• Title/Summary/Keyword: No-washing

Search Result 449, Processing Time 0.032 seconds

Alkaline Dyeing and Color Fastness of Polyester Fiber (폴리에스테르 섬유의 알칼리 염색과 견뢰도)

  • 정동석;오준석;이문철
    • Textile Coloration and Finishing
    • /
    • v.12 no.4
    • /
    • pp.248-255
    • /
    • 2000
  • Polyester fibers and fabrics have been dyed with disperse dyes in alkaline dyebath such as alkaline buffer and alkaline auxiliary(JPH-95) comparing a traditional acidic dyeing. After dyeing the samples were extracted with 100% DMF, and washing and rubbing fastnesses were measured. In dyeing at $100^\circ{C}$ the dyeing rate increased with decreasing fiber denier, regardless of dye baths, whereas the dyeing rates of the same denier fiber increased in the order of alkaline dyeing>acidic dyeing>JPH-95 dyeing. In dyeing at $130^\circ{C}$ the dyeing rate of PET fiber in JPH-95 dye bath decreased compared with the other two types of dye baths. In the time and temperature curve the dye uptake of JPH-95 dyeing was higher than the other two types of dye baths in the range of low temperature$(95~115^\circ{C})$. The equilibrium dye uptake increased in the order of 0.52d>2.04d>0.05d fiber. Washing fastness had no change in all three types of dye baths. But rubbing fastness was not good for alkaline dyeing except black dyes.

  • PDF

Development of Polymeric Layer for Enhancing The Adhesion of Nano-devices Fabricated by The Nanotransfer Molding Method

  • Lee, Gi-Seok;Seong, Myeong-Mo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.634-634
    • /
    • 2013
  • Transfer molding methods have a problem that weak adhesion between nanostructures and substrates. It is important to make various nano scale applications, also the stability of nanostructure on substrate is related with device performance. We studied an effect of poly 4-vinylphenol (PVP) as the polymeric adhesion layer between organic nanowires and a Si substrate when the nanowires are transferred by liquid-bridge-mediated nanotransfer molding method (LB-nTM). Their structural stability was examined by optical microscopy, scanning electron microscopy as multiple transfer molding and washing process. Field-effect transistors were fabricated with organic semiconductor nanowires on a polymeric adhesion layer and their electrical properties showed no significant difference as the one without the adhesion layer. As a result, adhesion layer can be used in the washing process and making multi-layer nano-scale patterns.

  • PDF

Analysis of the Compounds of Unpleasant Odor from the Cotton Fabrics through Different Washing Conditions (세탁조건에 따른 면직물 중의 악취성분 분석)

  • 박명자;최해운
    • The Research Journal of the Costume Culture
    • /
    • v.10 no.5
    • /
    • pp.555-564
    • /
    • 2002
  • The purpose of this research was to analysis compounds of unpleasant odor from the cotton fabrics in dehydration and drying process during washing. The cotton fabrics were treated with various commercial detergents and fabric softener or cationic surfactants such as Cetyltrimethylammonium bromide(CTAB) and Benzalkonium chloride(BC), then dehydrated and dried. The compounds of odor impregnated in fabric were detected by using CC-MS. The results are as follows: The fabrics treated with a powder-type detergent, CTAB and BC gave out compounds unpleasant odor. n-Butyraldehyde and isobutyaldehyde produced during microorganism growth were revealed as source of the compounds of the unpleasant odor. However, no aldehydes were detected from the fabrics treated with commercial fabric softener which seems to act as a deodorizer.

  • PDF

A Case of Successful Treatment in Paraquat Intoxication Casued by Subcutaneous Injection (피하주사에 의한 파라콰트 중독환자의 성공적 치료 1예)

  • GiI Hyo Wook;Yang Jong Oh;Lee Eun Young;Hong Sae Yong
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.3 no.2
    • /
    • pp.107-109
    • /
    • 2005
  • Paraqaut, a widely used herbicide, is extremely toxic, causing multiple organ failure in human. Most of paraquat intoxications happen through oral administration. But there is no clinical data for parenteral paraquat intoxication. A 35-year-old male injected paraquat solution on his forearm. He visited emergency room within 10 minutes and was treated with tourniquet, incision, washing and suction. After eight days, the patient was discharged without respiratory symptoms and complications. In treatment of parenteral paraquat intoxication, first aid was very important and the treatment should include tourniquet, incision, washing and suction in order to delay absorptions.

  • PDF

A Study on the Vibration Shock of Electric Appliances during Transport by Truck (트럭수송에 의한 전기.전자 제품의 진동충격에 관한 연구)

  • Lee, Soo-Keun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.9 no.1
    • /
    • pp.7-10
    • /
    • 2003
  • This study was carried out to investigate vibration shock of electric appliances during transport. Microwave oven, TV, washing machine and refrigerator were singled out as the study items. Transport courses were selected as follow ; an expressway between Kumi and Seoul for TV, an expressway between Kwangju and Seoul for microwave oven and washing machine, a national road between Inchon and Seoul for refrigerator. the values of vibration shock were measured to be ${\sim}3G$ on the national road and 1G on the expressway for up and down direction, ${\sim}0.5G$ on the national road and expressway for back and forth direction and ${\sim}0.8G$ on the national road and expressway for right and left direction. There was no damage during transport. These values were corresponding to grade II of KS A 1026 (General Rules of Performance Testing for Packaged Freights).

  • PDF

Change of Physicochemical Characteristics and Functional Components in the Cereals of Saengsik, Uncooked Food by Washing with Electrolyzed Water (전해수 처리한 생식 원료 곡류의 이화학적 특성 및 기능성 성분의 변화)

  • Jin, Tie-Yan;Oh, Deog-Hwan;Rhee, Chong-Ouk;Chung, Dong-Ok;Eun, Jong-Bang
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.506-512
    • /
    • 2006
  • We investigated changes in the physicochemical characteristics and functional components of the Saengsik cereal grains-milled rice, brown rice, glutinous rice, and barley- by washing with electrolyzed water. There were no changes in the composition of all cereal grains that was dried with hot-air and freeze-dried after being washed with electrolyzed water. The L and a values were not affected by drying in milled rice, brown rice, glutinous rice, or barley, but the b value increased in milled rice and glutinous rice-this increase was greater with hot-air drying than with freeze-drying. The dietary fiber content of the all cereals increased with hot-air drying. The niacin content decreased in all cereals; the extent of this change was greater with hot-air drying than with freeze-drying. The ${\beta}-glucan$ content of barley was higher in samples that underwent freeze-drying than in those treated by hot-air drying, but was not affected by washing with electrolyzed water. Thus, other than a change in color for milled and glutinous rice, no changes in the physicochemical characteristics and functional components these products were observed with freeze-drying. Data indicate that the electrolyzed water washing could be effectively used as pasteurization step in the uncooked cereal grains.

A Study on the Prevention of Nosocomial Respiratory Infection in Critical Care Nurses (중환자실 간호사의 호흡기병원감염 예방에 관한 연구)

  • Choi Ji-Youn;Park Kyung-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.6 no.3
    • /
    • pp.397-413
    • /
    • 1999
  • The purpose of study is to prevent Nosocomial Respiratory Infection after understand the Correlation about Recognition and Performance of Critical Nurses. Data were collected from Critical Nurses 300 persons who has worked in 14 Subsidary Hospitals of University in Seoul and the collection periode is from Nov. 1st, 1997 to Jul. 14th. 1998. There are 40 questions and constructed by 6 Domains which Hand Washing, Suction Management, Airway Management, Respiratory Instrument. Ventilation and Respiratory Intervention. Also, the Data were analized with SPSS program. The obtained results are as follows : (1) The Mean of Recognition for Prevention of Nosocomial Respiratory Infection is 4.649 and by Domains, Respiratory Intervention(4.758), Suction Management (4.669), Airway Management(4.660), Hand Washing(4.651), Ventilation(4.605) and Respiratory Instrument(4.561) according to the Mean. (2) The Mean of Performance for Prevention of Nosocomial Respiratory Infection is 3.991 and by Domains, Respiratory Intervention(4.498), Airway Management (4.107), Hand Washing(4.084), Suction Management(3.898), Respiratory Instrument(3.860) and Ventilation(3.690) according to the Mean. (3) In the Correlation of Recognition and Performance for the Prevention of Nosocomial Respiratory Infection, Hand Washing(r=0.755, p=0.000), Airway Management(r=0.724, p=0.000), Respiratory Intervention(r=0.693, p=0.000) are mentioned significant correlation level. The Performance is good whenever the Recognition is high for Respiratory Instrument(r=0.143, p=0.054) but it's not significant level and Suction Management and Ventilation has no Correlation. (4) In Normal Properties, The Recognition is good(p<.05) when Nurses has plenty Clinical Career, Attendance of the Education and Exclusive Nurse for the Respiratory Infection is in Hospital. The Age is not significant correlation level statistically but represent a little correlation. The Performance is good(p<.05) when Elder Age, Attendance of the Education and the plenty Clinical Career is not significant correlation level statistically but represent a little correlation. Another properties has no menas. According to the results, Suggestion is as follows ; (1) Required Education to advance Recognition and Performance about Prevention of Nosocomial Respiratory Infection for a little clinical career of Nursing and younger Nurses. (2) It needs to analyze Performance about Prevention of Nosocomial Respiratory Infection by observation of research worker.

  • PDF

Nitrogen oxide (NOX) and Sulfur Oxide (SOX) Removal Capacities of Textile FabricsCoated with Nano-pore Materials (나노 공극소재로 코팅된 모헤어의 질소산화물(NOX) 및 황산화물(SOX) 제거 성능평가)

  • Lee, Jae-Uk;Yang, Keun-Hyeok;Mun, Ju-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.157-158
    • /
    • 2020
  • The present study examined the effectiveness of textile fabrics coated with nano-pore materials on removing the nitrogen oxide (NOX) and sulfur oxide (SOX) in the atmospheric environment. The tested approach is favorable for absorbing NOX and SOX, even under the washing condition.

  • PDF

Performance Evaluation of Nitrogen Oxide Removal by Air Purification Blocks with Titanium Dioxide (이산화티타늄을 이용한 대기정화 블록의 질소산화물 제거 성능 평가)

  • Oh, Ri-On;Kim, Hwang-Hee;Park, Sung-Ki;Cha, Sang-Sun;Park, Chan-Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.5
    • /
    • pp.39-46
    • /
    • 2020
  • This study evaluated the nitrogen oxide (NOx) removal efficiency by air purification concrete blocks with titanium dioxide (TiO2). The concrete in the mixtures had a 30% water:cement ratio, to which TiO2 was added at 0%, 5%, and 10% of cement weight. The compressive strength reduction rate and removal efficiency of NOx were investigated. The result of the compressive strength test in the study indicated that addition rate of TiO2 did not lead to signifcant effect. In terms of the average removal efficiency of NOx, mix No. 1 using a TiO2 mixing ratio of 0% had a removal efficiency of 0.57% on average; thus, the removal effect w as not significant. For the other samples prepared by mixing, the average removal efficiencies for mix No. 2 (5% TiO2) were 58.86% and 62.05% for normal and washing surface treatments, respectively, and those of sample No. 3 (10% TiO2) were 59.94% and 67.61%. mixs No. 4 (5%) and No. 5 (10%), in which TiO2 diluted with distilled water was sprayed onto the block surface, had an average NOx removal efficiency of 61.72% and 68.48%, respectively. In terms of NOx removal efficiency, Mixs No. 3 and No. 5 with 10% TiO2 were better than Mixs No. 2 and No. 4 with 5% TiO2. In addition, analyzing the NOx removal efficiency results from the fixing method, it was capable to apply mixing (washing) and the diluted spray methods. Therefore, it was found that the diluted spray method applied in this study can be employed in any manufacture of air purification concrete blocks.

The Washing Effect of Precipitation on PM10 in the Atmosphere and Rainwater Quality Based on Rainfall Intensity (강우 강도에 따른 대기 중 미세먼지 저감효과와 강우수질 특성 연구)

  • Park, Hyemin;Byun, Myounghwa;Kim, Taeyong;Kim, Jae-Jin;Ryu, Jong-Sik;Yang, Minjune;Choi, Wonsik
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_3
    • /
    • pp.1669-1679
    • /
    • 2020
  • This study examines the washing effect of precipitation on particulate matter (PM) and the rainwater quality (pH, electrical conductivity (EC), water-soluble ions concentration). Of six rain events in total, rainwater samples were continuously collected every 50 mL from the beginning of the precipitation using rainwater collecting devices at Pukyong National University, Busan, South Korea, from March 2020 to July 2020. The collected rainwater samples were analyzed for pH, EC, and water-soluble ions (cations: Na+, Mg2+, K+, Ca2+, NH4+, and anions: Cl-, NO3-, SO42-). The concentrations of particulate matter were continuously measured during precipitation events with a custom-built PM sensor node. For initial rainwater samples, the average pH and EC were approximately 4.3 and 81.9 μS/cm, and the major ionic components consisted of NO3- (5.4 mg/L), Ca2+ (4.2 mg/L), Cl- (4.1 mg/L). In all rainfall events, rainwater pH gradually increased with rainfall duration, whereas EC gradually decreased due to the washing effect. When the rainfall intensities were relatively weak (<5 mm/h), PM10 reduction efficiencies were less than 40%. When the rainfall intensities were enhanced to more than 7.5 mm/h, the reduction efficiencies reached more than 60%. For heavy rainfall events, the acidity and EC, as well as ions concentrations of initial rainwater samples, were higher than those in later samples. This appears to be related to the washing effect of precipitation on PM10 in the atmosphere.