• Title/Summary/Keyword: No-load condition

Search Result 364, Processing Time 0.026 seconds

Stringer Shape Optimization of Aircraft Panel Assembly Structure (항공기 패널 조립체 구조물의 스트링거 형상 최적화)

  • Kim Hyoung-Rae;Park Chan-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.136-142
    • /
    • 2006
  • Optimization of the aircraft panel assembly constructed by skin and stringers is investigated. For the design of panel assembly of the aircraft structure, it is necessary to determine the best shape of the stringer which accomplishes lowest weight under the condition of no instability. A panel assembly can fail in a variety of instability modes under compression. Overall modes of flexure or torsion can occur and these can interact in a combined flexural/torsion mode. Flexure and torsion can occur symmetrically or anti-symmetrically. Local instabilities can also occur. The local instabilities considered in this paper are buckling of the free and attached flanges, the stiffener web and the inter-rivet buckling. A program is developed to find out critical load for each instability mode at the specific stringer shape. Based on the developed program, optimization is performed to find optimum stringer shape. The developed instability analysis program is not adequate for sensitivity analysis, therefore RSM (Response Surface Method) is utilized instead to model weight and instability constraints. Since the problem has many local minimum, Genetic algorithm is utilized to find global optimum.

Stator winding faults diagnosis system of induction motor using LabVIEW (LabVIEW를 이용한 유도전동기 고정자 권선 고장진단시스템)

  • Song, Myung-Hyun;Park, Kyu-Nam;Lee, Tae-Hun;Han, Dong-Gi;Park, Kyung-Han
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2658-2660
    • /
    • 2005
  • This paper presents a stator winding fault diagnosis technique of induction motor on the PC - based virtual instrumentation system designed using the graphical programming language LabVIEW. This method collects the 3-phase current signals using the current probe amplifier and PXI/DAQ system then the preprocessing removes the noise using LPF, after then this method transforms the stator current to Park's vector and obtains the each Park's Vector pattern and detects stator winding fault by comparing the obtained faulted pattern with the healthy pattern. This proposed LabVIEW based diagnosis system is applied to the 3 phase 1 hp induction motor and obtained the reasonable results under no load condition. The test results give us the possibility a simple and realistic on-line winding fault diagnosis system.

  • PDF

A Study on the Adaptive Congestion Control Schemes in ATM LANs (ATM LAN에서 적응적 폭주제어 방식에 관한 연구)

  • Lee, Woo-Seung;Moon, Kyu-Choon;Kim, Hoon;Park, Kwang-Chae
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.129-132
    • /
    • 1999
  • In this Paper, new congention control schemes using the adaptive rate control for ATM LANs are presented. If is preferable for hosts in LANs to be able to send bursts at the same speed as the interface link speed in a lightly loaded condition, and as the network load increases, to reduce their traffic rate adaptively in order to avaid network congestion. We propose to apply such a rate control concept for two different traffic classed in the ATM LANs. For the first traffic class requiring no bandwidth reservation, i.e, a best effort service class, a combination of the end-to-end adaptive peak rate control with the link-by-link backpressure control is proposed. For the second traffic class, requiring the bandwidth reservation for the burst transmission, i.e. guaranteed burst service class, a combination of he adaptive peak rate control with the fast bandwidth reservation is proposed.

  • PDF

A Study on the Measurement for Table Deflection using Laser Interferometer and Simulation (레이저를 이용한 테이블 처짐 측정과 시뮬레이션에 관한 연구)

  • 김민주
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.6
    • /
    • pp.55-63
    • /
    • 1999
  • The acceleration of the performance of machine tools influences the development of the semi-conductor and optical technology as the development of NC and measurement technology. Because the measurement has been done to unload condition without considering of mechanical stiffness in the case of machining center as we measure the quasi-static error of machine tools on general study people who works on the spot has many problems on the data value. Also there are no satisfiable results until now in spite of many studys about this because the deflections of the table and the shaft supporting a workpiece influence, influence the accuracy of the table and shaft supporting a workpiece influence the accuracy of the workpiece. And there is doubt about the inspection method of measured error. In this paper Therefor we will help working more accurately on the spot by measuring analyzing displaying the defoec-tion of the table and support shaft when we load on the table and the support shaft of machining center using laser interfer-ometer. Also we try to settle new conception of the measurement method and more accurate grasp of the deflection tenden-cy by verifing the tendency of the error measured through the comparison of the simulated error measured through the comparison of the simulated error using ANSYS a common finite element analysis program which is able to measure heat deformation material deformation and error resulted from this study.

  • PDF

A New Phase Shift Full Bridge Converter with Serially Connected Two Transformers (직렬 연결된 두 개의 트랜스포머를 갖는 새로운 위상 천이 풀 브릿지 컨버터)

  • 구관본;김태성;문건우;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.443-452
    • /
    • 2002
  • A new phase shift full bridge (PSFB) converter with serially connected two transformers for telecommunication equipments of several hundred watts is proposed. The main features of the proposed converter are a wide input voltage range, an easiness to meet the requirement for zero voltage switching (ZVS) condition at a light load, and a small output voltage ripple. Furthermore, the serially connected two transformers can replace both a main transformer and an output inductor since the two transformers act as not only a main transformer but an output inductor by turns. Therefore, there is no need to use an output inductor, then the proposed converter features high power density. A mode analysis, design equations through a large signal modeling, and experimental results are presented to verify the validity of the proposed converter.

A New Algorithm Based on ASH in Local Modes Detection of Pathrate (ASH를 이용한 Pathrate에서의 Local Mode 검출 알고리즘)

  • Huang, Yue;Kim, Yong-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.5 s.43
    • /
    • pp.1-8
    • /
    • 2006
  • Network measurement is a vital part of network traffic engineering. In a network, the metric 'capacity' characterizes the maximum throughput the path can provide when there is no traffic load, or the minimum transmission rate among all links in a path. Pathrate is one of the most widely used network capacity measurement tools nowadays. It's famous for its accurate estimation result and non restriction of the temporal network traffic condition. After several years of development, its performance becomes more stable and reliable. Extant local modes detection algorithm in pathrate is based on statistic methodology histogram. This paper suggests a new algorithm for local modes detection based on ASH (Averaged Shifted Histogram). We have implemented this algorithm and will prove it can accomplish the same task as the original one with a better result.

  • PDF

Contactless DC Circuit Breakers Using MOS-controlled Thyristors (전력용 사이리스터 MCT를 이용한 무접점 직류차단기)

  • Sim, D.Y.;Kim, C.D.;Nho, E.C.;Kim, I.D.;Kim, Y.H.;Jang, Y.S.
    • Journal of Power System Engineering
    • /
    • v.4 no.1
    • /
    • pp.45-50
    • /
    • 2000
  • Circuit breakers have traditionally employed mechanical methods to interrupt excessive currents. According to power semiconductor technology advances in power electronic device, some mechanical breakers are replaced with solid state equivalents. Advantages of the contactors using semiconductor devices include faster fault interrupting, fault current limiting, no arc to contain or extinguish and intelligent power control, and high reliability. This paper describes the design of a static $100{\pm}10%V$ and 0 to 50A DC self-protected contactor with 85A "magnetic tripping" and 100A interruption current at $2.2A/{\mu}s$ short circuit of load condition using a new power device the HARRIS MCT (600V-75A). The self-protection circuit of this system is designed by the classical ZnO varistor for energy absorption and turn-off snubber circuit ("C" or "RCD") of the MCT.

  • PDF

A STUDY ON THE FRACTURE TOUGHNESS OF DENTAL AMALGAMS (치과용(齒科用) 아말감의 파괴인성(破壞靭性)에 관한 연구(硏究))

  • Huh, Hyeon-Do;Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.20-32
    • /
    • 1990
  • The plane strain fracture toughness of a material characterize the resistance to fracture in the presence of a sharp crack under severe tensile condition. Fracture toughness can be determined by indentation method. The purpose of this study was to investigate the fracture toughness of dental amalgams by measuring the plane strain fracture toughness and the fracture toughness from indentation method. Two conventional and four high copper amalgam alloys were employed for this study. The amalgams were prepared according to the A.D.A. spec. No. 1 and inserted into the specially designed mould with the single edge notch specimen to use in 3-point bending method. The specimens (20mm long, 4mm wide, 2mm thick) were stored at $37^{\circ}C$ for 1 week, and tested in 3-point bending by means of Instron at a cross-head speed of 1mm/min. In indentation method, the specimens were made in same manner as single edge notch specimens. The test was conducted with Vickers hardness tester at 10kg load. The following results were obtained. 1. The plane strain fracture toughness and the fracture toughness from indentation method were higher in the low copper amalgams than the high copper amalgams. 2. In high copper amalgams, the fracture toughness of amalgams decreases according as the copper contents increase. 3. In similar copper contents, the single composition amalgams have a higher fracture toughness than the admixed amalgams.

  • PDF

Study on the LED BLU Driving Circuit with a Local-dimming Structure (다분할 디밍구조를 갖는 LED BLU 구동회로에 관한 연구)

  • Park, Yu-Cheol;Kim, Hee-Jun;Chae, Gyun;Baek, Ju-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.292-300
    • /
    • 2009
  • This paper presents an LED BLU driving circuit with a local-dimming structure. The efficiency of the proposed LED driver has been improved by parallel driving 8 serial-connected LED arrays. It employed the soft-switching boost converter topology to reduce the switching power loss of the hard switching boost converter. Soft- and hard-switching converters have the same structure except that the free-wheeling diode in the hard-switching converter is replaced with the n-channel MOSFET in the soft-switching one. The proposed boost converter was compared with the hard switching converter. The soft-switching converter reveals superior ripple and efficiency. A smaller inductance can be used for the soft-switching converter contrasting to the hard-switching one. We also studied on an over-voltage protection circuit of the output of the driver at the no load condition. The protection circuit was applied to the proposed driver, and its operation was confirmed by experiment. Using a local-dimming technique, power consumption of LCD BLUs can be reduced as low as possible according to the brightness of its image.

Improvement of Output Waveforms in UPS Using the Discrete Control Technique (이산제어기법을 이용한 UPS의 출력파형 개선)

  • 김대곤;박해암;오금곤;조금배;백형래;김영동
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.57-63
    • /
    • 1997
  • Uninterruptible power supply(UPS) system should provide a good quality and stable power supply no matter what the condition of the raw mains. And when the mains fails, it must provide uninterrupted power to the load for a specified time. In this paper. discrete control system is introduced to improve output waveforms of UPS. This technique can be obtained output voltage by discrete data of synchronous control and voltage control to various loac. And then, the compact and light UPS can be realized by remove of the analog circuit and simulation and ezperinentation were performed with this control algofihtm. The experiment result show the effectiveness of proposed UPS system uwing the discrete control techjique.

  • PDF