• Title/Summary/Keyword: Noise management

Search Result 844, Processing Time 0.028 seconds

Establishment on Management Plan of Environmental Noise with Noise Map (소음지도를 활용한 환경소음 관리계획 수립)

  • Sun, Hyosung
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.2
    • /
    • pp.123-131
    • /
    • 2011
  • The objective of this study is to prepare the effective management plan of environmental noise with a noise map, and the guideline on the management plan of environmental noise was suggested through the review of existing application examples. The management plan of environmental noise with a noise map includes the practical contents in the stages of subdivision of management areas, establishment of reduction measures, opinion collection, post investigation, and reformulation of management plan. First, the classification of management regions is performed considering the excess degree of noise standard and the facility type in the phase of subdivision of management areas. Second, the optimal management plan is established through the investigation of regional characteristics and various noise reduction measures in the phase of establishment of reduction measures, which includes the examination of noise reduction effects with a noise map and the budget planning with the costing of noise reduction measures. Third, the opinion survey with a local resident and a expert is carried out in order to prove the validity of the management plan in the phase of opinion collection, and the management plan is modified with gathered opinions. Fourth, the post examination plan with noise measurement is performed in order to verify the real effect of noise reduction measures according to the management plan in the phase of post investigation. Finally, the amendment of the management plan as well as the improvement of a noise map is carried out at a regular cycle in the phase of reformulation of management plan.

Development of Management System for Measurement and Characteristic analysis, Evaluation of Environmental Noise (인터넷 통신이용 실시간 환경소음 측정 및 특성분석, 평가ㆍ관리 시스템 개발)

  • 유동준;이상권
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.515-520
    • /
    • 2003
  • In these days, the civil appeal and dispute about environmental noise grows larger every year. But there are not suitable systems for measurement and management of environmental noise. This paper proposes environmental noise measurement, characteristic analysis and evaluation, management system using Internet. We can measure and manage the environmental noise also, analyze characteristics of noise by the environmental noise management system using Internet.

  • PDF

Actual Status and Improvement Method of Maintenance Management for Noise Barrier (방음벽의 유피관리 실태 및 개선방안에 관한 연구)

  • Kim, Heung-Sik;Huh, Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.7
    • /
    • pp.570-576
    • /
    • 2003
  • Noise harriet Is used for noise reduction method of traffic noise. The length and the total cost of that are increased In this national area. But. a maintenance management of noise barrier is not systematic. and the guideline of that is not prepared for maintenance manual. The situations of existed installation and management of noise barriers Installed at 3.619 positions were investigated by questionnarie and direct field survey. And comparisons with foreign management guideline of noise harrier were carried out. The results show that the improvement methods of maintenance management system such as practical checklist and required Items for management of noise barrier were suggested.

Improvement for Maintenance Management System of Noise Barrier (방음벽 유지관리시스템 개선 방안에 관한 연구)

  • Kim, Heung-Sik;Huh, Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.214-218
    • /
    • 2003
  • Noise barrier is used for noise reduction method of traffic noise. The length and the total cost of that are increased in this national area. But, a maintenance management of noise barrier is not systematic, and the guideline of that is not prepared for maintenance mannual. The situations of existed installation and management of noise barriers installed at 3,619 positions were investigated by questionnarie and direct field survey. And comparisons with foreign management guideline of noise barrier were carried out. The results show that the improvement methods of maintenance management system such as practical checklist and required items for management of noise barrier were suggested.

  • PDF

Development of Management System for Measurement and Characteristic Analysis, Evaluation of Environmental Noise (인터넷 통신을 이용한 환경소음 측정 분석 및 평가 관리 시스템의 개발)

  • Yu, Dong-Jun;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.306-312
    • /
    • 2005
  • In these days, the people living in the urban suffer from the environmental noise because the number of cars increases in the city, and a lot of new industrial complex is made in the urban every year. But there is no suitable system for measurement and management of environmental noise. Therefore, in this research, a new system for the measurement and characteristic analysis, evaluation, management of environmental noise using Internet communication is developed. The system includes the environmental noise measurement equipment and the controller for the noise measurement and analysis, evaluation, management.

Development of Management System for Measurement and Characteristic analysis, Evaluation of Environmental Noise (인터넷 통신을 이용한 환경소음 측정 분석 및 평가 관리 시스템의 개발)

  • Yu, Dong-Jun;Lee, Sang-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.160-165
    • /
    • 2004
  • In these days, the people living in the urban is suffer from the environmental noise because the number of car increase in the city, and a lot of new industrial complex is made in the urban every. But there is no suitable system for measurement and management of environmental noise. Therefore, in this research, a new system for the measurement, characteristic analysis and evaluation, management of environmental noise using Internet communication is developed. The system includes the environmental noise measurement equipment and the controller for the noise measurement, analysis and evaluation, management.

  • PDF

Developing noise prediction software for Improvement of the construction noise management (공사장 소음 관리 효율화를 위한 소음예측프로그램 개발)

  • An, Jang-Ho;Lee, Jun-Seo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.155-156
    • /
    • 2009
  • Construction companies can easily understand present noise condition of their construction site via C-Noise. C-Noise is noise simulation software that simple to use. Construction companies spend time and cost for public complaints about construction noise. Construction site noise management using noise simulation software like C-Noise can reduce public complaint. achieve cost reduction to treat it.

  • PDF

A Study for the Reduction of Railway Noise (철도운행선의 생활소음 저감방안 연구)

  • Han, Du-Seob;Kim, Hee-Man;Lee, Sang-Bae;Lee, Jin-Ho;Kang, Sung-Hae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.673-676
    • /
    • 2007
  • These days, the damage of noise has increased seriously by rapid change of life style because of the centralization of urban population, and the rapid increase of traffic. The Ministry of Environment has emphasis on the systematic management about the noise of daily life and the close connection of daily noise management policy with relevant ministries, and put into practice "the master plan of lessening the noise of daily life" from year 2006. This study tried to find out the reduction methods and the effective management of railway noise in the action plan of railway part of "the master plan of lessening the noise of daily life". According to this study, railway noise can be reduced greatly by taking action of railway detail plans. The cause of railway noise varies by rolling stock, track and more, so the reduction methods of railway noise can be studied specially, scientifically and constantly in every field.

  • PDF

Comparision Between Noise Levels of Hospital Wards and the Nurses Efforts for Noise Management in Selected General Hospital (종합병원 병동별 간호사실의 소음정도와 간호사실들의 소음인지도 및 소음관리노력 비교)

  • Jung, Hyun-Wook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.174-182
    • /
    • 2001
  • This study was performed to find out the differences between noise levels of hospital wards and the nurses efforts for noise management in some general hospitals. The hospital wards selected were the intensive care unit(ICU), the emergency room(ER), the nursery room(NR), the internal medicine(IM), the general surgery(GS) among the 5 general hospitals located in Seoul. The data were collected from August 3 to September 13, 1999 through questionnaire survey and noise measurement in each nursing station of hospital wards. Data analysis was done by SPSS 8.0 package among the 305 questionnaires and 24 hours monitored noise levels. Frequency, Chi-square and ANOVA test were used. The study results were as belows: 1. The noise level measured by 24 hours monitoring survey were exceeded on the standard limit in all the hospital wards. Data also showed that noise levels were significantly different in each ward among the three shifts working duties. 2. The subjects were all female nurses. They were mostly working in the ICU ward(28.9%). They were 26~30 years old (43.9%), junior college graduates(57.0%), working for 1~5 years(55.1%) as staff-nurse(85.6%). There were no significant differences between hospital wards and general characteristics of nurses. 3. The noise levels perceived by nurses were regarded as 'Highly noisy'(56.4%), especially during the 11:30 and 15:30 (30.2%) o'clock. Data also showed that noise education was not ever given to nurses(89.9%). Nurses also responded that they hardly put an effort to reduce noise level(54.8%). However, there were significant differences between wards and noisy working time, experience of noise education and level of effort for noise reduction. 4. Nurses also perceived the ventilator alarm and EKG-alarm as the most disturbing sounds in the ICU, human voice and telephone ringing in the ER, human voice and EKG-alarming in the NR, human voices and telephone ringing in IM and GS both wards respectively in order. There were significant differences between hospital wards and noise making factors. 5. Nurses were shown that they regarded highly 'Sound reduction of the human voice', 'Careful handling on medical instruments', and 'Immediate appliances on alarming materials' as the practical method for noise management. There were significant differences between hospital wards and behavioral practical efforts for noise management. According to that results, the statistical differences were shown in the 24 hour monitored noise levels in each ward. Also, nurses perceived the noise severity differently and they approached variously on the practical efforts for noise reduction in each ward. Thus, author thinks that concrete and systematic endeavor will be necessary for noise reduction and management in hospitals for better working and healing environment for both of patients and staffs.

  • PDF

Propose to new Method determining level of Noise Factor of Taguchi Method (다구찌 기법의 잡음인자 수준 정하는 기법 제안)

  • Ree, Sang-Bok
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2009.10a
    • /
    • pp.317-323
    • /
    • 2009
  • In this paper, we propose new methods which is to determine level of noise factor. Even Taguchi give level of noise factor which is best(or maximum) and worst(or minimum) condition, we give level of noise factor which is representative value by observing noise factor frequency. Sometimes level of noise factor is given one, two and three. We know this method is more fit in real fields.

  • PDF