• 제목/요약/키워드: Noise exposure level

검색결과 169건 처리시간 0.027초

고속도로 톨게이트 요금수납원 소음노출 수준 평가 (Noise level Assessment Exposed to Cashiers in the Highway Tollbooth)

  • 김갑배;정은교;김종규;박해동;강준혁
    • 한국소음진동공학회논문집
    • /
    • 제26권6_spc호
    • /
    • pp.729-735
    • /
    • 2016
  • According to the survey for working environment of the cashiers in highway tollbooths, workers replied that noise was the most harmful substances next to air pollutant in the tollbooth. Researches on the noise levels exposed to cashiers in the highway tollbooth scarcely have been performed. Therefore, the aim of this study was to acquire baseline data to prevent health impairments of the cashiers by evaluating noise level exposed to them. Noise dosimeters were used for monitoring workers' noise exposure level in the tollbooths at 8 different highway tollgates. The noise levels of tollbooths did not exceed noise exposure limit of the ministry of labor, 90 dB(A). The average TWA inside of the tollbooths was 55.4 dB(A) and the average TWA outside of tollbooths was 58.3 dB(A). The average TWA outside of tollbooths was slightly higher than that of inside of tollbooths. However, the significance probability(p-value) was 0.255 which means statistically not significant. The noise levels inside and outside of tollbooth were statistically significant to both mean traffic volume per day and traffic volume of passenger car.

수변 공사에 의한 충격음의 특성과 어류에 미치는 영향 (Characteristics of Impulsive Noise of Waterfront Construction Site and Its Effects on Fishes)

  • 배종우;박지현;윤종락
    • 한국소음진동공학회논문집
    • /
    • 제19권9호
    • /
    • pp.928-934
    • /
    • 2009
  • Underwater impulsive sound such as underwater blasting noise, piling noise and stone breaking hammer affects marine animal hearing response and organs. This study describes the characteristics of various impulsive noise from waterfront construction site and their effect on fish. Time constant, peak pressure, energy and SEL(sound exposure level) of four different underwater impulsive sounds are quantified. Auditory and non-auditory tissue damage ranges are derived by comparing their quantities to the exposure criteria for fish. Damage ranges of auditory tissue and non-auditory tissue of underwater boring blast of 150 kg of charge, are about 100 m and 300 m, respectively. Other three impulsive sounds also gives damage effects but less than that of underwater boring blast.

폐기물 소각시설 내부 소음에 관한 연구 (A Study on Noise in Waste Facilities)

  • 서병석;박노국;전용한
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.15-21
    • /
    • 2020
  • Industrial facilities need design to predict and reduce noise from design to prevent and reduce noise. The purpose of this study is to predict worker's environment and evaluate safety by analyzing noise inside underground blower room and air compressor room with fluid machinery in waste facility. This waste incineration facility was analyzed based on the ground floor, ground floor blower chamber, and air compressor chamber. The results of SPL(Sound Pressure Level) analysis at 1.5m away, which are frequently used to measure the SPL as a noise source, are as follows. SPL of basement level: 46.80[dB], SPL of ground layer: 48.57[dB]. As a result, it was expected that the noise level would be considerably lower than the 8 hours 50[dB] noise exposure per day.

화면 제공에 따른 주관적 반응의 차이 - 레저용 사격 소음을 중심으로 - (Difference of subjective response between with and without pictures - Focusing on the leisure shooting noise -)

  • 김득성;장서일;이연수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.727-734
    • /
    • 2008
  • This research presents a laboratory study about difference of subjective response between with and without pictures. A main source is impulsive sound caused by leisure shooting. The sources are sampled from outdoor noise and their levels range from 40 to 75 dB at the interval of 5dB. The noise unit is based on A-weighted sound exposure level (ASEL; $L_{AE}$). To make equal ASEL of outdoor noise, finite impulse response (FIR) filter is applied to the originally sampled source to include the effect of distance attenuation. The evaluation method of the jury test adopted a Semantic Difference(SD) Method. The intersection point which two lines crossed was used as reference point. The intersecting point of mean response rating between with and without pictures was approximately 44ASEL and that of %HA was about 60ASEL. In the result of the test, the negative effect of pictures was given at a lower levels than intersection point while the positive effect was given at a higher levels than that.

  • PDF

흉부방사선검사의 목표노출지수 설정을 위한 연구 (A Study to Establish Target Exposure Index for Chest Radiography)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.167-173
    • /
    • 2024
  • This study purpose to establish an appropriate target exposure index(EIT) using dose area product(DAP) and exposure index(EI) based on chest radiography. First, the system response experiment was conducted with radiation quality of RQA5 to compare the dosimetry and dose area product of equipment. Next, EI and DAP were acquired and analyzed while varying the dose in the diagnostic at 70kVp using a human body model phantom. The signal to noise ratio(SNR) of the obtained results was analyzed in the diagnostic with in the diagnostic reference level(DRL) application range. The DRL at percentage 25% had a dose of 0.17 mGy and EI was 83, and at percentage 75% the dose was 0.68 mGy and EI was 344. As the dose increased, the SNR in the subdiaphragm increased. To set the EIT, calibration must first be performed using a dosimeter and set within the DRL range to reflect the needs of the medical institution.

노이즈맵핑을 활용한 도로변 아파트단지의 세대외부소음 및 옥외지면소음 특성 분석 (Analysis of Building Facade Noise and Ground Noise in a Roadside Apartment Complex through Noise Mapping)

  • 신혜경;김명준
    • 한국소음진동공학회논문집
    • /
    • 제25권4호
    • /
    • pp.275-283
    • /
    • 2015
  • The aim of this study is to estimate the noise exposure of roadside apartment complex according to the characteristics of apartment complex. The facade noise level of residential buildings and the ground noise level inside apartment complexes were predicted and analyzed using noise mapping based on a computerized noise model. In addition, the correlation analysis between these noise levels and the characteristics of apartment complex such as traffic volume, building coverage, the number of adjacent roads, etc. was done in a total of 21 apartment complexes. The results showed that building facade noise level and ground noise level were positively correlated with traffic volume (correlation coefficient, r=0.616~0.623) and the number of adjacent roads (r=0.340~0.496). On the other hand, they were negatively correlated with building coverage (r=-0.413~-0.477) and complex area per the number of roads (r=-0.478~-0.615).

일 제조업체의 작업장 소음실태에 관한 연구 (A Study on Actual Condition of the Noise in a Factory)

  • 신수옥
    • 한국보건간호학회지
    • /
    • 제9권2호
    • /
    • pp.43-51
    • /
    • 1995
  • Many poeple has been engaged in industry is aware of the dangers from exposure to high intensity nose levels. The exposure to high intensity noise is encountered in a large number of situations. Laws governing the safety and health of employed people being to create a suitable working environment and eliminate unsafety practices and processes. Work areas should be designed and laid out so that they are satisfactory both from the environmental and safety points of view. In this connection safety also implies that noise is kept at a level which is not likety to cause hearing damage. This study was performed to measure the noise of press and assembly process in an automobile factory. and suggested the method of noise control. Consequently the effect ways of reducing level in working environment are as follows; 1. Changes to machines which would reduce noise generation. 2. Alteration of equipment to avoid impact in machinery and handing materials. 3. Enclosure of noisy machines or machine parts. 4. Mounting of attenuators on gas and air outlets as well as ventilation ducts. 5. Erection of sound absorbing screens. linings. and baffles in work areas. 6. The personal ear protectors can be chosen to protect the workers.

  • PDF

석탄화력발전소 작업자의 소음과 온열 스트레스에 대한 노출 평가 (Evaluation of Occupational Exposure to Noise and Heat stress in Coal-fired Power Plants)

  • 권지운;장광명;김성호;김세동;장미연;노지원;박승현
    • 한국산업보건학회지
    • /
    • 제33권4호
    • /
    • pp.464-470
    • /
    • 2023
  • Objectives: This study evaluated occupational exposures to noise and heat stress during routine non-outage works in three coal-fired power plants in the Republic of Korea. Methods: The data were collected during the summer of 2020. Full shift noise exposure of 52 workers were measured using noise dosimeters. Heat stress of 16 worksites were measured for 70 minutes using wet-bulb globe temperature monitors. Results: The noise dosimetry results revealed time-weighted averages that ranged from 47.5 to 88.9 dBA. 2 out of 52 noise measurements exceeded 85 dBA. Based on the arithmetic mean, the coal service group showed the highest level at 80.2 dBA by job tasks. Noise exposures exceeding 85 dBA were measured in the coal service and plant operator group. Heat stress index measurements ranged from 20.3℃ to 37.2℃. 1 out of 9 indices measured in coal facilities and 4 out of 7 indices measured in boiler house exceeded 1 hour TWA during moderate work. Heat stress indices measured from boiler houses were significantly higher than those measured from coal equipment. Conclusions: The results show that overexposure to noise and heat stress may be encountered during routine non-outage work activities in coal-fired power plants. Appropriate actions should be taken to reduce future health outcome from occupational exposure to noise and heat stress in the industry.

고화질 TV Set의 음향 파워 레벨 측정 및 평가 어휘 선정에 관한 실험적 연구 - LCD·PDP TV Set를 중심으로 - (A Study on the Power Level Measurement and Evaluating Vocabulary of H.D. TV Sets -Focused on LCD·PDP Tv Sets-)

  • 이태강;박현구;이주엽;이재천;신종근;김희진;김선우
    • 한국소음진동공학회논문집
    • /
    • 제15권9호
    • /
    • pp.1092-1099
    • /
    • 2005
  • This experimental study deals with the characteristics of LCD or PDP TV set noise, which are differ form those of CRT TV set. These characteristics are most important for establishing the effective method to reduce noise level, searching for the appropriate exposure level and evaluation method of LCD or PDP TV set noise. This study adopt two measurement method to specify the power level of LCD or PDP TV set noise in anechoic room(ISO 3741) and reverberation room(ISO 3745) . Comparing with each results of the two method, the reverberation room method is more simple in measuring and calculating the power level. And the subjective response test are carried out to select the pair of appropriate adjectives to present the characteristics of LCD or PDP TV set noise. The pair of 17 adjectives are selected from the 168 adjectives which are used in presenting the sound and noise form literature.

소음이 저작근에 미치는 효과 (Effects of Noise on the Masticatory Muscles)

  • 이상일;김기석
    • Journal of Oral Medicine and Pain
    • /
    • 제35권1호
    • /
    • pp.49-59
    • /
    • 2010
  • 본 연구는 단기간의 인공소음과 음악 청취에 대한 저작근의 반응을 조사하였다. 연구의 가설은 높은 소음은 작은 소음이나 음악에 비하여 저작근의 경도는 높이고 탄성도는 감소시킨다는 것이다. 15명의 지원자에게 60 dB 과 100 dB 의 소음과 음악을 각각 6분씩 들려주고 청취 전과, 청취 2분후, 4분후, 6분후에 tactile sensor system을 이용하여 교근과 측두근의 경도 및 탄성도를 조사하였다. 첫째날은 100 dB의 소음, 둘째날은 100 dB 의 음악, 셋째날은 60 dB 의 소음, 넷째날은 60 dB 의 음악을 청취한 후 조사하였다. 실험 결과, 60 dB, 100 dB 모두에서 소음과 음악 청취군 간에는 유의성 있는 차이가 대부분 없었으며, 60 dB, 100 dB군간의 비교에서 측두근에서는 유의한 차이가 없었으나 교근의 경우, 음악군에서는 탄성도에서, 소음군에서는 경도에서 유의한 차이를 보여주었다. 이는 소음의 종류에 관계없이 비록 음악이고 단기간의 청취일지라도 큰 소음인 경우에는 저작근의 수축을 야기할 수 있음을 의미한다.