• 제목/요약/키워드: Non-conditioning

검색결과 339건 처리시간 0.026초

헬륨의 비이상기체 거동에 따른 VM열펌프의 손실 (Thermal Losses Due to Non-ideal Gas Behavior of Helium in VM Heat Pumps)

  • 백종훈;장호명
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.279-287
    • /
    • 1996
  • A cycle analysis is performed to investigate how the non-ideal gas behavior of helium reduces the heating capacity of VM heat pumps. Since the operating pressures of VM heat pumps are as high as 1 to 20 MPa, the compressibility factor of helium becomes clearly greater than 1 and the non-ideal behavior always represents a thermal loss in heating. To calculate the amount of the losses, an adiabatic cycle analysis is performed with the real properties of helium and the net enthaply flows through the two regenerators are numerically obtained. It is shown that the non-ideal gas losses could be as much as 8% in the heating capacity when the operating pressures are greater than 10MPa. The effects of the operating temperatures and the dead volumes on the loss are presented.

  • PDF

불균일한 풍속분포에 따른 응축기의 열전달 성능 변화 (Heat Transfer Performance Variation of Condenser due to Non-uniform Air Flow)

  • 이원종;정지환
    • 설비공학논문집
    • /
    • 제26권4호
    • /
    • pp.193-198
    • /
    • 2014
  • Heat transfer performance variation of a condenser caused by non-uniform distribution of air flow was investigated using a numerical simulation method. A heat exchanger used for a outdoor unit of a commercial heat pump system and represented by a numerical model was selected. Non-uniform profile of air-velocity was constructed by measuring the air velocity at various locations of the outdoor unit. Simulation was conducted for various refrigerant circuits and air flow conditions. Simulation results show that the heat transfer capacity was reduced depending on the air-flow rate and the refrigerant circuit configuration. It is also shown that the capacity reduction rate is increased as the average air velocity decreases.

에어컨의 냉방기간 에너지 효율 산출을 위한 실험적 연구 (Experimental Study on the Cooling seasonal Performance Factor of Room Air-conditioner)

  • 이홍원;문정호;배영돈;박종철
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.204-216
    • /
    • 1992
  • In most cases, EER(Energy Efficiency Ratio) is available to present energy efficiency of air-conditioners. But, EER is not adapt to measure energy efficiency at actual life environment because it is based on fixed temperature and humidity contditions. To overcome this disadvantage, there is need to introduce SEER(Seasonal Energy Efficiency Ratio) established at time varient temperature and humidity conditions. In this paper, SEER measurement method and conditions based on actual life environment of the country is introduced, and discussed SEER value about two air-conditioner type, that is, non inverter air-conditioner and inverter air-conditioner. As a result of, inverter air-conditioner was superior to non inverter air-conditioner at cooling seasonal energy efficiency.

  • PDF

매끈한 튜브의 입구 영역에서 난류유동에 의한 대류와 비회복사 (Non-gray Radiation with Turbulent Convection in the Entrance Region of a Smooth Tube)

  • 서태범
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.667-680
    • /
    • 1995
  • 튜브 내의 입구영역에서 난류 유동에 의한 대류와 비회복사(non-gray radiation)가 동시에 일어날 때의 열전달특성을 수치해석적으로 연구하였다. 작동유체는 이산화탄소, 수증기, 질소의 혼합가스라고 가정하였다. 지배방정식을 계산하기 위해 유한차분법이 이용되었고, 복사전달방정식을 이차편미분방정식으로 바꾸기 위해 P-1 근사법이 사용되었다. 그리고 혼합가스의 비회흡수계수(non-gray absorption coefficient)는 지수광폭밴드모형(exponential wide band model)을 이용해서 구하였다. 열전달특성에 대한 온도조건의 영향을 조사하기 위해 튜브의 축방향에 대한 평균 온도와 뉴셀트수(Nusselt number)의 변화를 몇 가지 다른 온도조건에 대해 나타내었다. 또한, 가스의 성분조성에 대한 영향을 조사하였으며, 이러한 결과에 기초해서 튜브 내에서 난류유동에 의한 대류와 비화복사가 동시에 일어날 때의 복사 뉴셀트수를 쉽게 예측할 수 있는 방법을 제시하였다.

  • PDF

수직원관형 흡수기의 흡수과정에 미치는 비흡수가스의 영향 (Effect of a non-absorbable gag on the absorption process in a vortical tube absorber)

  • 허기준;정은수;정시영
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.456-465
    • /
    • 1998
  • Effect of a non-absorbable gas on the absorption process in a vertical tube absorber was investigated numerically. The water vapor mined with air as the non-absorbable gas is absorbed into LiBr/water solution film. The flow is assumed to be laminar and fully developed in both liquid and gas phases. The diffusion and energy equations were solved in both phases to give the temperature and concentrations, from which heat and mass fluxes were determined. It was shown that the local absorption rate decreases as the mass fraction of air in water vapor increases. The vapor pressure of water at the liquid-vapor interface reduces significantly since the non-absorbable gas is accumulated near the interface. The effect of non-absorbable gases on absorption rate becomes larger as the mass flow rate of the vapor decreases. For small amount of non-absorbable gases the total absorption rate of water vapor increases as the mass flow rate of the vapor decreases. Total absorption rate increases as the mass flow rate of the vapor increases for large concentration of non-absorbables at the inlet of an absorber.

  • PDF

다이아몬드 컨디셔너를 이용한 ILD CMP에 관한 연구 (A Study on Interlayer Dielectric CMP Using Diamond Conditioner)

  • 서헌덕;김형재;김호윤;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.86-89
    • /
    • 2003
  • Chemical Mechanical Planarization(CMP) has been accepted as the most effective processes for ultra large scale integrated (ULSI) chip manufacturing. However, as the polishing process continues, pad pores get to be glazed by polishing residues, which hinder the supply of new slurry. And pad surface is ununiformly deformed as real contact distance. These defects make material removal rate(MRR) decrease with a number of polishied wafer. Also the desired within-chip planarity, within wafer non-uniformity(WIWNU) and wafer to wafer non-uniformity(WTWNU) arc unable to be achieved. So, pad conditioning in CMP Process is essential to overcome these defects. The eletroplated or brazed diamond conditioner is used as the conventional conditioning. And. allumina long fiber, the jet power of high pressure deionized water, vacuum compression. ultrasonic conditioner aided by cavitation effect and ceramic plate conditioner are once used or under investigation. But. these methods arc not sufficient for ununiformly deformed pad surface and the limits of conditioning effect. So this paper focuses on the characteristics of diamond conditioner which reopens glazed pores and removes ununiformly deformed pad away.

  • PDF

Effects of a Non-absorbable Gas on the Absorption Process in a Vertical Tube Absorber

  • Hur, ki-Joon;Jeong, Eun-Soo;Jeong, Si-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.69-78
    • /
    • 1999
  • Effects of a non-absorbable gas on the absorption process in a vertical tube absorber has been investigated numerically. The water vapor mixed with air is absorbed into LiBr/water solution film. The flow is assumed to be laminar and fully developed in both liquid and gas phases. The diffusion and energy equations were solved in both phases to give the temperature and concentrations, from which heat and mass fluxes were determined. The local absorption rate has been shown to decrease as the mass fraction of air in the water vapor increases. The vapor pressure of water at the liquid-vapor is interface reduced significantly since the non-absorbable gas accumulates near the interface. The effects of non-absorbable gases on absorption rate become larger as the mass flow rate of the vapor decreases. For a small amount of non-absorbable gases, the total absorption rate of water vapor increases as the mass flow rate of the vapor decreases. The total absorption rate increases as the mass flow rate of the vapor increases for large concentrations of non-absorbable gases at the inlet of an absorber.

  • PDF

확관을 고려한 불균일 내면가공관의 전열특성 (Heat Transfer Characteristics of the Non-Uniform Grooved Tube Considering Tube Expansion)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.553-559
    • /
    • 2012
  • A plate-fin heat exchanger is a type of heat exchanger widely used in air conditioners, and tubes and fins are tightly assembled by the mechanical expansion process of tubes. The tube expansion process deforms the grooves inside the tube, and the groove shapes also affect the adhesion between tubes and fins. In this study, the adhesion and heat transfer performance affected by the tube expansion of the non-uniform groove shape tube with different heights are investigated by both analysis and experiments. From the analysis method, it was shown that the contact pressure of non-uniform groove tube is higher than that of the uniform groove tube, and the most appropriate high groove number of the non-uniform groove tube is designed for the maximum contact pressure. From the experimental results, the decreasing rate of the condensation heat transfer coefficient is smaller in the non-uniform groove tube with different heights, compared to the conventional uniform groove tube. Also, the air-side heat transfer coefficient of the non-uniform groove tube with different heights is higher than that of the uniform groove tubes.

계통 연계 태양광 발전 시스템을 위한 Power Conditioning 시스템 (Power Conditioning System for Grid-connective PV Power Systems)

  • 이성룡;고성훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.38-41
    • /
    • 2002
  • Increasing of the use nonlinear power electronics equipments, power conditioning systems have been researched and developed for many years to compensate the harmonic disturbances and the reactive power. The main function of power conditioning systems is to reduce harmonic distortions, since extensive surveys quantify the problems associated with electric networks haying non-linear loads. The main function of power conditioner compensates the current instead of the voltage. Therefore the inverter used in power conditioner ismostley current controlled type. In this paper, the proposed current control algorithm is analyzed and discussed about how to design the controller which can apply power conditioning operation for grid-connective PV power system. And also proposed control system. To verify the proposed current control algorithm, a comprehensive evaluation with theoretical analysis, simulation results is presented.

  • PDF