• 제목/요약/키워드: Non-injection

검색결과 1,053건 처리시간 0.023초

Hall Effect on Unsteady Hartmann Flow with Heat Transfer Under Exponential Decaying Pressure Gradient

  • Attia Hazem A.
    • Journal of Mechanical Science and Technology
    • /
    • 제20권8호
    • /
    • pp.1302-1308
    • /
    • 2006
  • The unsteady Hartmann flow of an electrically conducting, viscous, incompressible fluid bounded by two parallel non-conducting porous plates is studied with heat transfer taking the Hall effect into consideration. An external uniform magnetic field and a uniform suction and injection are applied perpendicular to the plates while the fluid motion is subjected to an exponential decaying pressure gradient. The two plates are kept at different but constant temperatures while the Joule and viscous dissipations are included in the energy equation. The effect of the ion slip and the uniform suction and injection on both the velocity and temperature distributions is examined.

미성형 방지를 위한 최적조건 생성 시스템 연구 (A Study on Intelligent Generator of Optimal Process Conditions to Avoid Short Shot)

  • 강성남;허용정;조현찬
    • 한국정밀공학회지
    • /
    • 제19권12호
    • /
    • pp.33-37
    • /
    • 2002
  • A short shot is a molded part that is incomplete because insufficient material was injected into the mold. Remedial actions to control the process conditions can be taken by the injection molding experts based on their knowledge and experience. However, it is very difficult for the non-experts to avoid short shot by finding the proper process conditions such as mold temperature, melt temperature and filling time. In this paper, an intelligent generator of the optimal process conditions based upon fuzzy logic algorithm is proposed so that trial and error can be minimized and the non-experts as well as the experts can also find the optimal process conditions.

사출성형용 지능형 미성형 방지 최적조건 생성 시스템 연구 (A Study on Intelligent Generator of Optimal Process Conditions to Avoid Short Shot)

  • 강성남;허용정;조현찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.402-405
    • /
    • 2001
  • A short shot is a molded part that is incomplete because insufficient material was injected into the mold. Remedial actions to control the process conditions can be taken by the injection molding experts based on their knowledge and experience. However, it is very difficult for the non-experts to avoid short shot by finding the proper process conditions such as mold temperature, melt temperature and filling time. In this paper, an intelligent generator of the optimal process conditions based upon fuzzy logic algorithm is proposed so that trial and error can be minimized and the non-experts as well as the experts can also find the optimal process conditions.

  • PDF

스플리터 단면형상변화에 따른 플라스틱 유량계의 유동진동특성 (Fluidic oscillation characteristics of plastic flow meter with the variation of cross-sectional shape of splitters)

  • 이성희
    • Design & Manufacturing
    • /
    • 제15권2호
    • /
    • pp.56-62
    • /
    • 2021
  • In this study, design technology of a non-mechanical flow meter using fluidic oscillation generated during the fluid flow in the chamber was investigated. To with respect to design a splitter, which is the most important factor in fluid oscillation, a transient flow simulation analysis was performed for three types of shapes and changes in inlet flow velocity. The oscillation characteristics with respect to the time in each case were compared, and it was confirmed that the SM03 model was the best among the presented models. In addition, the FFT analysis of the fluid oscillation results for the SM03 model was used to obtain a linear correlation between the flow velocity change and the maximum frequency, and a frequency of 20.957 (Hz/m/s) per unit flow velocity was obtained. Finally, injection molding simulation and molding experiment of the chamber with the designed splitter were performed.

수핵란의 전 활성화가 토끼 핵이식 수정란의 핵 재구성에 미치는 효과 (Effect of Electrical Preactivation of Recipient Cytoplasm on Nuclear Remodelling in Nuclear Transplant Rabbit Embryos)

  • 전병균;김윤연;정기화;곽대오;이효종;최상용;박충생
    • 한국가축번식학회지
    • /
    • 제21권3호
    • /
    • pp.229-238
    • /
    • 1997
  • Chromosome condensation and swelling of the donor nucleus have been known as the early morphological indicators of chromatin remodelling after injection of a foreign nucleus into an enucleated recipient cytoplasm. The effects of non-preactivation and electrical preactivation of recipient cytoplasm, prior to fusing a donor nucleus, on the profile of nuclear remodelling in the nuclear transplant rabbit embryos were evaluated. The embryos of 16-cell stage were collected and synchronized to G1 phase of 32-cell stage. The recipient cytoplasms were obtained by removing the first polar body and chromosome mass by non-disruptive microsurgical procedure. The separated G1 phase blastomeres of 32-cell stage were injected into non-preactivated recipient cytoplasms. Otherwise, the enucleated recipient cytoplasms were preactivated by electrical stimulation and the separated G1 phase blastomeres of 32-cell stage were injected. After culture until 20h post-hCG injection, the nuclear transplant oocytes were electrofused by electrical stimulation. The nuclei of nuclear transplant embryos fused into non-preactivated and/or preactivated recipient cytoplasm were stained by Hoechst 33342 at 0, 1.5, 2, 4, 6, 8, 10 hrs post-fusion and were observed under an fluorescence microscopy. Accurate measurements of nuclear diameter were revealed with an ocular micrometer at 200$\times$. Upon blastomere fusion into non-preactivated recipient cytoplasm, a prematurely chromosome condensation at 1.5 hrs post-fusion and nuclear swelling at 8 hrs post-fusion were occurred as 91.6% and 86.1%, respectively. But the nuclei of nuclear transplant embryos fused into preactivated recipient cytoplasm, as o, pp.sed to non-preactivated recipient cytoplasm, were not occurred chromosome condensation and extensive nuclear swelling. Nuclear diameter fused into non-preactivated and preactivated recipient cytoplasm at hrs post-fusion was 30.2$\pm$0.74 and 15.2$\pm$1.32${\mu}{\textrm}{m}$, respectively. These results indicated that onset of unclear condensation and swelling which was associated with oocytes activation were critical steps in the process of chromatin swelling. Futhermore, complete reprogramming seemed only possible after remodelling of the donor nucleus by chromosome condensation and nuclear swelling.

  • PDF

사출성형제품의 부형상 설계를 위한 지식형 CAD 시스템에 관한 연구 (A Knowledge-Based CAD System for the Synthesis of Supplementary Features in Injection Molded Parts)

  • 허용정;김상국
    • 대한기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.1933-1947
    • /
    • 1991
  • 본 연구에서는 특징형상기반 CAD 시스템의 기계가공을 고려한 기하학적 모델 링 기능과 부형상의 합성과 해석을 위한 사출성형에 관한 광범위한 지식을 연계, 종합 한 형태의 지식형 CAD 시스템을 제안하였다.

저분자량 헤파린이 쥐 서혜부 유리피판 이식술에 미치는 영향 (The Effect of Low Molecular Weight Heparin on Groin Flap Transplantation in Rat)

  • 이준모;이강욱;이동근
    • Archives of Reconstructive Microsurgery
    • /
    • 제2권1호
    • /
    • pp.77-81
    • /
    • 1993
  • Free tissue transplantation is commonly performed with the brilliant achievement in microsurgery and anticoagulants and antithrombotic agents have been prescribed in the procedures. However, there is no clean-cut indication as to which agents would be more effective in every steps and final consequences. Low molecular weight heparins inhibiting coagulation in plateletrich plasma and acting on the vascular endothelium have antithrombotic and fibrinolysis action. The experiment with rat groin free flap transplantation after 6-hour ischemia and injection of the low molecular weight heparin was performed and the results between the injection and non-injection group were analysed as follows, 1. Both of the 24-hour groups, vessel patency was not proportional to color change of the groin flap. 2. On the second day after anastomois, heparin-injection group showed intact intima, patent lumen without thrombus, and mild granulomatous inflammation around the suture material and control group with doubtful patency revealed intimal loss and thrombus formation. 3. On the 5th, 7th, and 9th postoperative day, heparin group was patent in anastomosis and showed acute inflammatory cells. 4. The 7th-week period, heparin-injection group showed intact flap color, patent lumen with intact intima and persistent foreign body granuloma.

  • PDF

고주파유도 급속 금형가열 과정의 3차원 유한요소해석 (Three-Dimensional Finite Element Analysis of the Induction Heating Procedure of an Injection Mold)

  • 손동휘;서영수;박근
    • 소성∙가공
    • /
    • 제19권3호
    • /
    • pp.152-159
    • /
    • 2010
  • Rapid mold heating has been recent issue to enable the injection molding of thin-walled parts or micro/nano structures. High-frequency induction is an efficient way to heat mold surface by electromagnetic induction in a non-contact manner, and has been recently applied to the injection molding due to its capability of rapid heating and cooling of mold surface. The present study covers a three-dimensional finite element analysis to investigate heating efficiency and structural safety of the induction heating process of an injection mold. To simulate the induction heating process, an integrated simulation method is proposed by effectively connecting an electromagnetic field analysis, a transient heat transfer analysis and a thermal stress analysis. The estimated temperature changes are compared with experimental measurements for various types of induction coil, from which heating efficiency according to the coil shape is discussed. The resulting thermal stress distributions of the mold plate for various types of induction coils are also evaluated and discussed in terms of the structural safety.

주사실습 교육방법이 간호학생의 불안에 미치는 영향 (Effects of Injection Practice Education Methods on Anxiety in Nursing Students)

  • 최성녀
    • 부모자녀건강학회지
    • /
    • 제19권1호
    • /
    • pp.17-24
    • /
    • 2016
  • Purpose: This study examined the level of students' anxiety depending on the injection type, education methods, and the students' characteristics. Methods: 209 first year nursing students were randomly assigned to each group by three factors -injection methods, video watching, and number of practice. Injection methods had two levels (IV and IM). Video watching also had also two levels (video watching and non-watching group). And the number of practice had 4 levels according to number of practice (2, 4, 6, and 8 times). The video watching group was watching 30 minutes video before manikin practice. After 5 to 15 minutes of manikin practice, the sufficiency of practice and the level of anxiety were measured. The data were analyzed by t-test and one way ANOVA. Results: The anxiety of the IV practice was higher than that of IM. The students who have experiences of working at hospital or the similar institution were lower in anxiety. The higher self-confident in sufficiency of practice lowered the students' anxiety. But watching video and the number of practices had no effects on the level of anxiety. Conclusion: To effectively lower the anxiety of nursing students in the nursing practice education, lecture methods and education tools are needed to develop.

  • PDF

VCO노즐에서 고압으로 분사되는 디젤분무의 특성 (Diesel Spray Developement from VCO nozzles for High Pressure Direct-Injection)

  • 강진석;배충식
    • 한국자동차공학회논문집
    • /
    • 제8권3호
    • /
    • pp.28-36
    • /
    • 2000
  • Spray characteristics of diesel fuel injection is one of the most important factors in diesel combustion and pollutant emissions especially in HSDI (High Speed Direct Injection) diesel engines where the interval between the onset of combustion and the evaporation of atomized fuel is relatively short, An investigation into various spray characteristics from different holes of VCO(Valve Covered Orifice) nozzles was performed and its results were compared to standard sac nozzle. The global characteristics of spray, including spray angle, spray tip penetration, and spray pattern were measured from the spray images which were frozen by an instantaneous photography with a spark light source. For better understanding of spray behavior, SMD of the fuel sprays from multi hole nozzles were measured with back light imaging while the sprays from the other holes are covered by a purpose-built nozzle cap. The investigation manifestly reveals the different spray patterns at the beginning of injection produced by VCO nozzles can be identified as three distinct types with their own macroscopic and microscopic characteristics, while macroscopic non-uniformity disappears at 0.9∼1.0ms from the start of injection.

  • PDF