• Title/Summary/Keyword: Non-isolated

Search Result 1,591, Processing Time 0.044 seconds

Response spectrum analysis considering non-classical damping in the base-isolated benchmark building

  • Chen, Huating;Tan, Ping;Ma, Haitao;Zhou, Fulin
    • Structural Engineering and Mechanics
    • /
    • v.64 no.4
    • /
    • pp.473-485
    • /
    • 2017
  • An isolated building, composed of superstructure and isolation system which have very different damping properties, is typically non-classical damping system. This results in inapplicability of traditional response spectrum method for isolated buildings. A multidimensional response spectrum method based on complex mode superposition is herein introduced, which properly takes into account the non-classical damping feature in the structure and a new method is developed to estimate velocity spectra from the commonly used displacement or pseudo-acceleration spectra based on random vibration theory. The error of forced decoupling method, an approximated approach, is discussed in the viewpoint of energy transfer. From the base-isolated benchmark model, as a numerical example, application of the procedure is illustrated companying with comparison study of time-history method, forced decoupling method and the proposed method. The results show that the proposed method is valid, while forced decoupling approach can't reflect the characteristics of isolated buildings and may lead to insecurity of structures.

The Distribution of Serogroup of Vibrio cholerae non-O1 Isolated in Korea (한국에서 분리된 Vibrio cholerae non-O1의 혈청형의 분포)

  • 성희경
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.1
    • /
    • pp.13-17
    • /
    • 2003
  • The studies were carried out to identification of biochemical characteristics and serogroup of 55 Vibrio cholerae non-01 isolated from sea waters and shellfish from Apr., 1996 to Nov., 1996 in Korea coastal, and clinical sources from 1984 to 1996 in Korea hospitals. The results were as followed: V. cholerae non-O1 isolated 21 (10%) of 206 samples and the distribution in Kusan area was highest (16%) compared with those of other area, and its were not isolated during low water temperature of 13-18$^{\circ}C$. Of 55 strains, a strain was delayed sucrose utilization for 48hr in the biochemical characteristics. Fifty five V. cholerae non-O1 were differentiated 15 types by serogroup test and O14 of sea waters were 76% of highest followed by 14 clinical sources were O8.

Distribution of Virulence Factors of Vibrio cholerae non-O1 and non-O139 Isolated from Korea (한국에서 분리된 Vibrio cholerae serovar non-O1 및 non-O139 병독 인자의 분포)

  • 성희경
    • Korean Journal of Microbiology
    • /
    • v.35 no.3
    • /
    • pp.248-252
    • /
    • 1999
  • The PI-oduction of virulence factors such as cholera toxin, heinolysin and hemagglutinin in V cliolerae non-01 and non-0139 were examined. Among 65 strains isolated from environmental and clinical blood sources, 29 (14.6%) strains produced hemolysin only, 35(53.9%) sh.ains produced both hemolysin and hemagglutinin. From one 037 slrain isolated from environmenl, cholera toxin, ctx gene, hemolysin, and hemagglutinin were detected. All of the strains isolated from clinical and environmental sources showed hemolytic activity against human 0 group e~ythrocytes. In inhibition patterns of heinagglotination, 5 of 18 clinical strains (27.8%) were inhibited by less than 1% mannose and galactose, while, among the 47 environmental isolates. hose paltems by less than 1% mannose and galactose 55.4% wel-e inhibited. Thel-ehre, exohamagglutinin positive rate was high in clinical blood isolates but in environnlental sources, the rate was almost similar lo ihe rate or endohemagglutinin positive. These results indicaled that V cholerae non-01 and non-0139 produced various virnlence factors such as cholera toxin, hemolysin, and hemagglutinin but not a single factor. Further studies are need for epidemiological or bacteriological shtdies of V cholerae 037 isolated from environment.

  • PDF

Exclusion of Non-similar Candidates using Positional Accuracy based on Levenstein Distance from N-best Recognition Results of Isolated Word Recognition (레벤스타인 거리에 기초한 위치 정확도를 이용한 고립 단어 인식 결과의 비유사 후보 단어 제외)

  • Yun, Young-Sun;Kang, Jeom-Ja
    • Phonetics and Speech Sciences
    • /
    • v.1 no.3
    • /
    • pp.109-115
    • /
    • 2009
  • Many isolated word recognition systems may generate non-similar words for recognition candidates because they use only acoustic information. In this paper, we investigate several techniques which can exclude non-similar words from N-best candidate words by applying Levenstein distance measure. At first, word distance method based on phone and syllable distances are considered. These methods use just Levenstein distance on phones or double Levenstein distance algorithm on syllables of candidates. Next, word similarity approaches are presented that they use characters' position information of word candidates. Each character's position is labeled to inserted, deleted, and correct position after alignment between source and target string. The word similarities are obtained from characters' positional probabilities which mean the frequency ratio of the same characters' observations on the position. From experimental results, we can find that the proposed methods are effective for removing non-similar words without loss of system performance from the N-best recognition candidates of the systems.

  • PDF

Various Approaches to Improve Exclusion Performance of Non-similar Candidates from N-best Recognition Results on Isolated Word Recognition (고립 단어 인식 결과의 비유사 후보 단어 제외 성능을 개선하기 위한 다양한 접근 방법 연구)

  • Yun, Young-Sun
    • Phonetics and Speech Sciences
    • /
    • v.2 no.4
    • /
    • pp.153-161
    • /
    • 2010
  • Many isolated word recognition systems may generate non-similar words for recognition candidates because they use only acoustic information. The previous study [1,2] investigated several techniques which can exclude non-similar words from N-best candidate words by applying Levenstein distance measure. This paper discusses the various improving techniques of removing non-similar recognition results. The mentioned methods include comparison penalties or weights, phone accuracy based on confusion information, weights candidates by ranking order and partial comparisons. Through experimental results, it is found that some proposed method keeps more accurate recognition results than the previous method's results.

  • PDF

A Study on the cucumber growth by soil warming and warmed water irrigation using solar energy system(3) (태양열 시스템을 이용한 가온관수와 지중가온 방법에 의한 오이의 생육 연구(3))

  • 구건효;김태욱;김진현
    • Journal of Bio-Environment Control
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 1999
  • This study was carried out to estimate the warmed water irrigation and the warmed soil efficiency on protected cultivation of cucumber in winter season. The water of 28$^{\circ}C$ was continuously supplied for soil warming and that is $25^{\circ}C$ for warmed water irrigation. Cucumber growth was analyzed when tile soil kept up the optimum temperature in the root zone. The cucumber growth are compared with the warmed soil plots. isolated warmed soil plots and non-warmed soil plots. The cucumber growth in warmed soil plots and isolated warmed soil plots were 20~50% higher than non-warmed soil plots compare to that by the warmed irrigation. In the non-warmed soil plots, the stem diameter and the number of leaves in the warmed water irrigation plots are 10% higher than those in the normal water irrigation plots. The yields in isolated warmed soil plots were 37~38% higher than non-warmed soil plots and those in warmed soil plots were 85~96% higher than non-warmed soil plots. The fruit length, weight and diameter in warmed soil plots were 15% higher than those in the non-warmed plots.

  • PDF

Design of the Non-Isolated Fuel Cell Boost Charger for the Lithium Polymer Battery with Low Output Ripple (낮은 출력 리플을 갖는 연료전지를 이용한 리튬폴리머 전지용 비절연형 승압 충전기의 설계)

  • Tran, Van Long;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.182-183
    • /
    • 2013
  • In the design of the fuel cell charger, it is important to find out the suitable topology and to design the converter to guarantee the performance of the fuel cell as well as the battery. Most of the chargers developed so far have used step-down converters. However, since the small fuel cell stack can only generate a low voltage, it is required to use the step-up converter to charge the battery. In this paper, a modified non-isolated boost charger topology for the Proton Exchange Membrane Fuel Cell (PEMFC) is proposed to meet the strict ripple requirements for the battery charge and its control method by using PI controller is detailed. The feasibility of the proposed topology and its control method is then verified by the experiments.

  • PDF

Research on High Efficiency Non-Isolated Push-Pull Converters with Continuous Current in Solar-Battery Systems

  • Li, Yan;Zheng, Trillion Q.;Chen, Qian
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.432-443
    • /
    • 2014
  • In order to improve the output efficiency of solar cells and to extend the life span of batteries, the input currents of converters are required to be continuous. If low output voltage ripple is required at the same time, it is obvious that the application of basic two-order converters (such as Buck and Boost derived converters) will not be good enough. In this paper, a lot of non-isolated push-pull converters (NIPPCs) with continuous current will be introduced due to their lower current stress, higher efficiency and better EMC performance. By decomposing the converters into push-pull cells, inductor and free-wheeling diodes, two families of NIPPCs based on single inductor and coupled inductor separately are systematically generated. Furthermore, characteristics analyses for some of the generated converters are also shown in this paper. Finally, two prototypes based on the corresponding typical topologies are built in the lab to verify the theoretical outcomes.

Two-Inductor Non-Isolated DC-DC Converter with High Step-Up Voltage Gain

  • Lee, Sze Sing;Chu, Bing;Lim, Chee Shen;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1069-1073
    • /
    • 2019
  • In this paper, an alternative non-isolated DC-DC converter with a high voltage boosting capability is proposed. Two inductors are used and one of them has its flux linkage increases during its charging period to achieve a high step-up voltage gain. Among the three integrated capacitors, one portrays the partial characteristic of the switched-capacitor technique, while the other two are connected in series across the load. With the two switches controlled using the same duty cycle, the proposed topology demonstrates the merits of a higher and wider range of step-up voltage gain when compared with recent topologies. In addition, a reduction in loss is induced and a higher efficiency is ensured with all the voltage stresses constrained within the output voltage. Operation of the proposed converter is analyzed and validated through experimental results obtained with a prototype.

Non-Isolated Unidirectional Three-Port Cuk-Cuk Converter for Fuel Cell/Solar PV Systems

  • Chandrasekar, Balaji;Chellammal, N.;Nallamothu, Bhargavi
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1278-1288
    • /
    • 2019
  • A DC-DC Non-Isolated Three-Port Cuk-Cuk (NI-TPCC) converter for interfacing renewable energy sources (RESs) such as Fuel Cell (FC) and Photovoltaic (PV) energy with a DC load is presented in this paper. It features single-stage power conversion from both of the input ports to the load port. The proposed NI-TPCC converter is designed based on the classical Cuk converter. The operational modes and power flow are analyzed in the continuous conduction mode (CCM), and the relationships among the port voltages are derived. Continuous currents in all three ports with less ripple enhance the performance of a fuel cell and its operating life. Furthermore, the output inductor is shared with both of the input ports, which reduces the number of active and passive components. The effectiveness of the designed NI-TPCC converter has been validated through simulation and experimental results.