• Title/Summary/Keyword: Noise level evaluation

Search Result 439, Processing Time 0.029 seconds

Laboratory and Field Performance Evaluation of Acryl Resin Based Solar Radiation Reflective Pavement (아크릴 수지를 이용한 차열성 포장의 실내 및 현장 공용성 평가)

  • So, Kyung-Rock;Lee, Hyun-Jong;Baek, Jong-Eun;Lee, Sang-Yum
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.19-28
    • /
    • 2011
  • This study developed a solar radiation reflection pavement, so called a cool pavement, to lessen the urban heat island effect by coating a pavement surface with acrylic resins mixed with light-colored pigments. From a laboratory test, simulating solar heating process in pavements, the cool pavement reduced more than $12^{\circ}C$ of pavement temperature at $60^{\circ}C$ compared to a control porous pavement. With the increase of the mixing ratio of the pigments to acrylic resins, the temperature reduction effect increased, but its workability became worse due to higher viscosity. As a result, an appropriate mixing ratio was determined as 15%. The cool pavement had better durability than the control pavement: One quarter of Catabro loss and twofold dynamic stability. Its adhesion was also higher enough not to be debonded under traffic loading. In-situ noise and friction tests conducted in two field sites showed that the cool pavement reduced its noise level by 3.7dB in average and increased its friction level by 30% compared to the control pavement. The permeability of the cool pavement was little lower than the control pavement, but higher enough to satisfy the minimum requirement for porous pavements.

A Study on the Noise Reduction Method for Data Transmission of VLBI Data Processing System (VLBI 자료처리 시스템의 데이터 전송에서 잡음방지에 관한 연구)

  • Son, Do-Sun;Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Jung, Jin-Seung;Oh, Chung-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.4
    • /
    • pp.333-340
    • /
    • 2011
  • KJJVC(Korea-Japan Joint VLBI Correlator) was installed at the KJCC(Korea-Japan Correlation Center) and has been operated by KASI(Korea Astronomy and Space Science Institute) from 2009. KJNC is able to correlate the VLBI observed data through KVN(Korean VLBI Network), VERA(VLBI Exploration of Radio Astrometry), and JVN(Japanese VLBI Network) and its joint network array. And it is used exclusively as computer in order to process the observed data for the scientific purpose KJJVC used the VSI(VLBI Standard Interface) as the VLBI international standard at the data input-output specification between each component. Especially, for correlating the observed data, the data is transmitted with 1024Mbps speed between Mark5B high-speed playback and RVDB(Raw VLBI Data Buffer). The EMI(Electromagnetic lnterference), which is occurred by data transmission with high-speed, cause the data loss and the loss occurrence is frequently often for long transmission cable. Finally it will be caused the data recognition error by decreasing the voltage level of digital data signal. In this paper, in order to minimize the data loss by measuring the EMI noise level in transmission of the VSI specification, the 3 methods such as 1) RC filtering method, 2) lmpedance matching using Microstrip line, and 3) Signal buffering method using Differential line driver, were proposed. To verify the effectiveness of each proposed method, the performance evaluation was conducted by implementing and simulations for each method. Each proposed method was effectively confirmed as the high-speed data transmission of the VSI specification.

Image Evaluation for A Kind of Patient Fixing Pad in 64 Multi-Channel Detector Computed Tomograph (64 다중채널 검출기 전산화단층촬영에서 환자고정자 재질에 대한 영상평가)

  • Kim, Kee-Bok;Goo, Eun-Hoe
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.1
    • /
    • pp.89-95
    • /
    • 2016
  • The purpose of this experiment intend to evaluate the quality of the image based on the orbit and basal ganglia with high radiosensitivity for the noise, SNR and dose using the five kinds patient fixing pad in brain phantom MDCT(BrillianceTM CT 64 slice, PHILIPS, Netherward). The noise had a higher values in AP than those of others, but the SNR was lower in AP than those of others. The SNR was higher in UP than those of RP, PP, SP and AP. The UP, RP and PP were no statistically significant(p>0.05), whereas it was significant difference between UP, RP, PP and SP, AP(p<0.05). This is causes of the noise difference is generated due to the differences in the radiation absorption dose in accordance with each the component of the absorbed dose level of the detector according to the reference line and each of SOML when the radiation exposured. The CTDIvol(mGy) and DLP of orbit and basal ganglia were 56.95, 911.50, respectively. There is no difference between both mean dose. In conclusion, it is possible to distinguish among a kind of 5 patient fixing pad by using brain phantom MDCT. Overall, patient fixing pad of UP, RP and PP based on a brain phantom MDCT can provide useful information.

A study on the feasibility evaluation technique of urban utility tunnel by using quantitative indexes evaluation and benefit·cost analysis (정량적 지표평가와 비용·편익 분석을 활용한 도심지 공동구의 타당성 평가기법 연구)

  • Lee, Seong-Won;Chung, Jee-Seung;Na, Gwi-Tae;Bang, Myung-Seok;Lee, Joung-Bae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.61-77
    • /
    • 2019
  • If a new utility tunnel is planned for high density existing urban areas in Korea, a rational decision-making process such as the determination of optimum design capacity by using the feasibility evaluation system based on quantitative evaluation indexes and the economic evaluation is needed. Thus, the previous study presented the important weight of individual higher-level indexes (3 items) and sub-indexes (16 items) through a hierarchy analysis (AHP) for quantitative evaluation index items, considering the characteristics of each urban type. In addition, an economic evaluation method was proposed considering 10 benefit items and 8 cost items by adding 3 new items, including the effects of traffic accidents, noise reduction and socio-economic losses, to the existing items for the benefit cost analysis suitable for urban utility tunnels. This study presented a quantitative feasibility evaluation method using the important weight of 16 sub-index items such as the road management sector, public facilities sector and urban environment sector. Afterwards, the results of quantitative feasibility and economic evaluation were compared and analyzed in 123 main road sections of the Seoul. In addition, a comprehensive evaluation method was proposed by the combination of the two evaluation results. The design capacity optimization program, which will be developed by programming the logic of the quantitative feasibility and economic evaluation system presented in this study, will be utilized in the planning and design phases of urban community zones and will ultimately contribute to the vitalization of urban utility tunnels.

Optimization of Tube Voltage according to Patient's Body Type during Limb examination in Digital X-ray Equipment (디지털 엑스선 장비의 사지 검사 시 환자 체형에 따른 관전압 최적화)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.379-385
    • /
    • 2017
  • This study identifies the optimal tube voltages depending on the changes in the patient's body type for limb tests using a digital radiography (DR) system. For the upper-limp test, the dose area product (DAP) was fixed at $5.06dGy{\ast} cm^2$, and for the lower-limb test, the DAP was fixed at $5.04dGy{\ast} cm^2$. Afterwards, the tube voltage was changed to four different stages and the images were taken three times at each stage. The thickness of the limbs was increased by 10 mm to 30 mm to change in the patient's body type. For a quantitative evaluation, Image J was used to calculate the contrast to noise ratio (CNR) and signal to noise ratio (SNR) among the four groups, according to the tube voltage. For statistical testing, the statistically significant differences were analyzed through the Kruskal-Wallis test at a 95% confidence level. For the qualitative analysis of the images, the pre-determined items were evaluated based on a 5-point Likert scale. In both upper-limb and lower-limb tests, the more the tube voltage increased, the more the CNR and SNR of the images decreased. The test on the changes depending on the patient's body shape showed that the more the thickness increased, the more the CNR and SNR decreased. In the qualitative evaluation on the upper limbs, the more the tube voltage increased, the more score increased to 4.6 at the maximum of 55kV and 3.6 at 40kV, respectively. The mean score for the lower limbs was 4.4, regardless of the tube voltage. The more either the upper or lower limbs got thicker, the more the score generally decreased. The score of the upper limps sharply dropped at 40kV, whereas that of the lower limps sharply dropped at 50kV. For patients with a standard thickness, the optimized images can be obtained when taken at 45kV for the upper limbs, and at 50kV for the lower limbs. However, when the thickness of the patient's limbs increases, it is best to set the tube voltage at 50 kV for the upper limbs and at 55 kV for the lower limbs.

Detection of Spoilage Odors in Beef Using R-index and Pseudomonas Growth during Storage (쇠고기의 저장 중 R-index에 의한 부패취 발생시점과 Pseudomonas의 증식과의 비교 분석)

  • Byeon, Ko Eun;Park, Han Jo;An, Soo Rim;Hong, Kwang Won;Min, Sang Gi;Chung, Ku Young;Won, Kee Hoon;Lee, Seung Ju
    • Food Engineering Progress
    • /
    • v.13 no.2
    • /
    • pp.117-121
    • /
    • 2009
  • Detection of spoilage odors from beef during storage was investigated using sensory evaluation with R-index, and microbial assay for Pseudomonas. Beef samples were tested to measure the flavor changes, which were converted to R-index, and the Pseudomonas levels during storage. There was a steep rise in R-index until 36 hr after storage at 25$^{\circ}C$, and then a gentle rise from 48 hr, whereas, there was a steady rise in R-index in the whole range of storage at 5$^{\circ}C$. Detection time of spoilage odors according to R-index was statistically analyzed at $\alpha$=5% to be at 30.92${\pm}$3.47 hr and 169.80${\pm}$11.27 hr for 25 and 5$^{\circ}C$ storage, respectively, and analyzed at $\alpha$=1% to be 34.80${\pm}$4.01 and 176.41${\pm}$9.89 hr for 25 and 5$^{\circ}C$ storage, respectively. At the detection times of spoilage odors, the Pseudomonas levels were found to be almost the same, but less than 6-7 log CFU/g generally known as a standard level at occurrence of spoilage odors in beef. This indicated that some other factors than the Pseudomonas reactions could be associated with generation of spoilage odors.

The evaluate the usefulness of various CT kernel applications by PET/CT attenuation correction (PET/CT 감쇠보정시 다양한 CT Kernel 적용에 따른 유용성 평가)

  • Lee, Jae-Young;Seong, Yong-Jun;Yoon, Seok-Hwan;Park, Chan-Rok;Lee, Hong-Jae;Noh, Kyung-Wun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.37-43
    • /
    • 2017
  • Purpose Recently PET/CT image's attenuation correction is used CTAC(Computed Tomgraphy Attenuation Correction). it can quantitative evaluation by SUV(Standard Uptake Value). This study's purpose is to evaluate SUV and to find proper CT kernel using CTAC with applied various CT kernel to PET/CT construction. Materials and Methods Biograph mCT 64 was used for the equipment. We were performed on 20 patients who had examed at our hospital from february through March 2017. Using NEMA IEC Body Phantom, The data was reconstructed PET/CT images with CTAC appiled various CT kernel. ANOVA was used to evaluated the significant difference in the result. Results The result of measuring the radioactivity concentration of Phantom was B45F 96% and B80F 6.58% against B08F CT kernel, each respectively. the SUVmax increased to B45F 0.86% and B80F 6.54% against B08F CT kernel, In case of patient's parts data, the Lung SUVmax increased to B45F 1.6% and B80F 6.6%, Liver SUVmax increased to B45F 0.7% and B80F 4.7%, and Bone SUVmax increased to B45F 1.3% and B80F 6.2%, respectively. As for parts of patient's about Standard Deviation(SD), the Lung SD increased to B45F 4.2% and B80F 15.4%, Liver SD increased to B45F 2.1% and B80F 11%, and Bone SD increased to B45F 2.3% and B80F 14.7%, respectively. There was no significant difference discovered in three CT kernel (P >.05). Conclusion When using increased noise CT kernel for PET/CT reconstruction, It tends to change both SUVmax and SD in ROI(region of interest), Due to the increase the CT kernel number, Sharp noise increased in ROI. so SUVmax and SD were highly measured, but there was no statistically significant difference. Therefore Using CT kernel of low variation of SD occur less variation of SUV.

  • PDF

A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique (다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점)

  • Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Kwon, Kyung-Tae;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

Study on Developing Assessment Guideline for Safety and Performance of Electric Cupping Apparatus (전동식 부항기에 대한 안전성 및 성능평가 가이드라인 개발연구)

  • Yi, Seung-Ho;Kim, Eun-Jung;Shin, Kyung-Hoon;Nam, Dong-Woo;Kang, Jung-Won;Lee, Seung-Deok;Lee, Hye-Jung;Lee, Jae-Dong;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.26 no.6
    • /
    • pp.101-110
    • /
    • 2009
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric cupping apparatus(Class 2 medical device). Methods : We drafted the guideline for safety and performance assessment of electric cupping apparatus by referring the existing standards and guideline, based on online questionnaire for Korean medical doctors and measurement data from commercially available products. Physical dimension of cups and inner vacuum pressure were acquired for the measurement in order to achieve the purposes. Results : This guideline only can be applied to electric cupping apparatus for enhancing blood circulation by employing negative pressure generated by electricity. Seven items of appearance and label, operation test of pump, variation test of input electricity, vacuum level test, vacuum sustain test, cup-size dependent test, noise level test are suggested for evaluation subjects and methods required for electric cupping devices. Requirements for the design and development of electric cupping devices are suggested: vacuum level indicator, vacuum generation rate, pressure control, valve detachment stability, cup comparability, safety measure, surge protection, user friendliness, instruction for use (IFU). Conclusions : We proposed a guideline for safety and performance assessment of electric cupping apparatus to improve the quality of relating products and aid the commercialization of them, by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

  • PDF

Performance Evaluation of a Novel Chaos Transceiver for the High Level Modulation (고레벨 변조를 위한 새로운 카오스 송수신기의 성능 평가)

  • Lee, Jun-Hyun;Ryu, Heung-Gyoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • Security of chaos communication system that has characteristic of sensitive initial conditions is superior to digital communication systems, but BER(Bit Error Rate) performance is evaluatied badly. So, studies in order to improve the BER performance is important. existing studies, BER performance of proposed chaos transceiver is possible to improve than the CDSK(Correlation Delay Shift Keying) system because it has characteristic that has very few addition elements like noise signal except for the desired signal. Chaos communication system has many symbols because it spreads according to characteristic of chaos map. Therefore, study that can have the good data rate in chaos communication system is required. Information bits of existing chaos modulation system are modulated as -1 and 1 on the basis of BPSK system. However, instead of BPSK system, if chaos communication system is applied high level modulation systems such as QPSK system and 16QAM system, it is possible to have good data rate because more data are transmitted at a time. In the paper, when QPSK system and 16QAM system are applied to proposed chaos transceiver in existing study, we evaluate the SER(Symbol Error Rate) performance and compare the each performance. Also, when QPSK system and 16QAM system are applied to proposed chaos transceiver, we evaluate the anti-jamming performance of proposed system.