the design of subsea pipelines with a free span. A case study is carried out to introduce the application method of the curve.

  • PDF

Shear response of lean duplex stainless steel plate girders

  • Armoosh, Salam R.;Khalim, A.R.;Mahmood, Akram Sh.
    • Structural Engineering and Mechanics
    • /
    • v.54 no.6
    • /
    • pp.1267-1281
    • /
    • 2015
  • Carbon steel plate girders have been used on a large scale in the building industry. Nowadays, Lean Duplex Stainless Steel (LDSS) plate girders are gaining popularity as they possess greater strength and are more impervious to corrosion than those that are constructed from carbon steel. Regardless of their popularity, there is very limited information with regards to their shear behavior. In this paper, the non-linear finite element analysis was employed to investigate the shear behavior of LDSS plate girders. Parameters considered were the web thickness, the flange width, and the girders aspect ratio. The analysis revealed that although the shear behavior of the LDSS girders was no different from that of carbon steel plate girders, it had obviously been affected by the non-linearity of the material. Furthermore, the selected parameters were found to pronounce effect on the shear capacity of the LDSS girders. That is, the shear capacity increased considerably with web thickness, and increased slightly with flange width. However, it was reduced as the aspect ratio increased. Comparisons between the finite element analysis failure loads and those predicted by the current European Code of Practice revealed that the latter underestimated the shear strength of the LDSS plate girders.

Technical Application and Analysis for Reduction of Water Loss in Water Distribution Systems (상수도 관망의 유수율 제고 기술의 적용 및 분석)

  • Kim, Ju-Hwan;Lee, Doo-Jin;Bae, Cheol-Ho;Woo, Hyung-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.260-266
    • /
    • 2009
  • Non-revenue water reduction(NRW) technologies are implemented to evaluate and manage leakages scientifically in water distribution systems under local governments. A development of quantitative leakage indicator by measuring minimum night flow, pressure control policy by installation of PRV(pressure reducing valve) and the establishment of leakage prevention schemes by residual life modeling of deteriorated water pipes are reviewed and studied. Estimation models of allowable leakage are developed by measuring and analyzing minimum night flow at residential and commercial area in Nonsan city, which is suggested from UK water industry and can improve an existing leakage indicator for the evaluation of non-revenue water. Also, pressure control method is applied and analyzed to Uti distribution area in Sacheon city in the operation aspect. As results, $466\;m^3/day$ of leakage can be reduced and it is expected that 113million won of annual cost can be saved. In the part of corrosion velocity and residual life assessment, non-linear prediction models of residual thickness are proposed by assessment of corrosion velocity based on exposure years, soil and water quality etc., since the deteriorated water pipe play a major role to increase leakage. It is expected that collection data and analyzing results can be applied effectively and positively to reduce non-revenue water by accumulating surveying data and verifying the results in the business field of water distribution systems under local governments.

  • PDF

Development of Testing and Analysis Model for Evaluation of Absorbed Water Diffusion into Concrete (콘크리트 흡수 수분확산계수 산정을 위한 실험 및 수치해석 모델 개발)

  • Park, Dong-Cheon;Ahn, Jae-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.4
    • /
    • pp.371-378
    • /
    • 2011
  • Concrete is affected by various deterioration factors, such as $CO_2$ and chloride ions from the sea, which cause carbonation and salt attack on concrete. These deterioration phenomena cause steel corrosion in RC structures. Although a great deal of research has been carried out in this area thus far, it is difficult to know the point at which corrosion will occur to a reinforced bar. As the diffusion of deterioration factors depends on the water content in concrete, it is imperative to assess the condition of absorbed water content. A mass measuring method was applied to calculate the absorbed water diffusion coefficient, as well as non-linear finite element method(FEM) analysis. As a result, it was found that W/C and unit water content in concrete mixture affect the diffusion coefficient decision.

Characterization of Ni-Fe Alloy Electrodeposited Electrode for Alkaline Water Electrolysis (알칼라인 수전해용 Ni-Fe 합금 전착 전극의 특성)

  • AN, DA-SOL;BAE, KI-KWANG;PARK, CHU-SIK;KIM, CHANG-HEE;KANG, KOUNG-SOO;CHO, WON-CHUL;CHO, HYUN-SEOK;KIM, YOUNG-HO;JEONG, SEONG-UK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.6
    • /
    • pp.636-641
    • /
    • 2016
  • Alkaline water electrolysis is commercial hydrogen production technology. It is possible to operate MW scale plant. Because It used non-precious metal for electrode. But It has relatively low current density and low efficiency. In this study, research objective is development of anode for alkaline water electrolysis with low cost, high corrosion resistance and high efficiency. Stainless steel 316L (SUS 316L) was selected for a substrate of electrode. To improve corrosion resistance of substrate, Nickel (Ni) layer was electrodeposited on SUS 316L. Ni-Fe alloy was electrodeposited on the passivated Ni layer as active catalyst for oxygen evolution reaction(OER). We optimized preparation condition of Ni-Fe alloy electrodeposition by changing current density, electrodeposition time and composition ratio of Ni-Fe electrodeposition bath. This electrodes were electrochemically evaluated by using Linear sweep voltammetry (LSV) and Cyclic voltammetry (CV). The Ni-Fe alloy (Ni : Fe = 1 : 1) showed best activity of OER. The optimized electrode decreased overpotential about 40% at $100mA/cm^2$ compared with Ni anode.

Development of static and dynamic stability utilizing superior SUPER concrete 100MPa pontoon (정적 및 동적안전성이 우수한 SUPER concrete 100MPa 활용 부잔교 개발)

  • Lim, Hyoung Joo;Yun, Sik Jae;Lee, Sang Hee
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.135-136
    • /
    • 2016
  • SUPER concrete poontoon is developed to overcome shortcomings about corrosion problem of steel pontoon and the insufficient freeboard line of concrete pontoon. Top slab of Pontoon resists truck load or sidewalk live load. The soffit slab and outer wall of Pontoon resist the horizontal and vertical components of wave pressure, and those were loaded along X and Y-axis of Pontoon. Global analysis for the Pontoon is carried out to design its cross-sections economically using a geometric non-linear time history analysis method by Strand7 and buoyance-stability calculated automatically on non-vertical boundary conditions. And the load-capacity of Pontoon is confirmed through mock-up tests.

  • PDF