• 제목/요약/키워드: No-Load Test

검색결과 690건 처리시간 0.022초

가변부하 및 탄성부하를 이용한 저항성 기구 운동 시 발현되는 상지근육의 근 활동치 비교분석 (Comparative Analysis of Muscle Activities for Upper Extremity During Resistance Exercises Using Variable and Elastic Loads)

  • 임영태
    • 한국운동역학회지
    • /
    • 제16권2호
    • /
    • pp.37-44
    • /
    • 2006
  • The purposes of this study were to analyze and compare EMG activities of the pectoralis major, biceps brachii, triceps brachii, and brachioradialis muscles during biceps curls using a VRT device and an elastic tubing. Fifteen male college students were recruited as subjects and they performed 10-RM and 20-RM biceps curls. For each load and device condition, the mean and peak normalized EMG levels during different phases of a biceps curl were computed. For each load and phase, paired t-test (p.05) was used to find the significant difference between two devices. ANOVA with repeated measures was also used to find the significant difference among phases in terms of EMG values for each muscle. For each load and device condition, the peak and mean EMG levels during different phases of a biceps curl were computed The significant differences between devices were found in biceps brachii for EA, MD, LD phases, and triceps brachii muscles for all phases, respectively. However, no differences were found among phases for any muscle. This indicated that elastic band could have a similar characteristics of VRT. High antagonistic muscle activity as a function of injury prevention which found particularly in VRT device may suggest that elastic tubing can be a safer training device than VRT. This also imply that elastic tubing could be very effective as a home exercise tool for rehabilitation patients and elderly people.

서울지하철 9호선 2단계 개통에 따른 급행열차 선택 및 혼잡도 변화분석 (Express Train Choice and Load Factor Analysis as Line Extension in Seoul Metro 9)

  • 김경민;오석문;노학래
    • 한국철도학회논문집
    • /
    • 제19권5호
    • /
    • pp.663-671
    • /
    • 2016
  • 본 연구에서는 교통카드자료를 기반으로 한 김경민 외[1]의 승객경로추적 방법을 이용하여 서울지하철 9호선 2단계 개통에 따른 급행열차 선택에 대한 변화를 분석하였다. 분석결과 2단계 개통 전과 비교하였을 때, 1단계 구간 기존 승객들의 급행열차 선택 비율은 변하지 않음을 확인하였다. 개통 전 후로 나누어 각각에 대한 다항로짓모형을 개발하였고 개통 전 후 모형의 전이성을 확인하였다. 하지만, 급행열차에 대한 선택이 높은 장거리 승객의 증가로 인해 2단계 개통 후 급행열차의 혼잡도가 약 6.7% 상승하였고 일반열차와의 혼잡도 차이는 증가하였다.

용량별 인장력 측정용 턴버클의 해석 및 실험 (Analysis and Test for Turn-buckle of Capacity for Measuring Tensile Force)

  • 신경재;이수헌;이희두
    • 한국강구조학회 논문집
    • /
    • 제23권6호
    • /
    • pp.715-724
    • /
    • 2011
  • 인장구조 시스템에서 구조물의 하중을 지지하는 인장재 사이에 삽입되어 인장력을 조절하는 장치가 턴버클이다. 인장재가 인장구조에서 중요한 부재임에도 불구하고, 현재 인장재에 발생하는 인장력을 경제적이고 간단하게 측정하기 위한 방법이 제안되지 못하였다. 그리하여 인장구조시스템에 작용하는 인장력을 측정하기 위하여 인장력 측정장치를 개발하였다. 본 논문에서는 이론해석과 유한요소해석을 바탕으로 100kN, 200kN, 300kN급 측정한계하중을 가지는 턴버클을 실험하였다. 그 결과 이론적 해석, 유한요소해석, 실험결과는 대체로 일치하는 것으로 나타났다. 또한 유한요소해석에 의한 측정용 턴버클의 극한강도를 조사해보면, 측정한계하중의 5배 이상의 과하중에서도 충분한 안전성을 확보하고 있음을 확인할 수 있었다.

Suppression of performance degradation due to cold-head orientation in GM-type pulse tube refrigerator

  • Ko, Junseok;Kim, Hyobong;Park, Seong-Je;Hong, Yong-Ju;Koh, Deuk-Yong;Yeom, Hankil
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권4호
    • /
    • pp.50-53
    • /
    • 2012
  • This paper describes experimental study on GM-type pulse tube refrigerator (PTR). In a PTR, the pulse tube is only filled with working gas and there exists secondary flow due to a large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus, the cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube refrigerator is fabricated and tested. The cooing performance of the fabricated PTR is measured as varying cold-head orientation angle and the results are used as reference data. Then, we divided interior space of pulse tube into three segments, and fixed the various size of screen mesh at interface of each segment to suppress the performance degradation due to secondary flow. For various configuration of pulse tube, no-load test and heat load test are carried out with the fixed experimental condition of charging pressure, operating frequency and orifice valve turns. From experimental results, the fine screen mesh shows the effective suppression of performance degradation for the large orientation angle, but the use of screen mesh cause the loss of cooling capacity rather than the case of no insertion into pulse tube. It should be compromised whether the use of screen mesh in consideration of the installation limitation of a GM-type pulse tube refrigerator.

레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석 (Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply)

  • 유지호;조종현;정민길;박성진;강광희
    • 한국군사과학기술학회지
    • /
    • 제22권1호
    • /
    • pp.60-71
    • /
    • 2019
  • Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.

인공치와 의치상의 재질에 따른 의치상 하부 지지조직에의 응력전달에 관한 연구 (A STUDY OF THE STRESS TRANSMISSION OF VARIOUS ARTIFICIAL TEETH AND DENTURE BASE MATERIALS TO THE UNDER-LYING SUPPORTING TISSUES)

  • 정형곤;정문규;이호용
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.79-100
    • /
    • 1989
  • The Purpose of this study was to investigate material differences in stress transmission among various artificial teeth and denture base materials. For this study, a two-dimensional finite element model and a two-dimensional photoelastic model of a mandible with complete denture were made. A resin tooth and a porcelain tooth were used as artificial teeth, and a resin base, a metal lined base, and a soft-liner lined base were used as denture bases. An occlusal load was applied and principal stresses generated in the supporting tissues were compared. To test the impact stress transmission, strain gauge attached to the denture base specimens made of the different materials were made in thick and thin groups. Voltage outputs from hitting the specimen with a steel ball were compared. The results were as follows : 1. In FEM, increasing the mucosal thickness reduced the maximum principal stresses in the supporting tissues, but altering the tooth materials and the base materials induced no difference in the stresses. 2. In photoelastic model study, no difference in fringe order among the specimens were observed, but the thick mucosa group and the soft-liner lined group revealed a more uniform distribution of the load. 3. In strain measuring, the impact force transmission was highest in the soft-liner lined group, and was the lowest in the metal lined group(p<0.01). 4. In the thin group using the resin base, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the thick group. In the soft-liner lined group, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the metal lined group. 5. The thick group showed lower impact stress transmission than the thin group(p<0.01).

  • PDF

압입과 압축에 의한 광중합형 수복용 복합레진의 기계적 성질 평가 (AN EVALUATION OF MECHANICAL PROPERTIES OF LIGHT-CURED RESTORATIVE COMPOSITES BY INDENTATION AND COMPRESSION TEST)

  • 이용우;유미경;조영곤;배태성;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제24권3호
    • /
    • pp.511-518
    • /
    • 1999
  • This study was performed to evaluate the mechanical properties of light-cured restorative composites by compression and indentation tests. Five commercially available light-activated composites (Heliomolar : HM, Aelitefil : AF, Amelogen : AG, Clearfil AP-X : CF, Z100 ZH) were used Disc specimens of 12mm in diameter and 1 mm in thickness and Cylindrical specimens of 3mm in diameter and 6mm in length were prepared for the indentation and compressive test, respectively. All specimens were immersed in distilled water at $37^{\circ}C$ for 30 days. An indentation test of 68-degree trigonal diamond pyramid was made under 10 g load for 15 seconds and an Knoop indentation test was made under 50 g load for 15 seconds. Hardness numbers, characteristic indentation depths and permanent deformation were measured during indentation of the 68-degree trigonal diamond pyramid compressive test was carried out at a crosshead speed of 0.5mm/min. The results obtained were summarized as follows, 1. The highest hardness value was obtained in the CF group and the lowest value was obtained in the HM group. Hardness values showed no significant, difference between AG group and HM group but other groups showed the significant differences in each group(p<0.05). 2. Hardness number by Knoop pyramid were higher than those of 68-degree trigonal diamond pyramid. 3. Plastic deformation during the indentation of 68-degree trigonal diamond pyramid was the lowest in the CF group and the largest in the HM group. Results of Tukey test showed the significant difference between CF group and others; also between ZH and AF groups and AG and HM groups(p<0.05) 4. The highest compressive strength was obtained in the CF group and the lowest compressive strength was obtained in the ZH group. Compressive strength values showed no significant difference between CF group and ZH group but other groups showed the significant differences in each group(p<0.05).

  • PDF

무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구 (A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable)

  • 김영한;최종혁;윤기섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF

수종의 섬유보강재가 복합레진의 파절강도에 미치는 영향 (FRACTURE STRENGTH OF COMPOSITE RESIN WITH VARIOUS FIBER REINFORCING MATERIALS)

  • 박지만;조용범;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.371-380
    • /
    • 2000
  • The effect of fiber reinforcing materials on the fracture strength of composite resin was evaluated. Each ten composite resin bars reinforced by glassfiber[Fiber-Splint ML$^{(R)}$(Polydentia SA, Switzerland)], polyethylene fiber [Ribbond$^{(R)}$(Ribbond Inc., U.S.A.)] and polyaramid fiber[Kevlar$^{(R)}$(DuPont, U.S.A.)] were loaded under the 3-point compression technique. Another ten pure composite resin bars without reinforcement were used as a control group. Then mean fracture strength and standard deviation were calculated and a ANOVA and Scheffe test were used in statistics. The results were as follows: 1. Kevlar group showed the highest fracture strength as 175.5MPa (p<0.05). Fiber-Splint ML group showed the lowest fracture strength as 112.7MPa. 2. The mean value of fracture strength in Ribbond group was 136.4MPa, and that of unterated control group was 143.6MPa. No difference was found between the two groups. 3. Ribbond and Kevlar reinforcement groups showed a catastrophic failure, where complete separation of pieces occurs to a unseparated fracture pattern. The use of Kevlar reinforcement fibers with composite resin showed significant increase in the average load failure and the presence of the fibers did prevent the catastrophic crack propagation present in the unreinforced samples. The use of Ribbond reinforcement fibers with composite resin showed no significant increase in the average load failure. However, the presence of the fibers did prevent the catastrophic crack propagation. Because high strength of glassfiber are rapidly degraded on exposure to moisture and humidity. The use of Fiber-Splint ML reinforcement fibers with composite resin showed significant decrease in the average load failure and displayed catastrophic fractures.

  • PDF

만성 발바닥 근막염 환자에게 물리치료와 코르티코스테로이드 주사가 미치는 효과 비교 (Comparison of the Effects of Physiotherapy vs. Corticosteroid Injection in Patients with Chronic Plantar Fasciitis)

  • 추연기;김현수
    • 대한통합의학회지
    • /
    • 제9권4호
    • /
    • pp.237-249
    • /
    • 2021
  • Purpose : This study was to compare the effect changes after physical therapy (extracorporeal shock wave therapy + high-load strengthening exercise) or corticosteroid injection in patients diagnosed with chronic plantar fasciitis. Methods : A total of 40 patients were randomly assigned to each group of 20. According to the intervention method, "Group 1. Physiotherapy" was performed for 12 weeks, and "Group 2. Corticosteroid injection" was performed only once. As a pre-intervention test, plantar fascia thickness, pain intensity I, II (What is the most painful moment of the day?, How painful is the first step in the morning?), and functional performance were measured. To compare the effects of each group, the tests 3, 6, and 12 weeks after were also performed using the same measurement method. Also, after 12 weeks, patient satisfaction was also compared. Results : There was no significant difference between the groups in the change in the thickness of the plantar fascia during all periods. However, pain intensity I, II was significantly lower in Group 1 than in Group 2 at only 12 weeks and functional performance was also significantly increased in Group 1 compared to Group 2 at only 12 weeks. Also, there was no significant difference between groups in patient satisfaction. Conclusion : The physiotherapy protocol, which consisted of extracorporeal shock wave therapy and high-load strengthening exercise, showed excellent results, especially after 12 weeks, compared to corticosteroid injection. It is recommended as a more effective treatment method as it is possible to safely return to daily life by reducing pain and improving functional performance.