• Title/Summary/Keyword: Noise level evaluation

Search Result 439, Processing Time 0.029 seconds

Review on Performance Requirements, Design and Implementation of RF Transceiver for Mobile Communications

  • Lee, Il-Kyoo;Ryu, Seong-Ryeol;Oh, Seung-Hyeub;Hong, Heon-Jin
    • Information and Communications Magazine
    • /
    • v.24 no.3
    • /
    • pp.76-86
    • /
    • 2007
  • This paper describes the RF performance issues of UE RF Transceiver for W-CDMA system based on 3GPP specifications. the parameters of transmitter and receiver are derived from the viewpoint of RF performance. In order for UE to achieve high performance, the transceiver performance requirements such as ACIR, EVM, Peak Code Domain Error, spectrum emission mask, frequency error stability and TX power control dynamic range for transmitter and reference sensitivity level, blocking characteristics, noise figure, ACS, linearity, AGC dynamic range for receiver are considered. On the basis of the required parameters, the UE RF transceiver is designed and then implemented. The evaluation of RF performance is accomplished through practical test scenarios.

Radiated Emission / Susceptibility Tests for the KSLV-I 2nd Stage Engineering Model (KSLV-I 2단부 엔지니어링 모델 복사성 방사/감응 시험)

  • Ji, Ki-Man;Lee, Soo-Jin;Chung, Eui-Seung
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.173-181
    • /
    • 2007
  • Radiated emission / susceptibility performance of the KSLV-I 2nd stage which are controlled from the unit level to the system level should be examined and managed all over the frequency ranges in order to ensure the normal operation of the SC, the 1st stage of the KSLV-I, ground support equipments which are installed at the space center, and other wireless communication networks. Not only unintentional electric field emissions from the KSLV-I system and its subsystems should be restricted to the levels less than the limits specified in the EMC requirements, but also proper test and evaluation method should be established, respectively. In this paper, radiated emission/susceptibility test limits, method, and test results of the KSLV-I 2nd stage engineering model are presented.

  • PDF

Vibration simulation of a multi-story high-speed railway station

  • Gao, Mangmang;Xiong, Jianzhen;Xu, Zhaojun
    • Interaction and multiscale mechanics
    • /
    • v.3 no.4
    • /
    • pp.365-372
    • /
    • 2010
  • Station is an important building in high-speed railway, and its vibration and noise may significantly affect the comfort of waiting passengers. A coupling vibration model for train-structure system is established to analyze and evaluate the vibration level of a typical waiting hall under dynamic train load. The motion of a four-axle vehicle with two suspension system is modeled in multi-body dynamics with linear springs and dampers employed. The station is modeled as a whole finite element structure which is 113 m in longitudinal and 163.5 m in lateral, and the stiffness of the station foundation is considered. According to the assumptions that both wheel and rail are rigid bodies and keep contact to each other in vertical direction, and the wheel/rail interaction and displacement coordination in horizontal direction is defined by the simplified Kalker creep theory, the vehicle spatial vibration model has 27 degrees-of-freedom. An overall analysis procedure is made of the train moving through the station, by which the dynamic responses of the train and the station are calculated. According to the comparison between analysis and test results, the actual connection status between different parts of the station is estimated and the vibration level of the waiting hall is evaluated.

Measurement and evaluation of speech privacy in university office rooms (대학 내 사무실의 스피치 프라이버시 측정 및 평가)

  • Lim, Jae-Seop;Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.396-405
    • /
    • 2019
  • The speech privacy of closed office rooms located in a university campus was measured and assessed in terms of SPC (Speech Privacy Class) values. The measurements of two quantities, the LD (Level Difference) between a source and a receiving room, and the background noise level ($L_b$) at the receiving room were carried out in 5 rooms located in 3 different buildings in the university campus. Each of the 5 rooms was adjacent to both offices and corridors through walls. The TL (Transmission Loss) between the source and the receiver room was also measured to compare the difference of two standard methods, ASTM E2836-10 and KS F 2809. The present results show that the speech privacy of the 5 office rooms is not met the requirement for a minimum SPC values of 70. A minimum LD value of 41 dB between the source and the receiver room should be achieved for having a SPC value of 70 when the mean measured value of $L_b$ at the receiving room is 29.2 dB. That is, the TL(avg) value averaged over the octave bands from 160 Hz to 5000 Hz between the source and the receiver room should be or greater than 40 dB. The most important architectural factor influencing the LD value is the presence of openings, such as doors, and windows, on the adjacent walls between the source and receiving room. Therefore, if the opening of the adjacent wall is replaced by an opening with high sound insulation, the appropriate SPC value of the research and office rooms can be achieved.

Environmental Pollution in Korea and Its Control (우리나라의 환경오염 현황과 그 대책)

  • 윤명조
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.5-6
    • /
    • 1972
  • Noise and air pollution, which accompany the development of industry and the increase of population, contribute to the deterioration of urban environment. The air pollution level of Seoul has gradually increased and the city residents are suffering from a high pollution of noise. If no measures were taken against pollution, the amount of emission of pollutant into air would be 36.7 thousand tons per year per square kilometer in 1975, three times more than that of 1970, and it would be the same level as that of United States in 1968. The main sources of air pollution in Seoul are the exhaust has from vehicles and the combustion of bunker-C oil for heating purpose. Thus, it is urgent that an exhaust gas cleaner should be instaled to every car and the fuel substituted by less sulfur-contained-oil to prevent the pollution. Transportation noise (vehicular noise and train noise) is the main component of urban noise problem. The average noise level in downtown area is about 75㏈ with maximum of 85㏈ and the vehicular homing was checked 100㏈ up and down. Therefore, the reduction of the number of bus-stop the strict regulation of homing in downtown area and a better maintenance of car should be an effective measures against noise pollution in urban areas. Within the distance of 200 metres from railroad, the train noise exceeds the limit specified by the pollution control law in Korea. Especially, the level of noise and steam-whistle of train as measured by the ISO evaluation can adversely affect the community activities of residents. To prevent environmental destruction, many developed countries have taken more positive action against worsening pollution and such an action is now urgently required in this country.

  • PDF

Evaluation on Hearing Conservation Program in the Noisy Industries (소음발생 산업장에서의 청력보존프로그램 평가)

  • Kwak, M.S.;Lee, J.T.;Kim, J.H.;Urm, S.H.;Kim, D.H.;Shon, B.C.;Lee, C.H.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.815-829
    • /
    • 1997
  • This study was performed to assist the employer to establish the effective program for hearing conservation of noisy industry. The study subjects were health care managers of an industry and the study industries were devided into two groups(Group I, 37 industries; have the workers diagnosed as noise-induced hearing loss, Group II, 41 industries; not have the workers diagnosed as noise-induced hearing loss) and the question method carried out through the face to face interview. The contents of questionnaire for OSHA's hearing conservation program(HCP) consisted of seven components: 5 questions of monitoring of employee noise exposures(component 1), 6 questions of the institution of engineering, work practice, and administrative controls for excessive noise(component 2), 8 questions of the provision of each overexposed employee with an individually fitted hearing protector with an adequate noise reduction rating(component 3), 14 questions of employee training and education regarding noise hazards and protection measures(component 4), 9 questions of baseline and annual audiometry(component 5), 3 questions of procedures for preventing further occupational hearning loss by an employee whenever such an event has been identified(component 6), and 1 question of recording keeping(component 7), thus total numbers of questions was 46. The numbers of statistially significant difference(p<0.05) between two groups were 2(25.0%) among 8 questions of component 3, 10(71.4%) among 14 questions of component 4, 3(33.3%) among 8 questions of component 5, 2(6.7%) among 3 questions of component 6, and 17(37.0%) among total 46 questions of questionnaire. Above results showed that the level of HCP acceptance in group I was lower than in group II. Thus employer's understanding about HCP should be precede for the effective hearing conservation program of employee and the adequate hearing protector, training and education, baseline and annual audiometry, and procedures for preventing further occupational hearning loss for hearing conservation would be more emphasized.

  • PDF

The Study of noise and vibration on application of the method breaking & excavating rock(Super wedge) (암파쇄굴착공법(Super wedge) 적용에 따른 소음.진동에 대한 고찰)

  • Won, Yeon-Ho;Kang, Choo-Won;Ryu, Chang-Ha
    • Proceedings of the KSEE Conference
    • /
    • 2006.10a
    • /
    • pp.167-184
    • /
    • 2006
  • There is cattle shed and house structure of a country village in the vicinity of the construction site. that is why the environmental effect evaluation on blasting had been done in advance to prevent any harm to those from the work. As the result, it is impossible to apply to the blasting method, and the Super wedge method, a kind of a rock-splitting method which there is no secondary breaking by a breaker of the methods breaking &excavating rock according to the classification of the blasting method by the ministry of construction & transpotation, applied to decrease noise and vibration, and to the work classification, the extent of noise and vibration measured with the instrument only for noise(SC-310c) and with the instrument only for vibration(BLASTMATE) respectively. A drilling, splitting, collecting, loading works at the closest point(about 10m) is barely possible on the consideration of vibration to the result of measurement, but carefulness needs on moving of equipment. On the case of noise, even drilling, collecting, loading work except splitting at the comparatively close point(about 20m) is difficult. So, the method breaking &excavating rock according to the classification of the blasting method by the ministry of construction & transpotation has to apply in consideration of noise level in accordance with the work processing.

  • PDF

Performance Evaluation of a Driving Power Transmission System for 50 kW Narrow Tractors

  • Hong, Soon-Jung;Ha, Jong-Kyou;Kim, Yong-Joo;Kabir, Md. Shaha Nur;Seo, Young Woo;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • v.43 no.1
    • /
    • pp.1-13
    • /
    • 2018
  • Purpose: The development of compact tractors that can be used in dry fields, greenhouses, and orchards for pest control, weeding, transportation, and harvesting is necessary. The development and performance evaluation of power transmission units are very important when it comes to tractor development. This study evaluates the performance of a driving power transmission unit of a 50 kW multi-purpose narrow tractor. Methods: The performance of the transmission and forward-reverse clutch, which are the main components of the driving power transmission unit of multi-purpose narrow tractors, was evaluated herein. The transmission performance was evaluated in terms of power transmission efficiency, noise, and axle load, while the forward-reverse clutch performance was evaluated in terms of durability. The transmission's power transmission efficiency accounts for the measurement of transmission losses, which occur in the transmission's gear, bearing, and oil seal. The motor's power was input in the transmission's input shaft. The rotational speed and torque were measured in the final output shaft. The noise was measured at each speed level after installing a microphone on the left, right, and upper sides. The axle load test was performed through a continuous equilibrium load test, in which a constant load was continuously applied. The forward-reverse clutch performance was calculated using the engine torque to axle torque ratio with the assembled engine and transmission. Results: The loss of power in the transmission efficiency test of the driving power unit was 6.0-9.7 kW based on all gear steps. This loss of horsepower was equal to 11-18% of the input power (52 kW). The transmission efficiency of the driving power unit was 81.5-89.0%. The noise of the driving power unit was 50-57 dB at 800 rpm, 70-77 dB at 1600 rpm, and 76-83 dB at 2400 rpm. The axle load test verified that the input torque and axle revolutions were constant. The results of the forward-reverse clutch performance test revealed that hydraulic pressure and torque changes were stably maintained when moving forward or backward, and its operation met the hydraulic design standards. Conclusions: When comprehensively examined, these research results were similar to the main driving power transmission systems from USA and Japan in terms of performance. Based on these results, tractor prototypes are expected to be created and supplied to farmhouses after going through sufficient in-situ adaptability tests.

Magnetic Resonance Imaging uses 3D Printed Material of Headset (Noise Reduction Effect) (자기공명영상 검사 시 3D 프린팅 재료를 이용한 헤드셋 연구 (소음저감 효과))

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.335-341
    • /
    • 2018
  • With the improvement of medical state, patients' expectations for the most advanced medical equipment are increasing. Particularly, Magnetic Resonance Image (MRI) is used as one of the core image diagnosis methods in all clinical area. However, it has been reported that many of patients who go through the examination suffer from anxiety to the severe noise level during the examination. In this study, both the noise reduction evaluation of headsets with sound-blocking materials added to existing sound-absorbing materials and the existence of sound blocking materials as artifacts on the examination image are tested. An MRI test noise is recorded as a speaker by cross-ordination the sound material (sponge) and the sound material (acrylic plate, copper plate, and 3D copper plate) inside the headset made from 3D pring. A quantitative assessment of headsets showed that the average headset value was 81.8 dB. The average dB value of the most soundproof material combination(Copper, acrylic plate, sponge, sponge) headsets on headsets with added charactering material was measured at 70.4 dB, and MRI showed that the copper was diamagnetic substance and excluded. The second most soundproof headset(Sponge, acrylic plate, 3D copper plate, sponge) was measured at 70.6 dB and MRI showed no artifacts. The same simulation of the material printed with a 3D copper PLA containing approximately 40 % copper powder resulted in no artifacts, therefore, the material output as a 3D printing was better suited for use. For MRI related research, the mutual development of 3D printing is highly anticipated.

A Comparative Analysis of the Level of Occupational Health : Before and After the Subsidiary Program on Health Care Management of Small Scale Industries (영세사업장 보건관리 지원사업 실시 전후의 산업보건수준 비교 분석)

  • Jung, Hye Sun
    • Korean Journal of Occupational Health Nursing
    • /
    • v.4
    • /
    • pp.58-83
    • /
    • 1995
  • The small scale industries which have less than 30 employees occupy 86.5% of total number of industries in Korea. And though they have higher accident rate and lower environmental condition than big industries, it has been not mandatory to appointing health care manager at factory. So, from 1993, government subsidizes to the health care management of small industries. The purpose of this study is to identify the real feature of health care status in small industries, and to evaluate the level of health care management, before and after the subsidiary program. 65 small plating industries which have been managed by the same health care management support institution in 1993 were selected for study. Of the 65 industries, 3 which have not taken both environmental evaluation and health screening in 1994, and 9 which have closed were excluded from study sample. And the remaining 53 were analyzed by using the results of environmental evaluation and health screening, reported to the Ministry of Labor, before and after the subsidiary program, the analysis was done by the comparison of the two year paired data of the same industry. Over-permissible-limit rate, health screening implementation rate, above grade C rate were calculated and compared. The status of health care management ; 1. Of the sample industries, 96.9% provide protective equipment and 80.0% set up ventilating system. Protective gloves (89.2%) and protective clothing (80.0%) are widely provided, but ear plugs (4.6%) are rarely provided. 21.5% of the protective equipment are well put on, and 40.4% of the ventilating systems function well. 2. In 1993, 35 industries, 53.8% of the sample, checked working environment twice. Over-permissible-limit rates of heavy metal (12.2%), suspended particle (11.1%), noise (5.5%) were high. To put on protective equipment and to set up local ventilating system were pointed out by the examiners. 3. General health screening was done at 63.1% of the sample industries and 35.3% of total workers were examined. Specific health screening was done at 93.8% of the sample industries and 75.4% of workers were examined. 15.5% of workers was provided to be above grade C and to have digestive system disease (43.3%), circulatory disease (18.9%), and hematopoietic disease (14.2%), etc. 4. In 1993, the subsidiary program of health care management was provided in forms of health education, health counseling, and rounding check of working field. And 61.5%, 83.0%, 55.4% of sample industries respectively received it. The average visit per industry was 1.8. Comparisons of the level of occupational health before and after the subsidiary program ; 1. Over-permissible-limit rates of hazardous factors of 1993 and that of 1994 were compared. The rates of suspended particle, noise, organic solvent of 1994 (37.5%, 13.4%, 24.2% respectively) were higher than that of 1993 (25.0%, 6.0%, 6.3% respectively). In the case of acid, there was no difference between the rate of 1993 and that of 1994. Only the rate of heavy metal decreased from 12.9% in 1993 to 3.0% in 1994. 2. General health screening was done at 38.7% of the sample industries in 1993 and at 44.6% in 1994. But the implementation rate of specific health screening decreased from 72.4% in 1993 to 64.6% in 1994. 3. The implementation rate of specific health screening was analyzed by some health factors. The rate of suspended particle increased from 61.8% in 1993 to 91.2% in 1994. But the rates of the others-noise, organic solvent, heavy metal, specific chemical substances-decreased. 4. Above grade C rate in health screening increased from 27.8% in 1993 to 35.5% in 1994. But that of endocrine disorders and pulmonary disease decreased.

  • PDF