• Title/Summary/Keyword: Non-Premixed Combustion

Search Result 105, Processing Time 0.02 seconds

Combustion Characteristics of a Turbulent Non-premixed Flame Using High Preheated Air (고온 예열 공기에 의한 난류 비예혼합 화염의 연소 특성)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.5
    • /
    • pp.561-568
    • /
    • 2003
  • An experiment using high preheated air in a turbulent non-premixed flame was performed to investigate the effects of high preheated air on the combustion characteristics. Combustion using high preheated and diluted air with flue gas is a new technology which enables NO emission to be reduced. In this study, Na was used as diluent and propane as fuel. Combustion characteristics, especially the distributions of the flame temperature, NO concentration and OH radical intensity were examined under the condition of 300 K, 600 K, 1000 K in terms of the combustion air temperature, and also under the condition of the dilution level from 21% to 13% in terms of oxygen concentration. As the preheated air temperature increased, it appeared that the flame length became shorter, maximum flame temperature increased, the reaction region moved to upstream, and NO concentration increased, but the flame temperature's fluctuation was reduced. In opposite, it was shown with decrement of oxygen concentration at the maximum temperature that both maximum value and the gradient of the flame temperature decreased, and NO emission also decreased considerably, but its fluctuation became larger, being inclined to be unstable.

Premixed VIStA Burner for an Once-Through Type Boiler (관류보일러를 위한 예혼합 VIStA 버너 개발)

  • Ahn, Joon;Kim, Hyouck-Ju;Choi, Kyu-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1013-1018
    • /
    • 2008
  • Vortex Inertial Staged Air (VIStA) burner for an once-through type boiler has been restored to the original premixed type to reduce nitrogen oxide (NOx) emission. The premixed version yields additional de-NOx effect by 20 ppm. The flame is formed closer to the wall at the 1st stage combustion chamber compared with the non-premixed one. The combustion characteristics are more sensitive to the air distribution for the premixed type, which necessitates proper optimization.

  • PDF

Numerical Study on Non-premixed Methane Flames in Twin-jet Counterflow (Twin-jet 대향류에서 메탄 비예혼합화염에 대한 수치적 연구)

  • Chun, K.W.;Kim, J.H.;Chung, C.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.49-56
    • /
    • 2004
  • A two-dimensional twin-jet counterflow system has been designed, in which two streams from two double-slit nozzles form a counterflow. This flow system enables one to systematically investigate various effects on non-premixed flames, including the non-premixed flame interaction, the edge flame behavior and the effect of curvature. Non-premixed flame interaction in the twin-jet counterflow system has been investigated numerically for methane fuel diluted with nitrogen. Three types of non-premixed flame(conventional counterflow flame, crossed twin-jet flame and petal shaped flame) were simulated depending on the combination of fuel/oxidizer supply to each nozzle. The extinction characteristics of non premixed methane flame in the twin-jet counterflow have been investigated numerically. The boundary of the existence of petal-shaped flames was identified for the twin-jet counterflow flames. Due to the existence of the unique petal-shaped flames, the extinction boundary for the twin-jet counterflow can be extended significantly compared to that for the conventional counterflow non-premixed flames, through the interaction of two flames. Through the comparison of the crossed twin-jet flame and the conventional counterflow flame, structure of the crossed twin-jet counterflow flame is analysed. Through the comparison of the petal shaped flame and the conventional counterflow flame, the extension of the extinction boundary for the twin-jet counterflow is investigated.

  • PDF

Numerical Study of PAH Formation Characteristics in Laminar Non-Premixed C2H4 Jet Flames (층류 비예혼합 C2H4 제트 화염장에서의 PAH 생성특성 해석)

  • Kim, Taehoon;Kim, Yongmo
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.133-134
    • /
    • 2014
  • The full transport equation approach for laminar non-premixed flame with detailed chemistry, soot and radiation has an advantage in accuracy and describing for emission pathway, but this approach requires the excessive computational cost especially for a higher-order hydrocarbon fuel flames. On the other hand, the standard flamelet model has an efficiency and accuracy for non-premixed flame, though this model is not suitable for simulating slow processor like soot and radiation in laminar non-premixed flame situation. To overcome this limitation, modified transient flamelet model is developed which coupled with two-equation soot model involved in soot formation and evolution mechanism such as nucleation, surface growth, oxidation and agglomeration.

  • PDF

Liftoff Mechanisms in Hydrogen Turbulent Non-premixed Jet Flames (수소 난류확산화염에서의 부상 메커니즘에 대한 연구)

  • Oh, Jeong-Seog;Kim, Mun-Ki;Choi, Yeong-Il;Yoon, Young-Bin
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.2
    • /
    • pp.26-33
    • /
    • 2007
  • To reveal the newly found liftoff height behavior of hydrogen jet, we have experimentally studied the stabilization mechanism of turbulent, lifted jet flames in a non-premixed condition. The objectives of the present research are to report the phenomenon of a liftoff height decreasing as increasing fuel velocity, to analyse the flame structure and behavior of the lifted jet, and to explain the mechanisms of flame stability in hydrogen turbulent non-premixed jet flames. The velocity of hydrogen was varied from 100 to 300m/s and a coaxial air velocity was fixed at 16m/s with a coflow air less than 0.1m/s. For the simultaneous measurement of velocity field and reaction zone, PIV and OH PLIF technique was used with two Nd:Yag lasers and CCD cameras. As results, it has been found that the stabilization of lifted hydrogen diffusion flames is related with a turbulent intensity, which means that combustion occurs at the point where the local flow velocity is balanced with the turbulent flame propagation velocity.

  • PDF

Effect of Oxygen Enriched Air on the Combustion Characteristics in a Coaxial Non-Premixed Jet (II) - Flame Structure and Temperature Distribution - (산소부화공기가 동축 비예혼합 제트의 연소특성에 미치는 영향 (II) - 화염의 구조와 온도분포 -)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Jang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.223-229
    • /
    • 2004
  • Combustion using oxygen enriched air is known as a technology which can increase thermal efficiency due to increase of the flame temperature. Flame shapes, schlieren photos, OH radical chemiluminescence and local flame temperature were examined as a function of OEC(Oxygen Enriched Concentration) in a coaxial non-premixed jet. With increase of OEC, flame length and width decreased, but its brightness increased significantly, and the size of vortices in the flame also increased. Especially, the reaction around the flame surface became active. The strong OH intensity appeared to be made and moved from middle stream to upper one with increase of OEC, which shows combustion reaction in the upper stream becomes more dominant In addition, the temperature distributions of the flames showed similar tendency with OH radical intensities. A flame with high temperature and strong stability was obtained with increasing OEC of the coflow.

The Combustion Characteristics at Primary Zone of Lean Premixed low NOx Combustor (저 NOx 희박연소기의 주연소영역에서의 연소특성 연구)

  • Lim, A.H.;Ahn, K.Y.;Kim, H.S.;Kim, Y.M.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.314-319
    • /
    • 2003
  • The concept of lean-premixed combustion in gas turbine combustor operation has become a standard in recent years as an effective means to meet stringent enviromental standards on NOx emissions. The combustion characteristics of 75 kW class lean premixed combustor were investigated at the conditions of high temperature and ambient pressure. The exit temperature and emissions of CO and NOx were measured at the center of exit plane. The high temperature air of $550K{\sim}650K$ was supplied through air preheater. As expected, experimental results indicate that NOx emission was increased and CO emission was decreased by increasing inlet air temperature. But CO emission measured at the center of exit plane was increased because of the non-uniform radial direction profiles. The Semi-Empirical Correlation method was applied to obtain the design point emissions of NOx and CO. Also the flame temperature, CO and NOx emissions were measured along the centerline of liner at 650K inlet air temperature to determine the position of dilution holes.

  • PDF

Modeling for Soot Formation Coupled with Detailed Chemistry in Laminar Pressurized Non-premixed Flames (층류 고압 비예혼합 화염에서 상세화학반응과 결합된 매연입자 생성 모델링)

  • Kim, Taehoon;Jeon, Sangtae;Kim, Yongmo
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.139-140
    • /
    • 2012
  • In laminar non-premixed flame situation, the flamelet model is not suitable for simulating slow processor like soot and radiation. Thus in this study, we overcome this limitation by using the transient flamelet model. Also, for soot formation on laminar non-premixed flame, transient flamelet coupled with two-equation soot model has been adopted due to its inherent advantages in terms of accuracy and availability. Based on numerical results, the detailed discussion has been made for the precise structure and soot formation processes in the pressurized methane air flames.

  • PDF

Detailed Spectroscopic Measurements of Chemiluminescence from Turbulent Premixed Flames in a Dump Combustor

  • Santavicca, D.A.;Lee, Jong-Guen
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.3
    • /
    • pp.19-26
    • /
    • 2004
  • This paper presents results of experimental study of flame chemiluminescence from turbulent premixed flames in a dump combustor. A detailed spectroscopic measurement of chemiluminescence over the wavelength of 405-495 nm is made for various flow conditions. No effect of turbulence on the relationship between chemiluminescence and heat release is found, suggesting the overall chemiluminescence intensity collected be used as a measure of overall heat release for non-oscillating stable flame. The background-$CO_2^*$ subtracted $CH^*$ chemiluminescence is found to be more sensitive to the equivalence ratio and premixedness of fuel-air mixture than $CO_2^*$ chemiluminescence.

  • PDF

Experimental Study on the Edge Flame Stabilization and its Structure Nearby Quenching Limits in a High Temperature Channel (고온 채널 내부 에지화염의 소염 한계 영역에서의 화염 안정화 및 구조에 관한 실험적 연구)

  • Lee, Min-Jung;Kim, Nam-Il
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • Edge flames have been interested as a basic structure that is concerned to flame stabilization and re-ignition of non-premixed flames. The edge flame consists of a lean premixed flame, a rich premixed flame, and a diffusion flame. In order to investigate fundamental structures of the edge flames at the conditions near the flammability limits, edge flames were stabilized within a heated narrow channel. Highly diluted partially premixed methane was used, and the flow rates of air and the partially premixed mixture were controlled. Various flame behaviors, including a transition between ordinary edge flames and premixed flames, were observed. Flame stabilization characteristics were examined as well. All flame stabilization conditions in this study showed a similar trend: characteristic time scales were inversely proportional to the equivalence ratio defined at the burner inlet. Finally, an interesting flame structure having a weak diffusion branch enveloped by a closed premixed branch was found near the flammability limits even in a fuel-air mixing layer. This structure was named as a "flame-drop" and the importance of this structure was first suggested.