• Title/Summary/Keyword: Non-dimensional Tractive Force

Search Result 3, Processing Time 0.025 seconds

Research on Relationship of Bed Material and Channel Characteristics (대표 입경과 하도 특성의 관계 분석)

  • Lee, Du-Han;Son, Min-Woo;Kim, Myoung-Hwan;Kim, Chang-Wan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.613-617
    • /
    • 2006
  • Bed material in natural streams is affected by geological characteristics of upstream and acting focre by flow of stream. Acting force in streams are also affected by bed slope and discharge of streams. Yamamoto(1994) suggested that channel reaches with similar slope share similar characteristics values in representative bed material size, tractive force, channel width and depth. He also suggested that main factors dominating channel characteristics are mean annual discharge, epresentative bed material size and bed slope. Bed material shows physical and ecological characteristics of channels. In this research, characteristics of bed material in natural or close to natural streams were studied and compared with Janpanese stream data. In the result, characteristics of gravel and sand material can be presented in the term of non-dimensional tractive force, bed slope and bed material size.

  • PDF

Hydraulic Studies on Recirculating Aquaculture Basin (순환여과식 사육수조의 수리학적 연구)

  • LEE Jong-Sup
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.2
    • /
    • pp.173-182
    • /
    • 1994
  • A numerical experiment on the effective discharge of waste materials caused in recirculating aquaculture basins was performed. The numerical model used in this study was a 4-level hydrodynamic and advection-diffusion model. Flow structures and settling processes of ss in the various mathematical model basins are discussed. The calculated flow fields of the numerical basin corresponded well with the measured velocity in field basin. In the cases of steep bottom slopes in 4/30, the non-dimensional tractive force($U{\ast}/U{\ast}_c$) which is all important parameter for the deposition pattern of waste materials was stronger than with the mild slope one. The settling pattern of ss depended considerably on the degree of bottom slope of basin. To concentrate deposited waste materials into the center discharge pipe, it is useful to design a cylindrical basin with a steeply conical bottom. In addition, to prevent movement of the deposit area away from the center, it is necessary to locate the circulating ducts at diametrically opposed points on the basin sides.

  • PDF

A Study on Balanced -type Oseillating Mole-Drainer(III)-Model Test for Draft Force, Torque, Power and Moment (평행식 진동탄환 암거 천공기의 연구(III)-견인력, 토크, 동력 및 모멘크에 관한 모형시험-)

  • 김용환
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 1976
  • This paper is the third one of the study on balanced type oscillating mole-drainer, the first one was presented in No 9. Gyeongsang College Report and the second one in Vol. 17, No.4 of the KSAE. In the first part of this study, the characteristics of traction forces between the nonoscillating earth working equipments and oscillating ones was compared. A model of the balanced type oscillating mole-drainer, which composed of a mechanism that may reduce the machine vibration, was designed following the dimensional analysis and similitude technique. The model test was carried out to clarify the balancing mechanism of the oscillating parts and other parts of the machine. In the light of the results from the model tests, a prototype machine was made for experimental purpose. Results from the field test by a reported in the near future. In the second report, the model tests were carried out under the same soil conditions, i.e, . oscillating frequency, running velocity, and oscillating amplitude, etc. It was clear that use of balanced type oscillating model could substantially reduce the vibration of the whole system of the machine, when compared with the nonoscillating type model. In this paper(the third report), results of investigation on the traction force, power requirement, and moment. etc, is presented. Analysis of variance technique was used for analyzing the effect of the frequency, amplitude, and running velocity on the draft force, torque, power requirements, and moments. The results obtained from the model tests are as follows, 1) By practicing a balanced-type oscillating mole-drainer, it was possible to reduce the traction resistance by 55.1-61. 2 percent of traction resistance, however, was 1.75 - 1.95 times greater than the value of resistance which was induced by use of a mole-drainer with single bullet. The resistance of rear shank against soil was considered as a main causing factor of the above results. 2) As the oscillation frequency was increased, the traction resistance was decreased. Considering on the effect of oscillation the greater the amplitude, and the slower the running velocity was, the greater the reduction ratio of traction resistance was. 3) The ratio of the traction resistance of oscillating mole-drainer to that of non-oscillating one could be represented as a function of dimensionless variable (V/$Af$). The results from the tests were well agreed with the reported results from the experim ents on oscillation plow or hoe. 4) By taking a lower value of (V/$Af$), reducing the traction resistance was possible. This fact meant, however, that the efficiency of mole drain practice would be lower. 5) It was experimentally confirmed under the same condition of soil that the variable (R/$rD1^3$) could be represented as a function of a variable($V^2/gD$) when a non\ulcornerocillating mole-drainer was used. 6) When a oscillating mole-drainer was used, the variable(R/$rD_1^{3}$) could be represented as a function of two variables ($v^2/gD_1$) and (V^2/gD_1$). 7) The torque was not affected by a change of frequency. However, a relation of proportionality existed between torque and amplitude, running velocity, and ratio of bullet diameter. When a balanced type oscillating mole-drainer with two bullets was used, torque was increased by 52.8-78. 4 percent and total power requirement was also increased. 8) Total power requirement was increased linearly in accordance with the increasing frequency, 41.96 percent of total power was used for oscillating action. The magnitude of total power requirement was 1. 8-9. 4 times greater than that of a non-oscillating mechanism. In the view point of power requirement, it was not advisable to increase the frequency, amplitude, running velocity, and ratio of bullet diameter at the same time. 9) Only the positive moment occured in the rear shank. Change of the diameter of a rear bullet, could not affect the balancing against the soil resistance. It was necessary for rear bullet to have a large resistance against soil only when the rear bullet was in backward motion. 10) Within an extent of the experimental base, optimum limits for several design factors were A=0.5cm, $f$=22.5Hz, V=O. 05m/sec, and $\lambda$=1.0 By adapting these values traction resistance was reduced by 40 percent and vibration acceleration wa s reduced by 60 percent. Even though the total , power requirements for operating a balanced type oscillation mechanism was greater ~than that of non-oscillating one, using a oscillating mechanism would be more effective. Because a balanced type oscillating mechanism is used, tractive resistance will be reduced and then the lighter . tractive equipment could be used.

  • PDF