• 제목/요약/키워드: Non-fixation method

검색결과 56건 처리시간 0.026초

비고정 방법을 사용한 관골 체부 골절 정복술 (Open Reduction and Non-fixation Method for the Zygoma Body Fracture)

  • 박보영;김양우;강소라
    • 대한두개안면성형외과학회지
    • /
    • 제10권2호
    • /
    • pp.76-80
    • /
    • 2009
  • Purpose: Zygoma is a major portion of the midfacial skeleton, forms the malar prominence and the three adjacent bony articulations. Zygoma fracture is a very common in facial trauma. Open reduction and rigid fixation of displaced zygoma fractures are necessary to avoid immediate and delayed facial asymmetry and depression. However, it is possible to happen the complications related to the plates and screws. So, we planned to treat the 24 patients of Group II, III, IV zygoma fractures with precise reduction and non-fixation method via intraoral approach. Methods: From August, 2006, to August, 2009, we treated 24 cases of zygoma fracture with reduction and non-fixation methods. Before the surgery, we choose the patients who could be treated with this method among the Group II, III, IV patients. Results: No patients in this study had postoperative complications such as displacement of bony fragments, facial depression and asymmetry, malocclusion, hypoesthesia. Satisfactory aesthetic and functional results can be obtained. Conclusion: In the treatment of the zygoma fracture, it is possible to treat with precise reduction and non-fixation method. The greatest advantage is to decrease the operative time, no need to wide dissection, no complications related to the plates and screws. For the using of this method, it is necessary to choose the adequate patients through the preoperative planning.

대퇴부 원위부 골절에 관한 금속판 보강술의 응력 해석 (Stress Analysis of Plate Augumentation for Distal Femur Fracture)

  • 김지숙;범현규;양영수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.816-819
    • /
    • 1997
  • The operation of femoral non-union after IM(Intramedullary) nailing in distally femoral fractures is considered. Augmentive plate fixation is the management of femoral non-union after IM nailing. The purpose of this study is to compare the bending, torsional stiffness and stress distribution of the two operations by the FEM(Finite Element Method). Augmentive plate fixation is better than IM nail fixation. These results conclude that plate augmentation is a useful method for the unstable femoral non-union after interlocking IM nailing.

  • PDF

원위 경비골 골절에 대한 골수강내 금속정술에서 비골 고정이 족근 관절 기능에 미치는 영향 (The Effect of Fibular Fixation on Ankle Function in Intramedullary Nailing for Distal Tibiofibular Fractures)

  • 서병호;이수원;공규민;김동준;오현근
    • 대한족부족관절학회지
    • /
    • 제13권2호
    • /
    • pp.169-174
    • /
    • 2009
  • Purpose: To evaluate the clinical results between interlocking intramedullary nail with fibular fixation and nail only for treating distal tibiofibular diaphyseal fractures. Materials and Methods: From March 2003 to September 2006, 19 distal tibiofibular fractures were antegrade nailed after anatomical reduction and fixation of fibular fractures, and another 37 fractures fixed with nails only. Average age of patients was 48.6 years. These two groups were compared by VAS (visual analogue scale) & ankle ROM according to degree of comminution and fracture configuration. The statistical analysis was evaluated by t-test. Results: There was no statistical difference between fibular fixation group and non-fixation group in VAS score according to fracture comminution and configuration (p>0.05). However, compared according to fracture configuration, mean ankle eversion of fibular fixation group in oblique fractures was 18.3 degrees, and that of non-fixation group was 12.5 degrees (p<0.05). In addition, mean ankle plantar flexion, dorsiflexion, inversion and total ankle ROM of fibular fixation group in spiral fractures was 40.0, 20.0, 30.0 and 108.3 degrees of each and that of non-fixation group was 38.3, 18.5, 27.0 and 101.7 degrees (p<0.05). Conclusions: In oblique and spiral fractures of distal tibiofibular diaphysis, interlocking intramedullary nail with fibular fixation had the advantage in postoperative ankle ROM. So, it can be a worthy method for the treatment of distal tibiofibular diaphyseal fractures.

  • PDF

TightRope$^{TM}$ Device를 이용한 족근 중족 관절 손상의 치료(1예 보고) (Lisfranc Injury Repair with the TightRope$^{TM}$ Device (A Case Report))

  • 조재호;오인석
    • 대한족부족관절학회지
    • /
    • 제15권4호
    • /
    • pp.243-246
    • /
    • 2011
  • Lisfranc injury is complex and difficult to treat. Making the correct diagnosis and achieving an anatomical reduction are important factors in regard to achieving a favorable outcome with this injury. We describe a new technique that we have found to be useful for stabilizing Lisfranc injury. This method is relatively fast and simple, and it provides non-rigid fixation. Also, it eliminates the need for implant removal. To date, we have achieved predictable results for stabilizing and treating this injury with the use of a $TightRope^{TM}$ Device, instead of traditional interfragmental screw fixation. In this report, we describe a case in which this method was used with satisfactory short-term results.

기관내관 순환고정방법이 중환자실 환자의 비계획적 발관 및 구강.안면 피부 통합성에 미치는 효과 (Effects of Rotated Endotracheal Tube Fixation Method on Unplanned Extubation, Oral Mucosa and Facial Skin Integrity in ICU Patients)

  • 최영순;채영란
    • 대한간호학회지
    • /
    • 제42권1호
    • /
    • pp.116-124
    • /
    • 2012
  • Purpose: The study was done to compare effects of two endotracheal tube (ET tube) fixation methods (rotated fixation versus conventional) on unplanned extubation and skin integrity for orally intubated patients in intensive care units. Methods: The research design was a non-equivalent control group with repeated measures design. Participants were 80 patients; 40 participants assigned to each group. ET tube for the experimental participants fixed with rotated method every morning. Unplanned extubation was assessed by bedside nurses using the unplanned extubation report form. Oral mucosa and facial skin integrity were assessed using oral assessment guide and facial skin integrity assessment guide at day 3, 7, 10 and 14. Results: There was no difference in the unplanned extubation rate between the two groups. Oral mucosa impairment scores for the rotated fixation method were significantly lower at day 7 (p=.044), 10 (p=.048) and day 14 (p=.037). Also facial skin integrity impairment scores for the same group were significantly lower at day 7 (p=.010), 10 (p=.003), and 14 (p=.002). Conclusion: Results of the study suggest that the rotated fixation method is effective for these patients, to prevent impairment of oral mucosa and facial skin integrity. Further research is needed to prevent unplanned extubation.

후방까지 연장된 안와하벽골절에서 안구함몰 예방을 위한 Medpor® 내고정술 (Internal Fixation of Medpor® Implant for Prevention of Enophthalmos in Posteriorly Extended Orbital Floor Fracture)

  • 석정훈;지소영;김태범;양완석
    • 대한두개안면성형외과학회지
    • /
    • 제9권2호
    • /
    • pp.55-61
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the effectiveness of internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw which is used for prevention of enophthalmos in posteriorly extended large orbital floor fracture. Methods: From Jun. 1997 to Dec. 2007, 21 patients who were diagnosed with posteriorly extended large orbital floor fractures were classified into two groups. One group(n=11) had undergone reduction surgery with regular $Medpor^{(R)}$ sheets without any fixation method, while the other group(n=10) had their $Medpor^{(R)}$ sheets fixed with the $BioSorb^{TM}FX$ screws. The two groups were evaluated by comparison of their enophthalmos degree and effectiveness. Results: In the non-fixation group, six patients had enophthalmos preoperatively and three of them showed persistent enophthalmos postoperatively. In postoperative CT examination, displacement of $Medpor^{(R)}$ implant with soft tissue impaction into maxillary sinus was observed in the patients. In the screw fixation group, three patients had enophthalmos preoperatively, but none of them suffer from complication such as residual enophthalmos, soft tissue impaction, muscle entrapment or optic nerve compression postoperatively. Conclusion: Internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw on the medial surface of orbital floor provides firm stabilization of implants and surrounding soft tissues and can be an effective option especially when postoperative implant displacement or malposition was expected.

두과 작물의 질소고정과 유기조사료생산을 위한 작부체계 (Nitrogen Fixation of legumes and Cropping System for Organic Forage Production)

  • 이효원;박형수
    • 한국유기농업학회지
    • /
    • 제10권1호
    • /
    • pp.49-63
    • /
    • 2002
  • In order to supply 85% of total organic feed in ruminants and 80% in non-ruminants for organic animal production, nitrogen fixation ability of legume should be used in domestic roughages production. 50% of Europe organic farmer use intercropping legume in as green manure. This article is dealing with amount of biologically fixed nitrogen used by legumes and methods for estimating the transfer of biologically fixed N in rotation and separating the N benefit into fixed N and non-fixed N components are reviewed. Available data indicate that transfer amount of N to non legumes was from 50∼9.6(kg/ha) in legume-cereal rotations and proportion of legume N varied with seasons, 90% in summer, 50% in autumn. The important point in cropping system for legumes have to be included for organic forage production 6 year rotation is based on pasture system of 3 year pasture + 2 year annual(com, sudangrass), again pasture. Rye, barly and Italian ryegrass+legumes(vetch, crimson and pea) can be one of option in spring, com, soybean, sudangrass and Japanese bamyard millet would be seeded after spring harvest in the field. Farmer can make good use of rice paddy field as forge production potential area after harvesting rice. Italian, burly and rye+vetch and crimsonclover may be grown in autumn or spring time at the rice field.

  • PDF

충격흡수 특성의 향상을 위하 내고정용 특수 와셔에 관한 연구 (The Use of Special Washers in Bone Plates for Improved Impact-Absorbing Characteristics)

  • 김윤영;김장수
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권4호
    • /
    • pp.457-462
    • /
    • 1995
  • 본 논문에서는 골절 치료에 사용되고 있는 기존의 금속판과 나사고정 장치를 개선하여, 뼈에 점진적인 생리하중을 가할 수 있도록 고안된 내고정 장치를 살펴보았다. 이 장치는 골절판과 나사를 결합할 때, 그 사이에 생분해성 재질이나 기타 댐핑 특성이 우수한 재질의 와셔를 삽입하는 것을 그 특징으로 한다. 본 논문에서는 주로 이 장치의 충격 흡수 특성을 파악하기 위해, 돼지 대퇴골과 소 경골에대해 충격 망치를 이용하여 얻은 진동 실험 결과를 보여주며, 특히 와셔의 유무에 따른 충격 흡수 특성을 실험적으로 비교하였다.

  • PDF

A modified method of augmented distal clavicle fracture osteosynthesis with a Fibertape coracoclavicular cerclage

  • Wu, ChengHan;Teo, Timothy Wei Wen;Wee, Andy Teck Huat;Toon, Dong Hao
    • Clinics in Shoulder and Elbow
    • /
    • 제25권3호
    • /
    • pp.230-235
    • /
    • 2022
  • Background: Unstable distal clavicles experience high non-union rates, prompting surgeons to recommend surgery for more predictable outcomes. There is a lack of consensus on the optimal method of surgical fixation, with an array of techniques described in the literature. We describe an alternative method of fixation involving the use of a distal clavicular anatomical locking plate with Fibertape cerclage augmentation in our series of patients. Methods: Nine patients (8 males and 1 female), with a mean age of 36 years, who sustained unstable fracture of the distal clavicle in our institution were treated with our described technique. Postoperative range of motion, functional and pain scores, and time to radiographic union were measured over a mean follow-up period of 10 months. Incidences of postoperative complications were also recorded. Results: At the last patient consult, the mean visual analog scale score was 0.88±0.35, with a mean Disabilities of the Arm, Shoulder, and Hand (DASH) score of 1.46±0.87 and American Shoulder and Elbow Surgeons (ASES) score of 94.1±3.57. The mean range of motion achieved was forward flexion at 173°±10.6°, abduction at 173°±10.6°, and external rotation at 74.4°±10.5°. All patients achieved internal rotation at a vertebral height of at least L2 with radiographical union at a mean of 10 weeks. No removal of implants was required. Conclusions: Our described technique of augmented fixation of the distal clavicle is effective, produces good clinical outcomes, and has minimal complications.

응급실 침대 위 흉부전후방향 엑스선 검사를 위한 상의고정장치 개발 (Development of the Upper Wear Fixation Device for Chest AP X-ray Imaging on the Emergency Stretcher Bed)

  • 임우택;홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.205-211
    • /
    • 2022
  • This study aimed to provide basic data for 3D printing in the medical health field by developing upper wear fixation device (UWFD), an auxiliary device for shortening chest AP examination time on emergency room beds and non-contact with patients. The standard of hooks was modeled according to the bed frame using the Autodesk Fusion 360. It was printed with Form2 (Formlabs, Somerville, MA, USA), as SLA (stereo lithography apparatus) method, and was washed and hardened using Form Wash and Form Cure. The completed UWFD conducted an online survey on 4 items of stability, convenience, availability, preference and general characteristics. The total stability average was 3.93±0.80, the total convenience average was 3.93±0.68, the total availability average was 4.01±0.89, and the total preference average was 3.80±1.08. This study was significant in suggesting improvements in the general X-ray examination process in the emergency room by designing and making aids to easily fixing the patient's top to the frame of the emergency bed while meeting promptness and non-contact with the patient.