• Title/Summary/Keyword: Noise Exposure Time

검색결과 140건 처리시간 0.025초

석탄화력발전소 작업자의 소음과 온열 스트레스에 대한 노출 평가 (Evaluation of Occupational Exposure to Noise and Heat stress in Coal-fired Power Plants)

  • 권지운;장광명;김성호;김세동;장미연;노지원;박승현
    • 한국산업보건학회지
    • /
    • 제33권4호
    • /
    • pp.464-470
    • /
    • 2023
  • Objectives: This study evaluated occupational exposures to noise and heat stress during routine non-outage works in three coal-fired power plants in the Republic of Korea. Methods: The data were collected during the summer of 2020. Full shift noise exposure of 52 workers were measured using noise dosimeters. Heat stress of 16 worksites were measured for 70 minutes using wet-bulb globe temperature monitors. Results: The noise dosimetry results revealed time-weighted averages that ranged from 47.5 to 88.9 dBA. 2 out of 52 noise measurements exceeded 85 dBA. Based on the arithmetic mean, the coal service group showed the highest level at 80.2 dBA by job tasks. Noise exposures exceeding 85 dBA were measured in the coal service and plant operator group. Heat stress index measurements ranged from 20.3℃ to 37.2℃. 1 out of 9 indices measured in coal facilities and 4 out of 7 indices measured in boiler house exceeded 1 hour TWA during moderate work. Heat stress indices measured from boiler houses were significantly higher than those measured from coal equipment. Conclusions: The results show that overexposure to noise and heat stress may be encountered during routine non-outage work activities in coal-fired power plants. Appropriate actions should be taken to reduce future health outcome from occupational exposure to noise and heat stress in the industry.

소리의 종류와 크기에 따른 일과성 청력 역치 상승과 회복의 차이 (Differences in Temporary Threshold Shift and Recovery Patterns Depending on Sound Type and Pressure)

  • 이채관
    • 한국산업보건학회지
    • /
    • 제30권4호
    • /
    • pp.387-393
    • /
    • 2020
  • Objective: This study aimed to investigate the differences in temporary threshold shift (TTS) and recovery patterns according to different types of sound and volume. Methods: TTS and recovery patterns were assessed for eight students after 30-minute exposure to both 70.0 dB and 90.0 dB of factory noise (noise) as well as music. TTS was measured before exposure and two minutes post exposure, and recovery patterns were evaluated every 10 minutes for one hour. The subjects performed activities of daily life and sleeping times as usual but taking drugs or drinking alcohol were prohibited. The experiment was repeated three times with an interval of at least 16 hours. ANOVA and T-test were carried out using SPSS 19.0 for Windows. Results: The hearing threshold of all subjects before exposure was less than 30 dB at all frequencies. Mean TTSs of 70 dB noise and 90 dB noise exposure were 0.14 and 4.48 dB (p<0.001). Meanwhile, the difference in music was insignificant (-0.63 dB and 0.55 dB, p=0.063). A significance in the difference was also found between the mean TTS of music and noise exposure, more obviously at 90.0 dB (p<0.001) than at 70 dB (p=0.232). The TTS differences were found frequency-wise in terms of sound type. Mean TTS by frequency was higher at 4,000 and 6,000 Hz than at other frequencies, and higher in noise than music at the same sound pressure. The TTS difference in each frequency between both sound types was significant at 90 dB (p<0.001). Subjects mostly recovered from TTS in one hour after exposure, but not with 90 dB-noise exposure. Conclusion: TTS and recovery patterns were different depending on the sound type. When exposed to factory noise, TTS was greater and recovery time was longer compared to music at the same sound pressure. These results suggested that the difference in cognitive processes and psychological factors according to the type of sound causes a change in TTS and recovery.

CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용 (Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.941-946
    • /
    • 2019
  • 환자의 진단 및 치료를 결정할 때 전산화단층촬영 (computed tomography; CT)은 우수한 해부학 정보를 제공하기 때문에 진단에 큰 도움이 되어 있다. 그에 따른 사용빈도가 증가하고 있으며, 활용 및 응용범위도 확대되어가는 추세이다. 저관전압을 사용해서 CT 검사를 하면 노이즈가 증가한다. 기존의 여러 연구에서는 영상재구성법에 대한 노출조건을 조절하는 방법 등을 시도해서 최적의 화질을 찾는 방법을 찾고 있으나 근본적 문제해결은 되지 못한다. 입력 영상의 신호를 유지하고 노이즈만을 최대한 제거하기 위해서 이중 트리웨이블릿 알고리즘을 적용하였다. 실험결과 100kVp, 회전시간 0.5sec의 영상에서 complex oriented 2d 방을 사용 할 경우 노이즈는 8.53에서 4.51로 줄어들었다. 본 연구를 통해서 저관전압 두부 CT에서 발생하는 높은 수준의 노이즈를 최적의 노이즈제거 알고리즘으로 노이즈를 제거하고 환자선 량을 낮출 수 있었다. 본 연구결과를 임상에서 사용 시 저선량의 CT 사용이 가능하고 환자 피폭을 줄일 것으로 판단한다.

Photometric Defocus Observations of Transiting Extrasolar Planets

  • Hinse, Tobias C.;Han, Wonyong;Yoon, Joh-Na;Lee, Chung-Uk;Kim, Yong-Gi;Kim, Chun-Hwey
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권1호
    • /
    • pp.21-32
    • /
    • 2015
  • We have carried out photometric follow-up observations of bright transiting extrasolar planets using the CbNUOJ 0.6 m telescope. We have tested the possibility of obtaining high photometric precision by applying the telescope defocus technique, allowing the use of several hundred seconds in exposure time for a single measurement. We demonstrate that this technique is capable of obtaining a root-mean-square scatter of sub-millimagnitude order over several hours for a V~10 host star, typical for transiting planets detected from ground-based survey facilities. We compared our results with transit observations from a telescope operated in in-focus mode. High photometric precision was obtained due to the collection of a larger amount of photons, resulting in a higher signal compared to other random and systematic noise sources. Accurate telescope tracking is likely to further contribute to lowering systematic noise by exposing the same pixels on the CCD. Furthermore, a longer exposure time helps reduce the effect of scintillation noise which otherwise has a significant effect for small-aperture telescopes operated in in-focus mode. Finally we present the results of modelling four light-curves in which a root-mean-square scatter of 0.70 to 2.3 milli-magnitudes was achieved.

위상이동법과 시간평균법의 면내변위 측정 비교 (Comparison of In-Plane Measurement of Phase-Shifting with Time-Average Method)

  • 김경석;김동일;정현철;강기수;이찬우;양승필;장순석
    • 한국정밀공학회지
    • /
    • 제16권10호
    • /
    • pp.53-58
    • /
    • 1999
  • Even I the Electronic Speckle Pattern Interferometry(ESPI) method that measure the strain of object within wavelength of light is less visibility than Holographic Interferometry(HI) method, the merits of application, convenience and time-save have made the method practical in industry. However, the existing ESPI methods that are based on dual-exposure, real-time and time-average method have difficulties for accurate measurement, due to irregular intensity and shake of phase. Recently, in order to solve this problem, phase shifting method have been proposed. In this method, the path of reference light in interference is shifted to make improvement in distinction and precision. But this method includes too many noise, caused by the problem of relationship between object and phase. Therefore, a method to reduce noise muse be introduced. In this paper, least square fitting method is proposed. As results, the phase-map is influenced by precise phase shifting and current of notes and speckle pattern obtained by phase shifting method is improved on the existing method driven from time-average method.

  • PDF

ISO 2631-1을 이용한 국내 고속철도차량의 인체진동 노출량 평가 (Evaluation of Human Exposure to Vibration on Domestic High-speed Train using ISO 2631-1)

  • 김지만;박진한;안세진;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제25권4호
    • /
    • pp.266-274
    • /
    • 2015
  • Vibration exposure of domestic high speed trains(KTX and ITX-saemaeulho) to passenger traveling on the Gyung-Bu line was measured to evaluate health effect which is based on ISO 2631-1. The vibration exposure was compared with the frequency weighted root mean square(r.m.s.) and vibration dose value(VDV) of the two trains’ vibration. It is concluded that vibration exposure of the two train during round trip of Busan-Seoul in single day is evaluated to be safe for the passenger’s health according to the health guidance caution defined on ISO 2631-1. Futhermore KTX’s vibration exposure is found to be significantly lower than ITX-saemaeulho thanks to lower vibration magnitude as well as shorter trip time.

홀로그래픽 간섭계를 이용한 Hele-Shaw Convection Cell 내부 온도장 측정 (Temperature Field Measurements of Hele-Shaw Convection Cell Using a Holographic Interferometry)

  • 김석;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.530-535
    • /
    • 2001
  • Variations of temperature field in a Hele-Shaw convection cell (HSC) were measured using a holographic interferometry with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Especially, the period of oscillation at $Ra = 6.35{\times}10^6$ was 62 seconds. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noise, compared with the double-exposure method. The two holographic interferometer techniques employed complementary in this study were proved to be useful for analyzing the temperature field variations of unsteady thermal fluid flows.

  • PDF

홀로그래픽 간섭계를 이용한 Hele-Shaw Convection Cell 내부 온도장 측정 (Temperature Field Measurements of Hele-Shaw Convection Cell Using a Holographic Interferometry)

  • 김석;이상준
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1624-1631
    • /
    • 2001
  • Variations of temperature field in a Hele-Shaw convection cell (HSC) were measured using a holographic interferometry with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Especially, the period of oscillation at Ra = 6.35 $\times$ 10$^{6}$ was 62 seconds. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noise, compared with the double-exposure method. The two holographic interferometer techniques employed complementary in this study were proved to be useful fur analyzing the temperature field variations of unsteady thermal fluid flows.

VISUALIZATION OF THE INTERNAL WATER DISTRIBUTION AT PEMFC USING NEUTRON IMAGING TECHNOLOGY: FEASIBILITY TEST AT HANARO

  • Kim Tae-Joo;Jung Yong-Mi;Kim Moo-Hwan;Sim Cheul-Muu;Lee Seung-Wook;Jeon Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • 제38권5호
    • /
    • pp.449-454
    • /
    • 2006
  • Neutron imaging technique was used to investigate the water distribution and movement in Polymer Electrolyte Membrane Fuel Cell (PEMFC) at HANARO, KAERI. The Feasibility tests were performed in the first and second exposure rooms at the neutron radiography facility (NRF) at HANARO in order to check the ability of each exposure room, respectively. The feasibility test apparatus was composed of water and pressurized air before making up the actual test apparatus. Due to the low neutron intensity in the second exposure room, the exposure time was too long to investigate the transient phenomena of PEMFC. Although the exposure time was improved to 0.1 sec in the first exposure room, it was difficult to discriminate detail water movement at the channel due to the high noise level. Therefore, the experimental setup must be optimized according to the test conditions. Water discharge characteristics were investigated under different flow field geometries by using feasibility test apparatus and the neutron imaging technique. The water discharge characteristics of a 3-parallel serpentine are superior to those of a 1-parallel serpentine, but water at Membrane Electrode Assembly (MEA) was not removed, regardless of the flow field type.