• Title/Summary/Keyword: Non-extraction

Search Result 1,070, Processing Time 0.03 seconds

Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.38-48
    • /
    • 2020
  • PURPOSE. The objective of this literature review was to analyze the cumulative survival rates (CSRs) of rigid and non-rigid double-crown-retained removable dental prostheses. MATERIALS AND METHODS. Screening of the literature published from January 1995 to December 2019 was performed by using electronic data base (Pubmed) and manual search. The CSRs of rigid and non-rigid double crown removable dental prostheses were investigated. RESULTS. A total of 403 articles were reviewed and 56 relevant articles of them were selected. Subsequently, 25 articles were included for data extraction. These articles were classified according to rigid and non-rigid type double crowns and further subdivided into teeth, implants, and teeth-implant combination types. The CSRs of rigid type double crown ranged from 68.9% to 95.1% of 5 to 10 years in tooth abutments, 94.02% to 100% over a 3-year mean observation periods in implant abutments, and 81.8% to 97.6% in tooth-implant combination. Non-rigid type double crowns had various CSR ranges from 34% to 94% maximum during 10 years observation in teeth abutment. The CSRs of non-rigid type had over 98% in implant abutments, and ranged from 85% to 100% in tooth-implant combination. CONCLUSION. The CSRs of double crowns varies according to types. With accurate evaluation of the remaining teeth and plan of the strategic implant placement, it could be successful treatment alternatives for partially or completely edentulous patients.

Separation of Text and Non-text in Document Layout Analysis using a Recursive Filter

  • Tran, Tuan-Anh;Na, In-Seop;Kim, Soo-Hyung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.10
    • /
    • pp.4072-4091
    • /
    • 2015
  • A separation of text and non-text elements plays an important role in document layout analysis. A number of approaches have been proposed but the quality of separation result is still limited due to the complex of the document layout. In this paper, we present an efficient method for the classification of text and non-text components in document image. It is the combination of whitespace analysis with multi-layer homogeneous regions which called recursive filter. Firstly, the input binary document is analyzed by connected components analysis and whitespace extraction. Secondly, a heuristic filter is applied to identify non-text components. After that, using statistical method, we implement the recursive filter on multi-layer homogeneous regions to identify all text and non-text elements of the binary image. Finally, all regions will be reshaped and remove noise to get the text document and non-text document. Experimental results on the ICDAR2009 page segmentation competition dataset and other datasets prove the effectiveness and superiority of proposed method.

The Comparison between Hot-Water Extracts and Microwave Extracts of Scutellaria radix for Antioxidant and Neuroprotective Effects (가열 추출법과 마이크로웨이브 추출법을 이용한 황금 물 추출물의 뇌세포 보호 및 항산화 효과 비교 연구)

  • Lee, Dong-Sung;Ko, Wonmin;Kim, Kyoung-Su;Kim, Dong-Cheol;Yoon, Chi-Su;Cho, Kwangho;Cui, Xiang;Oh, Hyuncheol;Kim, Youn-Chul
    • Korean Journal of Pharmacognosy
    • /
    • v.45 no.1
    • /
    • pp.55-61
    • /
    • 2014
  • Microwaves are non-ionizing electromagnetic waves of frequency between 300MHz to 300GHz and positioned between the X-ray and infrared rays in the electromagnetic spectrum. In recent years, the use of microwave for extraction of ingredient from plant material has shown remarkable research interest and potential. Scutellaria radix has been used as a traditional medicine for a variety of diseases. It has been reported to exert beneficial health effects, such as anti-bacterial, antiviral, anti-inflammatory, and free-radical scavenging. Oxidative stress or the accumulation of reactive oxygen species (ROS) leads neuronal cellular death and dysfunction, and it contributes to neuronal degenerative disease such as Alzheimer's disease, Parkinson's disease and stroke. In this study, we aimed to compare the neuroprotective and antioxidant effect of Scutellaria radix extracted by different methods using hot-water extraction (SBE-DW) or microwave extraction (SBE-DW-MW). As a result, we first examined HPLC analysis of hot-water and microwave extracts of Scutellaria radix. The hot-water and microwave extracts of Scutellaria radix showed the discernible difference patterns of HPLC analysis. Microwave-water extracts of Scutellaria radix increased DPPH radical scavenging activity more than hot-water extraction. Microwave-water extracts of Scutellaria radix also showed neuroprotective effects and ROS inhibition against glutamate-induced oxidative stress in mouse hippocampal HT22 cells, but hot-water extraction not showed. In addition, the phosphorylation of MAPKs induced by glutamate insult was prevented by microwave-water extracts of Scutellaria radix. Thus, these results suggested that microwave extraction can be utilized for improving the extraction efficiency and biological activity of Scutellaria radix.

A Study on Road Noise Extraction Methods for Listening (청음용 자동차 로드노이즈 추출 방법 연구)

  • Kook, Hyung-Seok;Kim, Hyoung-Gun;Cho, Munhwan;Ih, Kang-Duck
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.7
    • /
    • pp.844-850
    • /
    • 2016
  • This study pertains to the extraction of the road noise component of signals from a vehicle's interior noise via the traditional frequency domain and time domain system identification methods. For road noise extraction based on the frequency domain system identification method, the appropriate matrix inversion strategy is investigated and causal and non-causal impulse response filters are compared. Furthermore, appropriate data lengths for the frequency domain system identification method are investigated. In addition to the traditional road noise extraction methods based on frequency domain system identification, a new approach to extract road noise via the time domain system identification method based on a parametric input-output model is proposed and investigated in the present study. In this approach, instead of constructing a higher order model for the full-band road noise, input and output signals are processed in the subband domain and lower order parametric models optimal to each subband are determined. These parametric models are used to extract road noises in each subband; the full band road noise is then reconstructed from the subband road noises. This study shows that both the methods in the frequency domain and the time domain successfully extract the road noise from the vehicle's interior noise.

Highly CO2-soluble 5-Amido-8-hydroxyquinoline Chelating Agents for Extraction of Metals in Sc-CO2

  • Chang, Fei;Park, Seo-Hun;Kim, Hakwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.7
    • /
    • pp.1327-1331
    • /
    • 2008
  • Novel $CO_2$-soluble 8-hydroxyquinoline (8-HQ) chelating agents were synthesized and evaluated for solubility and metal ion extraction ability in supercritical $CO_2\;(Sc-CO_2)$. Among them, secondary amide-containing 8- HQ derivatives cannot be dispersed well into Sc-$CO_2$, but tertiary amide-containing derivatives can dissolve completely in Sc-$CO_2$ even at low CO2 pressures, perhaps owing to the predominant intermolecular interaction between the chelating agent and the $CO_2$ molecule. Based on 8-HQ chelating agent solubility data, we investigated the extraction of metal ions ($Co^{2+}$, $Cu^{2+}$, $Sr^{2+}$, $Cd^{2+}$, and $Zn^{2+}$) using two highly $CO_2$-soluble 8-HQ derivatives (4d, 4e) in Sc-$CO_2$. The extraction efficiency of tertiary amide-containing 8-HQ ligands, both fluorinated and non-fluorinated forms, was dramatically increased in the presence of diethyl amine (organic base). We suggest that diethyl amine could play an important synergistic role in the stronger metal binding ability of 8-HQ through an in situ deprotonation reaction in Sc-$CO_2$ medium.

Periotome versus piezotome as an aid for atraumatic extraction: a randomized controlled trial

  • Mohammed Abdullah, Alraqibah;Jingade Krishnojirao Dayashankara, Rao;Bader Massad, Alharbi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.6
    • /
    • pp.356-362
    • /
    • 2022
  • Objectives: A single-blinded randomized controlled trial was designed to compare and evaluate the effectiveness of the periotome and piezotome as aids for atraumatic extraction and its sequalae. Materials and Methods: The study sample comprised 48 teeth, equally allotted to the piezotome or periotome groups by random allocation, in participants aged 19-62 years. All samples in both groups had either complete tooth structure or intact roots without crowns and had mobility ≤grade II. Clinical parameters of operative duration, presence or absence of gingival laceration, reported operative and postoperative pain, and intake of analgesics following extraction were recorded. IBM SPSS software package version 22 was used for data entry and analysis. Results: The mean operation time was significantly (P≤0.05) longer in the piezotome group than in the periotome group. However, fewer gingival lacerations were observed with use of a piezotome than with a periotome, although no significant difference was observed. The piezotome group reported significantly (P≤0.05) higher visual analog scale (VAS) pain scores during the procedure and non-significantly higher scores thereafter until the third postoperative day. In the piezotome group, the dosage of analgesic was higher, although the periotome group had a higher percentage of participants who used analgesics postoperatively; however, these differences were not statistically significant. Conclusion: The present clinical trial favors the use of periotome over piezotome for atraumatic extraction due to shorter operating time, lower postoperative VAS pain scores, and lower dosage of analgesics despite the superior ability of the piezotome to prevent gingival laceration.

The Effect of Extracapsular Cataract Extraction and Posterior Chamber Lens Implantation on Intraocular Pressure (백내장적출술 및 인공수정체삽입술이 안압에 미치는 영향)

  • Cha, Soon-Cheol;Lee, Kyoo-Won
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.277-283
    • /
    • 1994
  • We studied the change in intraocular pressure (IOP) in 15 consecutive cataract patients who underwent extracapsular cataract extraction and posterior chamber lens implantation between Feb. 1993 and Apr. 1993 to evaluate the effect of this surgery on postoperative IOP. To evaluate the clinical usefulness of non-contact tonometer, the intraocular pressures were measured with Kowa non-contact tonometer (TM-2000, Japan) as well as Goldmann applanation tonometer. There was a decrease in IOP of $3.4{\pm}2.9$mmHg (p<0.00l) 3 months after this surgery and the intraocular pressure differences between pseudophakic eyes and contralateral phakic eyes at 3 months postoperatively were $2.4{\pm}3.8$mmHg (p<0.05). The correlation coefficient between non-contact tonometer and Goldmann tonometer was 0.8876 (p=0.001) in the postoperative 76 eyes. Therefore, our results suggest that extracapsular cataract extracion and posterior chamber lens implantation alone can be a useful surgical method in cataract patient with ocular hypertension, and non-contact tonometer was relatively accurate in measuring the postoperative intraocular pressure.

  • PDF

Feature Extraction Program for Prostate Parameters (전립선 진단을 위한 특징 파라미터 추출 프로그램)

  • Choi, Hwan-Yong;Lee, Dae-Jong;Cha, Eun-Jong;Cho, Young-Im;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.5
    • /
    • pp.659-665
    • /
    • 2008
  • Uroflowmetry is a non-invasive and easily performed method to diagnose the benign prostate hypertrophy(BPH) which is frequently found in the aged men. There are some manufactures to provide a diagnosis tool for the benign prostate hypertrophy. Conventional products, however, render only the result of parameters related with prostate hypertrophy, not additional information such as the uroflowmetry variation and related personal information. In this paper, we developed an effective system for feature extraction of prostate hypertrophy as well as online program for wireless networked database management which can be used under ubiquitous environments and Labview based Window program.

Method for nutrient solution extraction from used diposed diapers (일회용 폐기저귀에서 양액 추출 방안)

  • Nobel, Ballhysa;Han, Se Hee
    • Journal of Energy Engineering
    • /
    • v.29 no.3
    • /
    • pp.34-41
    • /
    • 2020
  • Used disposable diapers have been considered for a long time as a type of waste difficult to recycle and valorize due to their composite nature including plastic, cellulose pulp, a super absorbent polymer and either urine, feces or both. Therefore, the fate of disposed diapers often is either incineration or landfill burial which both have various adverse environmental impacts. However, used disposable diapers contain nutrients: cellulose is an organic matter while urine and feces contain non negligible amounts of nitrogen, phosphorus and potassium which are primary nutrients included in most chemical fertilizers used in agriculture. In a scope of waste recycling and valorization, this study focuses on developing a method to achieve nutrient solution extraction from used disposable diapers. The experiment essentially consists in shredding the diapers and letting them macerate in solutions of sodium hydroxide with various concentrations to allow breaking down of the cellulose and super absorbent polymer and release of urine and feces before sterilizing the solutions in an autoclave to remove potential coliform bacteria. At the end of the experiment, a set of parameters is measured for the final solution to identify concentrations of nutrients as well as presence or absence of harmful substances. Results are discussed and directions for future studies are suggested, which include mechanization of the diapers shredding process or added aeration to enhance nitrification and absorption of extracted nutrients from plants.

A Sequential Separation Procedure for the Determination of Uranium, Thorium and Their Isotopes in Geological Materials (지질시료 중의 U과 Th 분석 및 자연방사성동위원소 측정을 위한 화학적 분리)

  • Kim, Jung Suk;Choi, Kwang Soon
    • Analytical Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.307-314
    • /
    • 1997
  • Inductively coupled plasma atomic emission spectrometry(ICP/AES) was used for the determination of uranium and thorium in geological materials. Samples were predecomposed by mixed acid digestion technique. The separation of the uranium and thorium was achieved by systematic solvent extraction with TTA(thenoyltrifluoroacetone) and TOA (tri-n-octylamine) and back extraction into HCl. The results for standard rock sample, NIST SRM 278, showed a good agreement with those certified from NIST as well as found values by other non-destructive techniques. Additional purification for extracted portions was carried out by anion exchange chromatography for measurement of several natural radioisotopes of uranium and thorium by alpha spectrometry.

  • PDF