• 제목/요약/키워드: Noise in ECG

검색결과 165건 처리시간 0.024초

전원잡음과 기저선변동을 고려한 이동형 ECG 센서모듈 및 모니터링 시스템 구현 (Portable ECG Sensor Module and Monitoring System Implementation Considering Reduction of Powerline Noise and Baseline Wander)

  • 오도창;최동혁;이홍우
    • 제어로봇시스템학회논문지
    • /
    • 제12권10호
    • /
    • pp.1022-1028
    • /
    • 2006
  • A portable ECG sensor module and monitoring system which has the powerline noise reduction and the baseline wander removal is proposed. A small-szie ECG sensor H/W module with the 8-bits microprocessor is implemented. The ECG waveform can be inspected anytime with PDA in real time, and transmitted to the PC through wireless LAN. Portable ECG system can offer the environment that give the lasting medical service to the elderly and the long-time hospitalized patients at the wanted place, and the system can be attached to the chair, wheel chair, treadmill, elderly walker and used to monitor the health condition of man

심전도 신호의 잡음 제거를 위한 적응 필터 (Adaptive Filter for Noise Cancellation of ECG's)

  • 이재준;송철규;이제석;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.186-189
    • /
    • 1992
  • Adaptive fliter for noise cancellation of ECG is proposed. An adaptive noise canceller using the least mean squares algorithm is used to reduce unwanted noise. The adaptive noise canceller minimizes the mean-square error between a primary input, which is the noisy ECG, and a reference input, which is either noise that is correlated in some way with the noise in the primary input or a signal that is correlated only with ECG in the primary input.

  • PDF

간접접촉 심전도 측정에서의 간접접촉 오른발 구동 접지 성능에 대한 연구 (A Study on Performance of Indirect-contact Driven-right-leg Ground in Indirect-contact ECG Measurement)

  • 임용규;김고근;박광석
    • 융합신호처리학회논문지
    • /
    • 제9권4호
    • /
    • pp.280-287
    • /
    • 2008
  • 간접접촉 심전도(IDC-ECG) 측정에 공통 모드 잡음을 줄이기 위해 오른발 구동(Driven-right-leg) 접지 방법을 적용하고 그 접지의 성능을 조사하였다. 최근에 소개된 간접접촉 심전도 측정 기술은 전극과 인체 피부간의 직접 접촉이 필요하지 않기 때문에, 최근에 필요성이 대두되고 있는 가정에서의 장기간 무구속 심전도 측정에 적합한 측정방법으로서 현재 다양한 응용이 연구되고 있다. 그렇지만 간접접촉 심전도는 전원선에 의한 60Hz 잡음이 기존 측정 방법보다 크게 발생하여, 응용 범위의 확대에 제약 조건이 되고 있다. 본 연구에서는, 기존의 심전도 측정 방법에 사용되는 오른발 구동 접지 방법을 간접접촉 심전도 측정 방법에도 적용하여, 공통모드 잡음 성분을 반전 증폭하여 의자 좌판(seat)에 깔린 전도성 직물을 통해 인체에 feedback하였다. 이로써 피부와 직접 접촉이 없는 간접 접촉 방식의 오른발 구동 접지를 구현하였으며, 이 접지가 안정적으로 동작되고, 오른발 구동 이득이 약 1000정도에서 40dB 수준의 전원 잡음 감소 됨을 확인할 수 있었다. 이 연구의 결과로 간접접촉 심전도의 주파수 대역을 기존의 30Hz이하에서 100Hz 수준까지 높일 수 있게 되었으며, 접지 임피던스를 높일 수 있게 되어 간접접촉 심전도의 응용 분야를 더욱 넓힐 수 있게 되었다.

  • PDF

무선센서네트워크 기반의 웨어러블 센서노드에서 3축 가속도 신호의 단채널 전송과 심전도 노이즈 제거에 대한 연구 (A Research for Removing ECG Noise and Transmitting 1-channel of 3-axis Accelerometer Signal in Wearable Sensor Node Based on WSN)

  • 이승철;정완영
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.137-144
    • /
    • 2011
  • Wireless sensor network(WSN) has the potential to greatly effect many aspects of u-healthcare. By outfitting the potential with WSN, wearable sensor node can collects real-time data on physiological status and transmits through base station to server PC. However, there is a significant gap between WSN and healthcare. WSN has the limited resource about computing capability and data transmission according to bio-sensor sampling rates and channels to apply healthcare system. If a wearable node transmits ECG and accelerometer data of 4 channel sampled at 100 Hz, these data may occur high loss packets for transmitting human activity and ECG to server PC. Therefore current wearable sensor nodes have to solve above mentioned problems to be suited for u-healthcare system. Most WSN based activity and ECG monitoring system have been implemented some algorithms which are applied for signal vector magnitude(SVM) algorithm and ECG noise algorithm in server PC. In this paper, A wearable sensor node using integrated ECG and 3-axial accelerometer based on wireless sensor network is designed and developed. It can form multi-hop network with relay nodes to extend network range in WSN. Our wearable nodes can transmit 1-channel activity data processed activity classification data vector using SVM algorithm to 3-channel accelerometer data. ECG signals are contaminated with high frequency noise such as power line interference and muscle artifact. Our wearable sensor nodes can remove high frequency noise to clear original ECG signal for healthcare monitoring.

디지털 FIR 필터와 Deep Learning을 이용한 ECG 신호 예측 및 경과시간 (Predicton and Elapsed time of ECG Signal Using Digital FIR Filter and Deep Learning)

  • 윤의중
    • 문화기술의 융합
    • /
    • 제9권4호
    • /
    • pp.563-568
    • /
    • 2023
  • 심전도(electrocardiogram, ECG)는 심박동의 속도와 규칙성, 심실의 크기와 위치, 심장 손상 여부를 측정하는 데 사용되며, 모든 심장질환의 원인을 찾아낼 수 있다. ECG-KIT를 이용하여 획득한 ECG 신호는 ECG 신호에 잡음을 포함하기 때문에 딥러닝에 적용하기 위해서는 ECG 신호에서 잡음을 제거해야만 한다. 본 논문에서는, ECG 신호에 포함된 잡음은 Digital FIR 해밍 창함수를 이용한 저역통과 필터를 사용하여 제거하였다. LSTM의 딥러닝 모델을 사용하여 3가지 활성화 함수인 sigmoid(), ReLU(), tanh() 에 대한 성능 평가를 비교했을 때, 오차가 가장 작은 활성화 함수는 tanh() 함수 임을 확인하였고, batch size가 작은 경우가 큰 경우보다 시간이 많이 소요되었다. 또한 GRU 모델의 성능 평가의 결과가 LSTM 모델보다 우수한 것을 확인하였다.

휴대용 심전도 측정장치를 위한 실시간 QRS-complex 검출 알고리즘 개발 (Development of Real-time QRS-complex Detection Algorithm for Portable ECG Measurement Device)

  • 안휘;심형진;박재순;임종태;정연호
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권4호
    • /
    • pp.280-289
    • /
    • 2022
  • In this paper, we present a QRS-complex detection algorithm to calculate an accurate heartbeat and clearly recognize irregular rhythm from ECG signals. The conventional Pan-Tompkins algorithm brings false QRS detection in the derivative when QRS and noise signals have similar instant variation. The proposed algorithm uses amplitude differences in 7 adjacent samples to detect QRS-complex which has the highest amplitude variation. The calculated amplitude is cubed to dominate QRS-complex and the moving average method is applied to diminish the noise signal's amplitude. Finally, a decision rule with a threshold value is applied to detect accurate QRS-complex. The calculated signals with Pan-Tompkins and proposed algorithms were compared by signal-to-noise ratio to evaluate the noise reduction degree. QRS-complex detection performance was confirmed by sensitivity and the positive predictive value(PPV). Normal ECG, muscle noise ECG, PVC, and atrial fibrillation signals were achieved which were measured from an ECG simulator. The signal-to-noise ratio difference between Pan-Tompkins and the proposed algorithm were 8.1, 8.5, 9.6, and 4.7, respectively. All ratio of the proposed algorithm is higher than the Pan-Tompkins values. It indicates that the proposed algorithm is more robust to noise than the Pan-Tompkins algorithm. The Pan-Tompkins algorithm and the proposed algorithm showed similar sensitivity and PPV at most waveforms. However, with a noisy atrial fibrillation signal, the PPV for QRS-complex has different values, 42% for the Pan-Tompkins algorithm and 100% for the proposed algorithm. It means that the proposed algorithm has superiority for QRS-complex detection in a noisy environment.

디지털 IIR Filter와 Deep Learning을 이용한 ECG 신호 예측을 위한 성능 평가 (Performance Evaluation for ECG Signal Prediction Using Digital IIR Filter and Deep Learning)

  • 윤의중
    • 문화기술의 융합
    • /
    • 제9권4호
    • /
    • pp.611-616
    • /
    • 2023
  • 심전도(electrocardiogram, ECG)는 심박동의 속도와 규칙성, 심실의 크기와 위치, 심장 손상 여부를 측정하는데 사용되며, 모든 심장질환의 원인을 찾아낼 수 있다. ECG-KIT를 이용하여 획득한 ECG 신호는 ECG 신호에 잡음을 포함하기 때문에 딥러닝에 적용하기 위해서는 ECG 신호에서 잡음을 제거해야만 한다. 본 논문에서는, ECG 신호에서 잡음은 Digital IIR Butterworth의 저역 통과 필터를 이용하여 제거하였다. LSTM의 딥러닝 모델을 사용하여 3가지 활성화 함수인 sigmoid(), ReLU(), tanh() 함수에 대한 성능 평가를 비교했을 때, 오차가 가장 작은 활성화 함수는 tanh() 함수 임을 확인하였으며, 또한 LSTM과 GRU 모델에 대한 성능 평가와 경과 시간을 비교한 결과 GRU 모델이 LSTM 모델보다 우수한 것을 확인하였다.

마이크로 컴퓨터를 이용한 실시간 QRS검출 앨고리즘 (A Real Time QRS Detection Algorithm Based-on microcomputer)

  • 김형훈;이경중;이성환;이명호
    • 대한전기학회논문지
    • /
    • 제35권4호
    • /
    • pp.127-135
    • /
    • 1986
  • This paper represents a real time algorithm which improves the some drawbacks in the past methods for detection of the QRS conplexes of ECG signals. In the conventional method we can't detect QRS complex and QRS duration more correctly in case of (1) the contaminated ECG with 60Hz noise, muscle noise. (2) the movement of the baseline for a QRS complex. (3) being abnormal QRS complex with prolonging QRS. Therefore, we have proposed a new algorithm which can detect accurate QRS complex detection in case of the contaminated ECG with 60Hz noise, muscle noise, and movement of baseline for QRS complex. Moreover, in case of prolonging QRS we accomplished to detect not only QRS complex but also a single pulse that has a width proportional to QRS duration. This algorithm which is proposed in our paper in our paper in programmed with 6502 assembly language for real time ECG signal processing.

  • PDF

실시간 자기동조 다중노치필터의 설계와 ECG 신호처리에의 적용 (Design of real-time self-turning multiple notched filter and it's application to ECG.)

  • 고한우;류승표;김원기;박상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1264-1267
    • /
    • 1987
  • In this study, a new implementation of an adaptive noise filter is proposed to eliminate timevarying 60Hz noise and its harmonics in ECG signal. The new technique was applied to the ECG and it was found in the experiment that it showed much better characteristics than conventional method.

  • PDF

문턱치에 따른 잡음제거 분석 (Analysis of De-noising by Thresholding)

  • 서정익;박은규
    • 한국정보컨버전스학회논문지
    • /
    • 제6권2호
    • /
    • pp.45-49
    • /
    • 2013
  • 다른 생체신호와 마찬가지로 심전도(ECG) 신호도 측정시 백색잡음이 발생한다. 백색잡음을 효과적으로 제거하여 심장 관련 진단의 정확도를 높이고자 하였다. 심전도 신호에 백색잡음을 발생시켜 샘플링 신호를 만들었다. 웨이블릿 변환과 문턱치를 이용하여 잡음을 제거하였다. 신호대잡음비(SNR)를 이용하여 제거된 잡음을 수치적으로 비교하였다. 신호대잡음비 비교한 결과 SURE 방법은 3, 5dB에서 5.9531, 4.9301로 가장 좋은 결과를 나타내었고, uninversal 방법은 7, 9dB에서 3.6590, 1.9698로 가장 좋은 결과를 나타내었다. 문턱치를 이용한 잡음 제거시 잡음을 효과적으로 제거할 수 있었다. 심전도를 이용한 심장질환 진단에 정확도를 높일 수 있을 것으로 기대된다.

  • PDF