• Title/Summary/Keyword: Noise Exposure Time

Search Result 140, Processing Time 0.023 seconds

An Assessment of Notice Exposure by Job and Dosimeter Parameters Setting in Automobile Press Factory (자동차 프레스 공정에 있어서 직무 및 누적소음기 설정치 차이에 따른 작업자의 소음노출 평가)

  • Jeong, Jee Yeon;Park, Seunghyun;Yi, GwangYong;Lee, Naroo;You, Ki Ho;Park, Junsun;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.190-197
    • /
    • 2001
  • Noise-induced hearing loss(NIHL) was the highest rate (43.5%~58.5% from 1996 to 1998) of positive findings through specific medical program in Korea. There were much more NIHL at workers of automobile manufacturing factories than other manufacturing factories. The specific aim of the present study was to determine the noise exposure of automobile press lines, according to their job titles, press line types(auto, semiauto), dosimeter parameters setting. There were a total 11 press lines sampled at a automobile manufacturing company. Among those press lines, 10 press lines were autolines with acoustic enclosure, one semiauto press line was no aucostic enclosure Noise exposure data were sampled for an work shift using noise dosimeter, which recorded both time-weighted average(TWA) and 1-min average. The mean OSHA TWA(Korea TWA with threshold 90) was $80.7dB(A){\pm}4.7dB(A)$ for leader, $82.8dB(A{\pm}4.5dB(A)$ for pallette man, $76.7dB(A){\pm}4.3dB(A)$ for press operators, $76.6dB(A){\pm}5.6dB(A)$ for crane operators, $77.1dB(A){\pm}2.8dB(A)$ for forklift drivers, whereas the mean NIOSH TWA was $88.9dB(A){\pm}1.7dB(A)$ for leader, $89.6dB(A){\pm}2.1dB(A)$ for pallette man, $86.7dB(A){\pm}1.8dB(A)$ for press operators, $88.5dB(A){\pm}2.0dB(A)$ for crane operators, $87.7dB(A){\pm}1.0dB(A)$ for forklift drivers. While L10 for NIOSH TWA samples was 84.8 dB(A) ~ 87.3 dB(A), L10 for OSHA TWA samples was 69.5 dB(A) ~ 77.4 dB(A). L10 means that the TWA for 90% of the samples exceeded L10. Among OSHA TWA(Korea TWA with threshold 90) samples for pallette man, 7.7 % exceeded 90 dB(A), the OSHA permissible exposure level, but OSHA TWA samples for the other job titles didn't. Among NIOSH TWA samples, the samples over 85 dB(A), the NIOSH recommended exposure limit, was 100% (leaders), 83.3 %(operators), 97.4%(palletteman), 100%(forklift drivers), 91.7 %(crane operator). The results of One-way random effects analysis of variance models shows that the difference between job titles was significant by OSHA TWA(p<0.05), but not significant by NIOSH TWA(p>0.05). NIOSH TWA samples were significantly higher than OSHA TWA samples(P<0.05). Regression analysis was used to obtain relationships between OSHA TWA samples and NIOSH TWA samples. In this case the coefficient of determination = 0.90, which shows the high degree association between two methods. Regression equation, NIOSH TWA = 0.552 * OSHA TWA + 42.13 dB(A), shows that if OSHA TWA is known, NIOSH TWA can be predicted by the equation. The mean TWA difference between threshold 80 dBA and 90 dBA was significant(p<0.01). While the TWA noise exposures were 7.7% above the Korea(OSHA) PEL, they were more than 83.3% over NIOSH REL. Automobile workers were exposed to noise level that could be potentially damaging to their hearing. It found that there is approximately 25% excess risk of hearing loss even if a worker is protected to the PEL in according to NIOSH study.

  • PDF

A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT (PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구)

  • Jang, Eui Sun;Kwak, In Suk;Park, Sun Myung;Choi, Choon Ki;Lee, Hyuk;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.67-71
    • /
    • 2013
  • Purpose: The Change of CT exposure condition have a effect on image quality and patient exposure dose. In this study, we evaluated effect CT image quality and SUV when CT parameters (Pitch, Rotation time) were changed. Materials and Methods: Discovery Ste (GE, USA) was used as a PET/CT scanner. Using GE QA Phantom and AAPM CT Performance Phantom for evaluate Noise of CT image. Images are acquired by using 24 combinations that four stages pitch (0.562, 0.938, 1.375, 1.75:1) and six stages X-ray tube rotation time (0.5s-1.0s). PET images are acquired using 1994 NEMA PET Phantom ($^{18}F-FDG$ 5.3 kBq/mL, 2.5 min/frame). For noise test, noise are evaluated by standard deviation of each image's CT numbers. And then we used expectation noise according to change of DLP (Dose Length Product) to experimental noise ratio for index of effectiveness. For spatial resolution test, we confirmed that it is possible to identify to 1.0 mm size of the holes at the AAPM CT Performance Phantom. Finally we evaluated each 24 image's SUV. Results: Noise efficiency were 1.00, 1.03, 1.01, 0.96 and 1.00, 1.04, 1.02, 0.97 when pitch changes at the QA Phantom and AAPM Phantom. In case of X-ray tube rotation time changes, 0.99, 1.02, 1.00, 1.00, 0.99, 0.99 and 1.01, 1.01, 0.99, 1.01, 1.01, 1.01 at the QA Phantom and AAPM Phantom. We could identify 1.0 mm size of the holes all 24 images. Also, there were no significant change of SUV and all image's average SUV were 1.1. Conclusion: 1.75:1 pitch is the most effective value at the CT image evaluation according to pitch change and It doesn't affect to the spatial resolution and SUV. However, the change of rotation time doesn't affect anything. So, we recommend to use the effective pitch like 1.75:1 and adequate X-ray tube rotation time according to patient size.

  • PDF

Evaluation of Tendency for Characteristics of MRI Brain T2 Weighted Images according to Changing NEX: MRiLab Simulation Study (자기공명영상장치의 뇌 T2 강조 영상에서 여기횟수 변화에 따른 영상 특성의 경향성 평가: MRiLab Simulation 연구)

  • Kim, Nam Young;Kim, Ju Hui;Lim, Jun;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • Recently, magnetic resonance imaging (MRI), which can acquire images with good contrast without exposure to radiation, has been widely used for diagnosis. However, noise that reduces the accuracy of diagnosis is essentially generated when acquiring the MR images, and by adjusting the parameters, the noise problem can be solved to obtain an image with excellent characteristics. Among the parameters, the number of excitation (NEX) can acquire images with excellent characteristics without additional degradation of image characteristics. In contrast, appropriate NEX setting is required since the scan time increases and motion artifacts may occur. Therefore, in this study, after fixing all MRI parameters through the MRiLab simulation program, we tried to evaluate the tendency of image characteristics according to changing NEX through quantitative evaluation of brain T2 weighted images acquired by adjusting only NEX. To evaluate the noise level and similarity of the acquired image, signal to noise ratio (SNR), contrast to noise ratio (CNR), root mean square error (RMSE) and peak signal to noise ratio (PSNR) were calculated. As a result, both noise level and similarity evaluation factors showed improved values as NEX increased, while the increasing width gradually decreased. In conclusion, we demonstrated that an appropriate NEX setting is important because an excessively large NEX does not affect image characteristics improvement and cause motion artifacts due to a long scan.

A Study on the Characteristics of Propagation and Effects of Vibration by Sand Drain Method in Construction Field (건설현장에서의 Sand Drain 시공에 의한 진동특성과 영향에 관한 연구)

  • Kwak, Kwang-Soo;Kim, Jae-Soo
    • KIEAE Journal
    • /
    • v.1 no.2
    • /
    • pp.13-19
    • /
    • 2001
  • Recently, With the increase of income level, many people desire to have agreeable and quiet surrounding. However, the extent and time of the exposure to construction noise and vibration is increasing, which is a factor that ruins the quietness of the surrounding and increasingly raises interests in its effects. In this point, this study attempts to survey the characteristics of construction vibration by SD(Sand drain) method in construction field. In addition, the result of study is presumed to be usable as the fundamental materials for an efficient counter-plan in case of the public resentment in relations to the construction vibration occurring henceforth.

  • PDF

Dynamic Characteristic Analysis of Galvano Meter Scanner for Angle Multiplexing of Holographic Data Storage (홀로그래픽 저장장치의 각다중화를 위한 갈바노미터의 동특성 해석 및 정밀 추종 제어)

  • Lee, Jae-Sung;Choi, Jin-Young;Yang, Hyun-Seok;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.338-341
    • /
    • 2005
  • This paper proposes a control system for a Galvano meter which can be used in angle multiplexing for a holographic data storage. Due to the small angle multiplexing selectivity and the exposure/delay time of a CCD camera, the system needs to be controlled to satisfy the performance specification. First, the mathematical model is derived by combining the electrical and mechanical dynamic equations. Then, the obtained model was tuned by the experiments. Finally, a PID controller using DSP was designed and was applied the holographic system. From this approach, we successfully meet the performance specification.

  • PDF

Improving Image Quality Method in Tandem-type Color Laser Printers (탠덤 방식 컬러 레이저 프린터의 이미지 향상 방법)

  • Sim, Dong-Guk;Kim, Sung-Dae;Woo, Sang-Bum;Jeong, Gi-Cheol;Kim, Heon-Joo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.138-140
    • /
    • 2014
  • The image quality of the color laser printer is highly related with the motion quality of actuators. However, the high precision system requires high production costs in general. The proposed design method in this paper improves image quality without increasing production costs. Using the synchronization method, time gap between exposure and transfer in organic photo conductive (OPC) drum and the period of driving gear revolution are synchronized. The proposed method is verified by computer simulations and experiment, and showed by printed images.

  • PDF

Development progress in the Maunakea Spectroscopic Explorer's Exposure Time Calculator (MSE-ETC)

  • Kim, Taeeun;Kim, Changgon;Ji, Tae-Geun;Ahn, Hojae;Yang, Mingyeong;Pak, Soojong;Hong, Sungwook E.;Sobeck, Jennifer;Szeto, Kei;Marshall, Jennifer;Surace, Christian
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.75.1-75.1
    • /
    • 2021
  • MSE (Maunakea Spectroscopic Explorer)는 11.25m 구경의 망원경과 최대 4,000 개의 천체를 한 번에 관측할 수 있는 분광기를 통해 다천체 분광학 연구를 이끌 차세대 관측기기이다. 경희대학교는 망원경에 장착되는 다천체 분광기의 성능 요구사항을 바탕으로 노출 시간 소프트웨어 ETC (Exposure Time Calculator)를 개발하고 있다. ETC는 대기에 의한 연속선 소광, 방출선과 흡수선, 망원경 및 광학 기기의 투과율, 검출기의 암전류와 읽기 잡음을 바탕으로 신호 대 잡음비 S/N (Signal to Noise)을 도출하여 천체를 분광 관측하기 위한 적절한 노출 시간을 계산한다. MSE-ETC는 저분산 LR (Low Resolution, R=3,000), 중분산 MR (Moderate Resolution, R =6,000) 및 고분산 HR (High Resolution, R=40,000)의 관측 모드로 가시광선과 근적외선 영역의 S/N과 파장, 그리고 S/N과 AB등급 간의 상관관계를 보여준다. 본 포스터에서는 개발 중인 MSE-ETC 프로그램의 구조와 작동 알고리즘 및 사용 예를 발표한다.

  • PDF

Exposure Assessment and Management of Ionizing Radiation (전리방사선 노출과 관리)

  • Chung, Eun-Kyo;Kim, Kab-Bae;Song, Se-Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.27-35
    • /
    • 2015
  • Objectives: To investigate safety and health management, conditions in factories or facilities handling radiation-generating devices and radioactive isotopes were reviewed in terms of regulations of radiation safety control in Korea. Radiation exposure levels generated at those facilities were directly measured and evaluated for establishing an effective safety and health management plan. Methods: Government organizations with laws and systems of radiation safety and health were investigated and compared. There are three laws governing radiation-related employment such as occupational safety and health acts, nuclear safety acts, and medical service acts. We inspected 12 workplaces as research objects:four workplaces that manufacture and assemble semiconductor devices, three non-destructive inspection workplaces that perform inspections on radiation penetration, and five workplaces in textile and tire manufacturing. Monitoring of radiation exposure was performed through two methods. Spatial and surface monitoring using real-time radiation instruments was performed on each site handling radiation generating devices and radioactive isotopes in order to identify radiation leakage. Results: According to the occupational safety and health act, there is no legal obligation to measure ionizing radiation and set dose limits. This can cause confusion in the application of the laws, because the scopes and contents are different from each other. Surface dose rates in radiation generating devices such as implanters, thickness gages and accelerators, which were registered according to nuclear safety acts, using surveymeters, and seven of 36 facilities(19.4%) exceeded the international standards for surface radiation dose of $10{\mu}Sv/hr$. Conclusions: The results showed that occupational health and safety acts require a separate provision for measuring and assessing the radiation exposure of workers performing radiation work. Like noise, ionizing radiation will also periodically be controlled by including it in the object factors of work-environment measurement.

VARIABLE STARS IN A FIELD OF THE OLD OPEN CLUSTER M67 PHOTOMETRIC PRECISION OF THE BOAO 1.8M TELESCOPE

  • KIM SEUNG-LEE;CHUN MOO-YOUNG;PARK BYEONG-GON;LEE SEE-WOO
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.1
    • /
    • pp.43-51
    • /
    • 1996
  • We present test results of time-series CCD photometry to investigate the photometric precision of the BOAO (Bohyunsan Optical Astronomy Observatory) 1.8m telescope. A well-known field of the old open cluster M67, which includes two pulsating blue stragglers and two W UMa type binaries, was monitored for 3.5 hours on February 22, 1996. We have collected 148 V frames and 3 B frames. Photometric noises which consist mainly of photon noise and scintillation noise, were lowered down to about 1.9 mmag for stars of $10.\;^m5$ in M67 with exposure time of 20 seconds. From the C-M diagram for M67, a number of observational properties were derived; E(B-V) = 0.03, (V-Mv)o = 9.6, Age = 4 Gyr. We obtained light curves for four known variable stars and confirmed their variational characteristics. The pulsating blue stragglers show a low amplitude (about 0.01 mag) of light variation.

  • PDF

A Study on the noise working environment and occupational hearing impairment in the manufactoring industries (제조업 산업장의 소음환경과 직업성 난청에 관한 조사연구)

  • Lee, Chae-Eon;Lee, Jong-Tae;Son, Hye-Suk;Mun, Deok-Hwan;Jo, Byeong-Man;Kim, Seong-Cheon;Bae, Gi-Taek;Kim, Yong-Wan
    • 월간산업보건
    • /
    • s.5
    • /
    • pp.4-15
    • /
    • 1988
  • In order to proffer the fundamental data for the better working environment and the effective establishment of hearing conservation program on workers exposed to industrial noise, author assessed noise levels on the 42 noisy processes among 84 manufactures of 9 industries and measured noise gearing loss by the type of industries on 3,104 workers at these noisy processes from March, 1986 to Februry, 1987. The results were summarized as follows: 1. The averge of A-weight sound level of 23 processes(54.8%) and the avergae of sound level at each octave band of 14 processes(33.3%) exceeded the permissible exposure limits in 8 hours per day. 2. The noise level was the highest in process of cocking of ship building(109.1dBA), and followed by plating of steel rolling(104.3dBA), rivet of manufacture of motor vehicles(102.5dBA), shot of ship building(98.5dBA), aciding(95.7BA) and steel tubing(95.0dBA) of steel rolling, weaving of textiles(95.0dBA). 3. The permissible exposure time for the average of sound level at each octave band was only 30 minutes in the process of cocking of ship building, plating of steel rolling and rivet of manufacture of motor vehicles. 4. As a result of audiometric examination in 3,104 workers, the rate of hearing loss over 50dB at 4,000Hz was 7.3%(227 workers) and the rate of hearing loss over 41dB at 60average method was 2.9%(89 workers). 5. The prevalence of occupational hearing loss in ship building and manufacture of motor vehicle was 5.2% and it was the highest among prevalence of these 9 industries. 6. As a result of this suvery, the noise control and gearing conservation program were required especially in the industry of ship building and manufacture of motor vehicle.

  • PDF