• 제목/요약/키워드: Non-Isolation

검색결과 552건 처리시간 0.023초

Effects of insect-resistant genetically modified rice (Bt-9) cultivation on non-target insect diversity

  • Oh, Sung-Dug;Lim, Myung-Ho;Lee, Bumkyu;Yun, Doh-Won;Sohn, Soo-In;Chang, Ancheol;Park, Soon Ki;Suh, Sang Jae
    • 농업과학연구
    • /
    • 제45권1호
    • /
    • pp.28-37
    • /
    • 2018
  • This study was done to develop environmental risk assessments and a biosafety guide for insect-resistant genetically modified rice at a LMO (Living Modified Organism) isolation field. In the LMO quarantine area of Kyungpook National University, the species diversities and population densities of non-target insects found on insect-resistant genetically modified rice (Bt-9) resistant to Cnaphalocrocis medinalis and on non-GM rices (Dongjin and Ilmi) were investigated. The Bt-9 event was therefore evaluated under field conditions to detect possible impacts on the above ground insects and spiders. The study compared transgenic rice and two non-GM reference rices, Ilmi and Dongjin, at Gunwi in Southern Korea in 2016. Each rice was grown on three $18m^2$ plots with a randomized block design. A total of 4,243 individuals from 43 families and 9 orders were collected from the LMO isolation field. In the three types of rice fields, a total of 1,467 individuals from the insect-resistant genetically modified rice (Bt-9), 1,423 individuals from the Ilmi, and 1,353 individuals from the Dongjin were collected, respectively. There was no difference between the population densities of the non-target insect pests, natural enemies and other insects on the insect-resistant genetically modified rice (Bt-9) and non-GM rices. These results provide the diversity and population density of non-target insects for an environment risk assessment survey on insect-resistant genetically modified rice and could be used as a guideline to make a biosafety assessment method for genetically modified crops.

Structure's base design for earthquake protection numerical and experimental study

  • Alsaif, K.;Kaplan, H.
    • Structural Engineering and Mechanics
    • /
    • 제16권1호
    • /
    • pp.101-114
    • /
    • 2003
  • A base isolation system is proposed for earthquake protection of structures. The system incorporates spherical supports for the base, a specially designed spring-cam system to keep the base rigidly supported under normal condition and to allow it to move for the duration of the earthquake under the constraint of a spring with optimized non-linear characteristics. A single-story model is constructed to investigate the feasibility of the concept. Numerical simulations of the system as well as experimental results show that 95% reduction of the transmitted force to the structure can be achieved. To demonstrate the effectiveness of this isolation mechanism, the maximum dynamic bending stress developed at predetermined critical points within the frame of the structure is measured. Significant reduction of the dynamic stresses is obtained.

충남 천안아산지역에서 사육중인 육용오리의 리메렐라 감염율 조사 (A study on the prevalence of Riemerella anatipestifer from domestic ducks in Cheonan-Asan city)

  • 김수정;강수정;육심용
    • 한국동물위생학회지
    • /
    • 제31권3호
    • /
    • pp.339-345
    • /
    • 2008
  • This survey was carried out to investigate the infection rate of Riemerella anatipestifer from domestic ducks by isolation. A total of 145 samples (nasal swabs and carcasses) were collected from farms to examine the biochemical properties and antimicrobial susceptibility test from November 2006 to February 2008. Riemerella anatipestifer was isolated from 13 of 145 sample and isolation rate was higher in the ducks below 25 days (76%, 10/13 isolates) than those over 26 days (23%, 3/13). However, there was no significant difference in isolation rate between region. The biochemical properties of isolate were Gram negative (-), non-fermentative rod that grows fastidiously on routine media. In the test of antimicrobial drug susceptibility the isolates were susceptible to tetracycline(100%), enrofloxacin (77%), ampicillin (70%).

Study on Selective Media for Isolation of Entomopathogenic Fungi

  • Shin, Tae-Young;Choi, Jae-Bang;Bae, Sung-Min;Koo, Hyun-Na;Woo, Soo-Dong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제20권1호
    • /
    • pp.7-12
    • /
    • 2010
  • To determine the optimal isolation conditions of the entomopathogenic fungi from soil, we compared their growth characteristics with non-entomopathogenic fungi on agar media containing various concentrations of cooper (II) chloride ($CuCl_2$) or dodine. The result showed that dodine medium is more selective, and the optimal concentration of dodine is determined with $50{\mu}g$/ml. We could isolate several putative entomopathogenic fungi from soil using this, and identify them using ITS analysis. As a result, 64% fungi were identified as typical entomopathogenic fungi. This selective medium may be useful to the rapid and simple isolation of entomopathogenic fungi from soil.

면진 유체 저장 탱크의 지진취약도 분석 (Seismic Fragility Analysis of Base Isolated Liquid Storage Tank)

  • 안성문;최인길;전영선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.453-460
    • /
    • 2005
  • In this study, the seismic fragility analysis of a base isolated condensate storage tank installed in the nuclear power plant. The condensate storage tank is safety related structure in a nuclear power plant. The failure of this tank affect significantly to the core damage frequency of the nuclear power plants. The seismic analysis of the liquid storage tank was performed by the simple calculation method and the dynamic time storage analysis method. The convective and impulsive fluid mass is modeled as added masses proposed by several researchers. To evaluate the effectiveness of the isolation system, the comparison of HCLPF and core damage frequencies in non-isolated and isolated cases are carried out. It can be found from the results that the seismic isolation system increases the seismic capacity of a condensate storage tank and decreases the core damage frequency significantly.

  • PDF

한국산 자초 적색소의 분리 및 확인 (Isolation and Identification of Red Color Pigments from the Korean Lithospermum erythrorhizon)

  • 이제헌;오문헌;이희봉
    • 한국식품영양학회지
    • /
    • 제13권4호
    • /
    • pp.379-382
    • /
    • 2000
  • 한국산 자초 적색소의 추출조건과 적색소를 확인한 결과 자초에서 색소성분의 추출은 지용성 용제가 물에 비해서 추출력이 좋으며 특히 95% 에탄올이 적색소 추출에 효과적이었다. 적색소 성분의 추출은 침출 시간에 관계없이 비교적 고른 추출력을 보였으며 4$0^{\circ}C$이하에서 20분 정도 추출하면 적색소가 충분히 추출되었다. 한국산 자초뿌리의 적색소 성분을 분리하여, IR, NMR. GC/MS로 확인한 결과 대부분이 acetylshi-konin으로 동정되었다.

  • PDF

3차원 면진장치를 이용한 URANUS 액체금속로의 지진응답감소 (Reduction in Seismic Response of URANUS Liquid Metal Reactor by Using Three-Dimensional Seismic Isolator)

  • 이국희;김윤재;류강묵;황일순;유봉
    • 한국압력기기공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.30-39
    • /
    • 2011
  • URANUS (Ubiquitous, Robust, Accident-forgiving, Non-proliferating, Ultra-lasting and Sustainer) has been developed with 35MWe (100MWth) operating without primary coolant pump, capitalizing on natural circulation capability of lead-bismuth eutectic (LBE) for long-life small and robust power units. To ensure the structural integrity, the large safety margin against Safe Shutdown Earthquake, 0.3g, and furthermore the cost effectiveness for URANUS, three-dimensional seismic base isolation design has been developed. The analytical model has been developed and seismic time history analyses have been carried out. The advantage for using three-dimensional seismic base isolation for URANUS has been discussed.

CMP 연마를 통한 STI에서 결함 감소 (A Study of Chemical Mechanical Polishing on Shallow Trench Isolation to Reduce Defect)

  • 백명기;김상용;김창일;장의구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.501-504
    • /
    • 1999
  • In the shallow trench isolation(STI) chemical mechanical polishing(CMP) process, the key issues are the optimized thickness control within- wafer-non-uniformity, and the possible defects such as nitride residue and pad oxide damage. These defects after STI CMP process were discussed to accomplish its optimum process condition. To understand its optimum process condition, overall STI related processes including reverse moat etch, trench etch, STI filling and STI CMP were discussed. It is represented that the nitride residue can be occurred in the condition of high post CMP thickness and low trench depth. In addition there are remaining oxide on the moat surface after reverse moat etch. It means that reverse moat etching process can be the main source of nitride residue. Pad oxide damage can be caused by over-polishing and high trench depth.

  • PDF

Seismic Isolation Systems Incorporating with RC Core Walls and Precast Concrete Perimeter Frames -Shimizu Corporation Tokyo Headquarter-

  • Shimazaki, Dai;Nakagawa, Kentaro
    • 국제초고층학회논문집
    • /
    • 제4권3호
    • /
    • pp.181-189
    • /
    • 2015
  • Shimizu Corporation Tokyo Headquarters, one of the city's leading office buildings, features many pioneering technologies that contribute to a sustainable society through environmental stewardship and a sophisticated disaster management facility. In terms of structural engineering, a seismic isolation system incorporating reinforced concrete core walls and precast concrete perimeter frames create a robust structure in the event of a large earthquake. In addition to the seismic resistance of the structure, several pioneering construction methods and materials are adopted. This office building can serve as a basis for new design and construction approaches and methodologies to ensure safe and economical structures.

Base-isolated building with high-damping spring system subjected to near fault earthquakes

  • Tornello, Miguel Eduardo;Sarrazin, Mauricio
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.315-340
    • /
    • 2012
  • There are many types of seismic isolation devices that are being used today for structural control of earthquake response in buildings. The most commonly used are sliding bearings and elastomeric bearings, the latter with or without lead core. An alternative solution is the use of steel springs combined with viscoelastic fluid dampers, which is the case discussed in this paper. An analytical study of a three-story building supported on helical steel springs and viscoelastic fluid dampers, GERB Control System (GCS), subjected to near-fault earthquakes is presented. Several earthquakes records have been obtained by the acceleration network installed in the isolated building and in its non-isolated twin since they were finished. These experimental results are analysed and discussed. The aim is to show that the spring-based system can be an alternative for base isolation of small building located near active faults.