• 제목/요약/키워드: No load temperature

검색결과 241건 처리시간 0.031초

불량연료 사용시 농용등유 엔진의 Oil Dilution 현상에 관한 연구 (Study on the Oil Dilution of the Farm Kerosee Engine while Using Impure Fuels)

  • 김만수;김성래;오세인
    • Journal of Biosystems Engineering
    • /
    • 제2권1호
    • /
    • pp.1-6
    • /
    • 1977
  • The dilution of crankcase oil with unburned portions of the fuel during operating is one source of the oil contaminations which will reduce engine life.It has been learned that major causes of oil dilution may be the result of using impure fuels which were mixed with water, dust, and some others, but very little was known about this. This study was conducted to develop a more intimate understanding about oil dilution of the farm kerosene engine while using impure fuel mixed with expecially diesel. Fuels being used in this study were 9 kinds of mixed fuels, kerosene and diesel. Farm kerosenen engine of 10 P.S. was tested at no-load of 1000 and 2000 rpm., such as 1/4, 2/4, 3/4, 4/4, and 11/10 loads for understanding about oil dilution of keresene engine.The result of this study are summarized as follows : 1. The amounts of oil dilution of the engine being tested was increased with increase in the applied loads and the contents of diesel in the mixed fuels when using fuels other than kerosenen and diesel, whereas at $D_100$ fuel the comount of oil dilution decreased in some cases. The lowest value was measured to be 20 cc/hr, at $K_90$ fuel of no-load condition, and the highest value to be 293cc/hr. at $K_{10}$ fuel of 4/4 load condition. 2. When the engine was operated at no-load condition, the amount of oil dilution at 100rpm. was much more than at 2000 rpm. 3. Because the fuel consumption and the oil dilution showed a similar tendency along the applied loads, the excessive fuel consumption of engines was supposed to be one of the important factors affecting oil dilution. 4. The temperature of crankcse oil was varied invesely with oil dilution, but they were not thought to be factors to determine each other variable. 5. The tested engine could be operated with high percentage of diesel mixed fuel from no-load condition to fully loaded condition, but it would be impossible to operate the engine for long hous continuously due to excessive speed fluctuation.

  • PDF

Differential Effects of Cotton and Polyester Ensembles on Changes in Clothing Surface Temperature, Skin Temperature and Skin Blood Flow During Heat Load

  • Tanaka, Kaori;Hirata, Kozo
    • 한국의류산업학회지
    • /
    • 제2권5호
    • /
    • pp.405-410
    • /
    • 2000
  • The effects of individual sweating rates on thermophysiological responses during the decrease phase of clothing surface temperature (Tcs) with cotton (C) and polyester (P) clothed subjects were examined. Seven women subjects were exposed in a climatic chamber at ambient temperature of $27.2^{\circ}C$, relative humidity of 50%, and their lower-legs were immersed in a water bath at a temperature of $35-41^{\circ}C$ for 70 min. During water immersion, Tcs in C-clothed subject rose immediately after the onset of sweating and then Tcs fell gradually. In C-clothed subjects, Tcs decreased directly (p<0.05) in proportion to total sweating rate (TSR), however no significant correlation was observed in P-clothed subjects. The relationship between TSR and changes in mean skin temperature, and skin blood flow showed negative correlation when wearing C-clothing (p<0.05), however, no significant correlation when wearing P-clothing. Individual TSR was correlated with threshold rectal temperature for sweating onset (p<0.05) with C- and P-clothed subjects. The results showed that individual TSR had significant effects on not only Tcs but also on thermoregulatory responses during the Tcs decrease phase.

  • PDF

DME/천연가스 HCCI 기관의 연소특성(기통 간 불균형과 EGR의 영향) (Combustion Characteristics of HCCI Engine Fueled DME and Natural Gas(Unbalance of Cylinder-to-Cylinder and Effect of EGR))

  • 정석호
    • 동력기계공학회지
    • /
    • 제14권3호
    • /
    • pp.13-18
    • /
    • 2010
  • HCCI engines fueled DME and natural gas have been studied on single-cylinder engine due to availability of reducing on $NO_X$ and PM simultaneously without deteriorating into high thermal efficiency, and thus it is clarified that higher maximum engine load is achieved as DME equivalence is smaller. In this study, combustion tests were accomplished on multi-cylinder engine for practical use of it. When minimum DME equivalence achieved maximum engine load on single-cylinder engine was applied to 4-cylinders engine, there was in unstable running condition that engine revolution fluctuated greatly and cyclically. It is the reason what misfire occurred intermittently with one the same as minimum DME equivalence on single-cylinder due to increase in energy for ignition at No. 1 cylinder with lower cylinder liner temperature. Maximum engine load was achieved by adopting EGR, though it decreased because of knocking at smaller engine load than single-cylinder due to increase in minimum DME equivalence.

Effects of Insulation Layer upon the Thermal Behavior of Linear Motors

  • Eun, In-Ung
    • Journal of Mechanical Science and Technology
    • /
    • 제17권6호
    • /
    • pp.896-905
    • /
    • 2003
  • A linear motor has many advantages next to conventional feed mechanisms: high transitional speed and acceleration, high control performance, and good positioning accuracy at high speed. Through the omission of a power transfer element, the linear motor shows no wear and no backlash, has a long lifetime, and is easy to assemble. A disadvantage of the linear motor is low efficiency and resultant high-temperature rise in itself and neighboring structures during operation. This paper presents the thermal behavior of the linear motor as a feed mechanism in machine tools. To improve the thermal behavior, an insulation layer is used. By placing the insulation layer between the primary part and the machine table, both the temperature difference and the temperature fluctuation in the machine table due to a varying motor load are reduced.

3상 10kVA 고온초전도 변압기의 특성 (Characteristics of a 10kVA three phase superconducting power transformer)

  • 이승욱;이희준;차귀수;이지광;류경우;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.24-26
    • /
    • 2001
  • The high temperature super-conductor transformer gains interests from the industries. This paper described construction and test results of a 10kVA HTS transformer. Three phase transformer with double pancake windings were constructed. BSCCO-2223 wire, silicon sheet steel core and FRP cryostats were used in that transformer After the test of basic properties of the 3 phase HTS transformer using no load test, short ciucuit test and full load test, continuous operation of 100 hours with pure resistive load has been carried out. Test proved over-load capability and reliability of the HTS transformer.

  • PDF

Strainless steel strip 광휘어닐링로 내의 열전달 해석 (A Numerical Analysis of Heat Transfer in Bright Annealing Furnace of Stainless Steel Strip)

  • 유흥선;정연태;장병록
    • 열처리공학회지
    • /
    • 제22권4호
    • /
    • pp.228-233
    • /
    • 2009
  • In order to predict the temperature distribution of stainless steel strip in Bright Annealing (BA) furnace, we performed the analysis of heat transfer and fluid flow using STAR-CCM+. The analysis model included unsteady fluid flow, heat transfer with radiation and moving grid. Two kinds of radiative properties, emissivity and reflectivity, were applied to the stainless steel strip, one is constant and the other is variable with time. As we call, the BA furnaces of stainless steel strip have two different types, muffle and no-muffle. The using of muffle type has been faced with some problems such as rising in material price and shortening of life cycle, etc. So the development of no-muffle type BA furnace is very important in order to save energy cost, lower environmental load and increase the productivity. The designed (or expected) temperature of stainless steel strip coming out of BA furnace was about $1065^{\circ}C$ while the environment temperature maintains around $1100^{\circ}C$. The result of our calculation was very close (or similar) to design temperature, and the application of radiative properties variable with time produced more accurate result than applying constant ones.

고온초전도변압기 특성시험 (Test of a High Temperature Superconducting Power Transformer)

  • 이희준;차귀수;김우석;한송엽;류경우;최경달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.33-35
    • /
    • 1999
  • This paper describes the test results of the single phase 3kVA high temperature superconducting power trans-former. The tapes are made with Bi-2223 and have silver alloy as the matrix. Four double pancake windings are used in total. Among them two double pancake windings are connected in series for high voltage winding and two double pancake windings are connected in parallel for low voltage winding. The rated voltages of each winding are 220/110 V. Fundamental characteristics are obtained through short circuit and no load tests. The over load capability and characteristics are investigated.

  • PDF

Theoretical Development and Design Aids for Expansion Joint Spacings

  • Lee, Hong-Jae;Lee, Cha-Don
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.101-111
    • /
    • 2000
  • It has been a well known fact that buildings having inappropriate expansion joints in their spacings may be subject to exterior damages due to extensive cracks on the outer walls under service loads and structural damages due to excessive moment induced by temperature changes at ultimate load conditions. Unfortunately, consistent code provisions are unavailable regarding spacings of expansion joints from different foreign structural codes. And a more serious problem is that no quantitative measurements on spacings is given in our codes for building structures. In order to establish a rational guideline on the spacing of expansion joints, theoretical approaches are taken in this study. The developed theoretical formula is, then, converted to a design chart for structural designers' convenience in its use. The chart considers both service and ultimate load stages.

  • PDF

셀룰로오스계 파일직물의 탄화가공 (A Study on the Burn-out Printing of Cellulose-blend Velvet)

  • 김호정
    • 한국의류학회지
    • /
    • 제23권5호
    • /
    • pp.757-763
    • /
    • 1999
  • The burn-out technique is used to result in the velvet cloth being patterned in open and solid areas by carbonize the cellulose fiber. It is examined how to burn out the cellulose part of the velvet without damage of the other part. The print paste indalca solution is mixed with sodium hydrogensulfate and lycerine and then screen-printed on the back side of the velvet. The effects of process conditions such as concentration of sodium hydrogensulfate dry heat fixation temperature and time pull no. and glycerine contents on the properties of ground farics were investigated. The yellowness index and the breaking load of silk ground fabrics afected by the process conditions especially concentration of sodium hydrogensulfate dry heat fixation temperature.

  • PDF

GM형 맥동관 냉동기의 저온부 경사도에 따른 냉각 성능 특성 연구 (Orientation dependence of GM-type pulse tube refrigerator)

  • 고준석;김효봉;박성제;홍용주;염한길;이청수;강인수;고득용
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.48-52
    • /
    • 2012
  • This paper describes experimental study on the orientation dependence of GM-type pulse tube refrigerator with helium and neon as working gas. A pulse tube refrigerator generates refrigeration work with gas expansion by gas displacer in the pulse tube. The pulse tube is only filled with working gas and there exists secondary flow due to large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube with orifice valve as a phase control device is fabricated and tested. The fabricated pulse tube refrigerator is tested with two different working gases of helium and neon. First, optimal valve opening and operating frequency are determined with experimental results of no-load test. And then, the variation of no-load temperature as orientation angle of cold-head is measured for two different working gases. Effect of orientation dependence of cold-head as working gas is discussed with experimental results.