• Title/Summary/Keyword: Noise level measuring methods

Search Result 37, Processing Time 0.023 seconds

A Study on The Range Estimation of Underwater Acoustic Source using FDOA and TDOA of Multipath Signals (다중경로 신호의 도달 주파수와 시간 차를 이용한 수중음원 거리 추정 연구)

  • Son, Yoon-Jun;Son, Gi-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.311-318
    • /
    • 2021
  • Underwater, signals are transmitted by sound waves. Sound waves are transmitted through a multipath, either directly or through reflection, due to the variety of underwater environmental characteristics. In such diverse and complex underwater environments, tests must be conducted to determine the extent of the hazard from the survivability and pitfalls of submarines by measuring the underwater radiated noise. Usually, the sound source level measurement of underwater radiated noise should be made within the closest point (CPA: Closest Point of Approach) ± a few meters between the measurement sensor and the submarine. In this study, FDOA and TDOA methods were proposed to estimate the underwater source range. A simulation based on the underwater channel model confirmed the performance of the proposed method.

A Study on Skin Status with Acoustic Measurements of Skin Friction Noise (피부 마찰 소음 측정을 통한 피부 상태 연구)

  • Chang, Yun Hee;Seo, Dae Hoon;Koh, A Rum;Kim, Sun Young;Lim, Jun Man;Han, Jong Seup;Lee, Sang Hwa;Park, Sun Gyoo;Kim, Yang Han
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Efficacy of cosmetics has been mainly evaluated by qualitative and quantitative methods based on visual sense, tactile sense and skin structure until now. In this study, we suggested a novel evaluation method for skin status based on sound; measuring and analyzing the rubbing noise generated by applying cosmetics. First, the rubbing noise was measured at a close range by a high-sensitivity microphone in anechoic environment, and the noises were analyzed by 1/3 octave band analysis in frequency-domain. Three conditions, 1) before washing, 2) after washing and 3) after application of cosmetics, were compared. As a result, sound pressure level (SPL) of rubbing noise after washing was larger than that of before washing, and the SPL of rubbing noise after cosmetic application was the smallest. Furthermore, the energy of rubbing noise after application was higher than that of the before and after washing conditions in a low frequency band (lower than 2 kHz region). Conversely, the energy of rubbing noise after application was much lower than the others in a high-frequency band (upper than 2 kHz region). This change of energy distribution was described as a balloon-skin model. High SPL in the low frequency region after the cosmetic applications was due to the increase of "flexibility index", while SPL in the high frequency region significantly decreased because of the attenuation which is related to "softness index". Therefore, we developed two indices based on the spectrum-energy difference for evaluating skin conditions. This proposed method and indices were verified via skin flexibility and roughness measurement using cutometer and primos respectively. These results suggest that acoustic measurement of skin friction noise may be a new skin status evaluation method.

Measuring the Degree of Content Immersion in a Non-experimental Environment Using a Portable EEG Device

  • Keum, Nam-Ho;Lee, Taek;Lee, Jung-Been;In, Hoh Peter
    • Journal of Information Processing Systems
    • /
    • v.14 no.4
    • /
    • pp.1049-1061
    • /
    • 2018
  • As mobile devices such as smartphones and tablet PCs become more popular, users are becoming accustomed to consuming a massive amount of multimedia content every day without time or space limitations. From the industry, the need for user satisfaction investigation has consequently emerged. Conventional methods to investigate user satisfaction usually employ user feedback surveys or interviews, which are considered manual, subjective, and inefficient. Therefore, the authors focus on a more objective method of investigating users' brainwaves to measure how much they enjoy their content. Particularly for multimedia content, it is natural that users will be immersed in the played content if they are satisfied with it. In this paper, the authors propose a method of using a portable and dry electroencephalogram (EEG) sensor device to overcome the limitations of the existing conventional methods and to further advance existing EEG-based studies. The proposed method uses a portable EEG sensor device that has a small, dry (i.e., not wet or adhesive), and simple sensor using a single channel, because the authors assume mobile device environments where users consider the features of portability and usability to be important. This paper presents how to measure attention, gauge and compute a score of user's content immersion level after addressing some technical details related to adopting the portable EEG sensor device. Lastly, via an experiment, the authors verified a meaningful correlation between the computed scores and the actual user satisfaction scores.

A Study on the Noise Reduction Method for Data Transmission of VLBI Data Processing System (VLBI 자료처리 시스템의 데이터 전송에서 잡음방지에 관한 연구)

  • Son, Do-Sun;Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Jung, Jin-Seung;Oh, Chung-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.4
    • /
    • pp.333-340
    • /
    • 2011
  • KJJVC(Korea-Japan Joint VLBI Correlator) was installed at the KJCC(Korea-Japan Correlation Center) and has been operated by KASI(Korea Astronomy and Space Science Institute) from 2009. KJNC is able to correlate the VLBI observed data through KVN(Korean VLBI Network), VERA(VLBI Exploration of Radio Astrometry), and JVN(Japanese VLBI Network) and its joint network array. And it is used exclusively as computer in order to process the observed data for the scientific purpose KJJVC used the VSI(VLBI Standard Interface) as the VLBI international standard at the data input-output specification between each component. Especially, for correlating the observed data, the data is transmitted with 1024Mbps speed between Mark5B high-speed playback and RVDB(Raw VLBI Data Buffer). The EMI(Electromagnetic lnterference), which is occurred by data transmission with high-speed, cause the data loss and the loss occurrence is frequently often for long transmission cable. Finally it will be caused the data recognition error by decreasing the voltage level of digital data signal. In this paper, in order to minimize the data loss by measuring the EMI noise level in transmission of the VSI specification, the 3 methods such as 1) RC filtering method, 2) lmpedance matching using Microstrip line, and 3) Signal buffering method using Differential line driver, were proposed. To verify the effectiveness of each proposed method, the performance evaluation was conducted by implementing and simulations for each method. Each proposed method was effectively confirmed as the high-speed data transmission of the VSI specification.

The evaluate the usefulness of various CT kernel applications by PET/CT attenuation correction (PET/CT 감쇠보정시 다양한 CT Kernel 적용에 따른 유용성 평가)

  • Lee, Jae-Young;Seong, Yong-Jun;Yoon, Seok-Hwan;Park, Chan-Rok;Lee, Hong-Jae;Noh, Kyung-Wun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.37-43
    • /
    • 2017
  • Purpose Recently PET/CT image's attenuation correction is used CTAC(Computed Tomgraphy Attenuation Correction). it can quantitative evaluation by SUV(Standard Uptake Value). This study's purpose is to evaluate SUV and to find proper CT kernel using CTAC with applied various CT kernel to PET/CT construction. Materials and Methods Biograph mCT 64 was used for the equipment. We were performed on 20 patients who had examed at our hospital from february through March 2017. Using NEMA IEC Body Phantom, The data was reconstructed PET/CT images with CTAC appiled various CT kernel. ANOVA was used to evaluated the significant difference in the result. Results The result of measuring the radioactivity concentration of Phantom was B45F 96% and B80F 6.58% against B08F CT kernel, each respectively. the SUVmax increased to B45F 0.86% and B80F 6.54% against B08F CT kernel, In case of patient's parts data, the Lung SUVmax increased to B45F 1.6% and B80F 6.6%, Liver SUVmax increased to B45F 0.7% and B80F 4.7%, and Bone SUVmax increased to B45F 1.3% and B80F 6.2%, respectively. As for parts of patient's about Standard Deviation(SD), the Lung SD increased to B45F 4.2% and B80F 15.4%, Liver SD increased to B45F 2.1% and B80F 11%, and Bone SD increased to B45F 2.3% and B80F 14.7%, respectively. There was no significant difference discovered in three CT kernel (P >.05). Conclusion When using increased noise CT kernel for PET/CT reconstruction, It tends to change both SUVmax and SD in ROI(region of interest), Due to the increase the CT kernel number, Sharp noise increased in ROI. so SUVmax and SD were highly measured, but there was no statistically significant difference. Therefore Using CT kernel of low variation of SD occur less variation of SUV.

  • PDF

A Polarization-based Frequency Scanning Interferometer and the Measurement Processing Acceleration based on Parallel Programing (편광 기반 주파수 스캐닝 간섭 시스템 및 병렬 프로그래밍 기반 측정 고속화)

  • Lee, Seung Hyun;Kim, Min Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.253-263
    • /
    • 2013
  • Frequency Scanning Interferometry(FSI) system, one of the most promising optical surface measurement techniques, generally results in superior optical performance comparing with other 3-dimensional measuring methods as its hardware structure is fixed in operation and only the light frequency is scanned in a specific spectral band without vertical scanning of the target surface or the objective lens. FSI system collects a set of images of interference fringe by changing the frequency of light source. After that, it transforms intensity data of acquired image into frequency information, and calculates the height profile of target objects with the help of frequency analysis based on Fast Fourier Transform(FFT). However, it still suffers from optical noise on target surfaces and relatively long processing time due to the number of images acquired in frequency scanning phase. 1) a Polarization-based Frequency Scanning Interferometry(PFSI) is proposed for optical noise robustness. It consists of tunable laser for light source, ${\lambda}/4$ plate in front of reference mirror, ${\lambda}/4$ plate in front of target object, polarizing beam splitter, polarizer in front of image sensor, polarizer in front of the fiber coupled light source, ${\lambda}/2$ plate between PBS and polarizer of the light source. Using the proposed system, we can solve the problem of fringe image with low contrast by using polarization technique. Also, we can control light distribution of object beam and reference beam. 2) the signal processing acceleration method is proposed for PFSI, based on parallel processing architecture, which consists of parallel processing hardware and software such as Graphic Processing Unit(GPU) and Compute Unified Device Architecture(CUDA). As a result, the processing time reaches into tact time level of real-time processing. Finally, the proposed system is evaluated in terms of accuracy and processing speed through a series of experiment and the obtained results show the effectiveness of the proposed system and method.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF