• Title/Summary/Keyword: Noise Sensitivity

Search Result 1,066, Processing Time 0.025 seconds

Sensitivity Analysis of Fiber Optic Hydrophone for Hollow Cylindrical Mandrel (중공 원통형 광섬유 하이드로폰의 감도 해석)

  • 김정석;윤형규;설재수;남성현
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.565-569
    • /
    • 1999
  • Recently, fiber optic hydrophone is a subject which has attracted as a underwater acoustic sensor. In this study, Finite element modeling of fiber optic hydrophone for hollow cylindrical mandrel was performed and the acoustic sensitivity was calculated to estimate the performance of single element fiber optic hydrophone. And acoustic sensitivity was measured in acoustic water tank to verify the result of simulation. The result of FE analysis and experiment is -126 dB re rad/$\mu$ Pa and -128 dB re rad/$\mu$ Pa respectively.

  • PDF

Development of Real-time QRS-complex Detection Algorithm for Portable ECG Measurement Device (휴대용 심전도 측정장치를 위한 실시간 QRS-complex 검출 알고리즘 개발)

  • An, Hwi;Shim, Hyoung-Jin;Park, Jae-Soon;Lhm, Jong-Tae;Joung, Yeun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.280-289
    • /
    • 2022
  • In this paper, we present a QRS-complex detection algorithm to calculate an accurate heartbeat and clearly recognize irregular rhythm from ECG signals. The conventional Pan-Tompkins algorithm brings false QRS detection in the derivative when QRS and noise signals have similar instant variation. The proposed algorithm uses amplitude differences in 7 adjacent samples to detect QRS-complex which has the highest amplitude variation. The calculated amplitude is cubed to dominate QRS-complex and the moving average method is applied to diminish the noise signal's amplitude. Finally, a decision rule with a threshold value is applied to detect accurate QRS-complex. The calculated signals with Pan-Tompkins and proposed algorithms were compared by signal-to-noise ratio to evaluate the noise reduction degree. QRS-complex detection performance was confirmed by sensitivity and the positive predictive value(PPV). Normal ECG, muscle noise ECG, PVC, and atrial fibrillation signals were achieved which were measured from an ECG simulator. The signal-to-noise ratio difference between Pan-Tompkins and the proposed algorithm were 8.1, 8.5, 9.6, and 4.7, respectively. All ratio of the proposed algorithm is higher than the Pan-Tompkins values. It indicates that the proposed algorithm is more robust to noise than the Pan-Tompkins algorithm. The Pan-Tompkins algorithm and the proposed algorithm showed similar sensitivity and PPV at most waveforms. However, with a noisy atrial fibrillation signal, the PPV for QRS-complex has different values, 42% for the Pan-Tompkins algorithm and 100% for the proposed algorithm. It means that the proposed algorithm has superiority for QRS-complex detection in a noisy environment.

Study on Acoustic Resonance of Air-Conditioner Fan BLDC Motor (에어컨 팬 BLDC 전동기의 음향공진에 관한 연구)

  • Lee, Hong-Joo;Kim, Kwang-Suk;Kwon, Joong-Hak;Bang, Ki-Chang;Hwang, Sang-Moon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.212-217
    • /
    • 2008
  • Acoustic noises generated during motor operation in mechanical system are from electromagnetic, mechanical, aerodynamic, and electrical sources. For identification of mechanical noise origins, misalignment, unbalance, fan shape, resonance, and vibration modes have been extensively considered to describe noise behavior. An experiment-based approach as well as a mathematical approach needs to be adopted for a realistic study into noise and vibration of the motor, because motor noise characteristics differ from type to type due to various noise sources. In this paper, a brushless DC motor for air-conditioner fan is analyzed by finite element method to identify noise source, and the analysis results are verified by experiments, and sensitivity analysis is performed by design of experiments.

  • PDF

Floor Impact Noise Measurement and Evaluation Method Using Impact Ball (임팩트 볼을 활용한 바닥충격음 측정 및 평가)

  • Jeon, Jin-Yong;Jeong, Jeong-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.10 s.103
    • /
    • pp.1160-1168
    • /
    • 2005
  • Floor impact noise isolation performance of reinforced concrete floors was investigated through new measurement method using impact bail. Strong impact force in Bow frequency band below 63 Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight Impact noise but heavy-weight impact noise measurement and evaluation using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

The Study on Improvement of Audio Noise When 900MHz GSM Cellular Phone Built in HPC(Handheld PC) (GSM 모듈을 탑재한 HPC(Handheld PC)에서의 오디오 노이즈 개선에 관한 연구)

  • 박희봉;장복현;황금찬;박용서
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8A
    • /
    • pp.1169-1178
    • /
    • 1999
  • In this paper, the method to improve audio noise when GMS(Global System of Mobile Communication) is built in HPC(Handheld PC)is provided. The biggest problem with quality of audio is improved by connecting GSM module with wire to the widest erea near by HPC Power Ground to reduce impedance difference, and designing amplifier and earpiece, Result of measurement is satisfied with GSM Acoustic Standard. Standard of GSM Audio is declared in GSM 11.10 ETS 300 607-1. Measuring items corresponds to that standard and B&K Type 6712 is used for measurement. The list of measurement presented in this paper is Sending Sensitivity Frequency Response and SLR, Sending Loudness Rating( SLR level), Receiving Sensitivity Loudness Rating(RLR level), Talker Sidetone(STMR), Stability margin, and Echo Loss(ERL)

  • PDF

Application of Negative Ion Mass Spectrometry in Amino Acid Analysis (아미노산 분석에 음이온 질량분석법의 응용)

  • Pyo, Dongjin
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.77-82
    • /
    • 1993
  • Negative chemical ionization mass spectrometry(NCI-MS) can provide the enhancement in sensitivity in the analysis of amino acids. For molecules which are strongly electron-capturing, NCI-MS has been of amino to have detection limits in the femtomole to attomole($10^{18}$) range. Because of the selectivity of the ionization process, background noise is diminished, further enhancing signal to noise ratio. In this paper, we explored a dinitro-phenyl derivatives of amino acids by NCI-MS and compared it with eletron ionization method. The results demonstrated NCI-MS produces very clean spectra with a very little noise.

  • PDF

Analysis and Optimization of the Phase Noise of the Local Oscillator Signal for the CDMA Mobile Station (CDMA단말기의 LO 신호 위상 잡음에 의한 영향 분석 및 최적화)

  • 이상원;한명석;김학선;홍신남
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4C
    • /
    • pp.380-387
    • /
    • 2002
  • In this paper, the effect of the phase noise of a local oscillator on the ACPR of a transmitter and the reception sensitivity of a receiver to meet the TIA/EIA/IS-98-D for the CDMA mobile station was analyzed. And the optimum condition for performance of the local oscillator was suggested. It was found that the phase noise level of the local oscillator in a receiver and a transmitter should be below -138.3dBc/Hz and -120dBc/Hz, respectively, at 900kHz offset. It was confirmed that the reception sensitivity and ACPR efficiency were satisfactory when the signal of the local oscillator to the down-converter of a receiver with the phase noise level of less than -138.3dBc/Hz is supplied to the up-converter of the transmitter.

A study on the changes of the noise reception sensitivity in the optical system (광시스템의 잡음에 따른 수신감도 변화에 관한 연구)

  • Ra, Yoo-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.677-682
    • /
    • 2015
  • In this paper, we investigated the effect of light on the performance of the receiver system noise and external noise added from the ever-present influence in general optical system. And calculated the reception sensitivity of the receiver at the time of off-keying transmission - from the optical transmission system in consideration of the case that the photo detector has a quantum yield of less than one-one. Not less than 50 it was confirmed that it is possible to configure the low power system is calculated and compared with the case where less than 300 the receiver sensitivity of the optical system to maintain the standard error probability. However, even if these values were considered, and the preamplifier in the receiver, considering a case of using a low-output light source, so that a heavy burden in the value less than the actual system installation, using the light source having less than the output, as shown in Figure 3, the results that were obtained also may be used.

Analysis of Low Frequency Noise Variation in Temperature Sensor With Bi2Mg2/3Nb4/3O7 (Bi2Mg2/3Nb4/3O7을 사용한 온도센서의 저주파 잡음 특성)

  • Cho, Il Hwan;Seo, Dongsun
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.486-490
    • /
    • 2015
  • Sensitivity characteristics of temperature sensor with $Bi_2Mg_{2/3}Nb_{4/3}O_7$ (BMNO) layer were investigated with low frequency noise measurement. Temperature sensor with BMNO layer had high reliability and high sensitivity comparing with conventional MOS type temperature sensor. Annealing temperature variation effects with $600^{\circ}C$, $700^{\circ}C$ and $800^{\circ}C$ were measured and analyzed. Annealing temperature determines trap distribution and $700^{\circ}C$ annealing sample has different pattern comparing with other samples. Results of low frequency noise can offer the design guide of temperature sensor performance.