• 제목/요약/키워드: Noise Environmental Standard

검색결과 140건 처리시간 0.029초

도로연변 환경시설에 의한 교통소음 저감방안에 관한 연구 (A study on Traffic Noise control by the Environmental facilities around Roadway)

  • 설증민;정용
    • 환경위생공학
    • /
    • 제3권2호
    • /
    • pp.43-60
    • /
    • 1988
  • This study was carried out to determine traffic noise level and analyze noise reduction effects of various sound protection facilities in the area of Seoul, Inch'on, Songchoo and Seoul- Busan Expressway from March to Octover, 1987. The results were as follows; 1. As compared with the environmental standards and the traffic noise level in heavy noise areas, traffic noise levels observed were shown in higher than environmental standards. The noise levels in Seoul were determined at 12.8-18.2 dB(A) in daytime and 19.0-26.9 dB (A) in nighttime. And incase of inch'on, it were 6.7-9.6 dB(A) in daytime, 7.9-18.9 dB(A) in nighttime, respectively. 2. The environmental noise level observed in the backside of protection facilities, such as apartment, soundproof barrier and houses, which were constructed in paralled to the road was lower about 3-5 dB(A) than perpendicular to theroad. Noise recuction effect of upper stairs in apartment was higher than lower stairs. 3. The predicted noise level obtained from the equation $({\triangle}L\;=\; -10\;log\;(^{I'1}/Ii)\;was\;\pm\;1dB$ (A) and the correlation coefficient (r) was 0.923. 4. The noise reduction effect in backside of apartment was measured at on sites and predicted by total noise loss equation. The predicted noise level was 60.9 dB(A) and the measured level was 60.6 dB(A), respectively. 5. The narrow width landscape less than 10m width was almost no effect for the protection of traffic noise. According to the synthesis of the above results, the noise level of the road was exceeding mostly the environmental standard in the heavy traffic areas. The counterplan should be set as well. The insulation of noise protection facilities were effective by the location with near distance from the road edge. The reduction effect of double window in apartment was represented so much. The prediction model could be applied to estimate the noise levels in the roadside as well as the effectiveness for the noise protection facilities.

  • PDF

소음 단원의 교수-학습 모형 개발 및 적용에 관한 현장 연구 (A Case Study on the Teaching Method of the "Noise" Unit)

  • 송호열
    • 한국환경교육학회지:환경교육
    • /
    • 제15권2호
    • /
    • pp.14-29
    • /
    • 2002
  • The environment of the world becomes deteriorated rapidly as the result of the development of technology, the increase of the standard of living, and the growth of population. These circumstances called for environmental education in Korea, creating an environment course in the middle and high school in 1995. Despite the increasing importance of environmental education, however, the situation has not developed in its favor because of the current system of the university entrance examination. The school has failed to develop the curriculum of environmental education in the secondary education. This paper solves this problem internally in terms of the improvement of the contents, organization, teaching method (role-playing game), and teaching materials of environmental education, with a case study of the “noise” unit in 10th grade. This case study expects to change the attitude toward noise, increase the interest and knowledge in environment, and lead to responsible environmental behavior.

  • PDF

대학주변 원룸형 다가구주택의 소음측정평가 (Evaluation on Noise Level of One-Room Type Multi-Family Housing Around Campus)

  • 최윤정
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.95-100
    • /
    • 2003
  • The purpose of this study is to evaluate the noise environment of one-room type multi-family housing around the campus. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the 26th${\sim}$28th of November 2002. The results are as follows. 1) Outdoor noise levels of 6 subject buildings were distributed 52.8${\sim}$65.3dB(A) and were inappropriate to the standard for environmental noise, 55dB(A). 2) Indoor noise level of 6 subject house units were measured 27.5${\sim}$63.5dB(A). These values were higher than the indoor noise standard (40dB(A)) except subject house D(average 37.6dB(A)). 3) It was found that the differences of indoor noise levels between subject house units were caused by resident's living factor, characteristics of window, and existence of balcony.

  • PDF

건설기계류 소음·진동 특성 (Characteristics of Construction Machinery Noise and Vibration)

  • 강대준;이우석;이재원;홍준기
    • 한국소음진동공학회논문집
    • /
    • 제15권6호
    • /
    • pp.645-651
    • /
    • 2005
  • The construction noise Is one of the main causes of environmental impact. The complaints about it have been increasing every year. In order to reduce construction machinery noise, the product noise labeling for construction machinery has been recommended since 1 February 1996 and In the near future the government will convert the recommended product noise labeling to the mandatory product noise labeling for high noise construction machinery. Therefore, we investigated the noise and vibration level of 302 construction machines in construction work sites. This paper presents the basic data that will be used for setting the standard of construction machinery noise and predicting the noise level near construction work sites in environmental Impact assessment.

배경잡음을 고려한 4배 가변 압축률을 갖는 ADPCM의 C6000 DSP 실시간 구현 (Implementation of Quad Variable Rates ADPCM Speech CODEC on C6000 DSP considering the Environmental Noise)

  • 김대성;한경호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.727-729
    • /
    • 2002
  • In this paper, we proposed quad variable rates ADPCM coding method and its implementation on C6000 DSP, which is modified from the standard ADPCM of ITU G.726 for speech quality improvement considering the environmental noise Four coding rates, 16Kbps, 24Kbps, 32Kbps and 40Kbps are used for speech window samples and the rate decision threshold is decided by the environmental noise level. The object of the proposed method is to reduce the coding rate while retaining the speech quality and the speech quality is considerably close to 40Kbps single rate coder with the coding rate close to 16Kbps single rate coder under the environmental noise. The environmental noise level affects the coding rate and the noise level is calculated per every speech window samples. At high noise level, more samples are coded at higher rates to enhance the quality, but at low noise level, only the big speech signals are coded at higher rates and more speech samples are coded at lower coding rates to reduce the coding rates. The influence of the noise on tile speech signal is considerably high for small signals and the small signal has the higher ZCR (zero crossing rate). The method is simulated in PC and to be implemented on C6000 floating point DSP board in real time operations.

  • PDF

Leq, Lr, TNI 평가법에 의한 부산시 주요 상가변의 소음도 분석 (An Analysis on Traffic Noise at Pusan Shopping Districts by Leq, Lr, TNI Ratings)

  • 한돈희
    • 한국환경보건학회지
    • /
    • 제16권1호
    • /
    • pp.9-19
    • /
    • 1990
  • To evaluate the degree of traffic noise at the main shopping districts, 30 sites, in Pusan and produce the basic data of traffic noise counterplan, this research was conducted. Noise rating methods utilized were Leq(equivalent continuous sound level), Lr (rating sound level) and TNI (traffic noise index). As the results, all sites passed beyond Korean Environmental Noise Standard 70 dB(A) in Leq and 46.7% sites fell under 'widespread complaints'step, 40.0% 'threat of community' action'step, 13.3% 'vigorous community action'step by Lr ratings, and 30.0% sites were over acceptable TNI criteria of 74. Therefore, traffic noise at Pusan shopping districts was very severe.

  • PDF

A Study on Estimation of Noise Damage caused by Rupture of Butane-can(volume : 34g)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Choi, Seong-Joo;Lee, Jong-Rark;Lim, Dong-Yeon
    • 한국가스학회지
    • /
    • 제11권1호
    • /
    • pp.13-17
    • /
    • 2007
  • It is very insecure to treat a butane can for cooking out of door. The human injury from the accidents of butane cans has been getting increased 1.5 times yearly since 2003. In this context, the Institute of Gas Technology Training in Korea Gas Safety Corporation carries out explosion experiment to make trainees to take all possible measures to ensure safe management of gas in the field by fully recognizing the hazards of gas explosion accidents. This study intends to examine the influence of such explosion experiments on the trainees witnessing nearby. The GEN exposed to the active students participating in the experiment away from 25 meters from the explosion site was 57.94 dB and the GEN to the passive students not participating away from 50 meters was 51.92 dB. According to Weber-Fechner's law for the lower value than 65 dB which is the environmental standard, it is safe from the place 15 meter far from the explosion place. The environmental standard of offices is 50 dB, and it is lower than the environmental standard if the office is 65 meter far from the explosion place.

  • PDF

철도소음의 높이별 방사특성을 고려한 수음 평가 위치 제안 (Suggestion of assessment height for noise measurement according to the vertical radiation characteristics of railway noise)

  • 조준호;장강석
    • 환경영향평가
    • /
    • 제23권1호
    • /
    • pp.29-37
    • /
    • 2014
  • Exact and precise noise measurement is the basis for the reduction measure R&D, impact assessment and prediction modeling for railway noise. In this study, research trend as well as national and international noise measurement standard are investigated. For the estimation of vertical radiation characteristics of railway noise, specially devised zig was used. From the noise measurement and analysis, exact noise height radiated from the railway was characterized. The obtained results will be used for the suggestion of the height of microphone position of railway noise measurements.

도로변 건물의 창문과 방음효과에 대한 평가 (A Study on the Sound Proof Efficiency of Windows for Road Traffic Noise)

  • 박성배;신재영;정종흡;정일현
    • 한국환경보건학회지
    • /
    • 제21권4호
    • /
    • pp.56-62
    • /
    • 1995
  • Recently, the traffic noise around residences and schools has become a serious social problem with the increase of the amount of transportation. This study was performed to investigate the sound proof efficiency of windows for traffic noise. The results were as follows 1) The traffic noise in 19 sites among 22 sampling sites was higher value than 65 dB(A) being roadside environment standard level in the daytime when all windows were opened, while the noise in 22 sampling sites was transmitted below standard level when all windows were closed. 2) The transmission loss of sound level at single window and double windows were 10~25 dB(A) and 11~29 dB(A) respectively. 3) The transmission loss of sound level at sampled school with sound proof pannel was 7~8 dB (A), which was lower 2~7 dB(A) than the theoretical value of the influence assessment . 4) The construction cost of double windows was lower 28% even if include the cost of setting up air conditioner for the summer season and the power consuming cost for its operation than that of sound proof pannel for traffic noise. 5) The effect of transmission loss of windows was more influenced by airtight than materials of windows.

  • PDF

시간별 교통량 변화에 따른 환경오염지도(대기 및 소음) 구축방안에 관한 연구 (Hourly Environmental Pollution (Air Pollution and Noise) Mapping Method by the Traffic Volume Change)

  • 조동명;권우택;나영
    • 환경영향평가
    • /
    • 제16권6호
    • /
    • pp.485-494
    • /
    • 2007
  • Air pollution and traffic noise from roads distributed near residential area has been a major social problem. In this study, an environmental pollution map for a residential area of Shihung-city was made by an expectation model based on hourly traffic volume change. Using the result from the model, a plan to reduce population in the residential area was established. The result of the modelling is summarized as follows: 1. At peak traffic hours (18 o'clock), 301-500 degree in hazardous and $d_{25}$ degree (25% of the residents are suffering extremely from the noise) in noise pollution were predicted in Jeongwang Main Road in Shihung city. 2. The calculated critical pollutant standard index, PSI showed the air pollution level, especially PM-10 high enough to require re-entrainment. 3. It was expected air pollution would extensively extend over the area distribution of each degree. However, noise pollution problem was limited to the area near roads.