• Title/Summary/Keyword: Noise Protection Barrier

Search Result 7, Processing Time 0.023 seconds

Development of an Optical Height Formula for Noise Barrier Considering the Road Environment (도로환경에 따른 최적의 방음벽 높이 산정식 연구)

  • Lim, You-Jin;Moon, Hak-Ryong
    • International Journal of Highway Engineering
    • /
    • v.17 no.4
    • /
    • pp.63-68
    • /
    • 2015
  • PURPOSES : A study on the efforts to minimize the road traffic noise has been underway. An attempt has been made to measure the noise level using a noise map; however, the attempt is limited to certain areas only. In general, a noise barrier is employed to prevent road traffic noise; however, unplanned noise barriers developed without considering the surrounding environment, including excessively high walls, cause problems such as infringement on prospect right. Noise ceiling at daytime in Korea is 68 dB(A), which is relatively higher than in other countries. METHODS: The noise barrier used mainly for road noise reduction was analyzed to estimate the optimal height. Related variables such as road width, the height of the upper part, distance to the building, and angle (for instance, $30^{\circ}$). RESULTS : A formula to calculate the optical height of the noise barrier, considering the road environment (i.e., parameters such as road width and distance to building), was developed in this study in an attempt to mitigate the noise generated from the road. CONCLUSIONS : The formula to calculate the noise barrier is expected to lead to cost saving, accurate installation of barriers, and protection of the right of prospect.

Environmental Noise Prediction and Countermeasures for Packaged Power Station (육상용 디젤엔진 발전플랜트의 환경소음 영향 평가 및 저감 대책)

  • Song, Keun-Bok;Kim, Won-Hyun;Kim, Dong-Hae;Bae, Jong-Gug
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.6-11
    • /
    • 2007
  • Packaged power station (PPS) is a stationary diesel engine generator set and developed for the supply of electric power to small villages, islands and factories etc. Therefore, the PPS is closely installed to residence area and sometimes cause the environmental noise problems. In this paper, environmental noise analysis was performed for the power plant with 28 sets of PPS. The initial analysis results showed the some difference between the measurement and analysis because of the inaccurate noise source data. To improve the accuracy of analysis, main noise sources were inversely estimated using the in-situ measurement data in the vicinity of PPS and steam boiler. As the results of re-analysis, the good agreement was obtained and it was concluded that the noise levels exceed the specified noise limit in residence area. In order to reduce the noise, the several methods such as geometry alteration of inlet duct, application of hybrid-type silencer and noise protection barrier were suggested and verified with the confirmed analysis model.

  • PDF

A study on Traffic Noise control by the Environmental facilities around Roadway (도로연변 환경시설에 의한 교통소음 저감방안에 관한 연구)

  • Sul Jeung Min;Chung Yong
    • Journal of environmental and Sanitary engineering
    • /
    • v.3 no.2 s.5
    • /
    • pp.43-60
    • /
    • 1988
  • This study was carried out to determine traffic noise level and analyze noise reduction effects of various sound protection facilities in the area of Seoul, Inch'on, Songchoo and Seoul- Busan Expressway from March to Octover, 1987. The results were as follows; 1. As compared with the environmental standards and the traffic noise level in heavy noise areas, traffic noise levels observed were shown in higher than environmental standards. The noise levels in Seoul were determined at 12.8-18.2 dB(A) in daytime and 19.0-26.9 dB (A) in nighttime. And incase of inch'on, it were 6.7-9.6 dB(A) in daytime, 7.9-18.9 dB(A) in nighttime, respectively. 2. The environmental noise level observed in the backside of protection facilities, such as apartment, soundproof barrier and houses, which were constructed in paralled to the road was lower about 3-5 dB(A) than perpendicular to theroad. Noise recuction effect of upper stairs in apartment was higher than lower stairs. 3. The predicted noise level obtained from the equation $({\triangle}L\;=\; -10\;log\;(^{I'1}/Ii)\;was\;\pm\;1dB$ (A) and the correlation coefficient (r) was 0.923. 4. The noise reduction effect in backside of apartment was measured at on sites and predicted by total noise loss equation. The predicted noise level was 60.9 dB(A) and the measured level was 60.6 dB(A), respectively. 5. The narrow width landscape less than 10m width was almost no effect for the protection of traffic noise. According to the synthesis of the above results, the noise level of the road was exceeding mostly the environmental standard in the heavy traffic areas. The counterplan should be set as well. The insulation of noise protection facilities were effective by the location with near distance from the road edge. The reduction effect of double window in apartment was represented so much. The prediction model could be applied to estimate the noise levels in the roadside as well as the effectiveness for the noise protection facilities.

  • PDF

Study on Quality Criteria for Transparent Soundproof Panels(2) - Sound Insulation Characteristics and Evaluation of Weatherability (투명방음판의 품질기준 설정에 관한 연구(2) - 음향 특성 및 내후성 평가)

  • Chang, Taesun;Kim, Chulhwan;Hwang, Cheolho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.11
    • /
    • pp.1099-1105
    • /
    • 2012
  • Transparent noise barrier panels have the advantages of transmitting light to nearby residents and allowing drivers to orientate themselves by providing views of the surrounding area. To develop guidelines on quality criteria for transparent soundproof panels, their sound transmission loss and weatherability were experimentally investigated. In Korea, the sound transmission loss of noise barrier panels should be more than 25 dB at 500 Hz and 30 dB at 1000 Hz. The transmission loss tests of transparent panels were performed in accordance with KS F 2808. Typically, plastic materials suffer from color changes when exposed to ultraviolet(UV) light over extended periods. Therefore, weathering of plastics is one of the most important properties for outdoor applications. Protection against UV radiation and weathering is usually accomplished by using UV stabilizer additives or coatings. Transparent materials for soundproof panels were examined through accelerated weathering tests and their weathering resistances were evaluated from changes in yellowness index.

Railway Noise: Current Status and Reduction Schemes (철도변 환경소음: 현황과대책)

  • Kim, Jeung T.;Kim, Tae M.;Son, Jeung G.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.563-563
    • /
    • 2013
  • Railway noise has been a social issues nowadays in our community. This paper discusses the environmental noise problem along railway lines. We overview the noise level and noise exposed populations due to conventional and high speed train operation at first. Then we introduce variety of noise reduction schemes to protect the community based on an engineering approach. Some applicationcases to reduce the noise will be demonstrated. Finally, we propose the noise barrier tunnel as a tool of a generic solution to reduce the community noise along railway lines.

  • PDF

A Study on Noise Propagation Properties of Hi-Speed Train (고속으로 운행하는 고속철도의 소음 방사특성 연구)

  • Park, Tae-Ho;Han, Jong-Won;Ryu, Hun-Jae;Ko, Jun-Hee;Chang, Seo-Il
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2934-2940
    • /
    • 2011
  • The railway system in Korea is developing more and more rapidly. After development the next generation hi-speed train(HEMU-400X), Korea can compete against developed country. But, speed increasing will cause the greater rolling and aero dynamic noise. In this study shows that measurement noise of the KTX train by 300kn/h class, and KTX-Sancheon train by 350km/h class. The measurements are carried out on open area and noise protection barrier installed area. The microphones were placed at a distance of 3m from the center line of the track at a height of 0.5m above the upper surface of the rail and at a distance of 7.5m from the center line of the track at a height of each 0.6m above(Max 3.6m) the upper surface of the rail. One microphone was placed at a distance of 25m for check the environmental noise.

  • PDF

Noise Protection Roof: Partial Opening Effect for Noise Reduction (철도용 터널형 방음벽 개발연구: 설계 방향)

  • Kim, Tae-Min;Kim, Jeung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.6
    • /
    • pp.522-532
    • /
    • 2015
  • In the present study, a tunnel type soundproof wall with partial opening is proposed to reduce the environmental noise caused by railway vehicles traveling on bridges, which affects residents of high-rise apartment buildings; the study also attempts to minimize load due to wind and the weight of the wall. Applying the principles of computational fluid dynamics and structural mechanics, and the ray tracing method, a reduction in noise as well as of the overall weight of the soundproof walls is estimated. Analysis results show that the proposed soundproof wall with a partial opening weighs less, while reducing the wind loading by up to 30%. To prevent direct propagation of sound through openings in the wall, an acoustic louver, which is a type of silencer, could be considered for the opening. In order to achieve a similar noise effect with existing insulation material, the fluid flow and the insulation effect of the acoustic louver are analyzed. As the considered opening is in the range of 30~40% of the total length of the soundproof wall, the noise effect and wind load are reduced by 10dB and 25% respectively. Consequently, opening some part of tunnel type soundproof walls and installing louvers on the wall openings can have the effects of weight-reduction and reduced wind load. If a partial opening is applied with proper sound material application, a gain of an additional 5~10dB of noise reduction can be achieved.